camilla.compton@LIGO.ORG - posted 10:43, Monday 10 March 2025 - last comment - 12:07, Monday 10 March 2025(83267)
Changes to FC Beamspot control ASC: now uses FC2 dither

Sheila, Matt, Mayank, Camilla

Today we changed the nominal FC beamspot control:

Sheila put the OSC amplitudes back to 10 and steps each AL2 gain to check its in I only (need to change PIT2 by 90deg), then adjusted A2Ls to get I close to zero. YAW1 has more noise than others.

Turned off the INJ_ANG ASC (feeds back to ZM3 as "FC beamspot control") and then steps ZM2/3/ P/Y offsets. After we worked out the matrix element, we tried to close each loop: turned off input, clear history, turn back on input, turn on gain. Closed each one and and did the next. Closed INJ_ANG for ZM3 in PIT and YAW.

ZM2 had a large response in PIT2 and not a noticeable response in PIT1. If we move ZM1, we see it in both PIT1 and PIT2, but the INJ_ANG loop zeros PIT2 but the PIT1 error signal remains. There's too options to avoid this, either do a combination of ZM1/3 to avoid cross coupling, but the easier option is to keep the INJ_POS loop slower (gain lower) than INJ_ANG. The change was very small (or no change) for YAW1 so we decided to only use PIT1/2 to INJ_ANG to ZM3 P/Y as the feedback for this week.

  Optical ALIGN INJ ANG ASC_ADS Matrix Element Needed
ZM3 P +3 on ZM3 P -0.00480 in P +5.978 on PIT2 -0.0008 (much too small, increased to -0.08)
ZM3 Y -7 on ZM3 +0.0095 in Y -4.6 on YAW2 -0.002 (wrong sign, too small, changed to +0.06)

Edited SQZ_FC guardian OFFLOAD_FC_ASC to also offload INJ_POS if we decide to use these filters. As the intergrators as still in the FC ASC filters, this is a homemade ASC offload, rather than the standardized ISC one. A future task is to move the intergrators into the ZM suspensions as we did for ZM4/5/6.

Accepted sdfs, and checked the that FC Guarudan just switches on the  SQZ-FC_ASC_INJ_ANG_P/Y inputs and doesn't touch the matrix elements. INIT did reset the outmarix, but this should be controlled only by sdf so I deleted that block and reloaded.

Images attached to this report
Comments related to this report
sheila.dwyer@LIGO.ORG - 12:07, Monday 10 March 2025 (83271)

We did split up the filters for the filter cavity ASC, adding intergrators with a zero at 0.01 Hz to FC1,2 and ZM3 ASC filter banks (M1_LOCK_P and Y), and modifying the true intergators in the ASC filters to have poles at 0.01 Hz.  Then we modified the guardian so that it uses the standard generic offloading guardian state (gen_OFFLOAD_ALIGNMENT_MANY).  We also removed the state called clear_FC_ASC from the graph, because that shouldn't be needed if we are using the standard offloading guardian. 

 

Images attached to this comment
LHO VE
david.barker@LIGO.ORG - posted 10:21, Monday 10 March 2025 (83266)
Mon CP1 Fill

Mon Mar 10 10:08:35 2025 INFO: Fill completed in 8min 32secs

Jordan confirmed a good fill curbside.

Images attached to this report
H1 PSL
ryan.short@LIGO.ORG - posted 09:58, Monday 10 March 2025 (83265)
PSL 10-Day Trends

FAMIS 31076

Nothing really to report this week; trends are looking steady and things are behaving as expected.

Images attached to this report
LHO General
corey.gray@LIGO.ORG - posted 07:39, Monday 10 March 2025 (83262)
Mon DAY Ops Transition

TITLE: 03/10 Day Shift: 1430-2330 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Lock Acquisition
OUTGOING OPERATOR: Ryan S
CURRENT ENVIRONMENT:
    SEI_ENV state: CALM
    Wind: 13mph Gusts, 7mph 3min avg
    Primary useism: 0.03 μm/s
    Secondary useism: 0.35 μm/s
QUICK SUMMARY:

H1 lost lock (7hr lock with "refined" tag) about an hr ago and just finished an initial alignment.  Commissioning time is scheduled in 40+min.

