Reports until 08:18, Friday 18 April 2025
H1 ISC (PSL, SQZ)
jeffrey.kissel@LIGO.ORG - posted 08:18, Friday 18 April 2025 - last comment - 08:18, Friday 18 April 2025(83978)
SPI Pick-off Path Install Day Three; Midday Report -- Power to ALS/SQZ Fiber Distribution Path Restored
J. Kissel scribe for S. Koehlenbeck, J. Freed, R. Short, and guest star J. Oberling
ECR E2400083
IIET 30642
WP 12453

Toward the end of day two of install (LHO:83961), the team set the power at the input of the ALS-FC2 by rotating ALS-HWP2, to be 50.5 [mW] (with PMC TRANS at 103.5 [W]). The reported power for the on-table ThorLabs SM1PD1A, however, measured consistently lower at "31 [mW]," lower than the goal for this PD, a reported power of "45 [mw]" (LHO:83927), when the power of the beam between ALS-M9 and ALS-FC2 was physically measured at 48.7 [mW] (with PMC TRANS at 103.0). 

We think lower reported power on the PD is related to 
(1) The slight translation of the what-used-to-be ALS-L5 to ALS-M9 beam, because of the thickness of the SPI-BS1 that was inserted into that path, and 
(2) a change in the amount of s- and p- polarization in reflection of the ALS-PBS01 after rotating ALS-HWP2 to increase the power in the ALS/SQZ/SPI path, because the polarization state of the reflection of a PBS can be power dependent.

To support (2), we measured the polarization today between ALS-M9 and ALS-FC2 with a temporary PBS and power meter. On 2025-04-17 at 19:02 UTC with PMC power at 103.7 [W], we measure
    s-pol = 49.7 [mW]
    p-pol = 1.8 [mW]
    (total = 49.7 + 1.8 = 51.5 [mW])
Regrettably, we did not measure this polarization state prior to changing anything.

However, because we've *measured* equal total power at ALS-FC2 before vs. after, we're confident that at least the total power going into ALS-FC2 is the same. 

As such, we called in Jason to help couple the beam into ALS-FC2 using ALS-M9 and what alignment screws are on ALS-FC2 itself. Attached is the trend of that process, where we used the SPI distribution chassis PD in two forms: 
    H1:ALS-C_FIBR_INTERNAL_DC_POWER         never calibrated version, used to be 0.1 [cts]
    H1:ALS-C_FIBR_INTERNAL_DC_POWERMON      version we'd been using, calibrated into [mW]

In the end, we landed with the values of these channels at 

    H1:ALS-C_FIBR_INTERNAL_DC_POWER         0.1 [cts]
    H1:ALS-C_FIBR_INTERNAL_DC_POWERMON      31.4 [mW]
which matches our goals from LHO:83927.

The team also adjusted the position of the SM1PD1A in transmission of ALS-M9 to account for (1). However, even after moving the PD out of maximum and back, they were not able to find any position where the PD readout exceeded
    H1:ALS-C_FIBR_EXTERNAL_DC_POWERMON      31.0 [mW]
This why we expect that something more like (2) is going on. Though we looked through 
    - E1300483 (doesn't list ALS-M9), 
    - E1900246 (calls the optic ALS-M6, which is not for 1064 nm in E1300483), 
    - E0900325 (isn't new enough to have this mirror), 
    - Peter King's purchase orders circa 2019 (Req 122638553 for the fiber collimator parts, and Req 122583017 for the SM1PD1A parts)
we couldn't find anything that was clearly and obviously the ALS-M9 optic, so we can't validate or reconstruction the reflectivity in each polarization to model the factor of 31 [mW] / 45 [mW] = 0.7x (or 30% drop) reported value change.
In any event, this EXTERNAL PD channel will need to be recalibrated to better reflect the real power in this path.

Also, when we re-start up anything that uses the output of the ALS / SQZ fiber distribution, it may need to be adjusted to account for the polarization change described in (2)
Images attached to this report
Comments related to this report
jeffrey.kissel@LIGO.ORG - 14:52, Thursday 17 April 2025 (83980)
aLOGs where the existing calibration for these PDs came from (both are comments to the same Oct 2019 LHO:52381):
INTERNAL -- LHO:52398
EXTERNAL -- LHO:52403
H1 General
anthony.sanchez@LIGO.ORG - posted 08:01, Friday 18 April 2025 - last comment - 08:09, Friday 18 April 2025(83991)
Friday OPS day shift

TITLE: 04/18 Day Shift: 1430-2330 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Planned Engineering
OUTGOING OPERATOR: None
CURRENT ENVIRONMENT:
    SEI_ENV state: MAINTENANCE
    Wind: 5mph Gusts, 2mph 3min avg
    Primary useism: 0.02 μm/s
    Secondary useism: 0.17 μm/s
QUICK SUMMARY:

The Vacuum team had pumped down to about 2 .7 torr.
There is some effort to clean up staging areas and put some things back into storage.
Sounds like it will be a quiet day around here.


