james.batch@LIGO.ORG - posted 12:49, Friday 07 March 2014 (10608)
Awgstream updated
The awgstream software for the control room has been updated to increase the size of the channel list it reads.  This should solve the problem encountered Wednesday in which H1:SUS channels could not be excited using awgstream.
H1 SUS
arnaud.pele@LIGO.ORG - posted 12:32, Friday 07 March 2014 - last comment - 01:29, Monday 10 March 2014(10607)
ETMX and ITMX PUM measurements

Yesterday night and this morning some diagonalization measurements were taken with pum drive on etmx and itmx. The low coherence for the pitch drive described on the previous alog was due to the optic not centered enough on the oplev, so both ETMX p2p and y2y were remeasured. Those measurements can actually be really fast (15/20min each).
ITMX measurement has some calibration factor of 1.56 for Yaw and 1.83 in Pitch. T1100378 was the reference for calibrating the drive from cts to N.

Attached are the plots comparing the measurement and the model (wirerehang for itmx, fiber for etmx). Note that there is a sign error in ETMX Yaw, so we should double check if that comes from the Oplev sign convention.
 

ITMX : /ligo/svncommon/SusSVN/sus/trunk/QUAD/H1/ITMX/SAGL2/Results/quad_{p2p/y2y}.mat

ETMX : /ligo/svncommon/SusSVN/sus/trunk/QUAD/H1/ETMX/SAGL2/Results/quad_{p2p/y2y.mat

ITMX : /ligo/svncommon/SusSVN/sus/trunk/QUAD/H1/ITMX/SAGL2/Data/2014-03-06_H1SUSITMX_{P2PY/Y2PY}_WhiteNoise.xml

ETMX : /ligo/svncommon/SusSVN/sus/trunk/QUAD/H1/ITMX/SAGL2/Data/2014-03-04_H1SUSETMX_{P2PY/Y2PY}_WhiteNoise.xml

ITMX : /ligo/svncommon/SusSVN/sus/trunk/QUAD/H1/ITMX/SAGL2/Scripts/itmx_L2_diag.m

ETMX : /ligo/svncommon/SusSVN/sus/trunk/QUAD/H1/ETMX/SAGL2/Scripts/etmx_L2_diag.m

Images attached to this report
Comments related to this report
keita.kawabe@LIGO.ORG - 15:26, Friday 07 March 2014 (10610)

PUM drivealign P2P and Y2Y filters were installed.

In each of the attached, foton screen shot to the left shows the actual filter installed, matlab plot to the right shows the P2P or Y2Y measurement, fit, model, and the expected TF from PUM to the test mass after the new filter takes effect.

As you see I made the filters such that ITM and ETM looks as if they share the same low Q (Q=3) resonance at 0.51 Hz for PIT and 0.6Hz for YAW. There's also a roll of at 30Hz, which is not that aggressive. If necessary you can easily add more.

I ignored the DC calibration of the measurement. I'll handle them in the gain.

The filters relevant are FM1 of H1:SUS-ETMX_L2_DRIVEALIGN_P2P, Y2Y and corresponding ITMX filters.

Scripts used for the fit and inversion as well as the filter definition files generated by the scripts are:

~controls/keita.kawabe/fit/[EI]XPUM_[PY]2[PY]fit.m

~controls/keita.kawabe/fit/[EI]XPUM_[PY]2[PY]inversion_soscoeffs.txt

Images attached to this comment
arnaud.pele@LIGO.ORG - 01:29, Monday 10 March 2014 (10643)

[Yuta Keita Arnaud]

ETMX ITMY ITMX top mass P2P drivealign filters installed

On friday, filters were designed the same way as Keita, in order to get a single pendulum transfer function from the top mass drive to the test mass displacement in pitch. The filters were installed in the top drivealign matrix in FM1 of the P2P bank filter. ITMX filter is a copy paste from ITMY, assuming they have the same P2P transfer function (both are wires). Attached are the plots showing the design of the filters and the foton version. The transfer function after filtering has its cut off frequency at 0.45Hz for ETMX and 0.55Hz for ITMY/ITMX.