Secondary microseism looks below the 95th percentile (probably following the activity in the N.Atlantic's Greenland/Labrador region).  Winds are breezy just below 20mph and have been fairly constand the last 22hrs.  The big EQ last night was on the small island of Jan Mayen part of Norway (our biggest EQ of the weekend).

H1 DetChar (DetChar)
mattia.emma@LIGO.ORG - posted 05:11, Monday 10 March 2025 (83261)
Data Quality Shift Report 2025-03-03 to 2025-03-09

Link to the report

LHO General
ibrahim.abouelfettouh@LIGO.ORG - posted 22:00, Sunday 09 March 2025 (83260)
OPS Eve Shift Summary

TITLE: 03/10 Eve Shift: 2330-0500 UTC (1630-2200 PST), all times posted in UTC
STATE of H1: Earthquake
INCOMING OPERATOR: Ryan S
SHIFT SUMMARY:

IFO is LOCKING and in ENVIRONMENT due to the 6.6 mag EQ from Iceland that we're still recovering from - Lockloss alog 83259.

The primary microseism is still elevated and will likely take another 30 mins to 1hr to return to pre-EQ levels (which were high to begin with). I began attempting locking ~20 minutes ago but this was not successful. I'll set H1 for initial aligment before my shift ends to give the extra time for microseism to die down.

Other than that, we had a lockloss that seems to have been caused by high ground motion at EY and that kind of correlated with an EQ that happened while secondary microseism and high winds were present - LL tool marked it with the WINDY tag. Lockloss alog 83257. The lock acquisition was fully automatic and only took 1hr 17 mins including initial alignment.

On the bright side, the wind has died down significantly.

LOG:

Start Time System Name Location Lazer_Haz Task Time End
21:33 OPS Ibrahim X-arm N Stroll to MX 22:19
22:20 OPS Corey Optics Lab N Photo of parts 22:46

 

H1 SEI (Lockloss)
ibrahim.abouelfettouh@LIGO.ORG - posted 19:45, Sunday 09 March 2025 (83259)
Lockloss 02:43 UTC

6.6 Mag Iceland EQ Caused Lockloss that happened 4 minutes after we reached NLN again. Ground motion is too high to attempt locking so staying in IDLE until it passes.

H1 General (Lockloss)
ibrahim.abouelfettouh@LIGO.ORG - posted 18:24, Sunday 09 March 2025 - last comment - 19:43, Sunday 09 March 2025(83257)
Lockloss 01:22 UTC

Lockloss from what looks to be seismic motion caused by a 4.9 EQ combo'd with high microseism. The timing doesn't exactly math up though so I'll investigate further.

Comments related to this report
ibrahim.abouelfettouh@LIGO.ORG - 19:43, Sunday 09 March 2025 (83258)

Back to OBSERVING 02:41 UTC.

Buuuuut there's a 6.6 EQ on its way from Iceland so we lost lock again 4 mins later.

LHO General
corey.gray@LIGO.ORG - posted 16:29, Sunday 09 March 2025 (83248)
Sun DAY Ops Summary

TITLE: 03/09 Day Shift: 1430-2330 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Aligning
INCOMING OPERATOR: Ibrahim
SHIFT SUMMARY:

Today (and last night) was ETMx-related with (2) ETMx locklosses (one overnight & one at very start of shift).  Then had almost 5hrs of downtime with 3 locklosses in a row at LOWNOISE_ESD_ETMX (resulting in making some Calls for help, but H1 came back on its own...after pausing for about an hr before this troublesome state---see alogs).  Keita also suggests some measurements we should run next time we are locking.  Secondary microseism has mostly been flat (but maybe if you squint at it right, you can see it possibly drifting down).  Winds have  been around 20mph for much of the last 6hrs.

