Displaying reports 7141-7160 of 89074.Go to page Start 354 355 356 357 358 359 360 361 362 End
Reports until 12:46, Monday 12 May 2025
H1 ISC
camilla.compton@LIGO.ORG - posted 12:46, Monday 12 May 2025 - last comment - 13:39, Wednesday 14 May 2025(84361)
ISC Alignment Work, Day 9 in HAM1 (May 12th): BeamDivs, POP Diodes

Sheila, Betsy, Tyler, Oli, Jennie, Camilla, 

Day 1: 84193, Day 2: 84228, Day 3: 84230 and 84239, Day 4: 84274, Day 5: 84292, Day 6: 84314, Day 7: 84334

POP/REFL: After the changes to the POP and REFL paths on Friday 84334, Betsy and I confirmed that the distance between the central and edge viewports is 22.5 to 23.5" on both the HAM1 door and VP simulator. We again checked the beams were easily making it though the VP simulator (attached).
Sheila and I installed and cabled the two beam divertors (REFL and POP), these are in different locations than the design to account for the close beams.
Daniel will swap the logic of the REFL divertor, POP is fine as is. Photos below:
Photos attached of: REFL (BDV1) POP (BDV2)
Location                                 photo
Open Position photo photo
Closed Position  photo photo
Beamdump Location  photo photo
Beamdump Name BD5 BD4
Beam dumped  photo photo

PSL ALS: we decided that the PSL ALS path was too close to the edge to the VP (84334) we tried moving M13 so the beam traveled in-between M11 and L2 but this didn't give enough separation at the bottom pericope mirror of ISCT1. We then put M1 back to a similar position to wear we started an decided that it was good enough away form clipping the VP. Photos attached of M15 locationbeam on M15, beam next to L2, VP simulator, UPM, LPM.

Images attached to this report
Comments related to this report
daniel.sigg@LIGO.ORG - 13:00, Monday 12 May 2025 (84362)

The logic of the REFL diverter has been changed to alternate beam. This required a restart of the slow controls software.

camilla.compton@LIGO.ORG - 17:13, Monday 12 May 2025 (84369)

Before lunch, Tyler, Oli and Betsy removed ISCT1 and the VP simulator. 

POP Beam to diodes: 

Jennie and I aligned the POP beam onto the POP X ASC diode (using flashes then single bounce, with 20W in). We needed to adjust the dark offsets (they are about the same size as the 1.5uW single bounced beam), sdfs accepted in safe attached, properly need to be redone and saved once we get to observe. All segments responded to the beam and a flashlight and we centered the beam in pitch and yaw using PM1 (alignment sliders P:100, Y:50).

Elenna and I aligned the POP beam onto the POP A LSC diode (using flashes then single bounce). We checked the POP LSC picomotor was working as expected. Checked beam was centered on the diode by it was centered by going to the middle of the edges of the diode. All segments responded to the beam and a flashlight and we centered the beam in pitch and yaw using PM1, ndscope. Note that we'll want to check this again tommor0w as we need to offload the picomotor in yaw as it doesn't have much range left. 

We couldn't see the didoe reflected beams (using POP flashes, sensitive IR card and IR viewer) so I dead rekon'ed the positions of beam dumps BD1 and BD2, see attached photo. 

Leaving IMC locked with 2W in. 

Still to do: offload POP LSC pico and check alignment, place BD6a, 6b, 7, 9 (couldn't see beams easily tpday at 2W), final checks (see other alog). 

Images attached to this comment
jennifer.wright@LIGO.ORG - 13:39, Wednesday 14 May 2025 (84393)EPO
LHO VE
david.barker@LIGO.ORG - posted 10:36, Monday 12 May 2025 (84360)
Mon CP1 Fill

Mon May 12 10:11:32 2025 INFO: Fill completed in 11min 28secs

 

Images attached to this report
LHO VE
jordan.vanosky@LIGO.ORG - posted 09:48, Monday 12 May 2025 (84359)
Morning Purge Air Checks 5-12-25

Dry air skid checks, water pump, kobelco, drying towers all nominal.

Dew point measurement at HAM1 -43.8 °C.

