jameson.rollins@LIGO.ORG - posted 20:11, Tuesday 18 March 2014 - last comment - 12:13, Wednesday 19 March 2014(10855)
supervised guardian nodes unable to talk to h1ecatx1 Beckhoff

For some reason (maybe related to the CDS boogie man???) the supervised guardian nodes (ie. the nodes running under the guardian supervision infrastructure on h1guardian0) are unable to talk to any of the h1ecatx1 TwinCat IOC channels.

Sheila first noticed this when guard:ALS_XARM was not able to connect to the H1:ALS-X_LOCK_ERROR_STATUS channel.  The truly weird thing, though, is that all other channel access methods can access the h1ecatx1 channels just fine.  We can caget channels from the command line and from ezca in python.  We can do this on operator workstations and even from the terminal on h1guardian0.  It's only the supervised guardian nodes that can't connect to the channels.

I tried reloading the code, restarting the guardian nodes, nothing helped.  The same problem regardless of which node was used.  Note:

I'm at a loss.

There's clearly something different about the environment inside the guardian supervision infrastructure that makes this kind of failure even possible, although I honestly have no idea what the issue could be.

I'm going to punt on trying to spend any more time diagnosing the problem, since I'm just going to chalk it up to the other weirdness.  Hopefully things will fix themselves tomorrow.

Comments related to this report
sheila.dwyer@LIGO.ORG - 22:45, Tuesday 18 March 2014 (10858)

The other thing to note is that I did an svn update on that computer right before it crashed, it might be worth looking at what was included in the update to see if it changed the behavoir of the IoC somehow.  

cyrus.reed@LIGO.ORG - 12:13, Wednesday 19 March 2014 (10866)

(As also discussed in person.)  This may be due to a difference in the environment setup between the Guardian supervisors, and a login shell.  The EPICS gateway processes are still in place on the FE subnet, as we have not changed the data concentrator or FE systems to directly broadcast to other subnets.  So, the channel behavior will be dependent on the setting of the EPICS_CA_ADDR_LIST environment variable, specifically whether CA will traverse the gateway or route through the core switch.  The problem described sounds a lot like the issue the gateway has with reconnecting to Beckhoff IOCs, if the Guardian processes are connecting to the gateway then this would explain the behavior described.  Jaime was going to look at the Guardian environment setup as time permits, to see how it differs from the current cdscfg setup.

H1 CDS
sheila.dwyer@LIGO.ORG - posted 19:53, Tuesday 18 March 2014 - last comment - 12:00, Wednesday 19 March 2014(10854)
camera names disappeared

some of the digital video cameras used to have names, that appeared in on the links in the H1VIC_DIGITAL_OVERVIEW.adl screen. 

The names disappeared sometime this afternoon, maybe related to the deleted files?

Comments related to this report
cyrus.reed@LIGO.ORG - 09:18, Wednesday 19 March 2014 (10859)

The overview is one of the files that went missing.  I had an older copy saved elsewhere which I restored so as to provide access to the cameras, but this does not have the (later) name updates.  Once the backup copies are retrieved from tape, I should be able to restore the latest version.  It was also an oversight that these were not in SVN, which will also be corrected.

cyrus.reed@LIGO.ORG - 12:00, Wednesday 19 March 2014 (10865)

I have restored the latest version of the camera screens, they have also been added to the useraps repo in cds/h1/medm, and symlinked in the /opt/rtcds/lho/h1/medm/cds area.

H1 SUS (CDS, DAQ, INS, ISC, SEI, SYS, VE)
jeffrey.kissel@LIGO.ORG - posted 19:03, Tuesday 18 March 2014 (10849)
Loose Wires in the Software
J. Kissel, S. Dwyer, D. Sigg, J. Rollins, A. Pele, H. Radkins, D. Gustafson, F. Clara, C. Reed, J. Batch, D. Barker

So, maintenance day was awesome. In summary, we had two problems that took us 4 hours to identify:
(1) The h1sush2a IOP model's DAC enable bit had gone bad after Sheila's restart of the h1suspr3 model. This resulted in the mode cleaner misalignment, because alignment offsets were not getting out to the SUS. This has happened several times before, see for example LHO aLOGs 10375, or 8964.
(2) Some of the /opt/rtcds/lho/h1/ directory structure has disappeared for an as yet unknown reason. This resulted in the mode cleaner blowing up the FSS every time it tried to LOCK.

