Reports until 16:52, Friday 01 August 2025
H1 General (SEI)
anthony.sanchez@LIGO.ORG - posted 16:52, Friday 01 August 2025 - last comment - 21:05, Friday 01 August 2025(86140)
Friday Eve Shift Strarting Report.

TITLE: 08/01 Eve Shift: 2330-0500 UTC (1630-2200 PST), all times posted in UTC
STATE of H1: Observing at 149Mpc
OUTGOING OPERATOR: Oli
CURRENT ENVIRONMENT:
    SEI_ENV state: CALM
    Wind: 21mph Gusts, 14mph 3min avg
    Primary useism: 0.07 μm/s
    Secondary useism: 0.05 μm/s
QUICK SUMMARY:

Observing reached at 23:43:12 UTC But only after spending 13 min trying to determine why there is are SEI SDF Diffs.
We, (TJ, Oli, Me) decided to just accept them and hope for the best.

 

Images attached to this report
Comments related to this report
anthony.sanchez@LIGO.ORG - 21:05, Friday 01 August 2025 (86142)

I reverted all of these SDF's for the SEI GS13 on HAM 2, 3, 4, & 5 once we lost lock because Mr. Crouch said that those are older version of the filters.

Images attached to this comment
H1 General
oli.patane@LIGO.ORG - posted 16:43, Friday 01 August 2025 (86139)
Ops Day Shift End

TITLE: 08/01 Day Shift: 1430-2330 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Earthquake
INCOMING OPERATOR: Tony
SHIFT SUMMARY: Currently in NLN, but waiting to go into Observing after we figure out some weird SDF diffs with ISIHAM2/3/4/5.
LOG:

14:30UTC Relocking and in ACQUIRE_PRMI
15:23 NOMINAL_LOW_NOISE
    15:25 Observing
    18:06 Out of Observing due to SQZ unlock
    18:12 Back into Observing
    18:12 Out of Observing due to SQZ unlock
    18:14 Back into Observing
    18:15 Out of Observing due to SQZ unlock
18:45 Lockloss
    - sat in DOWN for a bit due to high ground motion and wind
    - ALSX was unlocking 10 seconds into LOCKING_ALS
21:59 NOMINAL_LOW_NOISE
    - Needed to INIT HAM 2/3/4/5 ISI guardians to remove SPM (and SDF) differences - caused a lockloss
22:02 Lockloss
22:54 NOMINAL_LOW_NOISE
    - Adjusted OPO temp and that got FC to lock
    - Issues with ISIHAM2/3/4/5 sdf diffs for GS13INF V1/2/3

                                                                                                                                                                                                                                                                                                                                                                                                                        

Start Time System Name Location Lazer_Haz Task Time End
15:05 FAC Nelly OpticsLab n Tech clean 15:17
18:51 VAC Gerardo FCES n Moving power supply 19:51
20:02   Ibrahim CER n Grabbing laptop 20:04
20:03 FAC Eric EY n Checking on chiller alarm 20:27
20:23   Ibrahim CER n Getting another laptop 20:26
22:33 VAC Gerardo FCES, FCET n Putting a couple labels on 22:49
LHO VE (VE)
gerardo.moreno@LIGO.ORG - posted 16:18, Friday 01 August 2025 - last comment - 16:23, Friday 29 August 2025(86137)
Filter Cavity Tube Gets One More Gauge PT-CC7

(Jordan V., Tony S., Gerardo M.)

Late entry

To get the gauge working at the filter cavity tube cross C7 we pulled the EtherCAT cable from cross C7 to cross D1, this allowed us to daisy chain the gauges at both crosses.  To land the EtherCAT cable both ends were terminated, thanks Tony. To get power to the gauge we used one of the outlets in the filter cavity enclosure and a small din rail mountable power supply, the supply provides 24 VDC.  Patrick took care of the software, see his aLOG here.