ETMX Length to pitch decoupling was also designed and installed in L2P drivealign matrix. Plots of design pending.

Images attached to this comment
H1 SEI (AOS, INS, SUS)
hugh.radkins@LIGO.ORG - posted 10:50, Friday 07 March 2014 (10606)
WBSC10 ETMY SEI Activities and Status

The HEPI and ISI are locked at EndY.  SUS is being stopped down and ACB staging/prep is ongoing for installation.

LHO VE
kyle.ryan@LIGO.ORG - posted 10:41, Friday 07 March 2014 (10605)
~1000-1030 hrs. local -> Started pumps on elevated BT slab near GV6 in LVEA
These will be running continuously for the next week or two (part of portable RGA assembly/Y1 accumulation data collection).
H1 ISC
corey.gray@LIGO.ORG - posted 09:41, Friday 07 March 2014 - last comment - 15:46, Friday 07 March 2014(10604)
EY TMS Cable Inventory Map

With Jim needing to connect In-Vac cables to feedthrus today, I wanted to update the EY TMS Cable Table (mainly to show recent change of swapping damaged D1000223 cable with D1000225).  All of this follows the BSC10 Cable Routing Configuration (D12000111) & is in the following ICS Assy Load.

In-Air Cable
 
Chamber
feed-thru
Seismically-Responsible Cables Cable Bracket In-Vac Cable Cable Bracket
on TMS
In-Vac Component
: Not sure of name : E6-7C1 D1000225 s/n S1104782
*no feedthru screws?
CB-5 , 1st Floor D1000234 s/n96-911 no CB OSEMS:  Face1, Face2, Face3, Left
: Not sure of name : E6-7C2 D1000225 s/n S1104778
*no feedthru screws?
CB-5 , 2nd Floor D1000234 s/n96-901 no CB OSEMS:  Right, Side, ---, ---
: Not sure of name : F2-2C1 D1000924 s/n S1104106
*no feedthru screws?
CB2 , 1st Floor (was 3rd Floor of BSC6 CB) D1000568 s/nS1104468 CB-primary, 1st floor Green QPD (D1000231 s/n C2Q001 aka S1400085)
: Not sure of name : F2-1C2 D1000924 s/n S1104469 CB2 , 2nd Floor (was 2nd Floor of BSC6 CB) D1000568 s/nS1104109 CB-primary, 2nd floor Red QPD (D1000231 s/n C4Q001 aka D1400087)
: Not sure of name : F2-1C1 D1000223 s/n S1104077
*no feedthru screws?
CB1 , 1st Floor (was 1st Floor of BSC6 CB) D1000921 s/nS1104116 CB-entry, 2nd floor Picomotors (D1000238 s/n1104586)
: Not sure of name : F2-2C2

D1000225 s/nS1106887 (replacing D1000223)

 

CB1 , 2nd Floor (was 4th Floor of BSC6 CB) D1000921 s/nS1104114 CB-entry, 1st floor Beam Diverter (D1000237 s/nS1104289)
Comments related to this report
betsy.weaver@LIGO.ORG - 15:41, Friday 07 March 2014 (10616)

Jim and Travis connected all of the TMS cables to the in-vacuum feedthrus.  This required completely rerouting 2 of the cables which were destined for feedthru's further away than where they were found mounted.  None of them are screwed in.  Although the ones that Corey mentions in the table above are missing hardware, they are a tight fit on the feedthru so I would advise just leaving them as is.  The task of adding the screws to the connectors is too risky for the cable this late in the game.  Adding the screws requires one to partially disassemble the cable which could cause a break inside of the connector.

keita.kawabe@LIGO.ORG - 15:46, Friday 07 March 2014 (10618)

And I enabled the damping and it's working.

However, it seems like LF coil is totally out, so TMSY might not be completely free.

