Displaying reports 83321-83340 of 86768.Go to page Start 4163 4164 4165 4166 4167 4168 4169 4170 4171 End
Reports until 16:12, Monday 23 July 2012
LHO General
gerardo.moreno@LIGO.ORG - posted 16:12, Monday 23 July 2012 (3546)
Ops Summary

Activities of the day of which I was informed:

- Elli K. to visit Y-END station, ALS table work, 8:57 - 11:18 am.

- Karen R. clean floor in the LVEA, 9:00 - 11:58 am.

- Hugh R. work in and around HAM03, all day.

- Filiberto C. work in the corner station VEA, briefly around 10:38 am.

- Karen R. work @ Y-END, clean different areas, including the floor inside the vacuum support equipment room, 1:45 - 3:45 pm.

- Cheryl V. work at Y-END, TMS, 2:51 - 3:55 pm.

- Jason O. alignment work, 2:55 - 3:50 pm.

H2 ISC
alberto.stochino@LIGO.ORG - posted 15:28, Monday 23 July 2012 (3544)
ALS Reference cavity locked again

We found that the reference cavity had lost lock.

I relocked it by disconnecting the fast and slow inputs, tweaking a bit the temperature knob and re-connecting the input cables.

The cavity is now likely locked to a different FSR from before. This means that the beat note at the end station might now be falling out of the PD bandwidth.

We have to go to end Y and adjust the ALS laser temperature to get the beat note in the PD range again.

H1 AOS
thomas.vo@LIGO.ORG - posted 15:07, Monday 23 July 2012 - last comment - 08:50, Thursday 26 July 2012(3543)
H2 ETMY Optical Lever Calibration
I have taken the calibration data and analyzed it. The plot of the linear response curve is attached.

I used a polynomial fitting program in python to get these numbers.  This should give you the conversion from volts to micro-radians.

           Slope            Y-intercept
Pitch   [  1.01902201e+06   8.42886118e+00]
Yaw     [  9.83122943e+05  -1.19329010e+01]
Comments related to this report
thomas.vo@LIGO.ORG - 19:11, Monday 23 July 2012 (3550)
Please hold off on using these calibration parameters, it looks like the SUS readout channels that map out the quadrants on ETMY and ITMY were not correct and I will need to re-calculate if this is true. Updates soon to come.
thomas.vo@LIGO.ORG - 14:25, Tuesday 24 July 2012 (3564)
The QPD mapping did prove to be different than what was previously shown on the MEDM screens.

Here are the new values for the linear response curve. The units are micro-radians/volts. The lever arm is taken to be 6 meters still 

Pitch [ 1727.67131855    23.41350328]
Yaw   [ 1666.80728788   -33.14694715]


It is relevant to address that a positive pitch on the ETMY quad suspension MEDM on the m0 stage will yield a higher intensity on the two lower quadrants of the optical lever QPD, giving a negative pitch as viewed facing the QPD. 
Also, a positive yaw in the quad suspension MEDM will yield a higher intensity on the two left quadrants of the optical lever QPD, giving a negative yaw as viewed facing the QPD. For alignment purposes this will be important to note.  

The next step is to take measurements over the course of at least 2-6 hours and measure the drift as a function of time.
Images attached to this comment
thomas.vo@LIGO.ORG - 08:50, Thursday 26 July 2012 (3588)
I copy and pasted wrongly into the screen the pitch and yaw are reversed, this is signal(1/m) vs translation(micro-radians) which gives units of micro-radians*meters.
       Slope              Y-intercept
Pitch [1666.80728788   -33.14694715]
Yaw   1727.67131855    23.41350328]

Apologies
Images attached to this comment
LHO General
alexan.staley@LIGO.ORG - posted 14:19, Monday 23 July 2012 (3542)
Returned Broadband Photodetector S1200235
I have returned the broadband photodetector (S1200235) to its original box in MY. 
X1 SUS
james.batch@LIGO.ORG - posted 13:48, Monday 23 July 2012 (3541)
X1 Tripleteststand running intermittently
The tripleteststand is malfunctioning - Symptoms are GPS time for user model and IOP model freezes at some time (identical for both), killing the user model and restarting the IOP results in a GPS time of 0, and the IOP indicates no ADC/DAC cards exist.  There is an interesting dialog which can be brought up using the dmesg command:

[13290.003398] x1ioptriple: Allocated daq shmem; set at 0xffffc9001a10d000
[13290.003399] x1ioptriple: configured to use 5 cards
[13290.003400] x1ioptriple: Initializing PCI Modules
[13290.003408] x1ioptriple: ADC card on bus a; device 4 prim a
[13290.003409] x1ioptriple: adc card on bus a; device 4 prim a
[13290.003415] x1ioptriple: pci0 = 0xffffffff
[13290.003423] resource map sanity check conflict: 0xffffffff 0x1000001fe 0xffc00000 0xffffffff reserved
[13290.003426] ------------[ cut here ]------------
[13290.003431] WARNING: at arch/x86/mm/ioremap.c:98 __ioremap_caller+0xd5/0x301()
[13290.003432] Hardware name: X8DTU
[13290.003433] Info: mapping multiple BARs. Your kernel is fine.
[13290.003434] Modules linked in: x1ioptriplefe(+) mbuf [last unloaded: x1ioptriplefe]
[13290.003437] Pid: 5760, comm: insmod Not tainted 2.6.34.1 #7
[13290.003438] Call Trace:
[13290.003442]  [] warn_slowpath_common+0x77/0x8f
[13290.003444]  [] warn_slowpath_fmt+0x3c/0x3e
[13290.003446]  [] __ioremap_caller+0xd5/0x301
[13290.003449]  [] ? T.484+0x13/0x15
[13290.003451]  [] ? pci_bus_read_config_dword+0x66/0x74
[13290.003452]  [] ioremap_nocache+0x12/0x14
[13290.003457]  [] mapAdc+0x65/0x251 [x1ioptriplefe]
[13290.003461]  [] mapPciModules+0x6c1/0x824 [x1ioptriplefe]
[13290.003465]  [] init_module+0x242/0x97d [x1ioptriplefe]
[13290.003468]  [] ? init_module+0x0/0x97d [x1ioptriplefe]
[13290.003471]  [] do_one_initcall+0x59/0x149
[13290.003475]  [] sys_init_module+0xd1/0x231
[13290.003477]  [] system_call_fastpath+0x16/0x1b
[13290.003478] ---[ end trace 31c35fdb3a0a9ba9 ]---
[13290.003481] ioremap reserve_memtype failed -22
[13290.003483] x1ioptriple: pci2 = 0xffffffff
[13290.003485] resource map sanity check conflict: 0xffffffff 0x1000001fe 0xffc00000 0xffffffff reserved
[13290.003487] ioremap reserve_memtype failed -22
[13290.003488] x1ioptriple: ADC I/O address=0xffffffff  0x0
[13290.003491] BUG: unable to handle kernel NULL pointer dereference at (null)
[13290.003919] IP: [] mapAdc+0xd8/0x251 [x1ioptriplefe]
[13290.004137] PGD 1b7cbc067 PUD 1b7c84067 PMD 0 
[13290.004352] Oops: 0000 [#1] SMP 
[13290.004562] last sysfs file: /sys/devices/pci0000:00/0000:00:1e.0/0000:27:01.0/class
[13290.004974] CPU 2 
[13290.004979] Modules linked in: x1ioptriplefe(+) mbuf [last unloaded: x1ioptriplefe]
[13290.005596] 
[13290.005801] Pid: 5760, comm: insmod Tainted: G        W  2.6.34.1 #7 X8DTU/X8DTU
[13290.006215] RIP: 0010:[]  [] mapAdc+0xd8/0x251 [x1ioptriplefe]
[13290.006637] RSP: 0018:ffff8801b7d49dc8  EFLAGS: 00010292
[13290.006846] RAX: 000000000000003f RBX: 0000000000000000 RCX: 000000000000003f
[13290.007059] RDX: 0000000000020cc5 RSI: ffffffff8179c135 RDI: 000000000000000a
[13290.007272] RBP: ffff8801b7d49df8 R08: 000000007ffffff2 R09: 000000000000000a
[13290.007487] R10: 0000000000000006 R11: 00000000ffffffff R12: ffffffffa000f130
[13290.007701] R13: ffff8801be8ad800 R14: 0000000000000000 R15: 0000000000000000
[13290.007914] FS:  00007f957e7836f0(0000) GS:ffff880001e40000(0000) knlGS:0000000000000000
[13290.008326] CS:  0010 DS: 0000 ES: 0000 CR0: 0000000080050033
[13290.008537] CR2: 0000000000000000 CR3: 00000001a165d000 CR4: 00000000000006e0
[13290.008746] DR0: 0000000000000000 DR1: 0000000000000000 DR2: 0000000000000000
[13290.008955] DR3: 0000000000000000 DR6: 00000000ffff0ff0 DR7: 0000000000000400
[13290.009165] Process insmod (pid: 5760, threadinfo ffff8801b7d48000, task ffff8801bdd0f200)
[13290.009571] Stack:
[13290.009771]  0000000000000000 ffffffffa000f130 0000000000000001 0000000000000000
[13290.009985] <0> 0000000000000000 0000000000000000 ffff8801b7d49e48 ffffffffa00087b7
[13290.010401] <0> ffff8801b7d49e18 00000000b7d49e58 ffff8801b7d49e48 ffff8801b7d49e58
[13290.011023] Call Trace:
[13290.011231]  [] mapPciModules+0x6c1/0x824 [x1ioptriplefe]
[13290.011445]  [] init_module+0x242/0x97d [x1ioptriplefe]
[13290.011659]  [] ? init_module+0x0/0x97d [x1ioptriplefe]
[13290.011872]  [] do_one_initcall+0x59/0x149
[13290.012081]  [] sys_init_module+0xd1/0x231
[13290.012291]  [] system_call_fastpath+0x16/0x1b
[13290.012501] Code: 00 02 00 00 e8 0c cc 01 e1 8b 35 91 e8 49 00 48 89 c2 49 89 c6 48 c7 c7 fc d3 00 a0 31 c0 e8 a9 57 00 00 4e 89 34 fd 20 5e 01 a0 <41> 8b 36 48 c7 c7 19 d4 00 a0 31 c0 e8 90 57 00 00 4a 8b 14 fd 
[13290.013247] RIP  [] mapAdc+0xd8/0x251 [x1ioptriplefe]
[13290.013468]  RSP 
[13290.018602] CR2: 0000000000000000
[13290.019122] ---[ end trace 31c35fdb3a0a9baa ]---