 

Comments related to this report
anthony.sanchez@LIGO.ORG - 08:09, Friday 18 April 2025 (83992)

Roughing pumps are being turned back on to get us down to 1 torr so we can get the Turbo pumps running!

LHO VE
janos.csizmazia@LIGO.ORG - posted 19:32, Thursday 17 April 2025 (83990)
2025 April vent - VAC diary
4-17 (Thursday) activities:

- The corner pumpdown continued, we are at ~3 Torr now, today the pumping was on for 12 hours. The pumping speed is still at (~1900 l/min). Tomorrow 5-6 more hours are needed before switching on the turbos
- A wide-range gauge (compatible with the supersucker cart) on a tee and along with a pumpdown port was installed on the freshly installed HAM6 turbo
- The HAM6 turbo was then started up - as it was its initial test -, and keeps running, ready to be valved in tomorrow
- The BSC8 annulus Ion pump is still suffering (~8E-6 Torr), but the pressure is slowly coming down
- The HAM4 annulus system has been taken care of, after switching off the Ion pump last week, now the volume is being pumped with an aux cart
- The GV5 annulus system is still being pumped by an aux cart, with the Ion pump switched off
- The leak checking was continued, all the CF flanges on the Y-manifold were leak checked: Y+ side (6 pcs.); Turbo flange (1 pc.); vent valve (1 pc.); Varian valve (1 pc., see more info at aLog 83951 - after all, it seems that it is only an internal leak). All flanges were found leak-tight.
H1 TCS
matthewrichard.todd@LIGO.ORG - posted 17:22, Thursday 17 April 2025 (83979)
Using HOM spacing to estimate surface defocus from self heating

M. Todd, C. Compton, S. Dwyer


Over the past few weeks I've been trying to understand what we can learn from some of the ETMY ring heater power changes that we've made over the past 9 months or so. By looking at the Higher Order Mode spacing from OMC data as well as substrate lensing from the HWS data, we hope to be able to make some models or estimates of the coupling factors of the different actuators to substrate and surface defocus.

In particular, we want to use the HOM spacing to estimate how much of the surface defocus comes from self heating.


This derivation is better illustrated in the attachment below, which has a neater write up of the following logic:

1) Known values : HOM spacing, FSR, Cold-State Surface Curvature, Ring Heater Power, Coupling Factor of Ring Heater Power to Surface Defocus, g-factor of the ITM and ETM

2) Desired values: Surface Defocus from Self-heating (coupling * absorbed power)

Through solving some of the equations relating these values, with the assumption that our coupling factors are correct, we estimate the self-heating to change the surface curvature by about 13%.

Images attached to this report
Non-image files attached to this report
H1 General
anthony.sanchez@LIGO.ORG - posted 16:48, Thursday 17 April 2025 (83987)
Thursday OPs Report.

TITLE: 04/17 Day Shift: 1430-2330 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Planned Engineering
INCOMING OPERATOR: None
SHIFT SUMMARY:
The Vacuum team has been hard as work removing the air from the corner station. We seem to be below 20 torr.
The SPI team has Finished putting in their pickoff inside the PSL.
The SEI team workin on HAM1 still has more work to do.
SUS team has been cleaning optics in the Mega chamber as well

Also:
19:30 Hanford site called the LHO control room to let us know that they were performing a Take Cover Drill. The Operator Core decided to go over the protocol for shutting off the HVAC system in the case that this was not a drill.

LOG:

Start Time System Name Location Lazer_Haz Task Time End
14:45 FAC Nellie &  Kim LVEA NO Technical Cleaning 16:45
15:27 VAC Jordan LVEA N Resuming pumpdown 16:03
15:35 FAC Tyler LVEA N Putting compass stickers on cranes 16:47
15:44 Plant Study H Miss. cont Mid X N Studying plants? 17:11
15:47 PCAL Tony PCAL Yes Transfer standard PCAL measurement 15:57
15:58 SEI Jim LVEA Racks n checking ADC cabling 19:28
16:01 FAC Randy & Mitchel LVEA N Moving equipment & machines Started ~16:09 18:35
16:10 CDS Dave B Remote N Model & DAQ restart 16:19
16:12 SPI Sina & Ryan S LVEA Yes Installing SPI Pickoff 19:16
16:13 EE Daniel LVEA racks N Running Cabling 21:01
16:14 EE Marc LVEA N Running Cables with Daniel 23:24
16:17 SEI Jim LVEA HAM1 N Working on in air side feed throughs on HAM1 16:20
16:19 SPI Josh Optics Lab & PSL Yes Working on Optics for SPI With Escort Jeff. 19:16
16:48 EE Fil LVEA N Cabling for HAM1 with Daniel & Marc 23:24
17:02 FAC Kim LVEA n Vacuuming in MSR 17:32
17:04 PSL Jason PSL Yes Helping out with SPI 18:56
17:22 SUS Rahul & Ryan C LVEA HAM6-7 N First contact of triple suspensions. 18:14
18:09 VAC Janos & Jordan HAM6 area N Checking Guages and Valves 20:24
18:42 Sun Ryan C Y arm n Taking a walk down Y arm. 19:15
18:46 HAM1 Camilla LVEA N Retreiving Parts. 18:53
19:38 OPS Tony, Ibrahim, Ryan C, Oli, TJ, Ryan S, Eric Mechanical Room N Hanford Radiation Emergency Drill Respons 19:39
20:25 VAC Jordan LVEA HAM4 N Setting up pump on HAM4 Annulus & Cap Inventory Checks 22:28
20:39 SPI Ryan S, Sina, Josh PSL Yes Installing SPI Pickoff 22:00
20:54 VAC Travis & Janos HAM4 Area N Vacuum pump activities 21:59
21:02 SUS Rahul, Ryan C LVEA HAM6 N cleaning Tripple SUS optics. 22:14
21:07 Saftey Richard LVEA N Safety checks 21:24
21:29 SEI Jim LVEA HAM1 N Restarting HAM 1 SEI Systems 22:28
22:00 Prop Travis End X &Y N Property inventory 22:37
22:14 SEI Jim CER N Checking SEI Config 00:14

 

Images attached to this report
H1 PSL (ISC)
ryan.short@LIGO.ORG - posted 16:45, Thursday 17 April 2025 - last comment - 10:57, Friday 25 April 2025(83989)
SPI Pick-off Path Install Day Three: Complete!

S. Koehlenbeck, J. Freed, J. Kissel, J. Oberling, R. Short

The SPI pick-off path installation on the H1 PSL table is now complete. The beam in the new SPI path has been reduced to 20mW and is currently being dumped with a razor dump between SPI-L1 and SPI-L2. Pictures attached reflect the final installation and layout, which will be be reflected in the updated as-built layout at a later date.

Associated entries: 83925, 83933, 83956, 83961, 83978, 83983 (and more to come)

Images attached to this report
Comments related to this report
jeffrey.kissel@LIGO.ORG - 15:28, Friday 18 April 2025 (83998)ISC, SQZ
ECR E2400083
IIET 30642
WP 12453

Here's Ryan's birdseye view labeled with all the components.
For details of the components, see the SPI BOM, T2300363, exported from its google sheets to -v4 as of this entry.
Images attached to this comment
corey.gray@LIGO.ORG - 09:53, Monday 21 April 2025 (84019)EPO

Tagging EPO for photos.

joshua.freed@LIGO.ORG - 10:57, Friday 25 April 2025 (84120)

83996 Power In ALS / SQZ / SPI Paths Post SPI Pick-off Install

H1 AOS
betsy.weaver@LIGO.ORG - posted 16:11, Thursday 17 April 2025 (83985)
Vent Schedule Status
Still on schedule!

Currently in the Stand-down in HAM1 such that the corner pump down can get to a more exercised safe state.  

Attached is a snapshot of what is planned for the next few days.  

(Things un-checked on today's list are expected to continue early next week per plan.)
Images attached to this report
H1 SUS (SUS)
rahul.kumar@LIGO.ORG - posted 15:45, Thursday 17 April 2025 - last comment - 10:00, Monday 21 April 2025(83984)
Prep work for HAM1 SUS Tip Tilt (RM1, RM2 and PM1) installation

RyanC, Rahul

SUS Tip Tilt - RM1, RM2 and PM1 (picture attached) are now ready to be installed into HAM1, once the chamber is ready to accept them. The blade springs of all three suspensions have been un-muted and bosem connectors have kapton take inserted to prevent grounding issues. This morning we cleaned all three optics using First Contact - see picture for reference.

 

PM1 Beam Dump (rear)

Camilla, Betsy, RyanC, Rahul

SUS PM1 (Tip Tilt) has a new beam dump attached to it's rear - as shown in several pictures attached below. We had to design a new plate (D2500101_V1) to attach the beam dump. I can confirm that all the components integrates well with PM1 and there is some scope for adjustability as well.

Team SUS is now ready for HAM1 installation work.

Images attached to this report
Comments related to this report
corey.gray@LIGO.ORG - 10:00, Monday 21 April 2025 (84020)EPO

Tagging EPO for photos.

H1 PSL (ISC, PSL)
sina.koehlenbeck@LIGO.ORG - posted 15:36, Thursday 17 April 2025 - last comment - 11:44, Monday 21 April 2025(83983)
Install SPI pick-off path: Laser mode to fiber collimator

S. Koehlenbeck, J. Freed, R. Short, J. Kissel

The mode matching of the PSL pick-off beam to the SPI fiber collimator has been implemented using two lenses. The target beam has a mode radius of 550 µm at a position 63.5 cm downstream from the SPI beamsplitter (SPI-BS).