Currently we have the following items valved out along the filter cavity, two ion pumps;IPFCC6, IPFCC8, and the gauge PTCC7.  We plan to incorporate them to the main vacuum volume on the next couple of weeks.  Pressure at the gauge is low, thus we need to pump its volume down using an aux cart and a small turbo pump.

Images attached to this report
Comments related to this report
gerardo.moreno@LIGO.ORG - 17:11, Thursday 07 August 2025 (86256)VE

Last tuesday I was able to valve in the last two ion pumps into the filter cavity tube envelope, two of the 10" isolation valves at section C were closed to achieve this, then as the internal pressure of the filter cavity tube settle the isolation valves were opened.

Something to note with the performance of the HV cable for IPFCC8 (ion pump a the filter cavity cross 8) is a bit noisy, I noticed that the controller got noisy when I touched the HV cable, but will check both at a later time, maybe cable, grounding and/or controller issue.

gerardo.moreno@LIGO.ORG - 16:23, Friday 29 August 2025 (86645)VE

(Anna I., Jordan V., Gerardo M.)

Last tuesday we valved in a gauge to the filter cavity tube vacuum volume.

We pumped the dead volume down until the pressure reached high 10^-07 torr, then introduced the gauge to the "short" volume of the filter cavity tube, we had closed two isolation valves, we waited about 10 minutes, then the isolation valves were opened.  No issues to report.

Images attached to this comment
H1 General (Lockloss, SEI)
oli.patane@LIGO.ORG - posted 15:07, Friday 01 August 2025 - last comment - 14:15, Monday 04 August 2025(86138)
Lockloss

Lockloss at 2025-08-01 22:02 UTC after 3 minutes in NLN. We couldn't go into Observing because of SPM differences causing SDF diffs in the guardians for ISIHAM2/3/4/5. Last time we had this, I asked Jim what to do and he said to just INIT the guardians, and it caused a glitch, but we did not lose lock, and he said INITing them should not cause glitches or locklosses (85809). Today, I did the same thing and went to INIT the guardians, but when doing it for the first one, ISIHAM2, it caused a glitch and we lost lock from it.

Comments related to this report
thomas.shaffer@LIGO.ORG - 14:15, Monday 04 August 2025 (86179)

I don't see anything fishy going on on the guardian side of things here. When the ISI_HAM2 node had rerun the HIGH_ISOLATED state, after running through INIT, it changed a bunch of the GS13INF gains. See the end of the guardian log for the ISI_HAM2 and SEI_HAM2 nodes in the attached txt file. We then saw these changes later as well in SDF (alog84140), so the large earthquake script button might be conflicting with this.

Non-image files attached to this comment
H1 General (Lockloss)
oli.patane@LIGO.ORG - posted 11:55, Friday 01 August 2025 (86136)
Lockloss

Lockloss at 2025-08-01 18:45UTC due to earthquake

We are holding in DOWN due to the earthquake

LHO VE
david.barker@LIGO.ORG - posted 10:25, Friday 01 August 2025 (86135)
Fri CP1 Fill

Fri Aug 01 10:11:21 2025 INFO: Fill completed in 11min 17secs

 

Images attached to this report
H1 PSL
oli.patane@LIGO.ORG - posted 08:31, Friday 01 August 2025 (86133)
PSL Status Report Weekly FAMIS

Closes FAMIS#26433, last checked 86020

Everything is looking good besides the PMC reflected power being a bit high - it looks like it's been increasing over the past month.


