TITLE: Nov 25 Owl Shift 08:00-16:00UTC (00:00-08:00 PST), all times posted in UTC
STATE Of H1: Observing at ~80 Mpc
LOCK DURATION: 7 hrs 4 mins
INCOMING OPERATOR: Cheryl
END-OF-SHIFT SUMMARY: Useism is slowly decreasing. Wind is still at 20-30 mph. Otherwise quiet night.
Activity Log:
8:22 BS ISI ST2 tripped
8:35 Kyle on site going to X2-8 to refill the generator.
9:08 Kyle left
Still observing at ~75 Mpc. Useism reads 2e-1 um/s. Wind speed 20-30 mph.
I have attached the screenshots of all the SDF I accepted. I accepted all the changes with the ISI and accepted the old ASC gains since they were decreased to help with the 45mHz instability (from what I uderstand). We are using 90mHz blend everywhere at the moment. I forgot to take a screenshot of ETMX ISI changes but it's the same as ETMY. I've also attached the screenshots of ground motion and wind monitor when the IFO was locked. ETMX violin mode at 505.707Hz seems higher than usual. I'm keeping an eye on it. The amplitude seems to be decreasing slowly. I'm playing a violin in the control room and playing Pan's Labyrinth album on the big speaker (violin-heavy. only half as loud as Robert's injection).
Ops Day Shift: Nov 23rd 2015 0:00-8:00UTC
State of H1: unlocked, wind and microseism making locking difficult
Assisstance today: Jenne, Evan, Jeff
Summary:
An earthquake early on kept us from locking, then winds and microseism. Currently ALS won't stay locked, finding IR is barely possible. I've tried several permutations of ISI configurations, but nothing has helped much. Currently running 90mhz blends everywhere, as that was the best until about 20 minutes ago.
So far no locking tonight. First part of the shift we were waiting for an earthquake to ring-down. Now winds in the 30-40 mph range and moderate microseism are making locking difficult. Jenne is attempting to do some stuff by hand, but the environment doesn't show any signs of settling down.
DCS replaced the main samfs filesever today during maintenance. This took longer than expected, with restarts of Disk2Disk, rds and aggregegated hoft generation occuring around 2 pm PST, and all services restored by 5 pm PST. All DCS services seem to be running fine now. However, the detchar summary pages have not caught up yet and I've emailed Duncan Macleod about this.
J. Kissel Regular Teusday measurements. All 5 measurements complete for both test masses, but I had had a bunch of trouble with NDS returning data gaps that broke the multi-nested set of functions that analyze the data in ways that varied with measurement and even within the data gathering of one measurement. As such, I was only able to process 1 ETMX measurement and 3 ETMY measurements. However, even with that little of measurements, we can still see that the charge continues to trend as expected. The effective bias voltage for ETMY has just crossed zero, on its way to more negative, and continuing to at at rate that is consistent with us needing to flip the bias again in late December. Will work with Stuart and the NDS crowd to try and make data gathering more robust.
there have been 3 testpoints open on PSL PMC for many days, I have just cleared them.
I have compiled and installed all the SUS IOP models against RCG-2.9.7. The next time these models are restarted, they will run with 2.9.7 code which latches any DAC errors and delays the triggering of DACKILLs by DAC errors by one second. Only the SUS IOP models which control 18bit DACs have been built against 2.9.7. The default build area continues to be 2.9.6.
Ops Day Shift: 16:00-00:00UTC (08:00-16:00PT)
State of H1: unlocked, recovering from an earthquake, not yet able to lock, IMC and IFO set to Down
Assisstance today: Jenne, Kiwamu, Jeff, Ed, Hugh
Summary:
Relevant alogs:
Next fill ~ 0030 hrs. tonight
Dave, Jim We modified the /etc/init.d/psinject script on h1hwinj1 to ramp the gain on the H1:CAL-PINJX_CW filter from 0 to 1 over a 10 second interval when starting psinject. Similarly, there is a ramp down of the gain from 1 to 0 over a 10 second interval when stopping psinject. Although this does not prevent a transient if psinject dies unexpectedly, it does help when Monit restarts the process. Since the /etc/init.d/psinject takes longer to finish execution, we also changed the /etc/monit.d/psinject file to include longer timeouts. Modified files are included as attachments. We tested the revised setup by starting and stopping the psinject using Monit and /etc/init.d/psinject, and while under control of Monit, we tested killing the psinject process to ensure that Monit would restart it. Since the scripts now set the gain and ramp time of the filter, we also changed the SDF file to no longer monitor the channels to avoid problems from SDF differences. We left the CW injection running.