Images attached to this report
H1 PSL
ryan.short@LIGO.ORG - posted 09:19, Monday 12 May 2025 (84357)
PSL 10-Day Trends

FAMIS 31085

The brief time in the enclosure 4 days ago to adjust the ALS path shows clearly on trends, and since then the FSS TPD looks to be a bit noisier for some reason. No other events of note this week.

Images attached to this report
LHO General
ryan.short@LIGO.ORG - posted 07:49, Monday 12 May 2025 (84354)
Ops Day Shift Start

TITLE: 05/12 Day Shift: 1430-2330 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Planned Engineering
OUTGOING OPERATOR: None
CURRENT ENVIRONMENT:
    SEI_ENV state: MAINTENANCE
    Wind: 1mph Gusts, 0mph 3min avg
    Primary useism: 0.01 μm/s
    Secondary useism: 0.17 μm/s
QUICK SUMMARY: Systems appear to be fully recovered after the h1susb123 crash and output arm turbopump shutoff this weekend. More vent work planned for today includes wrapping up HAM1 alignment and more wind fence work at EX.

LHO VE (VE)
gerardo.moreno@LIGO.ORG - posted 02:45, Monday 12 May 2025 (84353)
Output Tube Main Turbo Pump Off

I noticed that the pressure in the LVEA spiked up several hours ago, see attachment, typical behavior of a turbo pump turning off.  Drove to the site and found the output tube main turbo pump off, this system was isolated from the main volume first, then the turbo system was restored; scroll pump running, small turbo up to speed, and main turbo pump up to speed, only then the turbo system was valved in to the main volume.  Nothing out of the ordinary was found or noted.  As of now no power glitches have been reported.

Images attached to this report
H1 CDS
david.barker@LIGO.ORG - posted 16:31, Sunday 11 May 2025 - last comment - 09:21, Monday 12 May 2025(84348)
h1susb123 crash, SWWD shutdown of h1seib1,2,3

At 15:36:55 Sun 11may2025 PDT all models on h1susb123 stopped due to an ADC/Timing error.

h1susb123 DMESG output:

[Sun May 11 15:36:49 2025] rts_cpu_isolator: LIGO code is done, calling regular shutdown code
[Sun May 11 15:36:49 2025] h1iopsusb123: ERROR - An ADC timeout error has been detected, waiting for an exit signal.
[Sun May 11 15:36:49 2025] h1susitmpi: ERROR - An ADC timeout error has been detected, waiting for an exit signal.
[Sun May 11 15:36:49 2025] h1susitmy: ERROR - An ADC timeout error has been detected, waiting for an exit signal.
[Sun May 11 15:36:49 2025] h1susbs: ERROR - An ADC timeout error has been detected, waiting for an exit signal.
[Sun May 11 15:36:49 2025] h1susitmx: ERROR - An ADC timeout error has been detected, waiting for an exit signal.
(diskless)controls@h1susb123:~$ 
 

Images attached to this report
Comments related to this report
david.barker@LIGO.ORG - 16:45, Sunday 11 May 2025 (84349)

If I do a "sudo lscpi" this command freezes for about 30 seconds, then eventually returns. While it is frozen, the EDC disconnects from h1susb123 EPICS channels.

This is a 8-core W2245 machines with 5 models, so 3 general purpose cores. The IOC disconnect suggests the lscpi command is taking over all 3 cores.

Interestingly h1iopsusb123 is not in a DACKILL state, its DAC drives are non-zero, frozen at their last values (see attached).

The IPC senders have stopped updating, causing IPC receive errors downstream and SEI SWWD trips.

Images attached to this comment
david.barker@LIGO.ORG - 17:02, Sunday 11 May 2025 (84350)

System has been recovered by power cycling the front-end computer, no IO Chassis restart was needed.

Procedure:

  • Fence h1susb123 from Dolphin fabric
  • Stop all models
  • Power down h1susb123, wait a few minutes
  • Power h1susb123 back up using IPMI.

"rtcds showcards" sees all the ADC/DAC/BIO cards in the IO Chassis. 

"sudo lscpi" completes immediately, no 30 second freeze.

david.barker@LIGO.ORG - 17:03, Sunday 11 May 2025 (84351)

I have untripped the SWWDs (SUS and SEI) for BSC1,2,3.

