Displaying reports 7881-7900 of 89132.Go to page Start 391 392 393 394 395 396 397 398 399 End
Reports until 11:43, Monday 31 March 2025
LHO VE
david.barker@LIGO.ORG - posted 11:43, Monday 31 March 2025 (83661)
Mon CP1 Fill

Mon Mar 31 10:09:31 2025 INFO: Fill completed in 9min 28secs

 

Images attached to this report
H1 PSL
ryan.short@LIGO.ORG - posted 10:10, Monday 31 March 2025 (83659)
PSL 10-Day Trends

FAMIS 31079

The temperature increase noted last week seems to have come back to normal for the most part after a few days.

Jason's RefCav alignment tweak 3 days ago is clearly seen and level has stayed relatively stable since.

PMC Refl hasn't been rising, but perhaps has gotten noisier starting a few days ago.

Images attached to this report
H1 ISC
sheila.dwyer@LIGO.ORG - posted 08:46, Monday 31 March 2025 (83655)
POP 18 gains restored to their previous normal gain of 2

Last week Corey changed the gains of POP18 because of difficulties locking DRMI.  83540  To avoid having the histories of these POP18 build ups being confusing, I've moved the gain of 2 into the trigger matrix, and in sdf set the locking gains back to 2.  (These gains were changed from 1 to 2 when the 50/50 splitter was added to the POP path.) 

I've edited line 238 in ISC_DRMI to set the trigger matrix element to 2.

Images attached to this report
H1 General (Lockloss)
ibrahim.abouelfettouh@LIGO.ORG - posted 07:41, Monday 31 March 2025 - last comment - 09:16, Monday 31 March 2025(83653)
Lockloss 14:39

Lockloss after 2 minute lock before reaching observing. No immediate apparent causes.

Comments related to this report
ryan.crouch@LIGO.ORG - 09:16, Monday 31 March 2025 (83657)

Appears to have been an ETMX glitch

Images attached to this comment
LHO General
ibrahim.abouelfettouh@LIGO.ORG - posted 07:36, Monday 31 March 2025 - last comment - 09:01, Monday 31 March 2025(83652)
OPS Day Shift Start

TITLE: 03/31 Day Shift: 1430-2330 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Lock Acquisition
OUTGOING OPERATOR: Ryan S
CURRENT ENVIRONMENT:
    SEI_ENV state: CALM
    Wind: 28mph Gusts, 23mph 3min avg
    Primary useism: 0.06 μm/s
    Secondary useism: 0.21 μm/s
QUICK SUMMARY:

IFO is LOCKING in LASER_NOISE_SUPPRESSION

Today we have planned comissioning from 8:30 to 11:30 local time.

The last lockloss seems to have been caused by wind and elevated microseism, though neither seem high enough to have necessarily caused a lockloss.

Comments related to this report
camilla.compton@LIGO.ORG - 08:59, Monday 31 March 2025 (83654)DetChar, DetChar-Request

Ibrahim, Oli, Camilla

We had two 30+ minute range drops last night, plot attached. Looks to be mainly under 60Hz from the OMC BLRMs, plot.

Doesn't appear to be sqz, EX ground motion 83233, or CO2 ISS channel 82728 related. Oli also checked this wasn't PI related 82944.

Images attached to this comment
oli.patane@LIGO.ORG - 09:01, Monday 31 March 2025 (83656)SUS

Confirmed not the PIs for either range drop (drop1, drop2). There was a small drop in range a few minutes before the second range drop around the same time as PI31 had a small ringup, but zooming in, the ringup happened multiple minutes before and so doesn't account for that quick drop either(ndscope3).

Images attached to this comment
LHO General
corey.gray@LIGO.ORG - posted 21:59, Sunday 30 March 2025 (83649)
Sun EVE Ops Summary

TITLE: 03/30 Eve Shift: 2330-0500 UTC (1630-2200 PST), all times posted in UTC
STATE of H1: Observing at 154Mpc
INCOMING OPERATOR: Ryan S
SHIFT SUMMARY:

Nice shift with H1 running decently even as the weather turned a bit in the evening (w/ 30+mph winds and rain as the sun set....but then calmed down toward the end of the shift).  At shift's end, H1's current lock is over 7hrs (with one GW-candidate).
LOG:

H1 CDS
david.barker@LIGO.ORG - posted 17:00, Sunday 30 March 2025 - last comment - 22:48, Sunday 30 March 2025(83650)
VACSTAT alarm on BSC3 sensor glitch

We had a BSC3 sensor glitch at 16:39:16 resulting in a single VACSTAT alarm. I restarted the service at 16:50 to clear this alarm.

I also set the FMCS Reverse Osmosis alarm into silent mode so it will only email and not text for the next 24 hours.

