jason.oberling@LIGO.ORG - posted 10:51, Monday 04 November 2013 (8368)
WBSC3 ITMx Alignment

Log from last Friday, 1 Nov 2013.  Took a look at the ITMx after setting up the Brunson optical square from the End-X station.  Position errors and pitch/yaw as of 1 Nov 2013 are:

I took down the IAS equipment Friday afternoon to allow for this morning's cryopump baffle installation.  While that is happening SUS and SEI are making alignment adjustments.  When the cryopump baffle installation is completed I will set the IAS equipment up again and measure the results of the moves.

H1 SUS (SUS)
betsy.weaver@LIGO.ORG - posted 09:47, Monday 04 November 2013 - last comment - 13:11, Monday 04 November 2013(8367)
SRM rebalanced to aid in range of middle stage AOSEMs

Betsy, Travis

On Friday, we rebalanced the SRM suspension adding enough weight to the middle mass to bring it down such that the 2 AOSEMs which were maxed out in Z-position could be aligned.  These AOSEM brackets were poorly designed and we have found that many of the HSTSes at LHO (and likely at LLO, but awaiting their response) are built with the brackets at a range extreme.  So, while the SRM passed TFs the other week, we had to start over with balancing in order to bring these AOSEMs into alignment with a little bit of range adjustment.  Previously, the SRM had been balanced to within tolerance at ~0.75mm high.  Friday, we added enough weight to bring it to ~0.25mm low in order to bring the middle mass down a bit.  Note none of the other 12 OSEMs were out of range, just the 2 top ones on the middle mass.  Because of the rebalancing, Phase 2b TFs need to be run and evaluated again.

Comments related to this report
janeen.romie@LIGO.ORG - 12:24, Monday 04 November 2013 (8371)
Danny, Gary & Matt agree that we have not seen this problem here at LLO on any suspensions. 
Matt has gone over all of the photos he has of the in situ HSTSs and there are none at the extremes. 
Matt & Betsy will talk
janeen.romie@LIGO.ORG - 13:02, Monday 04 November 2013 (8372)
Matt, Betsy Jeff B & Janeen talked. Matt reminded that there were 2 different vendors for the HSTS weldments. It may be that the horizontals of the two different manufacturer's weldments are in different positions relative to the drawing. If, for example, some of the LHO crossbars are further apart than the LLO crossbars, then the range for those middle stage AOSEM brackets would be different. We are in agreement that if the suspensions meet the requirements - TF pass and optic center is in the right position relative to the optics table - then these differences are acceptable. 
janeen.romie@LIGO.ORG - 13:11, Monday 04 November 2013 (8373)
Matt has a couple of photos of HSTSs here at LLO, that show the relatively nominal position of these brackets.
The first photo is the back of LPR2. The second is the back of MC3. The last is the back of MC2. You'll need to zoom in on these photos to see the AOSEM mounting brackets.
Images attached to this comment
H1 SEI
hugh.radkins@LIGO.ORG - posted 09:44, Monday 04 November 2013 (8366)
WBSC3-ITMX HEPI is level1* locked

Maybe not necessary but caution is OK.  I locked the HEPI before ACB is swung back and SUS moves in to push the suspension around.

* Level1 locked is just using the outer vertical & four outer horizontal lock bolts.  The others are extemely difficult to access and for the entire platform, overkill.

H1 ISC (ISC, SUS)
sheila.dwyer@LIGO.ORG - posted 12:47, Sunday 03 November 2013 - last comment - 14:31, Monday 11 November 2013(8364)
Tip tilts for HAM 6 finsihed

Alexa, Keita, Stefan and Sheila-

We have the last optic mounted and balanced in a tip tilt (SN 33) for HAM 6 (OM3).  We had difficulty balancing this the optic in this tip tilt,  even with a short bolt, 2 nuts and a washer on the back side we could not balance it.  Keita brought out SN20 and 25 which are intended for India (and do not have cables attached).  We had a similar problem balancing one of these.  Keita then noticed that there is slop in the four scews that attach the piece that clamps the wire to the rest of the mirror holder (picture attached, these are the 2 bolts on top and the 2 bolts on the bottom of the photo.) The tip tilts we were able to balance had those screws centered in their holes while they were off center in the tip tilts we were unable to balance.  We centered them on the india tip tilt and then we were able to balance it using a dummy optic.  We then did the same thing on the TT that was originally intended to be the H1 spare (SN33).

In the process we used a dummy optic from iLIGO that has a scratch in the center to avoid chipping more real optics.  

We took parts from TT SN9:  the peak nudge  (which was missing from SN33), the small screw that tightens the balancing bolt (we dropped this) and one of the OSEM flags (one flag on SN33 was bent).  