The story, in chronological order for the record:

- Kiwamu and I flip HXTS signs, store new safe snapshots, and leave with the IMC locked. (see LHO aLOG 10837)
- Sheila installs optical lever BLRMS into PR3 by restarting the h1suspr3 front end code, which is on h1sush2a computer. (see LHO aLOG 10837)
- Restarting the SUS front end model trips the HAM2-ISI watchdogs (but NOT HPI), because the ISI loses communication with the SUS.
- Found the IMC TRANS and REFL cameras appearing grayed out, appearing to be broken / not reporting real data
- Sent Fil out to check if the camera's analog path has been screwed up some how. Confirms OK.
- Fil launched Cyrus and had him reboot the camera server processes on the relevant cameras and there's no affect.
- Sheila, Arnaud, Hugh, and Daniel launch on the "has the alignment changed since we last had a good lock, and to what SEI trips does the change correspond" DataViewer trending game. Red herrings everywhere, Daniel finally identifies that the IMC is just misaligned. The cameras look bad because of some automatic exposure or gain or aperture were searching for light and found none.
- Jim restarts the DAQ (see LHO aLOG 10832)
- Jamie identifies the h1sush2a IOP model's DAC enable bit had gone bad, because of his previous experience with the problem. We all look at the h1sush2a's IOP CDS bit word (one bit in the middle of a bit word, that is un-intuitively related to MC1 and MC3), and find, sure enough, the bit is red.
- Talk to Jim who says the way to solve the problem is to kill all user front-end processes, and restart the IOP process, and restart all the user processes.
- Performing Jim's FIXIT works, and we can drive out of MC1 and MC3 (and the rest on h1sush2a, PRM and PR3) again.
- We used the guardian to bring each SUS back into the aligned state, and turned on the IMC guardian.
- The IMC aligns, but is constantly flashing, breaking the FSS lock constantly during attempts to lock.
- After bringing up all the front end processes, while the DAC enable problems disappeared, we were left with IPC errors in the CDS bit words for 3 of he 4 SUS.
- Looking to clear these errors because they're a suspect, we tried opening the GDS TP screens to hit the "Diag Reset" button, only to discover that MEDM throws and error when SUS GDS_TP screens are called, complaining they don't exist.
- Looking into the /opt/rtcds/lho/h1/medm/ folder, we find that *all* SUS, and several more automatically generated MEDM directories have disappeared.
- Launched Jim and Dave to investigate, continuing to explore why the IMC won't lock (see LHO aLOG 10850)
- Sheila and I toggle switches, BURT restore h1lscepics, h1ascimcepics, h1ecatc1plc2 to 2014-03-18 14:00 PT with no affect
- Sheila checks analog IMC error signal (demod phase) and cabling at ISC racks. Everything looks great.
- Jim, beginning to replace all of the missing MEDM files, begins systematically make-installing all missing models.
- When he gets to h1susmc2 BLAMO -- the IMC locks right up.
- Dick titles the aLOG.


As I said, still unclear why all of these files when missing, but some ~200 files were apparently *non-MEDM* files, and *some* of those files were essential for the IMC to lock. YAAAAAAAY MAINTENANCE DAY YAAAAAAAAY.

The investigation continues on why we lost files from /opt/rtcds continues, in the mean time, Jim has reinstalled all models with the missing files, and things appear functional, but we've test little else than the IMC.

H1 CDS (CDS, DetChar, ISC, PEM, PSL, SEI, SUS, TCS)
james.batch@LIGO.ORG - posted 18:56, Tuesday 18 March 2014 (10853)
Files deleted from /opt/rtcds
A massive number of files were deleted from /opt/rtcds under mysterious circumstances this afternoon between 1:20 and 4:20 PM PDT.  We checked for intruders, and inquired about creative or rogue scripts, but found nothing.  The largest number of files were deleted from /opt/rtcds/lho/h1/medm.