Laser Status:
    NPRO output power is 1.866W
    AMP1 output power is 69.95W
    AMP2 output power is 140.6W
    NPRO watchdog is GREEN
    AMP1 watchdog is GREEN
    AMP2 watchdog is GREEN
    PDWD watchdog is GREEN

PMC:
    It has been locked 2 days, 2 hr 18 minutes
    Reflected power = 23.73W
    Transmitted power = 105.5W
    PowerSum = 129.3W

FSS:
    It has been locked for 0 days 2 hr and 47 min
    TPD[V] = 0.7741V

ISS:
    The diffracted power is around 3.8%
    Last saturation event was 0 days 2 hours and 47 minutes ago


Possible Issues:
    PMC reflected power is high

Images attached to this report
H1 SEI
oli.patane@LIGO.ORG - posted 08:14, Friday 01 August 2025 (86131)
Seismometer Mass Check Monthly FAMIS

Closes FAMIS#26504, last checked 85571

T240 (channels averaged between 2025-08-01 15:08:44 - 15:08:54 UTC)
Averaging Mass Centering channels for 10 [sec] ...
2025-08-01 08:08:54.266493

There are 12 T240 proof masses out of range ( > 0.3 [V] )!
ETMX T240 2 DOF X/U = -1.424 [V]
ETMX T240 2 DOF Y/V = -1.323 [V]
ETMX T240 2 DOF Z/W = -0.982 [V]
ITMX T240 1 DOF X/U = -2.045 [V]
ITMX T240 1 DOF Z/W = 0.443 [V]
ITMX T240 3 DOF X/U = -2.17 [V]
ITMY T240 3 DOF X/U = -0.963 [V]
ITMY T240 3 DOF Z/W = -2.619 [V]
BS T240 1 DOF Y/V = -0.351 [V]
BS T240 3 DOF Z/W = -0.431 [V]
HAM8 1 DOF Y/V = -0.541 [V]
HAM8 1 DOF Z/W = -0.871 [V]


All other proof masses are within range ( < 0.3 [V] ):
ETMX T240 1 DOF X/U = -0.121 [V]
ETMX T240 1 DOF Y/V = -0.125 [V]
ETMX T240 1 DOF Z/W = -0.158 [V]
ETMX T240 3 DOF X/U = -0.094 [V]
ETMX T240 3 DOF Y/V = -0.182 [V]
ETMX T240 3 DOF Z/W = -0.111 [V]
ETMY T240 1 DOF X/U = -0.015 [V]
ETMY T240 1 DOF Y/V = 0.105 [V]
ETMY T240 1 DOF Z/W = 0.155 [V]
ETMY T240 2 DOF X/U = -0.123 [V]
ETMY T240 2 DOF Y/V = 0.156 [V]
ETMY T240 2 DOF Z/W = 0.02 [V]
ETMY T240 3 DOF X/U = 0.163 [V]
ETMY T240 3 DOF Y/V = 0.004 [V]
ETMY T240 3 DOF Z/W = 0.071 [V]
ITMX T240 1 DOF Y/V = 0.244 [V]
ITMX T240 2 DOF X/U = 0.164 [V]
ITMX T240 2 DOF Y/V = 0.252 [V]
ITMX T240 2 DOF Z/W = 0.218 [V]
ITMX T240 3 DOF Y/V = 0.104 [V]
ITMX T240 3 DOF Z/W = 0.117 [V]
ITMY T240 1 DOF X/U = 0.038 [V]
ITMY T240 1 DOF Y/V = 0.096 [V]
ITMY T240 1 DOF Z/W = -0.0 [V]
ITMY T240 2 DOF X/U = 0.022 [V]
ITMY T240 2 DOF Y/V = 0.244 [V]
ITMY T240 2 DOF Z/W = 0.089 [V]
ITMY T240 3 DOF Y/V = 0.044 [V]
BS T240 1 DOF X/U = -0.08 [V]
BS T240 1 DOF Z/W = 0.162 [V]
BS T240 2 DOF X/U = 0.068 [V]
BS T240 2 DOF Y/V = 0.161 [V]
BS T240 2 DOF Z/W = 0.027 [V]
BS T240 3 DOF X/U = -0.161 [V]
BS T240 3 DOF Y/V = -0.294 [V]
HAM8 1 DOF X/U = -0.216 [V]

 

STS (channels averaged between 2025-08-01 15:09:20 - 15:09:30 UTC)
Averaging Mass Centering channels for 10 [sec] ...