I have modified the CDS O1 overview MEDM to make calex a hardware injection system and made the calcs a standard, non-hardware injection system. This means that calex is green when the CW injection is running, and calcs is green when no injections are running.
Guardian will still permit excitations in either calex or calcs and keep the IFO in observation mode. If we are to no longer run any hardware injections to calcs, we may want to remove it from the exception list.
Earthquake data:
Time: Tue Nov 24 22:45:37 UTC 2015
Location: 173km WNW of Iberia, Peru; LAT: -10.6, LON: -71.0
Magnitude: 7.5
Activities during maintenance:
- Bubba and Chirs clearing roads and walkways
- PSL REF CAV alignment, Peter, Ed, Jason
- Sprague, checking traps all buildings
- MikeL called, watch for SNEWs alert at 9:00 and G-wave alert at 9:05
- US Linen delivery
- Jodi in LVEA, 3IFO
- Gerardo, in LVEA, 3IFO
- charge measurements on ETMs, JeffK
- Hugh, HEPI checks all buildings, and in CER
- Filiberto in LVEA, checking racks
- Sprague, ChrisS escorted to LVEA
- 18:10UTC, I put all IMs in Safe Mode, free swinging
- 18:53UTC realigned and damped, except IM1, as noted in my Update Log
- paradice water
- wifi off, Hugh out of the LVEA
- Hugh to EY hepi, ISI tripped
- Hugh to EX, STS rezero
- Chris Biwer, done with CW injection changes
- cleared CDS CRC error
- LVEA sweep - all clear
Title: Ops Day Shift - Mid-shift Update, 22:22UTC
State of H1: lock in DRMI when I started my alog, now in Low Noise
Assistance: Kiwamu, Jenne, Ed
Summary: Y arm alignment has been very sensitive to ETMY alignment, and has needed special attention a couple times today.
Details:
In locking the arms in green, after maintenance, I was able to get Y arm to 0.85 in power, but that alignment was not good for green WFS, so killed the arm.
I chased the changing alignment every time WFS engaged even briefly.
Kiwamu and Jenne diagnosed this as a WFS issue, and driving the WFS issue is was a misalignment in ETMY.
I was able to get the power in the Y arm up to 0.85, however that was optomized for a beam path in the Y arm that wasn't what the WFS wants.
After the Y arm green alignment / locking was corrected and WFS engaged, I offloaded the green WFS and started an initial alignment.
After the initial alignment was complete, the Y arm was again an issue, locking at 0.4.
Again Kiwamu alighned the Y arm, and this time using only ETMY, and arm powers and WFS centering were good.
OMC needed it's WFS cleared.
ISS Second Loop needed to be engaged by hand.
I continued the locking, and currently the IFO is in Low Noise.
- IM1 was found to be not damped, aligned but not damped, and the damping was re-engaged while in Low Noise and the lock survived.
This was a error state that occured after I had all IMs undamped earlier today. Not sure why Guardian didn't re-engage the damping. I only used Guardian to control the IMs, so it seems possible that there's an issue with commands for IM1. This should be tested.
- 22:58UTC, Low Noise lock loss - IFO was oscillating and JeffK tried to intervene, however an earthquake arrived and broke the lock.
LLO had called and said they would be down for awhile. I'm going to finish doing a swept-sine through the INJ_HARDWARE filterbank from 5-500Hz. Previously I had only finished 500-2000Hz. The IFO intent mode has been turned off. This is WP#5595.
Previous swept-sine measurement was: aLog 23307 The following was done: * psinject turned off at 5:20 UTC * swept sine measurement started at 5:21 UTC * swept sine measurement ended at 5:48 UTC * psinject turned on at 5:49 UTC I've attached a plot of the transfer function and coherence between INJ_CW and DELTAL_EXTERNAL_DQ. WP#5955 is now complete.
Attached are results of computing a transfer function from H1:CAL-INJ_CW_OUT to H1:GDS-CALIB_STRAIN, using the same method used for the higher-frequency swept sine on Nov 11. The transfer function is generally flat and well behaved below 500 Hz and above ~35 Hz. The feature at 167 Hz appears to be an artifact of the swept sine measurement at that point being artificially split into several points. Figure 1 - Spectogram of H1:CAL-INJ_CW_OUT during swept sine Figure 2 - Spectogram of H1:GDS-CALIB_STRAIN during swept sine Figure 3 - Transfer function and coherence More detailed results can be found here.
The DTT template for doing the 5 to 500Hz swept-sine measurement is in the SVN here: template_cw_inj_sweptsine_5to500_20151121.xml The DTT template for doing the 500 to 2000Hz swept-sine measurement is in the SVN here: template_cw_inj_sweptsine_500to2000_20151111.xml