I have not ununtripped any user model watchdogs, will hand over to control room for that.

thomas.shaffer@LIGO.ORG - 19:14, Sunday 11 May 2025 (84352)

I've brought the BS, ITMX, ITMY suspensions back to Aligned after untripping the user WD. I also untripped the sei for those and watched them go back to nominal. All looks good.

david.barker@LIGO.ORG - 08:12, Monday 12 May 2025 (84355)
david.barker@LIGO.ORG - 09:21, Monday 12 May 2025 (84358)

Sun11May2025
LOC TIME HOSTNAME     MODEL/REBOOT
16:52:48 h1susb123    ***REBOOT***
16:55:12 h1susb123    h1iopsusb123
16:55:25 h1susb123    h1susitmy   
16:55:38 h1susb123    h1susbs     
16:55:51 h1susb123    h1susitmx   
16:56:04 h1susb123    h1susitmpi 

LHO VE
david.barker@LIGO.ORG - posted 10:17, Sunday 11 May 2025 (84347)
Sun CP1 Fill

Sun May 11 10:11:51 2025 INFO: Fill completed in 11min 47secs

 

Images attached to this report
LHO VE
david.barker@LIGO.ORG - posted 10:15, Saturday 10 May 2025 (84346)
Sat CP1 Fill

Sat May 10 10:10:22 2025 INFO: Fill completed in 10min 18secs

 

Images attached to this report
H1 CDS
david.barker@LIGO.ORG - posted 13:33, Friday 09 May 2025 - last comment - 08:47, Monday 12 May 2025(84335)
CDS Rack power strip current draw EPICS IOC

I've written an EPICS IOC which reads the smart Geist rack power strips and records their current draw in Amps.

CDS racks in the MSR and end stations have two verically mounted, full height, power strips. Most MSR racks have a UPS power strip and a facilities power strip. Rack mount servers with dual redundant power supplies are connect to each power strip for fault tolerance. The MSR exceptions are racks 01 (fiber rack, has a single APC power strip) and the front end racks 03, 04 which have 3-phase power strips with no network connection. Front end computers are not UPS powered because their IO Chassis are also not UPS powered.

The end station racks have two power strips, but they are both on technical power, there are no FE UPS units in the outbuidings.

I have created an MEDM called H1CDS_PWR_STRIP.adl, it can be opened from the CDS pulldown on the SITEMAP.

The IOC calculates the total rack current draw, which is displayed in the circle. UPS power strips are denoted by their orange background.

Attached photograph shows a typical power strip configuration at the rear of a CDS rack, with the UPS strip using keyed outlets to prevent accidental connection to non-UPS outlets.

Images attached to this report
Comments related to this report
david.barker@LIGO.ORG - 08:47, Monday 12 May 2025 (84356)

I forgot to credit Cyrus Reed who installed these smart power strips and put them onto the network many moons ago.

H1 ISC
keita.kawabe@LIGO.ORG - posted 13:14, Friday 09 May 2025 - last comment - 13:41, Wednesday 14 May 2025(84334)
POP path alignment, Friday morning (Tyler, Betsy, Camilla, Sheila, Keita)

We ended up using pico in HAM3 to bring down green ALS beam as well as IR POP rather than raising the top periscope mirror after confirming that it was safe to do so.

We first confirmed that the X arm and corner alignment were still the same as yesterday. X arm was still locked to 00 green, and when I misaligned PRM the IR flash in H1:LSC-TR_X_IN1 was reaching 0.8 or more.

We convinced ourselves that the alignmernt was reasonable and probably similar to the alignment before the vent, that the ALS beams were pretty high but was still hitting the top periscope mirror before just like ALSX beam is as of now. We discussed the use of the pico in HAM3 (instead of moving the top periscope mirror up) and decided that it's OK to do so as far as the IR beam is far from clipping somewhere in HAM2.

We moved the HAM3 pico for PIT in "Down" direction by 700 counts and the IR beam position looked about right. We moved the pico further down by 1000 counts (that's the total of 1700 counts down from the initial state) and the IR beam missed the bottom of the top periscope mirror but no sign of clipping in HAM2, so we were comfortable to go 1000 counts "UP" and search for an optimum positision. In the end we ended up going back to 700 counts "Down" relative to where we started.