The lens configuration that produced the closest match to the target mode used:

Attached is a beam profile fit performed using JaMMT on data acquired with a WinCamD of the beam after SPI-L2. The measured beam radii at various distances from the SPI-BS are as follows:

Distance (cm) Horizontal Radius (µm) Vertical Radius (µm)
70.734 476 542
91.054 470 543.5
116.454 558.5 616.5

Both lenses are oriented such that their planar sides face the small beam waist between the two lenses. The arrows on the lens mounts point toward the convex surfaces.

The power transmission through the fiber has been measured to be 83 %.

Images attached to this report
Comments related to this report
jeffrey.kissel@LIGO.ORG - 10:35, Friday 18 April 2025 (83995)ISC, SEI, SQZ, SYS
ECR E2400083
IIET 30642
WP 12453


Some "for the record" additional comments here:
- Sina refers to the "SPI-BS" above, which is the same as what we've now officially dubbed as "SPI-BS1."

- Lenses were identified to be needed after the initial measurement of the beam profile emanating from SPI-BS1. That initial beam profile measurement is cited in LHO:83956, and the lens also developed in JaMMT with the lenses that were available from the optics lab / PSL inventory.

- If anyone's trying to recreate the model of the beam profile from the two measurements (LHO:83956 with no lenses, and the above LHO:83983) just note that the "zero" position is different in the quoted raw data; in LHO:83956 is the front of the rail, on Column 159 of the table, and in LHO:83983 the zero position is the SPI-BS1 reflective surface which is on Column 149 of the table, i.e. a 10 inch = 25.4 cm difference.

- The real SPI-L1 installed to create this mode-shape / beam profile is labeled by its radius of curvature, which is R = 51.5 mm, and thus its focal length is more precisely f = R*2 = 103 mm. (We did find a lens that does have f = 60 mm for SPI-L2, and it's labeled by its focal length.)

- "the fiber" is that which is intended for permanent use, depicted as SPI_PSL_001 in the SPI optical fiber routing diagram D2400110, a Narrow Key PM-980 Optical Fiber "patch cord" from Diamond, whose length is 30 [m]. This fiber will run all the way out to SUS-R2, eventually, to be connected as the input to the SPI Laser Prep Chassis (D2400156).

- Per design, light going into this fiber is entirely p-pol, due to polarization via SPI-HWP1 and clean-up by SPI-PBS01 just upstream. We did not measure the polarization state of the light exiting the fiber.

- The raw data that informs the statement that "the power transmission thru the fiber has been measured to be 83%":
     : We measured the input to the fiber coupler, SPI-FC1, via the S140C low-power power meter we'd been using throughout the install. The output power was measured via a fiber-coupled power meter Sina had brought with her from Stanford (dunno the make of that one).

     : We measured the power input to the fiber twice several hours apart (with the change in fiber input power controlled via the SPI-HWP1 / SPI-PBS01 combo).,
         (1) 19.9 [mW] with PMC TRANS power at 104.1 [W] at 2025-04-17 16:35 UTC (while the PMC power was in flux from enviromental controls turn on)
         (2) 180 [mW] with PMC TRANS power at 103.5 [W] at 2025-04-17 14:00 UTC (while the PMC power was quite stable)

     : We measured the output power
         (1') 16.6 [mW] with PMC TRANS power at 103.7 [W] at 2025-04-17 17:35 UTC (an hour later than (1))
         (2') 150 [mW] with PMC TRANS power at 103.5 [W] at 2025-04-17 14:00 UTC (simultaneous to (2))

     : Thus derive the transmission to be 
         (1'') (16.6 / 19.9) * (104.1/103.7) = 0.837 = 83.7% and 
         (2'') (150 / 180) * (103.5/103.5) = 0.833 = 83.3%
sina.koehlenbeck@LIGO.ORG - 11:44, Monday 21 April 2025 (84025)

In the attachment you will find the JAMMT model for the measured beam profile of the PSL pick off with the origin a SPI-BS1, as well as the lenses used to adjust the mode of the beam for the fiber collimator FC60-SF-4-A6.2-03.

Images attached to this comment
H1 SEI
anthony.sanchez@LIGO.ORG - posted 15:12, Thursday 17 April 2025 (83981)
Monthly Hepi trends

FAMIS 27813
HEPI trends for the last month.

The sudden drop in the HEPI trends happened on the same day at the same time as the Power outage .

The last week can be see here and looks good except for today which show multiple DAQ restarts.

Images attached to this report
H1 SUS (SEI)
brian.lantz@LIGO.ORG - posted 15:00, Thursday 17 April 2025 (83982)
OSEM estimator basic testing

Brian, Oli, Edgard

Testing the implementation of the OSEM estimator installed on SR3. The models were installed on Monday. We don't have the model transfer functions yet. We were testing the basic OSEM path and the switch. We were testing SR3 YAW. It all looks good so far - the OSEM signal is getting to where it should be, and fader-switch is working correctly.

