Displaying reports 81101-81120 of 87792.Go to page Start 4052 4053 4054 4055 4056 4057 4058 4059 4060 End
Reports until 15:34, Thursday 27 June 2013
H1 CDS
cyrus.reed@LIGO.ORG - posted 15:34, Thursday 27 June 2013 (6904)
Emergency switch reboot (sw-lvea-aux0)
I had to do an emergency reboot of sw-lvea-aux0 today at 14:51 local time, to correct some copy-paste induced errors in the config.  The reboot was (unfortunately) the quickest way to restore the working configuration.  It should be functioning normally now.
H1 ISC
alexan.staley@LIGO.ORG - posted 23:30, Wednesday 26 June 2013 (6900)
ALS corner noise - IR transmitted as sensor

(Chris, Kiwamu, Stefan)

We roughly calibrated the IR transmitted light (still ASC Quad sum, since Sheila wasn't quite able to finish due to a short earthquake).

Method:

- We sit on the side of the fringe (peak/2) of the IR cavity fringe, which has a pole frequency of 82Hz, i.e. power is proportional to P0/( 1+( f/82Hz )^2 ) .

- This gives a slope  of dP/df = Po/(2*82Hz), i.e. the DC calibration (with P0=250cts) is 0.656Hz/ct (at DC)

- The cavity pole is now complex (since the two freq-mod side bands see different transfer function), but we were too lazy to do this math right, and just stuck in a real zero at 82Hz to compensate the cavity pole. This is good within a factor of 2 above the cavity pole.

 

The attached plot shows

- Green: Transmitted IR at peak/2, calibrated in Hz/rtHz

- Dashed-Green: RMS of previous one.

- Blue: MC_F, calibrated in Hz. above the x-over (~100Hz) this measures the laser frequency drive

- Mustard: Ey PLL noise, calibrated in Hz (free running Laser noise)

- Gold: EY PDH control signal (actually wong - should be ~10 times higher, due to the changed PDH control scheme - see previous elog for correct calibration)

 

Conclusion: we supress real motion down to ~40Hz, above that we are imprinting ALS sensing noise (probably from the corner setup) onto the IR light. The obvious strategy to lower the 34Hz RMS noise is to lower the UGH (turn the AO path off) and add some significant boost filters at low frequency. Our initial attempt for doing this ran into DAC saturation issues on MC2.

Non-image files attached to this report
H1 AOS
stefan.ballmer@LIGO.ORG - posted 20:23, Wednesday 26 June 2013 (6899)
EY: calibrated noise and PDH additive offset bypassing the PLL
(Kiwamu, Alexa, Matt, Stefan, from yesterday)

As part of the ALS noise hunting, we revisited the PLL and PDH loops at EY.

- First we realigned the PDH diode that was intentionally misaligned the night before. We verified the the DC oscillations observed on that diode's read-back are not present in analog, so there must be some issue with the acquisition of that signal.
- Next, we looked at the PLL loop. With a UGF around maybe 20kHz it produced a lot of gain peaking around 30kHz. We turned the BOOST stage 1 on the PLL Sigg board off. That helped, but the loop was happiest at another 10dB lower gain.
- This suggested the idea of an "additive offset" like path, bypassing the PLL loop all together. We rigged this control scheme by using one additional BNC cable:
  - We moved the cable that runs to the VCO tune input from the PDH Sigg board fast output to the PDH Sigg board EXC B monitoring point (either 1 or 2 - they have opposite sign). We would like to use the slow path for this option, but it had additional undesired low-pass filtering.
  - We added a cable from the PDH Sigg board fast output to the PLL Sigg board EXC A input. This keeps a high-frequency roll-off as well as some PZT notches in the path.
  - The PDH Sigg board fast gain was lowered from 0dB to -22dB to set the AO gain. The PDH Sigg board input 1 gain was set to -4dB.
  - With this setting we got a nice, roughly 1/f total loop shape, and a UGF of 20kHz.


Our hope was that this configuration will change the noise seen at the end corner, but we had no luck - the corner noise was unchanged.