Sheila and Camilla adjusted top and bottom periscope mirror. M10 (dichroich) was also touched up. Steering mirrors for in-air beams were also roughly adjusted, These are M7 (for REFL air), M11 (for green ALS), M13 (for IR ALS beam from the PSL) and M16 (for POP air).

Now we're ready to move ISCT1L in position to confirm that all beams hit the periscope mirrors on the table.

 

Comments related to this report
camilla.compton@LIGO.ORG - 13:56, Friday 09 May 2025 (84338)

Photos attached of the Green X-arm and POP beams on the HAM1 top periscope mirror before the HAM2 pico-ing and after the HAM2 pico-ing in the final position

Tyler fork-lifted ISCT1 into position and we correctly set the height. There was some confusion due to a typo by me on the -X-Y corner height measurement that we've now corrected.

PSL ALS and Green ALS Beams:

To get the PSL ALS and green ALS beams through the VP simulator and onto the top periscope mirror, Sheila needed to move both final steering mirrors (M11 and M13) to have the beams more centered on the VP simulator:

  • M11 (for green beams) was moved in +X. We had to carefully think about not centering the alignment of this beam on all mirrors as the Y-arm green beam will be ~8mm on the -X side of the X-arm beam. 
  • M13 (for the PSL ALS) was moved in -X, ideally we'd have moved it more to further center on the VP but it would have clipped on L2. 

Photos of the final positions attached, on the VP simulator (inner red circle is the location of the actual window),  on the upper periscope mirror, on the lower periscope mirror and on the ALS shutter, we expect to need to do some steering of the UPM to get the final beams better on the LPMs, this will be done once ISCT1 is installed and realigned. 

Images attached to this comment
keita.kawabe@LIGO.ORG - 21:18, Friday 09 May 2025 (84344)

POP air and REFL air alignment
(Note: At this point, HAM1 drawing https://dcc.ligo.org/D1000313-v19 was not useful for exact placement of the mirrors because, as was reported earlier, POP and REFL beam position coming from HAM2 into HAM1 are different from what the drawing suggests by an inch or so. )

POP air steering mirror (M16) had to be relocated closer to the periscope, otherwise the POP air beam hit the -X edge of the viewport simulator when we tried to center POP air on the periscope mirror on ISCT1. But then the REFL air beam became close to the M16 mirror mount, so we ended up moving M16 MUCH closer to the periscope and the REFL air steering mirror (M7) got further down in -X direction. As a result, two beams now crosses with each other inside the chamber. See the first attachment where the new POP air beam is in orange and the new REFL air path is in cyan. This is for illustration purpose only.

2nd attachment: Overview of the POP and REFL air path in chamber.

3rd and 4th attachment: Detailed location of M16 and M7, respectively.

5th attachment: REFL air beam is comfortably away from the M16 mirror holder.

6th attachment: Beam position on the viewport simulator. Dimmer beam is POP air.

7th and 8th: REFL and POP beam on the top periscope mirror of ISCT1.

This means that the beam diverters WILL have to be relocated and reconfigured.

Just swapping the positions might not work.

I wonder if using one diverter at the edge of the table will catch both beams. (That's not a good idea as we might want to use in-air POP WFS if in-vac one doesn't work well.)

 

Images attached to this comment
keita.kawabe@LIGO.ORG - 23:16, Friday 09 May 2025 (84345)

Distance from POP air steering mirror (M16) to the top POP periscope mirror in ISCT1 was: 34 1/4 + 30 1/4  = 64.5"

Distance from REFL air steering mirror (M7) to the top REFL periscope mirror in ISCT1 was: 13 3/4 + 30 + 31.5 = 75.25"

Measurement was done using long-ish ruler, but it wasn't long enough so we had to measure the distance in multiple segments. I'd say that the error bar of this is roughly +-3/4".

jennifer.wright@LIGO.ORG - 13:41, Wednesday 14 May 2025 (84394)EPO
H1 SUS (SEI, SUS)
edgard.bonilla@LIGO.ORG - posted 16:26, Tuesday 06 May 2025 - last comment - 15:58, Monday 12 May 2025(84296)
HAM5 drive template for SR3 OSEM calibration

Follow up to 83605.