2025-08-01 08:09:30.264056
There are 2 STS proof masses out of range ( > 2.0 [V] )!
STS EY DOF X/U = -4.662 [V]
STS EY DOF Z/W = 2.344 [V]


All other proof masses are within range ( < 2.0 [V] ):
STS A DOF X/U = -0.46 [V]
STS A DOF Y/V = -0.752 [V]
STS A DOF Z/W = -0.633 [V]
STS B DOF X/U = 0.163 [V]
STS B DOF Y/V = 0.96 [V]
STS B DOF Z/W = -0.374 [V]
STS C DOF X/U = -0.762 [V]
STS C DOF Y/V = 0.795 [V]
STS C DOF Z/W = 0.575 [V]
STS EX DOF X/U = -0.135 [V]
STS EX DOF Y/V = -0.089 [V]
STS EX DOF Z/W = 0.05 [V]
STS EY DOF Y/V = 1.196 [V]
STS FC DOF X/U = 0.198 [V]
STS FC DOF Y/V = -1.143 [V]
STS FC DOF Z/W = 0.603 [V]

H1 General
oli.patane@LIGO.ORG - posted 07:34, Friday 01 August 2025 - last comment - 08:25, Friday 01 August 2025(86129)
Ops Day Shift Start

TITLE: 08/01 Day Shift: 1430-2330 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Lock Acquisition
OUTGOING OPERATOR: Corey
CURRENT ENVIRONMENT:
    SEI_ENV state: CALM
    Wind: 9mph Gusts, 6mph 3min avg
    Primary useism: 0.06 μm/s
    Secondary useism: 0.05 μm/s
QUICK SUMMARY:

Currently relocking and in ACQUIRE_PRMI. Looks like the last lockloss at 2025-08-01 12:34UTC was probably from an earthquake

Comments related to this report
oli.patane@LIGO.ORG - 07:39, Friday 01 August 2025 (86130)

ndscope showing when we lost lock relative to the ground motion.

Images attached to this comment
oli.patane@LIGO.ORG - 08:25, Friday 01 August 2025 (86132)

15:25 UTC Back to Observing

LHO General
ryan.short@LIGO.ORG - posted 22:14, Thursday 31 July 2025 (86128)
Ops Eve Shift Summary

TITLE: 08/01 Eve Shift: 2330-0500 UTC (1630-2200 PST), all times posted in UTC
STATE of H1: Lock Acquisition
INCOMING OPERATOR: Corey
SHIFT SUMMARY: Straightforward shift with calibration sweeps run opportunistically and just one lockloss, which H1 is still relocking from due to ground motion. Currently relocking and up to ACQUIRE_PRMI.

H1 General (Lockloss)
ryan.short@LIGO.ORG - posted 21:15, Thursday 31 July 2025 - last comment - 09:07, Friday 01 August 2025(86127)
Lockloss @ 03:36 UTC

Lockloss @ 03:36 UTC after 7 hours locked - link to lockloss tool

Possibly an ETM glitch? Hard to say, but the ground was mostly calm at the time, although it's shaking more now as H1 attempts to relock.

Comments related to this report
oli.patane@LIGO.ORG - 09:07, Friday 01 August 2025 (86134)

It looks like all the QUADs suddenly moved a lot and caused the lockloss, but their movement doesn't look like it was caused by the ETMX glitch.  I'm not sure what would have caused it if the ground was calm at the time? ASC and LSC channels all look fine and I couldn't find any other evidence of an excursion.