To restore the medm files, make install was performed on the following models:

h1iopsusb123, h1susitmy, h1susbs, h1susitmx, h1susmc1, h1susmc3, h1susprm, h1suspr3, h1iopsush2b, h1susim, h1susmc2, h1suspr2, h1sussr2, h1sussr3, h1sussrm, h1susomc,
h1iopsusauxb123, h1susauxb123, h1iopsusauxh2, h1iopsusauxh34, h1iopsusauxh56, h1susauxh56, h1iopseib1, h1iopseib2, h1iopseib3, h1hpiitmx, h1iopseih16, h1hpiham6
h1isiham6, h1hpiham3, h1isiham2, h1isiham3, h1iopseih45, h1hpiham4, h1hpiham5, h1isiham5, h1ioppemmy, h1pemmy, h1ioppsl0, h1pslfss, h1pslpmc, h1psldbb, 
h1iopoaf0, h1peml0, h1tcscs, h1odcmaster, h1omc, h1iopasc0, h1ascimc, h1sushtts, h1ioppemmx, h1pemmx, h1iopsusey, h1iopsusex, h1iopseiey, h1hpietmy, h1isietmy,
h1isietmx, h1iopiscey, h1pemey, h1iscex, h1odcy, h1odcx, h1iopsusauxey, h1iopsusauxex, h1susauxex.

Additionally, h1susetmx required a make, make install to be performed because the h1susetmxepics directory was missing from the build, even though it had been built shortly after noon today.

The SITEMAP.adl file or symbolic link was missing from medm, so a symbolic link was created to the SITEMAP.adl file in userapps.  Links to other adl files were missing as well.

We do have a complete list of missing files and will evaluate which files should be restored from backup tapes tomorrow.
H1 CDS
sheila.dwyer@LIGO.ORG - posted 18:46, Tuesday 18 March 2014 (10852)
h1ecatx1 crashed

I was logged in to see why the system wasn't running, and the machine crashed.  It restarted and I burt restored all three pls (h1ecatx1plc, 2, and 3) to 14:00 today.

H1 CDS
david.barker@LIGO.ORG - posted 18:38, Tuesday 18 March 2014 (10850)
mysterious deletion of files from h1boot /opt/rtcds

We are currently investigating a loss of files from the h1boot /opt/rtcds file system. It appears to have happened between 1pm and 4:20pm (when it was discovered). We are restoring the files both from tape backup and by reinstalling from model RCG install scripts. We are investigating the cause of the loss.

H1 ISC
corey.gray@LIGO.ORG - posted 18:08, Tuesday 18 March 2014 (10824)
EY TMS GREEN Beam Alignment Work & QPD Servo

(Corey, Jax, Keita)

Continue with getting a GREEN beam onto the TMS table.  We had to make more position changes for the GREEN Top Periscope Mirrors (this required using longer screws for the top dog clamps [see photo]).  Then most of the time was spent pointing the beam onto TMS.  Once on the TMS, the beam was then pointed onto the QPDs first with a TMS Periscope mirror, but most of it was via ISCTEY mirrors by Jax.  We went through several iterations of tweaking to stay centered on the mirrors and to also have a beam nice & centered on the ISCTEY periscope mirrors (this involved some nap time in the chamber while Jax did all the work outside [see photo]).

Through this alignment work, we could see the retro-reflected beam off the ETM on the TMS Telescope Mirrors.  On the Secondary mirror the spot looks to be low and little off in yaw.  To fix the pitch, we will need to pitch the TMS "back" via the slider weights under the table.

Additionally, during this alignment work, the QPD servo was engaged & is operational!

Images attached to this report
H1 ISC
keita.kawabe@LIGO.ORG - posted 17:58, Tuesday 18 March 2014 (10848)
QPD servo works (Jax, Corey, Keita)

We aligned the ALSY green beam to the TMSY, and confirmed that the QPD servo works.

Tomorrow we'll rebalance the TMSY to get the ALS beam retro-reflected off of the ETMY.