H1 is finally thermalized, so a calibration could be run (but microseism is high still, so I'd be wary...esp with the grief of getting through LOWNOISE ESD ETMx this morning).
LOG:

LHO General
ibrahim.abouelfettouh@LIGO.ORG - posted 15:58, Sunday 09 March 2025 (83256)
OPS Eve Shift Start

TITLE: 03/09 Eve Shift: 2330-0500 UTC (1630-2200 PST), all times posted in UTC
STATE of H1: Observing at 145Mpc
OUTGOING OPERATOR: Corey
CURRENT ENVIRONMENT:
    SEI_ENV state: CALM
    Wind: 22mph Gusts, 18mph 3min avg
    Primary useism: 0.05 μm/s
    Secondary useism: 0.39 μm/s
QUICK SUMMARY:

IFO is in NLN and OBSERVING as of 19:24 UTC (3.5 hr lock)

IFO is stable but was having issues regarding LOWNOISE_ESD_ETMX state, assumed due to high microseism, which is coming down. There were also 2 locklosses. Both the locklosses and locking issues are detailed in Corey's alog 83249.

LHO VE
david.barker@LIGO.ORG - posted 10:27, Sunday 09 March 2025 (83250)
Sun CP1 Fill

Sun Mar 09 10:08:50 2025 INFO: Fill completed in 8min 47secs

 

Images attached to this report
H1 SUS (SEI, SUS)
corey.gray@LIGO.ORG - posted 10:16, Sunday 09 March 2025 - last comment - 12:30, Sunday 09 March 2025(83249)
2-Consecutive ETMx Glitch Locklosses & Now 2-Consecutive LOWNOISE_ESD_ETMx Locklosses

Over roughly 7hrs, we had 2-consecutive ETMx Glitch locklosses taking H1 down from OBSERVING.

After that last lockloss, have had 2-consecutive LOWNOISE_ESD_ETMX locklossess while trying to get H1 back.  An alog search on LOWNOISE_ESD_ETMX lockloss issues were noted in alog82912.  Since we are having a similar situation (high microseism and frequent locklosses at this state), I made changes to LOWNOISE_ESD_ETMX in ISC_LOCK.py by increasing the (1) ETMx ramp time & (2) a timer after this step (see attached):

Change Save & Loaded for ISC_LOCK and we are currently on the way to see if we can get through LOWNOISE_ESD_ETMX (or have a 3rd Consecutive lockloss here).

Images attached to this report
Comments related to this report
corey.gray@LIGO.ORG - 10:44, Sunday 09 March 2025 (83251)

Well, that didn't work.  H1 had a 3rd-consecutive lockloss within a couple seconds of going through LOWNOISE_ESD_ETMX.  (Posted situation on mattermost & consulting the Call List for assistance.)

So, I am restoring the (1)  etmx_ramp back to 20 (from my 60) & (2) self.timer['ETMswap']  back to 30 (from 60).

Attached is the restored values noted above.

Below you can see what happened---lockloss happened FAST within 4-seconds of starting LOWNOISE_ESD_ETMx.  Jim wsa first on the call list and he asked if his ETMx ESD limit steps happen---they did not even get to try---that step is the LAST step for LOWNOISE_ESD_ETMx.

Here is the ISC_LOCK for this lockloss:

2025-03-09_17:35:40.042953Z ISC_LOCK [TRANSITION_FROM_ETMX.run] timer['ETMswap'] done
2025-03-09_17:35:40.092335Z ISC_LOCK [TRANSITION_FROM_ETMX.run] ADS convergence check
2025-03-09_17:35:40.195243Z ISC_LOCK EDGE: TRANSITION_FROM_ETMX->LOWNOISE_ESD_ETMX
2025-03-09_17:35:40.195907Z ISC_LOCK calculating path: LOWNOISE_ESD_ETMX->NOMINAL_LOW_NOISE
2025-03-09_17:35:40.196027Z ISC_LOCK new target: LOWNOISE_LENGTH_CONTROL
2025-03-09_17:35:40.201276Z ISC_LOCK executing state: LOWNOISE_ESD_ETMX (558)
2025-03-09_17:35:40.206296Z ISC_LOCK [LOWNOISE_ESD_ETMX.enter]
2025-03-09_17:35:40.216682Z ISC_LOCK [LOWNOISE_ESD_ETMX.main] switching ESD back to ETMX
2025-03-09_17:35:40.217217Z ISC_LOCK [LOWNOISE_ESD_ETMX.main] ezca: H1:SUS-ITMX_L3_LOCK_L_TRAMP => 60
2025-03-09_17:35:40.217751Z ISC_LOCK [LOWNOISE_ESD_ETMX.main] ezca: H1:SUS-ITMX_L3_LOCK_L_GAIN => 0
2025-03-09_17:35:40.218187Z ISC_LOCK [LOWNOISE_ESD_ETMX.main] ezca: H1:SUS-ETMX_L3_LOCK_L_TRAMP => 60
2025-03-09_17:35:40.218678Z ISC_LOCK [LOWNOISE_ESD_ETMX.main] ezca: H1:SUS-ETMX_L3_LOCK_L_GAIN => 1
2025-03-09_17:35:40.219270Z ISC_LOCK [LOWNOISE_ESD_ETMX.main] ezca: H1:SUS-ETMY_L3_LOCK_L_TRAMP => 60
2025-03-09_17:35:40.219711Z ISC_LOCK [LOWNOISE_ESD_ETMX.main] ezca: H1:SUS-ETMY_L3_LOCK_L_GAIN => 0
2025-03-09_17:35:40.219923Z ISC_LOCK [LOWNOISE_ESD_ETMX.main] timer['ETMswap'] = 60
2025-03-09_17:35:44.717933Z ISC_LOCK [LOWNOISE_ESD_ETMX.run] Unstalling IMC_LOCK
2025-03-09_17:35:44.853115Z ISC_LOCK [LOWNOISE_ESD_ETMX.run] USERMSG 0: IMC_LOCK: has notification
2025-03-09_17:35:45.067039Z ISC_LOCK JUMP target: LOCKLOSS
2025-03-09_17:35:45.070405Z ISC_LOCK [LOWNOISE_ESD_ETMX.exit]
2025-03-09_17:35:45.140996Z ISC_LOCK JUMP: LOWNOISE_ESD_ETMX->LOCKLOSS

2025-03-09_17:35:45.141251Z ISC_LOCK calculating path: LOCKLOSS->NOMINAL_LOW_NOISE
2025-03-09_17:35:45.142460Z ISC_LOCK new target: DOWN
2025-03-09_17:35:45.150074Z ISC_LOCK executing state: LOCKLOSS (2)
2025-03-09_17:35:45.150466Z ISC_LOCK [LOCKLOSS.enter]
2025-03-09_17:35:45.154072Z ISC_LOCK [LOCKLOSS.main] ezca: H1:GRD-PSL_FSS_REQUEST => READY_FOR_MC_LOCK
2025-03-09_17:35:45.267242Z ISC_LOCK JUMP target: DOWN
2025-03-09_17:35:45.271745Z ISC_LOCK [LOCKLOSS.exit]
2025-03-09_17:35:45.331052Z ISC_LOCK JUMP: LOCKLOSS->DOWN
2025-03-09_17:35:45.331185Z ISC_LOCK calculating path: DOWN->NOMINAL_LOW_NOISE

 

Images attached to this comment
corey.gray@LIGO.ORG - 11:15, Sunday 09 March 2025 (83252)

None of the first 3 LOWNOISE_ESD_ETMx (558) locklosses have an IMC tag.  (3rd one had a WINDY tag & we did transition back to SEI_ENV = USEISM at 1721utc (about an hr ago).)

All 3 have the REFINED tag.

corey.gray@LIGO.ORG - 11:33, Sunday 09 March 2025 (83253)

A Look At Microseism with comparson to Elenna's plot in Nov when the microseism season was starting and here we are a few more months into it.  We've certainly had worse days, but we are in the middle of a noisy microseism period at about 600 counts since last night.

STATUS:  Have been holding at MAX_POWER [520]

Images attached to this comment
corey.gray@LIGO.ORG - 12:01, Sunday 09 March 2025 (83254)

Here is a look at the last LOWNOISE_ESD_ETMx (using an Elenna template).

Images attached to this comment
corey.gray@LIGO.ORG - 12:30, Sunday 09 March 2025 (83255)

For the 4th locking attempt, time settings were restored (from change I made), and on this one I held at MAX POWER [520] for about 50min while reading through alogs, looking at previous lockloss to post in the alog and then eventually just continued on, and this time, H1 made it thru LOWNOISE_ESD_ETMx.  Attached you can see how things looked going from TRANSITION FROM ETMX [557] to LOWNOISE ESD ETMX [558]....in contrast to my lockloss alogged earlier, this one looks like sort of like the plot on left from Elenna's scopes posted here.

Images attached to this comment
LHO General
corey.gray@LIGO.ORG - posted 07:49, Sunday 09 March 2025 (83247)
Sun DAY Ops Transition

TITLE: 03/09 Day Shift: 1430-2330 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Lock Acquisition
OUTGOING OPERATOR: Ryan S
CURRENT ENVIRONMENT:
    SEI_ENV state: USEISM
    Wind: 10mph Gusts, 6mph 3min avg
    Primary useism: 0.04 μm/s
    Secondary useism: 0.45 μm/s
QUICK SUMMARY:

Happy Spring Forward Morning (& 1-hr less sleep)!

H1 just went down (after a 3h51m lock, and a 1435utc lockloss w/ an ETMx Glitch tag).  Taking H1 immediately into Initial Alignment to skip Locking ALS locklosses. 

The one Owl 932utc lockloss (also an ETMx Glitch tag) was fully automatic (after about 22min of 7 Locking ALS attempts) & no Alignment was needed.

Looks like secondary microseism hit the 95th percentile about 10hrs ago and has stayed there.  Winds are under 10mph.

H1 AOS (ISC, SUS)
joshua.freed@LIGO.ORG - posted 10:50, Tuesday 22 October 2024 - last comment - 10:48, Monday 10 March 2025(80814)
PR3 damping contributions to DARM

J. Freed, S. Dwyer

 

Yesterday we did damping loop injections on all 6 BOSEMs on the PR3 M1. PR3 shows quite alot of coupling in the 10-25Hz range. This is a continuation of the work done previously for ITMX, ITMY, and PR2

As some signals were quite strong, instead of gain of 750, gains of 300 and 600 were collected (300 is labled as low_noise). Also, this time injections were performed in diaggui instead of awggui

The plots, code, and flagged frequencies are located at /ligo/home/joshua.freed/20241021/scrpts. While the diaggui files are at /ligo/home/joshua.freed/20241021/data. This time, 600 gain data was also saved as a reference in the diaggui files (see below), saved in 20241021_H1SUSPR3_M1_OSEMNoise_T3.xml

pr3.png Shows all results for PR3 with the top half being at 300 gain and the bottom being at 600 gain. All sensors showed strong coupling in 10-25Hz range at 600 gain. [LF, RT, T2, T3] showed strong coupling in 10-25Hz range at 300 gain. [SD, T1] instead showed some coupling in the 46-48Hz range at 300 gain. I am unsure if this is signifficant or another noise source while the test was performed.

DiagguiInj.png Shows the set up for the injections in Diaggui. The ramp up and down values in measurment tab were also set to 5sec
 
GPS Times of injections (reference number in diaggui files)
Background time:      1413584423 (ref0 DARM, ref1 LF_out, ref2 RT_out, ref3 SD_out, ref4 T1_out, ref5 T2_out, ref6 T3_out)
LF(low_noise) time:    1413585519
LF time:                        1413585643 (ref7 DARM, ref8 LF_out)
RT(low_noise) time:    1413585954
RT time:                        1413586086 (ref9 DARM, ref10 RT_out)
SD(low_noise) time:   1413586349
SD time:                       1413586510 (ref11 DARM, ref12 SD_out)
T1(low_noise) time:    1413586757
T1 time:                        1413586873 (ref13 DARM, ref14 T1_out)
T2(low_noise) time:    1413587139
T2 time:                        1413587245 (ref15 DARM, ref16 T2_out)
T3(low_noise) time:    1413587436
T3 time:                        1413587545 (ref17 DARM, ref18 T3_out)

 

 

Images attached to this report
Comments related to this report
joshua.freed@LIGO.ORG - 10:48, Monday 10 March 2025 (83268)

Adding a plot to show the individual PR3 BOSEM Contributions

Images attached to this comment