H1 SEI (ISC)
hugh.radkins@LIGO.ORG - posted 09:02, Friday 07 March 2014 - last comment - 09:23, Friday 07 March 2014(10602)
ETMX HEPI(NOT)/ISI Move re Sheila's 10596

While I certainly appreciate the acumen of Stefan and Sheila on all things interferometeric, I showed yesterday in 10580 that HEPI did not move.  That said I do understand not always being able to catch all alogs that go in, I'm sure I'm very behind in my reading there too.

A couple things, that was not a glitch in HEPI, it was a trip condition that lasted for ~1.5+ hours.  I'm not sure how to figure out exactly what caused this trip in HEPI but the trend would suggest it is the last time this HEPI tripped and the MEDM says it was SUS.

I see ISI target changes on Tuesday and Thursday on stage1 timed with the HEPI Trips--likely model restart and ??  I suspect Stage2 sees this too.  This certainly will regulary impact alignment if it is recurring.  I think Sebastian must look through this closely and propose preventive measures here.

Comments related to this report
sebastien.biscans@LIGO.ORG - 09:23, Friday 07 March 2014 (10603)

I've been talking to Arnaud, and there is a high probability that the target values were changed by Arnaud/Sheila on Thursday.

I'll talk more with them to see if we want to keep those new values or go back to the previous ones.

H1 SEI (ISC)
hugh.radkins@LIGO.ORG - posted 09:02, Friday 07 March 2014 (10601)
ETMX HEPI(NOT)/ISI Move re Sheila's 10596

While I certainly appreciate the acumen of Stefan and Sheila on all things interferometeric, I showed yesterday in 10580 that HEPI did not move.  That said I do understand not always being able to catch all alogs that go in, I'm sure I'm very behind in my reading there too.

A couple things, that was not a glitch in HEPI, it was a trip condition that lasted for ~1.5+ hours.  I'm not sure how to figure out exactly what caused this trip in HEPI but the trend would suggest it is the last time this HEPI tripped and the MEDM says it was SUS.

I see ISI target changes on Tuesday and Thursday on stage1 timed with the HEPI Trips--likely model restart and ??  I suspect Stage2 sees this too.  This certainly will regulary impact alignment if it is recurring.  I think Sebastian must look through this closely and propose preventive measures here.

H1 ISC
sheila.dwyer@LIGO.ORG - posted 00:39, Friday 07 March 2014 (10599)
realingment tonight, ALS COMM locking

In addition to realigning the TMS, I also moved ETMX, ITMX, PR3, PR2 and IM4 tonight. 

I initially aligned the straight shot to ISCT1 using TMS and the baffle diodes, then PR3 for the camera spot.  Then I locked the cavity and tried engaging WFS.  I was able to engage PIT DOF1 and YAW DOF 1, and although the error signals were eventually brought to zero, the cavity build up dropped compared to the hand alignment.  The spot position also moved away from the spot on the camera that I had centered the single shot beam to.  I tried engaging PIT DOF2, but the gain was set to 0, and has been for a few days. I tried a gain of 1, which was bad, and a gain of 0.1 which seemed to have no impact. 

I gave up on the WFS and alinged the cavity by hand.  By moving TMS in pitch I was able to get the cavity build up to 800 counts again, so I decided to abandon WFS for tonight and go on to locking COMM.  The ALS_XARM guardian now has states for WFS. 

I was able to lock COMM using the guardian, and it was stable tonight with high gain ( I mean that the lock didn't drop unless I did something).  The noise measured by the linearize error signal is a bit worse tonight, 200Hz.  The first higher order modes were resonanting at the frequency were we though we had found the 00 mode last night.  I found the 00 mode at -5990Hz, and tweaked up the alingment using IM4 and PR2. 

Right now IM4 is at PIT -3077 YAW -5707 PR2 at 445 YAW at -383.1  I didn't save these using the IFO align screen in case the red team wants to restore their alignment from this morning using the current saved offsets. 

I did save TMSX, ETMX, ITMX and PR3.

H1 CDS
sheila.dwyer@LIGO.ORG - posted 00:27, Friday 07 March 2014 - last comment - 07:53, Friday 07 March 2014(10598)
Timing system problem

After I restarted the corner beckhoff machine, the timing system did not come back.  I has an error on Corner Master A, Fanout 15, VCXO control voltage.