-- detailed testing notes --

ISI is damped. vacuum is still pumping pressure is ~16 torr. Looks like the suspension is still moving because of temperature changes so we can't do useful TFs yet.
GPS time 14289 57082
Look at the drive level of the classic damper, the pk-pk with normal damping is about  -0.04 to +0.04

channels all start with H1:SUS-SR3_

Look at channels: M1_YAW_DAMP_EST_OUTPUT,  M1_YAM_DAMP_OSEM_OUTPUT,  M1_YAW_DAMP_SIGMON, M1_DAMP_Y_OUTPUT,  M1_DAMP_Y_IN1

Y osem damper gain is -0.5 instead of -1.0.  Gabriele changed this.

Test 1 - are the OSEM signals getting to the OSEM path, and is the damper control set correctly? - YES!

Set the YAW_DAMP_OSEM filter bank to be the same at the DAMP_Y bank
The output switch for the estimator is OFF - so the OUTPUT signal from the YAW_DAMP_OSEM filter does not get to the osem drives

Output signals of the 2 damping controllers should be the same - and they do look the same. Put them on top of each other and they seem identical

Test 2 - use the classic damping and the YAW_OSEM path, does it work? - Yes!

1. set the YAM_DAMP_OSEM gain to -0.4 (from -0.5)
2. set the classic damping gain to -0.1 (from -0.5)  (so 20% of the gain is in the classic path, 80% in the estimator path)

gps time ~...58716, Turn on the estimator. This should recover the previous normal damping.
Switch looks smooth - no glitching, no drama. comes on well
The drive levels look like 4 to 1 by eye (correct). total drive looks about the same as before.

Turn off estim path at ...58900 ish. OSEM input signal doesn't look any different (gah, really?!, of course not, it's all sensor noise)

Test 2 successful - switch seems smooth, damping paths look good

Test 3 - test the switch between OSEM path and Estimator path - is it smooth and well behaved? - YES!

Set Estim damping control to be the same as the OSEM damping control.

Set the OSEM Bandpass to 1 so OSEM_DAMPER and ESTIM_DAMPER inputs should match (they do) and the outputs should match (they do).

these three signals should all be the same now during the switch from OSEM to Estim
M1_YAW_DAMP_SIGMON (this is the switch output)
M1_YAW_DAMP_OSEM_OUTPUT  (first input)
M1_YAW_DAMP_EST_OUTPUT  (second input)
start around 59720 -

then switch back and forth several times - these signals all stay on top of each other and are indistinguishable.

GPS is about ...60100
Zoom in for a close look at the start and stop of the fade to look for glitching - I don't see any, see plot in comment.
Test3 - success - by eye we can no see any difference in the 3 channels.

H1 SQZ
sheila.dwyer@LIGO.ORG - posted 13:44, Thursday 17 April 2025 (83953)
revisting arm power bounds from squeezing: 310kW- 353kW

In 82097 we got some constraint on the circulating power in the arm from the squeezer data set.  I'm working on looking at the data that Camilla took in 83660, and realize that with the higher nonlinear gain the frequency independent squeezing gives us a better constraint on the arm power.

Using known injection losses of 8.2%(google sheet),   and  6% extra HAM7 losses from 83070 gives 13.7% minimum injection losses for squeezing, and our known readout losses are 8.4%.  Based on 16.1dB of anti squeezing (for NLG of 19 as reported by Camilla) and -4.97 dB squeezing, the infered NLG is 18.7 and the total sqz efficiency is 0.694 (with 0 phase noise). This means that in addition to the 6% extra losses measured on the homodyne, we have another 12% unknown squeezer losses.  We can assign those 12.2% losses to either injection losses (unlikely since there isn't much between homodyne pick off point and injection into the OFI), readout losses that also impact the IFO readout, or squeezer readout losses that don't impact the IFO (SQZ to OMC mode matching). 

If the only IFO readout losses are the known losses, the IFO readout efficiency is 91.6%, and we can use the shot noise level without squeezing injected to estimate that the minimum arm power is 310kW.  Using the total squeezer efficiency and the known losses, we can place bounds on the readout efficiency between 80.4% and 91.6%.  The level of shot noise measured without squeezing mostly depends on arm power and readout efficiency, so this maximum readout efficiency gives us a minimum arm power of 310kW (all squeezer losses are injection losses, readout efficiency is 91.6% and arm power is minimum), while the minimum readout efficiency gives us 353kW (all unknown squeezer losses are common to IFO, which probably wouldn't be the case for mode mismatches). 

