I woke up, with my alarm clock and started an initial alignment since H1 needed assistance. Around 6am.
Once
Going throught the locking proccess now.
TITLE: 07/14 Eve Shift: 2330-0500 UTC (1630-2200 PST), all times posted in UTC
STATE of H1: Wind/Aligning
INCOMING OPERATOR: Tony
SHIFT SUMMARY: The TCSY laser tripped off then we lost lock in the last hour, the winds rose to around 40mph after this. H1 is trying to do an intial alignment as of 05:00 UTC as the DRMI flashes weren't great, the winds have calmed a bit so hopefully it goes well and the arms can stay locked.
LOG: No log.
TCS CO2Y tripped and dropped us out of Observing at 03:58 UTC then we lost lock 2 minutes later, lockloss. The lockloss appears to have been an ETMX glitch.
The pumps were still running last month when I suggested preliminary CP-Y settings (85084). I wanted to get back to it with a little higher sensitivity after the pumps were shut off. As a result of this second look, I suggest new settings of Pitch: -317 and Yaw: -122; They represent only a slight reduction in scattering noise coupling, but the new settings don't consume as much actuator range.
The technique I used to pick a minimum was the same as used here: https://alog.ligo-wa.caltech.edu/aLOG/uploads/76969_20240404184914_Fig3-Sensitivity-To-IY-CP-Yaw-Also-Bright-Spot.pdf
The structure in the coupling variation was like it was before the break (see link), at a scale of about 20 microradians in CP angle. The maximum coupling in the CP sweeps after the vent was about half of what it was in the sweeps before the vent, so maybe there was some improvement.
I made videos of the beam spot on the HAM3 ballast baffle and its support before and after the compensation plate adjustment. The compilation video uses the same slider program (see details in video description) before and after the compensation plate move:
TITLE: 07/13 Day Shift: 1430-2330 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Observing at 146Mpc
INCOMING OPERATOR: Ryan C
SHIFT SUMMARY: Major excitement of the day was a lockloss caused by a power glitch which necessitated a recovery of end station HEPI pump controllers. Aside from that, calibration sweeps were run opportunistically and relocking went very smoothly.
TITLE: 07/13 Eve Shift: 2330-0500 UTC (1630-2200 PST), all times posted in UTC
STATE of H1: Observing at 146Mpc
OUTGOING OPERATOR: Ryan S
CURRENT ENVIRONMENT:
SEI_ENV state: CALM
Wind: 14mph Gusts, 8mph 3min avg
Primary useism: 0.03 μm/s
Secondary useism: 0.07 μm/s
QUICK SUMMARY:
We dropped observing from 23:30 - 23:38 UTC as the SQZ PMC lost lock, I also ran a SCAN_SQZ ang
Lockloss @ 18:53 UTC from site power glitch, trend attached. This tripped the end station HEPI pump controllers (and so far nothing else, that I've noticed), so I consulted with Jim and he walked me through what needs to be done to reset them. Heading out to the end stations now.
Pump stations and all seismic systems fully recovered. Starting an initial alignment now.
H1 back to observing at 21:50 UTC. Initial alignment and lock acquisition both ran fully automatically and without issues.
Note that none of the UPS units emailed us regarding this event, which is unusual for a glitch which caused HEPI pump controller issues.
Jonathan checked the front panel on the MSR UPS and confirmed it logged nothing at the time of this power glitch.
After running calibration sweeps this morning while L1 was out of lock, I also took the opportunity to touch up the OPO temperature with the SQZ_OPO_LR Guardian as I noticed the range gradually decreasing over this lock stretch. This went well, improving CLF_REFL_RF6 a bit and gaining H1 about 6-8Mpc of BNS range.
H1 returned to observing at 18:19 UTC.
Since the scheduled calibration time was missed yesterday due to a lockloss, while L1 was out of lock this morning, I took the opportunity to drop observing at 17:38 UTC and run the broadband and Simulines sweeps. Calibration report and screenshot of the calibration monitor screen are attached.
Broadband: 17:39 to 17:44 UTC
Simulines: 17:45 to 18:08 UTC
2025-07-13 18:08:34,702 | INFO | File written out to: /ligo/groups/cal/H1/measurements/DARMOLG_SS/DARMOLG_SS_20250713T174519Z.hdf5
2025-07-13 18:08:34,709 | INFO | File written out to: /ligo/groups/cal/H1/measurements/PCALY2DARM_SS/PCALY2DARM_SS_20250713T174519Z.hdf5
2025-07-13 18:08:34,714 | INFO | File written out to: /ligo/groups/cal/H1/measurements/SUSETMX_L1_SS/SUSETMX_L1_SS_20250713T174519Z.hdf5
2025-07-13 18:08:34,719 | INFO | File written out to: /ligo/groups/cal/H1/measurements/SUSETMX_L2_SS/SUSETMX_L2_SS_20250713T174519Z.hdf5
2025-07-13 18:08:34,723 | INFO | File written out to: /ligo/groups/cal/H1/measurements/SUSETMX_L3_SS/SUSETMX_L3_SS_20250713T174519Z.hdf5
Sun Jul 13 10:08:24 2025 INFO: Fill completed in 8min 20secs
TITLE: 07/13 Day Shift: 1430-2330 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Observing at 145Mpc
OUTGOING OPERATOR: Tony
CURRENT ENVIRONMENT:
SEI_ENV state: CALM
Wind: 5mph Gusts, 2mph 3min avg
Primary useism: 0.01 μm/s
Secondary useism: 0.09 μm/s
QUICK SUMMARY: One lockloss overnight with an automatic recovery. H1 has now been locked and observing for 5 hours.
05:09 UTC lockloss
TITLE: 07/13 Eve Shift: 2330-0500 UTC (1630-2200 PST), all times posted in UTC
STATE of H1: Lock Acquisition
INCOMING OPERATOR: Tony
SHIFT SUMMARY: A lockloss towards the end of the shift and right after relocking.
LOG: No log
I've added the damping settings I found the other day (FM1+FM2+FM10 G=-50) into lscparams after seeing it work for many lock stretches, the VIOLIN_DAMPING GRD could use a reload to see this change.
I took some high resolution spectra in the 1460 - 1500 bandwidth of DARM to look at the second harmonic violin mode region, all of these might not be violin modes. I found 5 over 10^-16, 1468.4961 1472.7793, 1481.9717 (monitor filter on ETMY mode19), 1492.0198, and 1497.1934 (the worst offenders), these were reduced to 3 when I took another spectra with a smaller bw an hour later. There were also several above 10^-17, 1464.5293, 1464.0234, 1467.3916 1468.5879, 1471.2969, 1471.7012, 1472.9668, 1482.0117, 1494.3535, 1494.3711, 1499.5937, 1500.4248. The frequencies I saw don't match the old ones reported in the wiki's violin mode table or in T1800327 but I believe these documents were from pre-O3.
Lockloss 02:56 UTC from an ETMX glitch just under 1/4 of a second before the LL
Following the WIKI and TJ's instructions I went into the LVEA (TJ was my phone buddy) to restart the controller than I went into the mechanical room and reset the power supply which was reading a current and voltage of 0 when I arrived. There were no flow/chiller alarm nor RTD/IR sens alarm.