Comments related to this report
daniel.sigg@LIGO.ORG - 07:53, Friday 07 March 2014 (10600)

This is due to the EY fanout. It's readback of the VCO voltage seems broken since the OAT days.

H1 SEI
sebastien.biscans@LIGO.ORG - posted 21:57, Thursday 06 March 2014 (10597)
BSC-ISIs tilt decoupling

I've installed tilt decoupling on:

- ST1 BS

- ST2 ITMY

 

I've started working on ST2 ETMX & ITMX but haven't finished yet. I'll kkep going as soon as I have access to the platforms.

 

For the curious ones, you can find the DTT templates with the results of the tilt decoupling into the SVN:

/ligo/svncommon/SeiSVN/seismic/BSC-ISI/H1/<CHAMBER>/Data/Transfer_Functions/Measurements/

H1 ISC (ISC, SEI, SUS)
sheila.dwyer@LIGO.ORG - posted 20:41, Thursday 06 March 2014 (10596)
something happened to end X alignment yesterday

Stefan briefly mentioned in his alog last night that something happened with HEPI that caused them to realing etmx and TMSX

Today I tried to check the TMSX alingment using the baffle PDs, and found them 25 urad away from the saved positions  (I've saved new posoitions for both PDs and the aligned state).  For the record the positions were:

PD1 202.9 P -232 Y PD4 272 -293.8 saved

PD1 204.3 P -207 Y PD4 274 P -269 today aligned 238.15 -237.9

I've attached a screen shot of the CPS positions, after a glitch in HEPI stage 1 move by 10 urad, and stage 2 by about 15 urad in RZ.  According to Sebastian the total yaw the TMS would see will be the sum of these, so the ISI move explains the required move of TMS.

Images attached to this report
H1 SUS (ISC)
jeffrey.kissel@LIGO.ORG - posted 19:10, Thursday 06 March 2014 (10595)
H1 SUS ITMX PUM / L2 Coils Balanced
J. Kissel

Following the same procedure outlined in LHO aLOGs 9453 and 9079, I balanced the coils on the PUM stage of H1 SUS ITMX. The final balanced gains in the L2_COILOUTF bank are

H1 SUS ETMX
Channel     Balanced COILOUTF Gain
L2 UL            +0.909
L2 LL            -0.965
L2 UR            -1.035
L2 LR            +1.099

The precision to which we could balance the coils was limited by the really windy day ground motion, but we believe the obtained values are good to within +/- 0.5%.

This balancing has reduced the L3 P and Y caused by a L2 pringle excitation at 4 [Hz] by
   DOF                  Reduction Factor @ 4.0 [Hz]
    P                          > 14.6      (peak below the noise, and totally incoherent)
    Y                          > 10.1      (peak below the noise, and only ~45% coherent)
The attachment shows the result from which these values were obtained, comparing the optical lever ASD at 4 [Hz] driven from L2 at the same amplitude for both balanced and unbalanced configurations.
Non-image files attached to this report
H1 SEI (PEM)
jeffrey.kissel@LIGO.ORG - posted 17:08, Thursday 06 March 2014 (10594)
H1 ISI ETMX Front-end Model Bug Fixed -- End X T240 Now in Frames
J. Kissel, C. Ramet, S. Biscans, B. Lantz

While grabbing data for the windy day today, I found that the temporary T240 that has installed at the X end station (see LHO aLOG 9758) was not being read out by the channels H1:ISI-GND_ETMX_{X,Y,Z}_DQ, and therefore not stored in the frames as expected. I found that the bug was in the ISI's front-end model where the channels on which the T240 were coming in were piped into the spigots for the "A" STS right off of the ADC, where it should be piped into "B." Check out D1400077 for more details and detailed redlines to both the analog wiring diagram and Simulink front-end wiring diagram. Finally, I've filled in the STS2CART matrix such that the T240 is now properly piped into the ground sensor correction path.