H1 General
jeffrey.bartlett@LIGO.ORG - posted 16:22, Tuesday 18 March 2014 (10847)
Remove Frayed Tag Line over HAM5
Filiberto & Jeff

  The Apollo crew spotted a frayed nylon tag line in the cable tray over HAM5 (good catch Apollo). This tag line has been removed from over the HAM5 chamber, and will be replaced before any more cable pulling is done in this area.  
H1 SUS
jeffrey.bartlett@LIGO.ORG - posted 16:17, Tuesday 18 March 2014 (10846)
Broken Magnet on H1-SR3
This afternoon, while adjusting the AOSEMs on the H1-SR3 Intermediate Mass, the UL Magnet/Dumbbell assembly was knocked off by making contact with the ceramic boards holding the PD/LED. We will reattach a new Magnet/Dumbbell assembly tomorrow. 
H2 SEI
mitchell.robinson@LIGO.ORG - posted 15:49, Tuesday 18 March 2014 (10845)
Staging building, 3IFO (unit 3) progress
Mitchell,
The two monolithic plates have been assembled and the 0-1 blade spring posts have been added. A cleaning in the granite table clean room has been set up. Apollo will be working with C&B tomorrow to wrap and deliver the optical tables which are next up for a helicoil makeover. 
LHO General
thomas.vo@LIGO.ORG - posted 15:43, Tuesday 18 March 2014 (10844)
03/19/2014 Ops Summary
Maintanence: 
- Ace on site for portables
- Update .Net4 on Windows Virtual Machine
- PraxAir at EX
- DAQ Restart
- Sheila adding OpLev BLRMS to suspension models, prototype of ECR 1400155

- Cycle GV7 for craning
- Crane cleanroom at HAM5
- Move TCS tables to position
- Crane TCS cabinets
- Jodi at MY for 3rd IFO
- Karen at MY for cleaning
- Gerardo and Dave O. in H2 PSL enclosure for OFI alignment, using laser.
- Betsy and Travis in west bay
- Andres and Jeff B at HAM4&5
H1 SEI (INS, ISC)
hugh.radkins@LIGO.ORG - posted 15:39, Tuesday 18 March 2014 (10843)
ETMY HEPI Test Pending

ISC is working late(r than me) so I've got a pending HEPI measurement planned to start between 8 & 830 tonight.  I need the payload untripped as well as the HEPI to allow this to work.  JeffK has agreed to untripped all the necessary watchdogs.  ISC--please let him (or his handoff) know when you are done.  Or you could untrip the payload and HEPI when you are done for me.  Thanks all--H

LHO VE
kyle.ryan@LIGO.ORG - posted 15:36, Tuesday 18 March 2014 (10842)
Closed Y1-1 10" gate valve for test -> PT124B effected
Part of pre-Y1 accumulation test preparations -> Y1-1 10" gate valve open now -> PT124B measuring BT pressure again, i.e. normal confifuration
LHO VE
john.worden@LIGO.ORG - posted 15:24, Tuesday 18 March 2014 (10840)
Pressure excursions at PT124 - Mounting RGA at BEAm Tube Port

Note,

We are prepping for BT accumulation measurements and therefore Kyle is mounting and commissioning an RGA at the Beam Tube pump port which houses PT124. Reference Work permit #4508.

Expect PT 124 to range from 1E-9 to 1 E-6 torr while this work takes place. For the actual accumulation the mid station gate valve will also be closed and PT 124 as well as PT243 will begin to rise. The accumulation period may be as long as 48 hours.

 

H1 SUS (ISC, SYS)
jeffrey.kissel@LIGO.ORG - posted 15:22, Tuesday 18 March 2014 (10837)
HXTS Lower Stage Signs Have been Flipped
J. Kissel, S. Dwyer, K. Izumi

As of LHO aLOG 10702, we'd identified that the sign convention for the lower two stage coil/magnet compensation of all HSTS and HLTS (i.e. the signs of the gains of the COILOUTF banks) had been wrong since basically forever, in that a +L request results in a -L. Today we've gone through each SUS, flipped the COILOUTF signs to obey convention, and compensated for the sign flip in all affected LSC loops (ASC loops are not affected, since we're only sending signals to the TOP mass at this point). We have since confirmed that the IMC re-locks and we've checked that PRMI stuff is OK by re-locking PRX.