PS: Attached is a plot of the calibrated frequency noise in Hz/rtHz seen by 3 sensors:
 - Blue: PLL control signal: dominated by free-running laser noise
 - Purple: PDH control signal: above 2kHz this shows coherence with blue (not in figure), indication laser noise. But below 2kHz we seem to be limited by some other PLL sensing noise (electronics dark noise ?) Note that this noise was taken in the old control loop topology, because the control signal calibration was simpler.
 - Red: ALS in-loop common mode error signal from the corner beat node. Note that it is NOT coherent with any of the noise we see at the end.


PPS: We also noted that we are able to grab an arm lock with the PLL input disabled (i.e. without relying on the fiber for per-stabilization). However we would need some more low frequency gain to keep the lock in this configuration.

 
Non-image files attached to this report
H1 ISC
christopher.wipf@LIGO.ORG - posted 19:43, Wednesday 26 June 2013 (6898)
LSC, ISCEY model updates

h1lsc and h1iscey front ends were updated yesterday as follows.

LSC:

ISCEY:

Attachments: (1) ISCEY top level; (2) ALS subsystem showing state/control logic.

For both systems, safe.snap files have been updated and committed to SVN.

Closing WP 4005.

Images attached to this report
H1 COC
gerardo.moreno@LIGO.ORG - posted 17:46, Wednesday 26 June 2013 - last comment - 16:17, Thursday 27 June 2013(6895)
PUM-ETM04 Prism Update

(Betsy W, Gerardo M, Gerardo A. M)
Prism was removed today, finally. It took about 7 days of the common process of soaking the prism joint in acetone, then working on the joint by hand with a razor blade along with some acetone as a lubricant.
2 photos attached, one is where the prism used to be, second photo is the removed specimen.

Images attached to this report
Comments related to this report
betsy.weaver@LIGO.ORG - 12:19, Thursday 27 June 2013 (6902)

The prism will be reglued (into a new position that corrects for the ear placement error) during the early part of the week of July 8th.  The PUM will then be packed up and sent to LLO for use in their ETMx monolithic suspension.

norna.robertson@LIGO.ORG - 16:17, Thursday 27 June 2013 (6906)
This timing for regluing depends on our having resolved the likely cause of the PUM crack and how to avoid it happening again during future welds.
LHO VE
kyle.ryan@LIGO.ORG - posted 16:52, Wednesday 26 June 2013 (6897)
Helium removal
Turbo valved-in for 8 hrs -> End value 4.1 x 10-7 torr*L/sec
H1 SUS
mark.barton@LIGO.ORG - posted 16:43, Wednesday 26 June 2013 (6893)
SUS-AUX support in SITEMAP

I cleaned up and extended the rudimentary support for SUS AUX that Dave Barker recently added to the SITEMAP:

* I tweaked the screen linked from the AUXEY menu item, /opt/rtcds/userapps/trunk/sus/common/medm/SUS_AUX_EY_OVERVIEW.adl, and the args supplied to it, fixing errors and changing all the H2-specific stuff to be generic.

* I adapted SUS_AUX_EY_OVERVIEW.adl to create SUS_AUX_HAM2_OVERVIEW.adl, SUS_AUX_HAM34_OVERVIEW.adl, SUS_AUX_HAM56_OVERVIEW.adl and SUS_AUX_EX_OVERVIEW.adl.

* I changed the names of the existing  HAM2 and HAM34 buttons to AUXHAM2 and AUXHAM34 to match AUXEY and linked the HAM2 and HAM34 screens to them. However none of the X-arm section of the SITEMAP is populated as yet so I didn't attempt to link to the HAM56 or EX screens.

All the new stuff was committed to the userapps SVN.

LHO General
corey.gray@LIGO.ORG - posted 16:10, Wednesday 26 June 2013 (6888)
Ops Day Summary

BSC2 NE Vert HEPI Actuator back in RUN mode (Hugh)

Operate HAM3 East Door RGA (John)

More work on TMTS (Transmon Telescope SUS) model by Mark B starts around 10:45am (requiring DAQ restart by Dave afterward)

PCal Work starting in H2 PSL Room (Pablo, Colin, Craig, Michael R.)