I created a few templates to do a SR3 OSEM calibration. I called them

sus/trunk/HLTS/H1/SR3/Common/Data/
yyyy-mm-dd_hhmm_H1ISIHAM5_ST1_WhiteNoise_ISO_{X,Y,Z}_0p05to40Hz_calibration.xml

The measurement should be run with all gains on SR3_M1_DAMP_{L,T,V,R,P,Y} set to - 0.1 . Just to make sure the loop gain does not mess with the OSEM measurement of the cage above resonance.

The idea is that we ought to be able to only use the cartesian measurements of the ISI to calibrate all the OSEMs in the suspensions attached by using linear algebra. This is the first pilot for that idea. We want about 100 points between 5-10Hz to make sure we can make a "decent" fit.

___

When Oli runs these templates, the plan is to use them to calibrate the SR3 OSEMs for the estimator work (see 84171 for the latest news as of the making of this post).
We will use Oli's feedback to work out the kinks of the calibration procedure and to export it to other ISIs at a later time.

 

Comments related to this report
oli.patane@LIGO.ORG - 17:41, Tuesday 06 May 2025 (84298)

I've run these three transfer function measurements with settings as follows:

  • HAM5 in ISOLATED, although with HEPI locked but the HEPI ISO gain set to 0 to bypass the locked HEPI
  • SR3 in ALIGNED
  • SR3 DAMP gains all set to -0.1

The measurements can be found in /ligo/svncommon/SusSVN/sus/trunk/HLTS/H1/SR3/Common/Data/as 2025-05-07_0000_H1ISIHAM5_ST1_WhiteNoise_ISO_{X,Y,Z}_0p05to40Hz_calibration.xml. They have been committed to the svn as r12295.

Checking the coherence between each excitation channel (H1:ISI-HAM5_ISO_{X,Y,Z}_EXCMON) and SR3's euler basis DOFs, the coherence between 5 and 10 Hz was good between the following channels:

ISO_X -> DAMP_T

ISO_Y -> DAMP_L

ISO_Z -> DAMP_V, but also pretty good coherence with DAMP_L and DAMP_T
 

edgard.bonilla@LIGO.ORG - 15:45, Monday 12 May 2025 (84365)SEI, SUS

I have run the calibration script to get the calibration factors for the SR3 OSEMs. The (multiplicative) factors are:

    LF: 1.3206
    RT: 1.3705
    SD: 1.3806
    T1: 2.4539
    T2: 1.4819
    T3: 1.4125

The factors are calculated by fitting a frequency-independent real factor to the measured uncalibrated transfer functions to fit the modeled one. The fit range is from 5 to 15 Hz. The attached plots show the before and after of the process.

 

A few observations:

1) As we had seen before, the Left and Right (LF and RT) OSEMs are pretty well matched to one another, which bodes well for our PR3 Yaw OSEM estimator plans.
2) The T1|T2|T3 OSEMs that measure the vertical direction have their orientation flipped respect to the model. I don't think there's a problem, but it is worth pointing out.
3) The T1 OSEM, which is used to distinguish roll is 70% off from T1 and T2. The large factor feels concerning, but it is consistent with other measurements of SR3. See for example 83963, where in the attached .pdf the Vertical to roll coupling is very clean (page 12). And the difference of T1, T2, and T3 can be seen very directly in page 24.

- I think it might be worth revisiting some of these transfer functions after recalibrating just to confirm that we're getting the numbers right.

Images attached to this comment
edgard.bonilla@LIGO.ORG - 15:58, Monday 12 May 2025 (84367)

If we wanted the OSEM measurements to match with the GS13 calibrations between 5-15 Hz, the factors that should be in the OSEM input filters should be:

    T1: 3.627
    T2: 1.396
    T3: 1.345
    LF: 1.719
    RT: 1.490
    SD: 1.781

Since this change will increase the effective gain of the damping loops by a factor of 30% at a minimum, we must compensate by changing the gains for the filter modules in the M1 DAMP filter bank.

Displaying reports 7141-7160 of 89074.Go to page Start 354 355 356 357 358 359 360 361 362 End