In the end, we have not changed anything for the india tip tilts (SN 20 and 25) except correcting the position of the small bolts, we have 3 balanced and ready for HAM6 (SN2,4, and 33) and one H1 spare (SN9) which is missing parts and needs the wires reclamped.  

On monday I will double check all of the serial nubers written in this alog to make sure they are right.  

Images attached to this report
Comments related to this report
alexan.staley@LIGO.ORG - 14:31, Monday 11 November 2013 (8462)

As mentioned, last time we swapped the UL flag on SN 33 with the UL from SN 09 since the original one was slightly bent. I confirmed that the swapped flags have the same polarity, and is consistent with the previous polarity measurements done in this alog.

H1 TCS
greg.grabeel@LIGO.ORG - posted 15:35, Saturday 02 November 2013 (8363)
Mirror cleaning
Chris S. Joe D. Greg G.

With the help of Joe and Chris the SM1 mirrors (SN 3,4) were cleaned and are air-baking now, they should be done Monday evening. The SM2 mirrors were also completed recently and are wrapped and bagged and ready for install.
Images attached to this report
H1 SYS (SYS)
jeffrey.kissel@LIGO.ORG - posted 21:44, Friday 01 November 2013 - last comment - 13:56, Sunday 03 November 2013(8362)
RTS to RTS link test for IPC, EPIC read, EPICS write and EPICS write-read
(Stefan Ballmer - not Jeff)

I set up a test for diagnosing front end to front end communications via 4 separate routes:
1) IPC
2) EPICS read (pull data)
3) EPICS write (push data)
4) EPICS write and read, via a third epics server (push to 3rd server, pull from 3rd server)

The setup has a counter on H1odcmaster, this is sent via temporary IPC to h1ascimc, and then returned back to h1odcmaster via the 4 routes described above. For IPC and epics read operations I get an error flag, which I am reporting. No such thing is available for an epics write operation.

h1odcmaster is currently running at 32k, h1ascimc is running at 2k.

I calculated the following quantities
- DELAY          : round trip delay in sec
- DELAY mean     : averaged DELAY
- DELAY max:     : largest DELAY observed
- JITTER MAX     : largest time interval between updates
- JITTER MIN     : shortest time interval between updates
- JITTER MAX-MIN : = JITTER MAX - JITTER MIN, the peak-to-peak jitter
- JITTER RMS     : root-mean-square of the time interval between updates

Conclusion for now:
- No errors observed in the ~1h this was running
- No jitter on IPCs
- epics read has a faster update rate (~8Hz) than epics write (~2Hz)
- as a result the delay is shorter for epics read
- the jitter MAX-MIN is about 40msec for EPICS access - the RMS jitter is about 4msec

I turned on recording for all the fast return channels over the weekend.

The modifications to h1ascimc and h1odcmaster will be backed out on Monday.





Images attached to this report
Comments related to this report
jeffrey.kissel@LIGO.ORG - 13:56, Sunday 03 November 2013 (8365)CDS, SYS
Here is another snapshot after running for 2 days. No qualitative change.
Images attached to this comment
H1 PSL
sheila.dwyer@LIGO.ORG - posted 19:20, Friday 01 November 2013 (8361)
PMC not locked

The ref cav was not locked all day, I didn't get a chance to look at it until just now, but it seems like the problem is actually with the PMC. 

The indicators on the medm screen seem to think that the PMC is locked, but it does not look locked in the camera, and the reflected power is 12.5 W. 

 

H1 INS (INS, SEI)
jim.warner@LIGO.ORG - posted 16:54, Friday 01 November 2013 (8360)
TF running on ETMX ISI, again

TF's running on ETMX ISI. More reps, so this test will take longer. Running on opsws6.

LHO General (CDS, PEM)
patrick.thomas@LIGO.ORG - posted 16:30, Friday 01 November 2013 (8359)
Restarted IOC for dust monitor at end Y
Sometime yesterday one of the leads for the DC power cable between a lab power supply and the Comtrol at end Y got disconnected. Richard went out and fixed it. I restarted the IOC for the attached dust monitor at 13:37. I later burtrestored it.
LHO VE
kyle.ryan@LIGO.ORG - posted 16:06, Friday 01 November 2013 (8358)
1505 hrs. local -> Resumed pumping GV6's leak sleeve


			
			
H1 General
andres.ramirez@LIGO.ORG - posted 15:59, Friday 01 November 2013 (8357)
Ops Shift Summary
Roofers on the roof!
Removal of east and west doors from Ham 3 – Apollo
Checking dust monitors in LVEA – Richard
Dust monitor (unit #10) installed by HAM 3 – Richard
Baffle work in LVEA (West bay) – Mitchel/Thomas Vo
Working at End Y – Alexa
WBSC9 ETMx Alignment - Jason
Cable work from HAM3 to HAM6 – Filiberto
Delivery for Richard – PLATT Electric Supply
Vented sleeve surrounding GV6's gate annulus piping leak - Kyle
H1 AOS
jason.oberling@LIGO.ORG - posted 11:29, Friday 01 November 2013 (8356)
WBSC9 ETMx Alignment

Took a look at the ETMx this morning to asses the alignment after the HEPI actuator install was completed.  As a reminder the large X axis positional error has been signed off by SYS, no correction will be performed.