Images attached to this report
X1 SUS (SUS)
rahul.kumar@LIGO.ORG - posted 12:55, Thursday 17 April 2025 (83977)
A+ O5 HRTS (suspended configuration L1BHDM1) being transported from LHO to LLO

Ryan C, Rahul

L1BHDM1 which is the suspended configuration of HRTS (HAM Relay Triple Suspension) for O5 is now ready to be shipped to LLO (using ground freight). The suspension (all stages locked with EQ stops, torqued double nuts and tension removed from wires ) has been wrapped in several layers of clean foil/clean cloth and clean bag as shown here.

This shipment is expected to reach LLO sometime at the end of next week (25th April), if it leaves LHO today. The details of the shipment are given below,

Tracking Site Link: https://www.shipdbi.com/ HWB Number for TRK: 139289

FRS ticket - https://services1.ligo-la.caltech.edu/FRS/show_bug.cgi?id=33849

ICS (assembly record) - https://ics.ligo-la.caltech.edu/JIRA/browse/ASSY-D1900449-L1BHDM1

ICS (shipment load) - https://ics.ligo-la.caltech.edu/JIRA/browse/Shipment-13842

This is first of the total six HRTS which will be transported to LLO.

Images attached to this report
H1 CDS
david.barker@LIGO.ORG - posted 11:11, Thursday 17 April 2025 - last comment - 16:13, Thursday 17 April 2025(83973)
h1isiham1 model restarts, DAQ restarts

Jim, Tony, Dave:

We restarted h1isiham1 model four times and the DAQ twice:

1. Internal wiring change to model, no DAQ retstart for that but new common part with "missing ADC chans" fix was included which did require a DAQ restart. No issues with DAQ restart other than gds0 needed a second restart.

2. A copy-paste binary parts issue was found, HAM6 parts were included in HAM1. BIO parts were renamed, no DAQ restart was neeed.

3. HAM1 differs from HAM6 in BIO inputs in that it reads 64 input channels instead of just 32. Upper32 channel BIO part was added, which added slow channels, so DAQ restart was required. No issues with DAQ restart other than gds0 second restart.

4. To minimize binary chassis hardware, HAM1 and HAM6 share the first BIO card's binary output chassis, HAM6 uses lower 32 chans, HAM1 uses upper 32 chans. h1isimodel was changed to use BIO-0 U32 for outputs. No DAQ restart was required.

Current BIO hardware as see by models:

wiring input block model   model output block wiring
from ham6 BIO-0 low 32 h1isiham6   h1isiham6 BIO-0 low 32 to ham6
not connected BIO-0 high 32 none   h1isiham1 BIO-0 high 32 to ham1
             
from ham1 BIO-1 low 32 h1isiham1   none BIO-1 low 32 no chassis
from ham1 BIO-1 high 32 h1isiham1   none BIO-1 high 32 no chassis

 

Comments related to this report
david.barker@LIGO.ORG - 11:27, Thursday 17 April 2025 (83974)

DAQ Changes

1st DAQ restart (correct missing ADC chans)

++: slow channel H1:ISI-HAM1_PMON_GS13_P3_CTS added to the DAQ
++: slow channel H1:ISI-HAM1_PMON_GS13_P2_CTS added to the DAQ
++: slow channel H1:ISI-HAM1_PMON_GS13_P1_CTS added to the DAQ
++: slow channel H1:ISI-HAM1_PMON_GS13_D3_CTS added to the DAQ
++: slow channel H1:ISI-HAM1_PMON_GS13_D2_CTS added to the DAQ
++: slow channel H1:ISI-HAM1_PMON_GS13_D1_CTS added to the DAQ
++: slow channel H1:ISI-HAM1_PMON_FF_L4C_P3_CTS added to the DAQ
++: slow channel H1:ISI-HAM1_PMON_FF_L4C_P2_CTS added to the DAQ
++: slow channel H1:ISI-HAM1_PMON_FF_L4C_P1_CTS added to the DAQ
++: slow channel H1:ISI-HAM1_PMON_FF_L4C_D3_CTS added to the DAQ
++: slow channel H1:ISI-HAM1_PMON_FF_L4C_D2_CTS added to the DAQ
++: slow channel H1:ISI-HAM1_PMON_FF_L4C_D1_CTS added to the DAQ
 

2nd DAQ restart (read H32 BIO-1 channels)