 
H1 SEI (INS)
hugh.radkins@LIGO.ORG - posted 16:47, Thursday 06 March 2014 (10593)
WHAM4 SEI HEPI Progress/Status

Mitchell and I got one more set (Pier 1, NW) of HEPI Actuators installed.  We ran into a problem though with the tilted tripod bar running into the Sensor Holster and locking up losing adjustablility.  I've noticed the closeness of this before but had never heard of a problem from LLO HEPI experience.  Anyway, we could not adjust the position to center the sensor without jamming/tilting the holster and locking it into position.  So we've taken the holster off and will mil it down a bit to give it some more clearance.  Definitely an issue to watch for during commissioning incase we incounter problems when adjusting Sensor Zero.  See attached sketch for idea of problem.  Who'd a thunk 30mils clearance would never be too little?

Non-image files attached to this report
H1 INS (SEI)
jim.warner@LIGO.ORG - posted 16:41, Thursday 06 March 2014 (10592)
ETMY ISI tf troubles

I tried running tf's on ETMY last night, but was foiled by my lack of understanding of the ETM sus overview screen (see Jeff's log # somethingorother). After SUS finished up alignment, I went down and unlocked the ISI to try again. After several hours of fruitless DTT tf's I'm giving up for now. I went down this morning and fiddled with the cables some, we tried several quad configurations (normal damping, increased pitch damping and all off), but have only managed to get worse, not better. The best guess we have right now is that maybe TMS is causing the badness (they are unplugged and can't damp at all) , but it doesn't seem a good guess because they weren't damped on the test stand (I think). More digging tomorrow, Arnaud wants the chamber for tonight.

 

For context, the attached DTT shows one degree of actuation and 3 associated sensors. Each curve  should kind of look like the red trace, make a peak(s, 3 seems normalish for this chamber) @ 1hz , then a valley @2.5hz, then another peak(s) @ 5hz. The extra notches at 2, 4 and 9.5 hz are "bonus", or maybe "bogus".

Images attached to this report
H1 General
jeffrey.bartlett@LIGO.ORG - posted 16:15, Thursday 06 March 2014 (10591)
Ops Summary
LVEA Laser Hazard

08:43 Justin – Working on IOT2R table
09:27 Betsy, Travis, & Jason - End-Y working on ETM-Y alignment
09:30 Jax – End-Y working on table
09:30 Andres – LVEA SUS test stand working on BOSEMs
09:30 PSL Status is good. All parameters are OK
10:30 Rick & Chris – Working in H2-PSL enclosure 
10:45 Rick – Craning items over beam tube
11:17 Karen – Finished cleaning at HAM4 and HAM5 area
11:44 Andres – Out of SUS Test Stand 
13:06 Karen – Going to End-Y
13:30 Hugh & Mitch – HEPI work at HAM4
14:50 Karen – Finished cleaning at End-Y
15:03 Patrick – Going to Mid-Y 
15:46 Patrick – Back from Mid-Y
16:00 Hugh & Mitch – Finished in LVEA

LHO VE
kyle.ryan@LIGO.ORG - posted 15:59, Thursday 06 March 2014 (10590)
Connected portable RGA to (2) in-series 1.5" angle valves at 10" gauge pair gate valve on Y1 (near GV6)
Pumps not running -> RGA connecting plumbing at atmospheric pressure -> Will pump down and bake assembly in-situ at some point in the next few days while connected to but isolated from Y1.
H1 SUS (ISC, SEI)
jeffrey.kissel@LIGO.ORG - posted 15:05, Thursday 06 March 2014 (10589)
Misaligning ITMs for ISI Tilt Decoupling
J. Kissel, S. Biscans

While the PRCL team is tuning their PLL parameters, and don't need the BSC chambers, I've misaligned ITMX and ITMY such that Sebastien can do tilt-decoupling without interfering with the input arm that PRCL still needs. Note, my metric for misaligned was steering he optic off the optical lever in both pitch and yaw.
           Aligned    Misaligned
ITMX P      +48.2        +208.2   
ITMX Y      -50.2        -220.2
ITMY P      +38.7        +138.7
ITMY Y     -142.3        -277.3