Displaying reports 82941-82960 of 88359.Go to page Start 4144 4145 4146 4147 4148 4149 4150 4151 4152 End
Reports until 16:43, Tuesday 26 February 2013
LHO VE
john.worden@LIGO.ORG - posted 16:43, Tuesday 26 February 2013 (5589)
Hard-closed GV7

~1630 hrs. local

John W.  requested that I increase the air pressure applied to the top of GV7's piston to ~20 psi so that we could be assured that the "Soft-closed" GV7 gate was in full contact with its O-rings.  If not in full contact, IP6 might be pumping hydrogen from the X-arm which would confuse the pressure comparison between the two BTs.  -> As found,  the piston close pressure was ~5 psi -> I increased this to 20 psi -> GV7's gate cammed fully closed a few minutes later

GV7 is now "Hard-closed"

LHO General
patrick.thomas@LIGO.ORG - posted 16:22, Tuesday 26 February 2013 (5588)
restarted dust monitors and weather stations
I restarted and burtrestored the IOCs for the dust monitors and weather stations at both end stations to recover from a loss of connection.
LHO VE
kyle.ryan@LIGO.ORG - posted 16:19, Tuesday 26 February 2013 (5587)
Pumping at X-end shut down unexpectedly
The turbo pump system at X-end shut down for no obvious reason around midday(?) today -> I used this "down time" do some routine maintenance on the QDP80 backing pump (grease rotor bearings, change gear oil - 400cc Krytox - and top off heat exchanger coolant but these all looked normal) -> Restarted QDP80 and MTP -> I'll leave these running but valved out from the X-end VE for overnight 

Operators Note:  
X-end under vacuum but unpumped overnight, i.e., X-end pressure will be increasing and PT510B value may change from "green" to "yellow" if left this way indefinitely - no action is required.  

H2 SEI
hugh.radkins@LIGO.ORG - posted 16:18, Tuesday 26 February 2013 (5586)
WBSC8 HEPI/iLIGO CAS Swap Update
Got the first Corner(NE) HEPI Housing down from BSC8.  The iLIGO CAS Support Stack is part way in and will continue tomorrow.
H1 AOS
jodi.fauver@LIGO.ORG - posted 15:44, Tuesday 26 February 2013 (5585)
BSC10 ICC
Vacuum-wipe down-vacuum complete. Inspection underway: it should be completed by the end of shift. FTIRs and installation of permanent BSC flooring tomorrow.
Logistical problems trying to get a cleanroom from the cleaning area into the VEA to cover the dome. Randy is taking a look at the situation. 
We started hauling ICC/staging gear back to the corner. 
H1 SUS
mark.barton@LIGO.ORG - posted 15:30, Tuesday 26 February 2013 (5584)
SUS model updates
Mark B. and Arnaud P.

Yesterday and today we made a bunch of minor model changes:

We added PCIE outputs H1:SUS-MC1_2_ISI_OFFLOAD_{X/Y/RZ/Z/RX/RY} to MC1, and similarly for MC2, MC3, PR3 (PR2 and PRM already had them).

We reconnected the watchdogs on PRM and PR3, now that they're in the chamber on the ISI.

We deleted "_2_SUS" from the names of PCIE inputs H1:ISI-ETMY_2_SUS_GS13_{X/Y/RZ/Z/RX/RY} in the TMSY model to bring them into line with what the ISI was sending. (The ETMy and ITMy models were changed to this convention earlier.) Similarly we also deleted "_ISI2SUS" from EPICS outputs (H1:SUS-)TMSY_ISI2SUS_GS13_{X/Y/RZ/Z/RX/RY} .

All of these mods were committed to the userapps SVN and were compiled and installed under rtcds 2.6.2 as part of today's upgrade.

We noted that h1susauxb123.mdl  exists in the SVN but is not under version control and resolved to find out its status and get it working and/or commit it.
H1 AOS
arnaud.pele@LIGO.ORG - posted 15:15, Tuesday 26 February 2013 (5583)
BeamSplitter Phase 2b Power Spectra

BS BSTS BSFM

Attached are plots of phase 2b power spectra for the beamsplitter installed in the test stand.
allbsfms_2013-02-25_H1_BS_Phase2b_ALL_Spectra_{Doff/Don}.pdf  file shows comparison between LLO BS (Phase 3a Oct 2012) and LHO BSTST(Phase 2b Feb 2013).
2013-02-25_1000_H1SUSBSTST_M{1/2}_ALL_Spectra.pdf show comparison between damping on and damping off.

**Resonnances from LHO are consistent with those from LLO.

**Damping is doing his job correctly

The plots all look good, nothing to notice in particular.

Transfer functions will be running overnight to finalize Phase 2b.

PS: The script *plotallbsfm_spectra.m* has been modified, after noticing a small mistake. The pdf files comparing data from different sites were created under the name allhstss_ instead of allbsfms_.

Non-image files attached to this report
H1 INS
jodi.fauver@LIGO.ORG - posted 14:34, Tuesday 26 February 2013 (5582)
BSC2 Install Prep Checklist
Work Platform in place-Done
Cleanroom in place-Done
E-module in place (Beer garden)-Done
Add hand-rail to e-module
Build custom bridge between work platform and e-module
Move garbing/staging cleanroom from spool area to top of e-module
Move cleanroom from HAM aux optics table to BSC2-HAM3 for garbing/staging
Work on cleanroom curtains-Started 26 Feb 2013
Check cleanroom function
Clean chamber and cleanrooms
Stage garbing/staging cleanrooms
Baffle assembly (Clean test stand-solid stack to test stand ~28 Feb-Shelving units moved out-work tables moved in-clean cleanroom and contents prior to assembly start)

LHO General
patrick.thomas@LIGO.ORG - posted 09:33, Tuesday 26 February 2013 (5581)
LVEA dust monitor 15
I turned it back on and turned off the audible alarm, as it is no longer in a clean room.
H1 SEI
hugh.radkins@LIGO.ORG - posted 08:11, Tuesday 26 February 2013 (5579)
LVEA HEPI Leak Check Update
This morning I find no pressure drop from yesterday morning so I opened the second side of BSC1 and BSC2 to the pressure gauge.  Maybe we'll have some info later today.
H1 PSL
michael.rodruck@LIGO.ORG - posted 17:36, Monday 25 February 2013 (5578)
PSL shutdown

The laser tripped last night due to low flow from the diode chiller. This morning the chiller room was leaking water and I found a broken fitting inside the water tank, where water had been leaking out. I pulled the broken piece out and will install a new one hopefully tomorrow.

Images attached to this report
LHO General
justin.bergman@LIGO.ORG - posted 15:57, Monday 25 February 2013 (5576)
Ops Summary
30mph winds all day

0800 - PSL offline; issues with diode chiller flow interlock. Michael R investigating; may need to order replacement fitting before PSL can be restarted.
0810 - Filiberto running cables in H1 electronics room and along HAM2/3.
0800-1600 Apollo crew at EY (chamber cleaning).
0930 - Corey working in LVEA eastbay.
0930 - Contractor onsite to remove old shipping pallets and crates.
1000 - Hugh in LVEA looking for HEPI issues/leaks.
1050 - Betsy working in HAM2.
1145 - Catering service onsite.
1345-1600 - Michael L and visiting scientists touring Staging, VPW and EY buildings.
1400 - Apollo installing cleanroom and work platforms over BSC2.
1547 - Mark B and Arnaud restarting multiple SUS user models after creating changes in IPC connections. No conflicts with other users expected.
LHO General
bubba.gateley@LIGO.ORG - posted 15:40, Monday 25 February 2013 (5577)
Apollo crew
Work platform assembled around BSC 2 and clean room in position over both. It is starting to look like the most likely position for the E - module is going to be in the beer garden. ICC continuing with first vacuum complete and 25% of wipe down. Generally 2-3 wipes are sufficient, which is better than I had expected.
H1 SUS
betsy.weaver@LIGO.ORG - posted 14:00, Monday 25 February 2013 - last comment - 08:50, Tuesday 26 February 2013(5575)
PR3 and PRM internal cable routing - HAM2

This morning, Fil finished running the external PR3 and PRM cables from the chamber feed thru (port D3) to the R1 rack.  Travis and I then connected the internal quadrapus cables from the PR3 and PRM to the D1000225 SRS cables that run down the ISI to the inside of the feedthru port.  The signals all seemed to come out in the appropriate places on medm so so far, so good.  We laced and stowed the cables for PR3 and then suspended the mass to verify the health of it's signals.  The M2 and M3 stage OSEMs were not perfectly well aligned, so the chamberside table is not as well leveled as the ISI, causing the suspension to hang differently in the cage now.  We tweeked a few top BOSEMs such that we can take TFs in prep for IAS alignment in a few weeks.  (The M2 and M3 stage OSEMs don't get aligned until after that alignemt).

In order to work on PR3 I had to stand in the beam tub on the HAM3 side of the HAM2 chamber.

 

While there, I also:

Picked up the older witness plate that was in the beam tube near HAM2.

Moved the newly placed witness plate (laid a few days ago) into a metal holder since it was vulnerable to breakage from standing near it.

Relaced the 4 SRS cables for CB1 and CB2 (PR3 connections) up the ISI, taking care to not ground between the ISI stages.  I did not have nearly enough slack to place the CB brackets in their appropriate spots on the table so I needed to pull from underneath the ISI and reclamp down the slack.  The cables I moved were laced up the NE corner of the HAM2 ISI.  SEI will make sure the lacing is appropriate when they test later in the month.

Added metal face shields to the PR3, MC1, MC3 - HR side of the suspensions - all are freely suspended though.

Comments related to this report
travis.sadecki@LIGO.ORG - 08:50, Tuesday 26 February 2013 (5580)

PRM has been cabled and top stage BOSEMs tuned.  It has been handed over to the testers for evaluation prior to IAS alignment.

X1 DTS
james.batch@LIGO.ORG - posted 11:43, Monday 25 February 2013 (5574)
Login computer changed for ssh access
The login server for ssh access to the DTS has been changed from x1login to x1dtslogin.  The x1dtslogin uses ligo.org authentication of users.  To access the DTS, users still need an account to be created by the local system administrator.

 
H1 DAQ
james.batch@LIGO.ORG - posted 11:38, Monday 25 February 2013 (5573)
Default NDS changed for h1
The default NDS for the control room computers has been changed from h1nds0 to h1nds1.  This takes effect with any new shell opened since 11:15 PST today.
H1 SEI
hugh.radkins@LIGO.ORG - posted 11:24, Monday 25 February 2013 (5572)
LHO LVEA HEPI Piping Valves Closed for leak checks
Lost about a PSI over the weekend and have been unable to find any leaks since Tuesday.  I have again shut all the valves I can, except those leading to BSC3, to help locate the problem area.
H1 CDS
david.barker@LIGO.ORG - posted 16:57, Saturday 23 February 2013 - last comment - 17:01, Saturday 23 February 2013(5570)
H1 DAQ upgrade

WP 3727, Alex, Dave, Jim

at 10:14 we shut down h1dc0 and replaced it with the new h1dc1. Jim activated a second 10GBE port on the H1 FE-DAQ switch and ran a second 10G FMM line to the DAQ rack. The new h1dc1 has three 10GBE pcie cards (compared with only two in h1dc0). The extra card allows the front ends to split their DAQ data over the two cards. Since each card has 16 MX end  points, and LHO will have a total of 31 front ends, this means that we can ensure that no two front ends share an end point and interfer with each other's DAQ data on reboot.

The 10GBE PCIe card arrangement as seen from the rear of h1dc1 is

top IN1 FMM-013-0001
mid OUT FMM-007-0006
lower IN2 FMM-013-0002

The pci bus mapping put the output card (connected to the Fujitsu switch) between the input cards.

The MX startup script for the front ends was modified such that the FE sent data to card IN1 or IN2 depending upon their location in the rtsystab file. We restarted all the front ends MX Streams (did not require any model restarts) and all DAQ data was back by 11:34

To test the new system we power cycled various non-dolphin and non critical front ends: h1pemmx, h1susauxb6 and h1susauxb123. During each reboot no DAQ data on any other system went bad.

Alex then upgraded the h1fw1/h1nds1 system and installed the following

Tests between the unmodified h1fw0 and the new h1fw1 systems show significant speed up in trend data retrieval. Speed up in minute trend writing quickly dissipated.

Comments related to this report
david.barker@LIGO.ORG - 17:01, Saturday 23 February 2013 (5571)

The new h1dc1 machine initially only had 12GB of RAM compared with h1dc0's 24GB. Not wanting to touch h1dc0 since that is our fall back machine if h1dc1 has issues, we removed 3*8GB DIMMs from h0broadcast0 and reduced its data cache so it could work with 12GB (6*2GB) RAM. We were then able to make h1dc1 a 24GB machine. We have asked John Z to check that the broadcaster is still functioning ok with reduced memory.

Displaying reports 82941-82960 of 88359.Go to page Start 4144 4145 4146 4147 4148 4149 4150 4151 4152 End