Images attached to this comment
H1 ISC (DetChar)
sheila.dwyer@LIGO.ORG - posted 17:34, Thursday 31 July 2025 (86124)
change in the meaning of OMC-DCPD_524K channels

This morning I changed the matrix that sends DCPD ADC channels to the 524 kHz test channels that Jeff set up and described in 82686, hoping that this might be useful for following up on some of investigations that Kiet has done on violin mode contamination. 85026

Right now, I've set them up to send the 4 individual ADC channels for DCPD A to all 4 filters, so that A CH0 is A1, A CH1 is B1, A CH2 is A2, and A CH3 is B2. 

One striking thing in the first look I've taken at these spectra is that the rms is dominated by high frequency lines (and somewhat the 1kHz violin modes), 10215.3 Hz (f1) is the loudest followed by 10436.9 Hz (f2) and 8154.8 Hz (f3).  We have been wondering if a quadratic response of the ADC could explain the violin mode contamination, so I checked the 6 combinations of these frequencies, at this resolution I only see a peak at f2 + f3 = 18591 Hz. 

 

Images attached to this report
H1 CAL
ryan.short@LIGO.ORG - posted 17:18, Thursday 31 July 2025 (86125)
Broadband and Simulines Calibration Sweeps

Since there was a lockloss during the regularly scheduled calibration measurement time this morning, with Jenne's permission I dropped H1 out of observing and ran them this afternoon after H1 had been locked for 3 hours. Calibration monitor screenshot and report attached.

Broadband PCal: 23:39:04 to 23:44:14 UTC

Simulines: 23:44:56 to 00:08:12 UTC

2025-08-01 00:08:11,966 | INFO | File written out to: /ligo/groups/cal/H1/measurements/DARMOLG_SS/DARMOLG_SS_20250731T234457Z.hdf5
2025-08-01 00:08:11,973 | INFO | File written out to: /ligo/groups/cal/H1/measurements/PCALY2DARM_SS/PCALY2DARM_SS_20250731T234457Z.hdf5
2025-08-01 00:08:11,978 | INFO | File written out to: /ligo/groups/cal/H1/measurements/SUSETMX_L1_SS/SUSETMX_L1_SS_20250731T234457Z.hdf5
2025-08-01 00:08:11,983 | INFO | File written out to: /ligo/groups/cal/H1/measurements/SUSETMX_L2_SS/SUSETMX_L2_SS_20250731T234457Z.hdf5
2025-08-01 00:08:11,987 | INFO | File written out to: /ligo/groups/cal/H1/measurements/SUSETMX_L3_SS/SUSETMX_L3_SS_20250731T234457Z.hdf5

Images attached to this report
Non-image files attached to this report
H1 SQZ
sheila.dwyer@LIGO.ORG - posted 16:37, Thursday 31 July 2025 - last comment - 19:53, Friday 01 August 2025(86107)
squeezing at arm higher order modes

This is a look at the data that Camilla and TJ took in 85957, motivated by some modeling work that Kevin and Dan have been doing.  We took data to look at the squeezing rotation around the arm higher order modes, to compare to measurements that Kevin took using the ADF.  We borrowed Jeff's DCPD test matrix to create a DCPD sum channel at 524kHz, and used a modified version of Elenna's script to save 5 minutes of no squeezing data from the individual DCPDs. 85937

Process details:

The first plot here shows the spectra and cross correlation, subtraction and rebinning that I did.  We took 5 minutes of data for each of these traces, and 1 second FFTs, so we have 300 averages and the cross correlation asd should be a factor of 300^1/4 = 4 below the no squeezing asd.  (Thanks to Elenna for pointing out that I was doing this ratio for the PSD).  This is not far below the squeezing level, so when we do the subtraction of the cross correlation the squeezing data becomes noisy.  We could do this with shorter FFTs to get the cross correlation lower where the noise is uncorrelated between the two DCPDs, but we want to subtract some fairly narrow features from the spectra, so our best option if we are bothered by this noisy subtracted squeezing data would be to take a longer no squeezing time.   After doing the subtraction I rebinned the data to 3 Hz bins. 