Bypass will expire:
Mon Mar 31 04:57:28 PM PDT 2025
For channel(s):
    H0:FMC-CS_WS_RO_ALARM
 

Comments related to this report
david.barker@LIGO.ORG - 22:48, Sunday 30 March 2025 (83651)

Another BSC3 VACSTAT glitch at 22:40:58. Service was restarted at 22:27 to clear.

LHO FMCS
ryan.crouch@LIGO.ORG - posted 16:31, Sunday 30 March 2025 (83642)
OPS Sunday DAY shift summary

TITLE: 03/30 Day Shift: 1430-2330 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Observing at 153Mpc
INCOMING OPERATOR: Corey
SHIFT SUMMARY: We've been locked for 1.5 hours. The ground has been doing the tectonic shuffle this morning with a group of earthquakes and aftershocks from Tonga, 7.0, 4.8, 6.1, 4.9, 5.8...
LOG: No log.

The porta potty outside the FCES has also been knocked over, and OSB receiving is blocked by tumbleweeds. (Tagging FMCS)

Images attached to this report
LHO General
corey.gray@LIGO.ORG - posted 16:25, Sunday 30 March 2025 (83648)
Sun EVE Ops Transition

TITLE: 03/30 Eve Shift: 2330-0500 UTC (1630-2200 PST), all times posted in UTC
STATE of H1: Observing at 152Mpc
OUTGOING OPERATOR: Ryan C
CURRENT ENVIRONMENT:
    SEI_ENV state: CALM
    Wind: 16mph Gusts, 11mph 3min avg
    Primary useism: 0.03 μm/s
    Secondary useism: 0.15 μm/s
QUICK SUMMARY:

H1 has been at NLN for 1.5+hrs. 

There is a CDS Alarm for the RO (reverse osmosis) system.  Happened to phone Tyler earlier today with water questions and he mentioned he turned off both RO skids this morning (@943amPDT).

Environmental noise wise, secondary µseism is lower than 24hrs (looks like it's flattened out squarely at the 50th percentile  about 7hrs ago).  Winds are a little are a touch more breezy than yesterday, but still well under 20mph.

H1 General (Lockloss)
ryan.crouch@LIGO.ORG - posted 13:42, Sunday 30 March 2025 - last comment - 15:01, Sunday 30 March 2025(83645)
20:34 UTC Lockloss

20:34 UTC lockloss, it appears to have been from an ETMX glitch

Images attached to this report
Comments related to this report
ryan.crouch@LIGO.ORG - 15:01, Sunday 30 March 2025 (83646)

21:55 UTC observing

LHO VE
david.barker@LIGO.ORG - posted 10:20, Sunday 30 March 2025 (83643)
Sun CP1 Fill

Sun Mar 30 10:11:04 2025 INFO: Fill completed in 11min 1secs

TC-B slightly noisy.

Images attached to this report
H1 General
ryan.crouch@LIGO.ORG - posted 07:30, Sunday 30 March 2025 - last comment - 11:16, Sunday 30 March 2025(83641)
OPS Sunday DAY shift start

TITLE: 03/30 Day Shift: 1430-2330 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Earthquake
OUTGOING OPERATOR: Ryan S
CURRENT ENVIRONMENT:
    SEI_ENV state: EARTHQUAKE
    Wind: 8mph Gusts, 5mph 3min avg
    Primary useism: 0.51 μm/s
    Secondary useism: 0.16 μm/s
QUICK SUMMARY:

Comments related to this report
ryan.crouch@LIGO.ORG - 11:16, Sunday 30 March 2025 (83644)

18:16 UTC Observing

LHO General
corey.gray@LIGO.ORG - posted 21:59, Saturday 29 March 2025 (83639)
Sat EVE Ops Summary

TITLE: 03/29 Eve Shift: 2330-0500 UTC (1630-2200 PST), all times posted in UTC
STATE of H1: Observing at 152Mpc
INCOMING OPERATOR: Ryan S
SHIFT SUMMARY:

Quiet shift with H1 locked the whole time (currently at about 7.5hrs).  Squeezed in a successful Calibration while L1 was down.  Secondary microseism continues downward trend from the last 24+hrs (touching 50th percentile line).  Winds touched ~20mph, but have mostly meen much calmer.
LOG:

H1 CAL (CAL)
corey.gray@LIGO.ORG - posted 18:58, Saturday 29 March 2025 (83640)
Saturday H1 Calibration Measurement (broadband headless + simulines)

After noticing that L1 was down, started running Calibration measurments since H1 was now thermalized.

Measurement NOTES:

Images attached to this report
Displaying reports 7881-7900 of 89132.Go to page Start 391 392 393 394 395 396 397 398 399 End