IAS is now moving full time to the ITMx in WBSC3.  We will have to return to the ETMx to fine align the optic pitch and align the ETMx ACB.

H1 INS (INS, SEI)
jim.warner@LIGO.ORG - posted 11:22, Friday 01 November 2013 (8355)
BSC3 ISI locked, corner cube installed

This morning, I locked the BSC3 ISI and Greg went into the chamber and installed the corner cube. I'm not sure what state the ACB is normally in when the cube is attached, but it is in the lowered position right now, which made install of the cube precarious. Greg was able to do it, but it didn't look easy. Otherwise, we are ready for IAS to start working.

LHO VE
kyle.ryan@LIGO.ORG - posted 10:28, Friday 01 November 2013 (8354)
Vented sleeve surrounding GV6's gate annulus piping leak


			
			
H1 INS (INS, SEI)
jim.warner@LIGO.ORG - posted 09:51, Friday 01 November 2013 (8352)
HAM's 2 & 3 Locked

HAM's2 and 3 ISI's were locked this morning. Originally went out just for HAM2, but I saw that Apollo had just finished pulling the last door at HAM3, so I took advantage. I think immediate activities are planned only at HAM2, so if HAM3 needs to be released for some reason, let me know.

H1 SUS (SUS)
jeffrey.kissel@LIGO.ORG - posted 18:32, Thursday 31 October 2013 (8351)
ECR 1300578 Progress -- HLTS and HSTS Library Models Complete, Need Installation and New MEDM Screens
J. Kissel

Because the DAQ was needed this morning for measurements, we didn't resurrect the dead h1sus56 computer until the afternoon. That meant I didn't get nearly as far as I'd hoped before leaving. My apologies. The current status is reported below, and will most likely remain as such until I get back from vacation on Tuesday.
 
Status:
- Mods to the HSTS_MASTER and HLTS_MASTER library parts (and all the library parts they use) are complete -- the HSTS required a little extra thinking, unfortunately
- The MC_MASTER remains unchanged, didn't get to it
- The top-level HLTS models' (H1SUSPR3, H1SUSSR3) mods are complete, and they compile successfully
- The newly compiled front end code for H1SUSSR3 has been installed, and is now running; PR3's has not yet been installed
- Of the HSTS', only H1SUSMC1's top level model has been completed and successfully compiled. The remaining HSTS models must be reconnected as h1susmc1's has in order to compile. They are guaranteed to fail compiliation for the time being.
- None of the necessary MEDM screen modifications have been made for the HLTS or HSTS.

Because I do not commit to the repository until I have a complete package for Stuart, the outstanding svn status I reported yesterday remains.
H1 INS (INS, SEI)
jim.warner@LIGO.ORG - posted 18:02, Thursday 31 October 2013 (8350)
TF running on ETMX

Transfer functions running on ETMX ISI, starting now. Should end by 8 AM. Running on opsws6.

H1 CDS (SEI, SUS)
james.batch@LIGO.ORG - posted 16:36, Thursday 31 October 2013 (8349)
LVEA Test Stands Powered off
The LVEA test stands (h1susquadtst, h1susbstst, h1seitst) have been powered off, removed from the DAQ, and removed from the dolphin configuration.  All equipment has been left in place for future use.
H1 CDS
david.barker@LIGO.ORG - posted 14:41, Thursday 31 October 2013 - last comment - 10:12, Friday 01 November 2013(8342)
transition from matlab 2010a to 2012b, you may not be able to go back

I made PSL model changes this week to add channels to the science frame. Pre-empting next week's upgrade to matlab2012b, I modified all the mdl models used to build the code using 2012b (in some cases just adding an SVN $Id$ tag in order to make a change).

Today I tried to open the psl models using matlab2010a. I had no problems with h1psliss and h1pslfss, but h1pslpmc crashed 2010a. There are no problems opening this with 2012b. Presumably PMC uses some matlab parts with are not backwardly compatible with 2010a.

When I made the transition, the original 2010a versioned file was save by matlab with a 2010a prefix. We should always do this.

Comments related to this report
cyrus.reed@LIGO.ORG - 10:12, Friday 01 November 2013 (8353)

You have to use the 'Export Model to > Previous Version' if you want to save a model in the earlier format.  Incompatible blocks that postdate the export file format version are converted to empty masked subsystem blocks in the exported file:

http://www.mathworks.com/help/simulink/ug/saving-a-model.html#f2-86382

The default file format is set in the preferences, or via command line: