Displaying reports 8161-8180 of 87808.Go to page Start 405 406 407 408 409 410 411 412 413 End
Reports until 22:07, Friday 27 December 2024
H1 General
oli.patane@LIGO.ORG - posted 22:07, Friday 27 December 2024 (82019)
Ops Eve Shift End

TITLE: 12/28 Eve Shift: 0030-0600 UTC (1630-2200 PST), all times posted in UTC
STATE of H1: Observing at 161Mpc
INCOMING OPERATOR: Ryan C
SHIFT SUMMARY: Currently Observing and have been Locked for 4 hours. Relocking went well, although we were in OMC_WHITENING for a bit damping violins. I did not have to touch anything besides choosing HIGH_ARM_POWER on the LOCKLOSS_SHUTTER_CHECK guardian (I think that was a side effect of me MANUALing it before correctly INITing it into LOW_ARM_POWER earlier in the locking process - I had reassigned the node manager back to ISC_LOCK but I think it must've already passed the part where ISC_LOCK told it to go to high power) and the evening has been quiet.
LOG:

23:16 Lockloss while sitting in LOWNOISE_ASC, going to sit in IDLE

00:19 Started relocking

02:00 NLN

02:01 Observing                                                                                                                                                                                                                               

Start Time System Name Location Lazer_Haz Task Time End
00:00 PCAL Dripta PCAL Lab y(local) PCAL work 00:27
23:40 EE Fil CER n Reconnecting HAM6 HV to BSC3 00:15
H1 General (CDS, SYS, VE)
oli.patane@LIGO.ORG - posted 17:00, Friday 27 December 2024 - last comment - 18:19, Friday 27 December 2024(82016)
Ops Eve Shift Start

TITLE: 12/27 Eve Shift: 0030-0600 UTC (1630-2200 PST), all times posted in UTC
STATE of H1: Corrective Maintenance
OUTGOING OPERATOR: Corey
CURRENT ENVIRONMENT:
    SEI_ENV state: USEISM
    Wind: 8mph Gusts, 5mph 3min avg
    Primary useism: 0.08 μm/s
    Secondary useism: 0.78 μm/s
QUICK SUMMARY:

Currently starting relocking and at ENGAGE_ASC_FOR_FULL_IFOjust lost lock from ENGAGE_ASC_FOR_FULL_IFO. Fil just finished the work reconnecting the ITM ESDs and connected the HAM6 high voltage relays to the BSC3 interlocks(something like that - see attached). After he did this we tested out the port protection but it failed due to the fast shutter not being open. It seems like the fast shutter usually reopens when we are going through PRMI/MICH states, so that might have been why it was still closed from our last lockloss, but it doesn't completely make sense because earlier before Corey ran the test, the shutter had opened on its own while we sat in IDLE. I opened the shutter medm and manually opened the shutter and reran the test. It failed again and said it was due to the fast shutter not being able to reopen even though it had correctly closed and reopened it. I toggled the shutter closed and back open, and this time the test ran and came back with OK, so it seems like we are good to go to high power. Jenne called and had me check that we had ESD outputs on ITMX, which we did so it looks like everything is good to go.  When at CHECK_AS_SHUTTERS we did have the LOCKLOSS_SHUTTTER_CHECK alert that we needed to manually check the shutter, so I ran the test script on the AS port protection screen again just to make sure and then INIT'ed that guardian.

As as of Fil completing this work, THE ENTIRE CORNER STATION HIGH VOLTAGE INTERLOCK SYSTEM(except SQZ) IS CONNECTED TO BSC3. tagging VAC, SYS

Also, I am unable to view the guardian logs - when I open them they say 'Leap second data is expired' and then close Tagging CDS

Images attached to this report
Comments related to this report
oli.patane@LIGO.ORG - 18:03, Friday 27 December 2024 (82017)

Back to Observing as of 12/28 02:00 UTC!!

michael.landry@LIGO.ORG - 18:19, Friday 27 December 2024 (82018)

Great recovery, congratulations all!!

LHO General
corey.gray@LIGO.ORG - posted 16:46, Friday 27 December 2024 (82012)
Fri Ops DAY Shift Summary

TITLE: 12/27 Day Shift: 1530-0030 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Corrective Maintenance
INCOMING OPERATOR: Oli
SHIFT SUMMARY:

Today started off with addressing the HAM6 interlock which was no longer functioning due to missing the vacuum gauge it needs (i.e. the failed PT110 on HAM6 from last night!). 

Fil came in to take the BSC3 vacuum gauge to take the FAILED HAM6 vacuum gauge's place for the HAM6 interlock.  This would pull the BSC3 gauge from the interlock it was used for:  ITM ESDs---it was thought the ITM ESDs were NOT used.   Returned to locking, but then it was later brought up that the ITM ESD interlock is indeed needed for TRANSITION FROM ETMX.  

So we were on hold again.  

Ultimately it was decided to use the BSC3 vacuum gauge for BOTH the (1) HAM6 & (2) BSC3's ITMx ESD interlocks.  Fil came in (2nd time driving out to the site today!) to make this change in the afternoon.  

The hope is we are now back to a the state before the HAM6 gauge/interlock crashed last night, and Oli can return with locking.  Winds are lower than yesterday, BUT microseism is still high.  

LOG:

 

H1 AOS
jenne.driggers@LIGO.ORG - posted 14:25, Friday 27 December 2024 (82015)
Using ETMY ESD for lock acquisition, rather than ITMs

[Corey, Sheila, Dave, Jenne]

With the ITM ESD high voltage interlock being used instead for HAM6 high voltage things, we cannot use the ITMs for the ESD transition at the end of the locking sequence.  We are trying to instead use ETMY. 

Non-image files attached to this report
LHO VE
david.barker@LIGO.ORG - posted 12:13, Friday 27 December 2024 (82014)
Fri CP1 Fill

Fri Dec 27 10:16:08 2024 INFO: Fill completed in 16min 4secs

 

Images attached to this report
LHO VE (CDS, ISC, OpsInfo, SYS, VE)
corey.gray@LIGO.ORG - posted 10:40, Friday 27 December 2024 - last comment - 10:04, Wednesday 02 April 2025(82011)
HAM6 Interlock Status After HAM6 Vacuum Gauge Failure Last Night

(Dave Barker, Fil Clara, Jenne Driggers, Corey Gray, Gerardo Moreno, plus those who signed work permit and whom I phoned last night)

Last Night Recap:
Last night at 959pmPT, there was an audible alarm for the HAM6 vacuum gauge (PT110).  Gerardo went out to check to see if it was dead.  He phoned Fil and they did a power cycle of the gauge to see if this would improve the situation, but it did not.  After this, H1 was taken to IDLE for the night (OWL shift cancelled).  (Should have taken Observatory Mode to CORRECTIVE MAINTENANCE at this point, but only remembered to do this this morning.)

Work Permit 12260 generated.  Fil arrived on-site around 9amPT (17utc).

This Morning's Summary of Fil's Work:

The HAM6 Interlock (for operations of the Fast Shutter + PZT) is now Using the BSC3 Interlock (or VAC gauge from BSC3 since it was decided to BYPASS the HAM6 VAC gauge which failed last night [alog 82005]).  This means that the BSC3 Interlock is no longer being used for the ITM ESDs (which sounds like it's fine because Jenne/Fil said we don't use the ESDs for the ITMs).

Fil noted that he confirmed that the Fast Shutter Chassis in the LVEA is OPERATIONAL.  Fil then left the site after giving me this summary.

As far as a test of this new HAM6 Interlock configuration, I intentionally ran a test of the AS Port Protection system (sitemap/SYS/ AS Port Protection....this was my first time doing this).  After clicking the RUN (test) button, after a few seconds received an "OK" for the (1) Test & (2) Fault.  After this test and the signed-off Work Permit, we are OK to GO for High Power locking.

Currently running an Initial Alignment (note:  ISC_LOCK initially went into ERROR [red box] when I selected Initial Alignment (screenshot of error message attached).  LOAD-ing ISC_LOCK (suggested in the Log) cleared this up.

ALSO: 

Images attached to this report
Comments related to this report
jenne.driggers@LIGO.ORG - 12:09, Friday 27 December 2024 (82013)

Sheila reminded me that we do use ITMs for acquisition, so she's making modifications to the guardian so that we'll use ETMY instead of the ITMs for acquisition.

corey.gray@LIGO.ORG - 10:40, Saturday 28 December 2024 (82031)FRS

FRS:  https://services1.ligo-la.caltech.edu/FRS/show_bug.cgi?id=32955

filiberto.clara@LIGO.ORG - 10:04, Wednesday 02 April 2025 (83700)

HAM6 interlock has been restored. HAM6 gauge is scheduled to be replaced during upcoming vent. See alog 83695.

LHO General
corey.gray@LIGO.ORG - posted 09:49, Friday 27 December 2024 (82010)
Fri Ops Day Transition

TITLE: 12/27 Day Shift: 1530-0030 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Aligning
OUTGOING OPERATOR: Ryan C
CURRENT ENVIRONMENT:
    SEI_ENV state: USEISM
    Wind: 10mph Gusts, 8mph 3min avg
    Primary useism: 0.07 μm/s
    Secondary useism: 0.69 μm/s
QUICK SUMMARY:

Filibert has been on-site this morning to work on bypassing the failed vacuum gauge at HAM6 to get the Fast Shutter interlock operational again (just received a summary of his work).

Next step is to wait for the Work Permit to get signed for high power operations and then return to locking.

Microseism is still high but only light winds (but basically this is the same state we were in last night where H1 had troubles getting past TRANSITION FROM ETMX.  SEI CONFIG is in the USEISM state.

LHO VE (VE)
corey.gray@LIGO.ORG - posted 23:18, Thursday 26 December 2024 (82008)
OWL Shift Cancelled Due to HAM6 Vacuum Gauge Failure Which Is Also Used for Fast Shutter Interlock

Since the HAM6 gauge which failed at 10pm local time is used as part of the interlock system for the Fast Shutter, Jenne made the call to have the H1 down for the night (Owl Shift Canceled)

Tomorrow we will need to figure out the plan forward for H1 operations.  Whatever the fix will require a Work Permit and will need to figure out availability for who can do this work.  

LHO General (CDS)
corey.gray@LIGO.ORG - posted 23:10, Thursday 26 December 2024 (81999)
Thurs EVE Ops Summary

TITLE: 12/27 Eve Shift: 0030-0600 UTC (1630-2200 PST), all times posted in UTC
STATE of H1: Wind
INCOMING OPERATOR: Ryan C
SHIFT SUMMARY:

Bit of a frustrating shift with H1 losing lock most of the time at the same point late in the ISC_LOCKing scheme (alog 82000).  Plus dealing with high seismic motion (microseism is still around 1um/sec).  No alignments were run or needed this shift.  With locking, made it fairly repeatedly all the way up to around TRANSITION_FROM_ETMX / LOWNOISE_ESD_ETMX for majority of shift's locklosses.  For relocking, DRMI generally looks horrible, but PRMI does the trick for continuing on beyond DRMI---hence no Initial Alignments have been run this evening.

And shift ends with a M5.9 mid-Atlantic earthquake rolling through.
LOG:

H1 CDS
david.barker@LIGO.ORG - posted 22:23, Thursday 26 December 2024 - last comment - 08:09, Friday 27 December 2024(82005)
VACSTAT reports BSC3 and HAM6 issues

At 21:58 VACSTAT issued a BSC3 alert, which looks like it could be a sensor spike. 1 minute later PT110 (HAM6) sensor went offline to flat 0.0Torr.

Images attached to this report
Comments related to this report
david.barker@LIGO.ORG - 22:37, Thursday 26 December 2024 (82006)

VACSTAT restarted and PT110B removed from the gauge list.

Images attached to this comment
david.barker@LIGO.ORG - 22:59, Thursday 26 December 2024 (82007)

Pressure trend for BSC3 (PT132) and HAM6 (PT110) trends. BSC glitch 21:56:48, HAM6 dropout 21:59:24

Images attached to this comment
david.barker@LIGO.ORG - 08:09, Friday 27 December 2024 (82009)

BSC3 sensor glitch at 06:59:43, could be related to HAM6 issue, these are the same type of gauge. I restarted VACSTAT at 08:05 to clear this, it is again running with HAM6 PT110 DISABLED.

Images attached to this comment
H1 CDS (CDS, DetChar)
corey.gray@LIGO.ORG - posted 18:55, Thursday 26 December 2024 (82001)
Services Down: H1 LOCKLOSSES & H1 Summary Pages Are Not Viewable

Can not look at the:

I have been able to look at these pages for L1 with no problem, but for the above, they just time out after a few minutes of trying to load their webpages.

Noticing that all of these are ldas-jobs.ligo-wa, I looked for that and found something via monitor.ligo.org, which led to the CUBE visualization and then clicked on Problems, and under here are several Host & Service problems.  For "ldas-jobs-lho" it has had issues for the last 19hrs (or since midnight last night.

Images attached to this report
H1 SUS (ISC, SUS)
corey.gray@LIGO.ORG - posted 18:10, Thursday 26 December 2024 - last comment - 21:38, Thursday 26 December 2024(82000)
(2) Consecutive Locklosses At LOWNOISE_ESD_ETMX

As the winds have finally become manageable, H1 has 2-locklosses in a row at beginning (within 2secs) of starting the LOWNOISE_ESD_ETMX state.  (this is after h1 being down for most of the day due to winds [which are now lower], AND with high microseism which still is high)  Alignment looks good after the afternoon alignment run by Tony toward the end of his shift.  DRMI has looked a bit ugly, but PRMI has repeatedly locked (albeit ugly-looking at first) and had ISC_LOCK with smooth sailing....until....LOWNOISE_ESD_ETMX.  Will pause at TRANSITION_FROM_ETMX for this next lock attempt.

Comments related to this report
corey.gray@LIGO.ORG - 19:16, Thursday 26 December 2024 (82002)ISC, SUS

For Attempt #3, paused at TRANSITION_FROM_ETMX (for about 1min after that state was completed), and then proceeded on to LOWNOISE_ESD_ETMX and had then made it to NLN.

Wondering if we need to revisit the ETMx transition stuff Elenna alog-ed about in Nov -OR- the issues around these states were just a coincidence and more due to our noisy ground motion from microseism.

corey.gray@LIGO.ORG - 20:27, Thursday 26 December 2024 (82003)

Attempt #3 was only locked for 14min.

1st attempt after the above lockloss, lost lock while going through the TRANSITION_FROM_ETMX state.  (Microseism still high [just under 1um/sec] and winds are fairly calm).

Displaying reports 8161-8180 of 87808.Go to page Start 405 406 407 408 409 410 411 412 413 End