Looking at higher order mode frequencies:

The next plot shows this data plotted in dB of squeezing, you can identify the higher order modes most clearly from looking at the mid squeezing data where the higher order modes cause a rotation of the squeezing angle. Zooming in on 10 kHz you can identify the higher order mode frequencies as roughly 10615+/5 Hz and 10565+/- 10Hz from the X arm modes (see 84172 for ID with X arm), with the uncertainty based on what I can place as limits by eye, which is worse for the lower mode.  The separation of these into different peaks means that there is some astigmatism in the X arm.  The y arm mode has much more correlated noise to subtract, and is sitting right under the forest of accoustic modes, but you can still see evidence of a rotation starting around 10.25kHz.  This data isn't clear enough to estimate if there is similar evidence of astigmatism in the y arm.  

Zooming in around 5kHz, we can see that there do seem to be two modes with rotations, one of them is sitting on top of a set of lines, but seems to be narrower than the other.  The broad mode is at  5345+/- 15 Hz Hz and the narrower one is at 5184+/- 4Hz .  Assuming that the second one is from the X arm based on the identification of the 2nd order modes, the second order mode frequency is 98.8+/- 0.3% of twice the first order mode frequency for the lower mode, and 99.3% +/-0.3% for the upper mode. This ratio is not 1 because the beam size of the 2nd order modes is slightly bigger than for the 1st order mode, since the mirror is non spherical its curvature is sightly different for the larger sized beam, so these ratios contain some information about how non spherical the mirrors are.

Squeezing loss and rotation estimates:

We can use this data to estimate a loss an rotation expirienced by the squeezing at these higher order modes.  Using the mean squeezing data, where the squeezing angle is completely uncontrolled, and Camilla's measurement of the nonlinear gain of 13.8 we can estimtae the total squeezing efficiency (using the notation from Aoki): 

  • eta = (R_mean-1)/[2*x*(1/(1-x)**2-1/(1+x)**2)]
  • x = 1 - 1/np.sqrt(NLG)
  • R_mean = ratio of PSD with mean sqz over no sqz (varience)

Using this estimate we can predict the anti-squeezing level, which is mostly insensitive to squeezing angle, this prediction is plotted in the dark blue on the dB plot, where it agrees nicely with the measured anti-squeezing.

We can also make an estimate of the rotation using the mid squeezing data where we have about 5dB of anti-squeezing. To do this, I first fit the average squeezing angle for these measurements using data from 6.3kHz to 7.8kHz, using the Aoki equation:

  • R = R_p sin^2(theta) + R_m cos^2 theta
  • Rp = 1+4*x*eta/(1-x)**2 ;
  • Rm = 1-4*x*eta/(1+x)**2
The squeezing angle for the negative side is -18 degrees, the positive side is 16 degrees.  Taylor expanding the varience around this squeezing angle gives: 
R = R(average angle) + 2*np.sin(theta)*np.cos(theta)*(Rp-Rm) * delta theta
 
The 5th plot here shows the loss and rotation inferred in this way for both 5kHz and 10kHz modes.  The estimate of the rotation is slightly impacted by the frequency dependent loss, the rotation angle estimated using the frequency dependent efficiency is a little bit larger than if we use the average efficiency. 
 
The last two plots show the loss and rotation zoomed in around the 2nd order mode. The final plot is the same as the second to last, but in this case I've flipped what I've used for a starting gues in the squeezing angle, so that the trace we've been calling positive mid squeezing has a negative squeezing angle and the one called negative has a postive angle, in this case the rotation estimate goes in the opposite direction.  If we were to look at the data at frequencies where the radiation pressure starts to matter, we could distinguish which of these is the correct model.
 