++: slow channel H1:ISI-HAM1_BIO_IN_GAIN_L4C_H1_RB added to the DAQ
++: slow channel H1:ISI-HAM1_BIO_IN_GAIN_L4C_H2_RB added to the DAQ
++: slow channel H1:ISI-HAM1_BIO_IN_GAIN_L4C_H3_RB added to the DAQ
++: slow channel H1:ISI-HAM1_BIO_IN_GAIN_L4C_V1_RB added to the DAQ
++: slow channel H1:ISI-HAM1_BIO_IN_GAIN_L4C_V2_RB added to the DAQ
++: slow channel H1:ISI-HAM1_BIO_IN_GAIN_L4C_V3_RB added to the DAQ
++: slow channel H1:ISI-HAM1_BIO_IN_INMON2 added to the DAQ
++: slow channel H1:ISI-HAM1_BIO_IN_TEST2 added to the DAQ
++: slow channel H1:ISI-HAM1_BIO_IN_TESTMON2 added to the DAQ
++: slow channel H1:ISI-HAM1_BIO_IN_WHT_L4C_H1_RB added to the DAQ
++: slow channel H1:ISI-HAM1_BIO_IN_WHT_L4C_H2_RB added to the DAQ
++: slow channel H1:ISI-HAM1_BIO_IN_WHT_L4C_H3_RB added to the DAQ
++: slow channel H1:ISI-HAM1_BIO_IN_WHT_L4C_V1_RB added to the DAQ
++: slow channel H1:ISI-HAM1_BIO_IN_WHT_L4C_V2_RB added to the DAQ
++: slow channel H1:ISI-HAM1_BIO_IN_WHT_L4C_V3_RB added to the DAQ
 

david.barker@LIGO.ORG - 11:31, Thursday 17 April 2025 (83975)

Thu17Apr2025
LOC TIME HOSTNAME     MODEL/REBOOT
09:09:41 h1seih16     h1isiham1   <<< model restart, fix wiring, add missing-adc-chans
09:12:10 h1daqdc0     [DAQ] <<< 0-leg
09:12:20 h1daqfw0     [DAQ]
09:12:21 h1daqtw0     [DAQ]
09:12:22 h1daqnds0    [DAQ]
09:12:29 h1daqgds0    [DAQ]
09:13:19 h1daqgds0    [DAQ] <<< 2nd gds0 restart
09:16:23 h1daqdc1     [DAQ]
09:16:33 h1daqfw1     [DAQ] <<< 1-lde
09:16:34 h1daqtw1     [DAQ]
09:16:35 h1daqnds1    [DAQ]
09:16:44 h1daqgds1    [DAQ]
10:10:21 h1seih16     h1isiham1   <<< model restart, change bio address
10:27:28 h1seih16     h1isiham1   <<< model restart, add BIO-1 H32
10:32:12 h1daqdc0     [DAQ] <<< 0-leg
10:32:23 h1daqfw0     [DAQ]
10:32:24 h1daqtw0     [DAQ]
10:32:26 h1daqnds0    [DAQ]
10:32:32 h1daqgds0    [DAQ]
10:35:28 h1daqgds0    [DAQ] <<< 2nd gds0 restart
10:36:21 h1daqdc1     [DAQ] <<< 1-leg
10:36:32 h1daqfw1     [DAQ]
10:36:32 h1daqtw1     [DAQ]
10:36:34 h1daqnds1    [DAQ]
10:36:42 h1daqgds1    [DAQ]
10:57:48 h1seih16     h1isiham1   <<< model restart, drive BIO-0 H32
 

david.barker@LIGO.ORG - 16:13, Thursday 17 April 2025 (83986)

Two more h1isiham1 model restarts, the first with an associated DAQ restart.

14:35 h1isiham1 binary output block was upgraded, adding slow channels to the DAQ. During DAQ restart gds0 and gds1 needed second restarts.

15:53 h1isiham1 input bus selector to binary output block was corrected, no DAQ restart needed.

14:35:41 h1seih16     h1isiham1   <<< new binary output block
14:37:30 h1daqdc0     [DAQ] << 0leg
14:37:40 h1daqfw0     [DAQ]
14:37:40 h1daqtw0     [DAQ]
14:37:41 h1daqnds0    [DAQ]
14:37:48 h1daqgds0    [DAQ]
14:38:22 h1daqgds0    [DAQ] <<< 2nd gds0 restart
14:41:43 h1daqdc1     [DAQ] <<< 1leg
14:41:54 h1daqfw1     [DAQ]
14:41:54 h1daqtw1     [DAQ]
14:41:55 h1daqnds1    [DAQ]
14:42:03 h1daqgds1    [DAQ]
14:43:00 h1daqgds1    [DAQ] <<< 2nd gds1 restart
15:53:57 h1seih16     h1isiham1   <<< correct input bus of binary output block
 

H1 PSL
jeffrey.kissel@LIGO.ORG - posted 16:03, Wednesday 16 April 2025 - last comment - 11:35, Monday 21 April 2025(83961)
SPi Pickoff Path Install Day Two
J. Kissel scribing for S. Koehlenbeck, J. Oberling, R. Short, J. Freed
ECR E2400083
IIET 30642
WP 12453

Another quick summary aLOG at the end of the day, with more details to come:
- With the power in the ALS/SQZ pick-off path to 10 [mW] for beam profiling,
- Installed a two lens system to handle the unexpectedly different beam profile of the ALS/SQZ pick-off path
- Remeasured the resulting mode after the two lens system, and we're happy enough. We're gunna call them SPI-L1 and SPI-L2.
- Installed steering mirrors SPI-M1 and SPI-M2.
- Rotated ALS-HWP2 to increase the s-pol light in the ALS/SQZ/SPI path to return the power transmitted through SPI-BS1 going to the ALS/SQZ fiber collimator back to 50.5 [mW]. This set the SPI path to 186 [mW] with the PMC TRANS measured at 103.5 [W]. The ALS_EXTERNAL PD in transmission of ALS-M9 measured 31 [mW] ***. 
- Installed SPI-HWP1 and SPI-PBS01
- Measured the power at each port of SPI-PBS01, with the intent to optimize the SPI-HWP1 position to yield maximum p-pol transmission through SPI-PBS01.