We have captured all new safe.snaps for all the SUS and the LSC model, and subsquently committed all snaps and changes to guardian to the svn repo.

Change list:
(1) Changed sign in all M2 and M3 COILOUTF banks for 
MC1, MC2, MC3
PRM, PR2, PR3
SRM, SR2, SR3
to the following
        WAS     IS NOW
    UL   -        +
    LL   +        -
    UR   +        -
    LR   -        +

(2) For IMC L, we changed the analog sign on the slow (MCL) path in the IMC common mode board, just before the signal enters the LSC ADC, to change the overall sign of the LSC requested signal, as well as the top mass, M1 stage, LOCK filter sign, since it had already obeyed convention
                              WAS    IS NOW
H1:IMC-REFL_SERVO_SLOWPOL      -        +
H1:SUS-MC2_M1_LOCK_L_GAIN      +        -

(3) The IMC Guardian only touches the MC2 M1 LOCK L filter gain (to turn it on and off during lock acquisition), so we made sure that it sets the gain sign correctly.

(4) For the PRC, we changed the overall sign of the PRC loop in the LSC-PRCL bank, and then changed the MICH2PRM output matrix sign (the MICH2BS element is not affected, since it already obeyed convention).
                             WAS     IS NOW   
H1:LSC-PRCL_GAIN              -        +
H1:LSC-OUTPUT_MTRX_5_2        -        +

(5) We've modified the two Guardians responsible for PRX/PRY locking and 3f PRMI locking to make sure they set these gains correctly.
/opt/rtcds/userapps/release/lsc/h1/guardian/lsclib/prxy/carrierlock.py (PRX /PRY locking guardian)
/opt/rtcds/userapps/release/lsc/h1/guardian/lsclib/prmi/sidebandlock.py
H1 INS (SEI)
jim.warner@LIGO.ORG - posted 15:03, Tuesday 18 March 2014 (10838)
ETMY ISI test report posted

E1100846-v3. Still an early version, and I'm missing 2 minor tests, so when TMS feels they can give me a couple hour block. Otherwise SEI is in good shape, there.

H1 SUS
sheila.dwyer@LIGO.ORG - posted 14:45, Tuesday 18 March 2014 - last comment - 18:41, Tuesday 18 March 2014(10836)
Op Lev band limited RMS added to SUS models

Sheila, Jeff, Jim

We have added OpLev BLRMS to the suspension models for suspensions that have opLevs, this change is described in ECR E1400155

This involved changes to h1susetmx h1susitmx (since these are not using the quad master right now) QUAD_MASTER BSFM_MASTER and HLTS_MASTER

There is also a new medm screen in sus/common/medm/SUS_CUST_OPLEV_BLRMS

I also added a link to this screen in the op Lev screens :SUS_CUST_QUAD_L3_OPLEV.adl SUS_CUST_HLTS_M3_OPLEV.adl and SUS_CUST_BSFM_M3_OPLEV.adl

All of these changes are now committed to the svn. 

The models are running, and Jim has restarted the DAQ so the new channels are avaiable.  We also checked using dtt and a spectrum that the values diplayed are accurate.

Comments related to this report
jeffrey.kissel@LIGO.ORG - 15:30, Tuesday 18 March 2014 (10841)
The H1 SUS ITMY PUM coil balancing coefficients got lost in this reboot. I've restored their values according to LHO aLOG 10625, captured, and committed a new safe.snap.
sheila.dwyer@LIGO.ORG - 18:41, Tuesday 18 March 2014 (10851)

I also placed two strip tools, the top one for at the microseism frequency, 30-100mHz, and one for the suspension resonance frequencies, 0.3-1Hz.  on the monitor on the wall next to the PEM FOMs.  I moved the Osem screen over to the other side of th control room.  We can change around the settings on these plots to make them more usefull if it turns out they are too hard to read. 