 
Images attached to this report
Comments related to this report
kevin.kuns@LIGO.ORG - 19:53, Friday 01 August 2025 (86141)

We got three good sets of ADF measurements targeting the two X arm modes. One was taken before the ETMY ring heater was changed (85514) and two were taken after. The gps start times of the upper sideband sweeps for each of these measurements are

pre-RH change      1433785394
post-RH change 1 1436198864
post-RH change 2 1436809945

There are difficulties in calculating all of the squeezing metrics described in the ADF paper (PhysRevD.105.122005), but the squeeze angle is relatively straightforward to calculate using equations (26), (33), and (34) of that paper. (All of the lower sidebands in those equations should be the conjugates of the lower sidebands.) The first plot shows the inferred squeeze angle for these three measurements along with the DCPD spectra for those times. These are consistent with what you would expect for the rotation generated from an astigmatic arm cavity and can probably be fit with a bit more work. The flat line above 10.6 kHz in the post-RH change 2 rotation is because we lost lock at the end of that measurement. The rotation is fairly constant which isn't surprising since the Y arm modes were mainly changed by the ETMY RH change. The change in the DCPD is likely due to a change in the laser noise coupling independent of any squeezing effects.

The second plot compares these measurements with the ones that Sheila measured above. The data is noisy and there's about a 10 deg variation between the rotation inferred from mid SQZ + and mid SQZ - around the second peak but the mid-SQZ + magnitude and the mid-SQZ- frequency dependence are fairly consistent with the ADF measurements. Uncertainty in the NLG will propagate to uncertainty in the magnitude of the rotation in both cases.

These plots can be made by running the following in the aligoNB environment

pytest /ligo/gitcommon/squeezing/sqzutils/analysis/T_10kHz_ADF.py -s -k T_compare_10kHz

Images attached to this comment
H1 SEI (ISC)
jim.warner@LIGO.ORG - posted 15:20, Thursday 31 July 2025 - last comment - 17:22, Thursday 31 July 2025(86120)
HAM8 H1 gs13 causing .4-ish hz peak again, digital gain got reverted during vent

Last year we found that a problem with the H1 GS13 was causing a .375hz feature in the motion of the table which showed up in the filter cavity. The root issue was a GS13 having a low gain compared to the other sensors. I was able to compensate by  adding a digital gain of 2. During the vent, this gain got reverted at some point and the sdf accepted. I didn't fix this when I found it because it didn't seem to be causing the same issue, but it seems the feature has now returned.  Doesn't seem to be causing problems for the filter cavity that I've heard of, but the ISI and SUS definitely see this feature. 

First image are the side osems for FC2 while the IFO was locked, the crosshair is at .375hz, similar to what we saw in the past. 

Second image is the HAM8 summary page for today, the .375hz feature is clearly visible while the ISI is isolated.

Third image are l2l tfs for each co-located gs13/cps pair, the red trace shows the magnitude of this tf is almost exactly half the other 2 gs13/cps pairs, above 1 hz. 

I will try to fix this next Tuesday, but if the filter cavity is having problems,  caput H1:ISI-HAM8_GS13INF_H1_GAIN 2 in a terminal and then accepting the sdf diff should fix the issue.

Images attached to this report
Comments related to this report
camilla.compton@LIGO.ORG - 16:37, Thursday 31 July 2025 (86123)OpsInfo, SQZ

The filter cavity has been having locking issues, the operators were tieing sometimes to high wind 85169 or low green power 85395:

It would be great if we can fix this on Tuesday.
Tagging Opsinfo for Jim's suggested change if the FC has issues before then. 
ryan.short@LIGO.ORG - 17:22, Thursday 31 July 2025 (86126)OpsInfo, SQZ

After running calibration sweeps this evening and while H1 was still out of observing, I updated the GS13 gain as Jim describes above. The filter cavity saw some motion after I did this, but after a minute or two, things settled back out. I then accepted the SDF diff (screenshot attached) and took H1 back to observing.

Images attached to this comment
Displaying reports 5481-5500 of 89162.Go to page Start 271 272 273 274 275 276 277 278 279 End