CDS Alarm:  several h1iscey IOP State Word alarms several times a day

Jim B shutting down framewriter0 (10:35am)

changing compressor at MX; gave instrument air alarm, and also Vacuum alarm for CP6 since we use Instrument Air for the valve. (Ski)

Crew here for taking water samples at 11:40am

H1 SEI
jim.warner@LIGO.ORG - posted 16:01, Wednesday 26 June 2013 (6896)
eLIGO HAM6 ISI disassembly started today

MitchR, JimW

We started taking the eLIGO HAM6 ISI apart today, so that we can replace its sensors and cabling with aLIGO parts. Walls covering GS-13's were removed, then we started on the seismometers themselves, with 4 out of 6 removed. Horizontal CPS's are mostly out, we just didn't have cutters for some zipties. Tomorrow, we will finish up the pods, and strip the remaining cabling. We did find one bolt that galled as soon as we put a wrench on it (maybe before?), which ended up breaking instead of cooperating, and one bolt that threatened to gall, but it behaved after plying it with alcohol.

H1 ISC
christopher.wipf@LIGO.ORG - posted 15:45, Wednesday 26 June 2013 (6894)
new library parts for ALS

The following new RCG library parts have been added to the repository for use with the ISCEY/ALS model.

Images attached to this report
LHO VE
kyle.ryan@LIGO.ORG - posted 13:36, Wednesday 26 June 2013 (6892)
X-mid instrument air alarm
Found instrument air was valved-out in the chiller yard -> something Ski was doing earlier -> Opened valve -OK
H1 SUS
mark.barton@LIGO.ORG - posted 12:26, Wednesday 26 June 2013 - last comment - 10:34, Thursday 27 June 2013(6890)
TMTS channels added to DAQ

Per a request of Jeff K, I made an additional update to the TMTS_MASTER.mdl, to add DAQ requests for the 6 ...M1_DAMP_*_IN2 channels. I then rebuilt and restarted h1sustmsy.mdl.

In the process I noticed that there were error messages being generated from the following lines in the safe.snap (these may have been there yesterday, see alog 6883, but I don't recall), so I manually edited the file and removed the second half of each line.

H1:SUS-TMSY_M1_DAMP_P_STATE_GOOD 1 H1:SUS-TMSY_M1_DAMP_P_STATE_GOOD 0
H1:SUS-TMSY_M1_DAMP_R_STATE_GOOD 1 H1:SUS-TMSY_M1_DAMP_R_STATE_GOOD 0
H1:SUS-TMSY_M1_DAMP_T_STATE_GOOD 1 H1:SUS-TMSY_M1_DAMP_T_STATE_GOOD 0
H1:SUS-TMSY_M1_DAMP_V_STATE_GOOD 1 H1:SUS-TMSY_M1_DAMP_V_STATE_GOOD 0
H1:SUS-TMSY_M1_DAMP_Y_STATE_GOOD 1 H1:SUS-TMSY_M1_DAMP_Y_STATE_GOOD 0

Chris Wipf then reported that sometime in the last few days, the setting for the alignment offset gains in the safe.snap had been reset to 1 (whereas they are supposed to be magic numbers that convert mrad of desired offset to counts of actuation). So I transplanted the following lines from an hourly backup from 6/20/13:

H1:SUS-TMSY_M1_OPTICALIGN_P_OFFSET 1 -8.950000000000000e+01
H1:SUS-TMSY_M1_OPTICALIGN_P_GAIN 1 1.583586000000000e+02
H1:SUS-TMSY_M1_OPTICALIGN_Y_OFFSET 1 1.899000000000000e+02
H1:SUS-TMSY_M1_OPTICALIGN_Y_GAIN 1 5.171050000000000e+01

The updated master model and safe.snap have been committed.

Comments related to this report
arnaud.pele@LIGO.ORG - 10:34, Thursday 27 June 2013 (6901)

This first error probably happened after the snapshot update I made for the "STATE_GOOD" channels of every suspension with a generic script (cf aLog 6813) and the second  because I didn't update the safe snapshot after applying the changes to the TMTS alignment offset gains (cf aLog 6749)

H1 ISC
lisa.barsotti@LIGO.ORG - posted 11:32, Wednesday 26 June 2013 (6891)
Summary status of EX TRANSMON ISC table
The assembly of the TMS ISC table is essentially done.
As far as I know, the only missing things to be installed are:

- everything related with cabling - pico cables, cable brackets, cable posts and cable ties
- one leg of the high beam dump 
- the optic (HR532HR1064, E1000425) for the bottom mirror of the periscope is ready to be installed, it is packed and labeled in one of the plastic bins under the ISC optics table at EX. 
- lens tags for the 1" lenses of the green sled (f = -56mm, I gave them to Corey)

Yesterday we finished doing the "coarse" alignment of the 532 nm and 1064 nm paths (a picture of the set-up will follow).
We also tested the QPDs.
To align the path from the beam diverter to the high power beam dump we used the green laser beam at full power.
The "fine" alignment will be done once the ISC table is mated to the transmon telescope.
LHO VE
john.worden@LIGO.ORG - posted 17:40, Tuesday 25 June 2013 (6887)
Helium pumping

Entry by Kyle,

Start  4.5 x 10-7 torr*L/sec

End 3.8 x 10-7 torr*L/sec

H1 IOO
daniel.sigg@LIGO.ORG - posted 16:50, Tuesday 25 June 2013 (6886)
PSL Frequency readback
(Dick, Daniel)
The readback of the  IMC/PSL VCO was flaky. Today, we concluded that the 3rd and 4th channel on the timing comparator/frequency counter do not work very well above 40 MHz. We put the PSL on the 5th channel and it now is reliable. We were also missing about 20 dB of signal. This turned out to be the splitter mounted to the patch panel in the LVEA which was operated in the wrong direction. Fixing this gave us a signal of about 3 Vpp.

A new medm screen with name ALS_CUST_FREQUENCIES.adl has been created which list all the VCO frequencies as well as linear combinations describing the various beat notes.
LHO General
corey.gray@LIGO.ORG - posted 16:16, Tuesday 25 June 2013 (6875)
Ops DAY Summary

Activites From Today

Aaron/Dominick running accelerometer cabling from H1 Elec Room -> H1 PSL Room

9:00 Hugh/Greg replacing BSC2 NE HEPI Vert Actuator Valve (will be invasive)

~11:30 Mark B will do model/channel work on EY TMS (this later required a DAQ restart by Barker)

Rogers Contractor here for Mechanical Room work (for Kyle)

Rodruck replacing Dust Monitor in Diode Room

Jim/Cyrus taking down FrameWriter0 (9:36am)

Robert with SURF student at EY

HIFO Investigations 1:20pm (Dick)

Chris W worked on lsc & isc models in the afternoon

h2 isi storage dewar filling (Greg)

Sheila is working at EY in the afternoon

Maintenance: 

H1 SUS
betsy.weaver@LIGO.ORG - posted 10:02, Sunday 23 June 2013 - last comment - 12:56, Thursday 27 June 2013(6858)
Violin mode measurements of ETMx monolithic silica fibers

Giles report from yesterday's work:

(Travis, Mark, Jason, Doug, Giles)

 

After leaving the PUM hanging overnight there was no further development of the crack. We then proceeded to re-lock the PUM and hang the ETM to perform modal measurements. Using the autocollimator we measured the longitudinal, pitch and yaw modes. We then setup and optical lever to measure the transverse, bounce and roll modes. Finally we measured the 4 fundamental violin modes. The modal data gathered was:         

 

Longitudinal    0.656 Hz

Pitch  1.09 Hz

Yaw  1.09 Hz

Transverse 0.656 Hz

Bounce 6.75 Hz (this will be sqrt(2) higher when the PUM is free)

Roll 9.6 Hz (this will be sqrt(2) higher when the PUM is free)

 

FR  505 Hz

FL  506.5 Hz

BR  506.5 Hz

BL  505 Hz

 

We finally installed the fibre guards and covered the entire lower stage.

Comments related to this report
betsy.weaver@LIGO.ORG - 10:25, Wednesday 26 June 2013 (6889)

Serial Numbers of fibers on the suspension now:

 

FL S1300183

FR S1300191

BL S1300190

BR S1300193

 

S1300186 was trashed during the welding as it was installed and then cut out as noted above.

travis.sadecki@LIGO.ORG - 12:56, Thursday 27 June 2013 (6903)

Correction: BR is actually S1300173.

Displaying reports 81101-81120 of 87792.Go to page Start 4052 4053 4054 4055 4056 4057 4058 4059 4060 End