*** We expect this is lower than the goal of ~45 [mW] (from LHO:83927) because we've not yet re-aligned the ALS/SQZ fiber collimator path after the install of the SPI-BS1, which translates the beam a bit due to the thickness of the beam splitter. We intend to get back to this once we're happy with the SPI path.
Comments related to this report
ryan.short@LIGO.ORG - 17:54, Wednesday 16 April 2025 (83965)

Small correction to above is after installing SPI-HWP1 and SPI-PBS01, we adjusted HWP1 to have 20mW in transmission of PBS1 (not maximum quite yet) to start alignment into the fiber. Using the two steering mirrors downstream of PBS1 and the collimating lens in front of the fiber, Sina maximized the transmission as measured with the output of the fiber on a spare PD. We then took power measurements of the input and output of the fiber:

  • Input: 19.4mW
  • Output: 13.5mW
  • Transmission ratio: 72.1%

This is a good start, but with a target ratio of >80%, there's still more work to be done here improving the beam into the fiber collimator. Out current mode-matching solution claims we should have 95% mode overlap into the fiber, so hopefully the issue is alignment, but it's entirely possible we'll revisit the mode-matching to see if improvements can be made there too.

The attached photo represents the optical layout as it stands as of where we stopped today, with the new SPI fiber in blue on the left (north) side of the table.

Images attached to this comment
jeffrey.kissel@LIGO.ORG - 12:10, Thursday 17 April 2025 (83976)ISC, SQZ, SYS
Re-post of Ryan's picture at the end of day 2, labeled with the almost entirely complete SPI pick-off path.

Critically here, this shows the PSL row/column grid, confirming that this whole ECR E1900246 ALS pick-off path is 2 rows "higher" in +Y than is indicated on the current version of the as built PSL drawing D1300348-v8.
Images attached to this comment
jeffrey.kissel@LIGO.ORG - 11:35, Monday 21 April 2025 (84024)
Ryan grabbed another picture I attach here. This shows the ALS pick-off path on this day in order to support the identification that the beamline between ALS-M1, through the faraday ALS-FI1 and ALS-L1, etc stopping at ALS-M2 (not pictured) is on row 25 of the PSL table *not* row 23 as drawn in D1300348-v8. I attach both the raw picture and my labeled version. So, ya, ALS-M1 should have its HR surface centered on Row 25, Col 117.

Note, the grid in the picture is labeling bolt holes. Because the optical elements are all ~4 inches above the table, the beams appear offset from the way they travel on along the grid given that the photo was taken at a bit of an angle from vertical. May the future updater of D1300348 bear this in mind.

Images attached to this comment
H1 SUS
oli.patane@LIGO.ORG - posted 15:47, Monday 14 April 2025 - last comment - 16:24, Thursday 17 April 2025(83913)
SUS HLTS 10:0.4 filter updated

Edgard, Oli

In 83662 it was discussed that the osem compensating filter z:p = 10:0.4 wasn't as accurate as it should be. Jeff worked out that the zero and pole from the satamp are 0.3835 Hz and 10.6103 Hz, respectively, so our compensating filter should be the opposite of that, with a zero at 10.6 Hz and a pole at 0.38 Hz.

Today we updated those filters for PR3 and SR3. They appear in all three stages in the initial OSEMINF filter bank (FM1) (H1:SUS-PR3_M{1,2,3}_OSEMINF_{sensor})  as well as in all three stages of the watchdog bandpass filter bank (FM6) (H1:SUS-PR3_M{1,2,3}_WD_OSEMAC_BANDLIM_{sensor}). So where before those filters there were 10:0.4, they now read 10.6:0.38 and have these updated zero and pole values. We've loaded in the coefficient changes.

I've attached the script that we used to update these filters below. It's an edit of Jeff's script in 80189

Non-image files attached to this report
Comments related to this report
edgard.bonilla@LIGO.ORG - 16:24, Thursday 17 April 2025 (83988)

Edgard, Oli, Brian

Checking on the sat amp compensation filter change from 10:0.4 to 10.6:0.38, we noticed that it has the net effect of decreasing the OSEM signal with respect to before the change [see first attachement].

The compensation would make the OSEM corrections from 83605 about 5-6% larger, which we can estimate by looking at the ratio between the new compensation filter and the old compensation filter. [see second attachment].

Images attached to this comment