The only way to recover is to power the computer off, then power the I/O Chassis off at the power supply, wait, then power up the I/O Chassis, then the computer.  The IOP model can be started normally at that point, followed by the user model.  So far, the system has died three times since Wednesday July 18.
H2 ISC
alberto.stochino@LIGO.ORG - posted 13:44, Monday 23 July 2012 - last comment - 23:39, Monday 23 July 2012(3540)
ALS laser input power increased?

[Bram, Alberto]

Both the ALS REFL PD and the TMS green QPDs are showing larger counts than before the weekend. It looks like the trend started sometime between Friday and Saturday night.

See attached plots. The REFL PD is set with a negative gain so that it reads 0 when the arm was unlocked, and it beceomes postive when the arm is locked.

Now we read around -4000 cts when the arm is unlocked.

Also the green QPD segments, both A and B read around 2200 cts, vs about 2000 as they did before.

We're not yet sure if this means that there's actually more physical power in the beam going. If that was the case, then it would be quite strange.

Could it be a DAQ artefact?

Images attached to this report
Comments related to this report
bram.slagmolen@LIGO.ORG - 23:39, Monday 23 July 2012 (3554)

This maybe have to do someting with the PLL being out of lock, with the intergrator railing both the temp and the PZT feedback. Although I don't know the mechanism, but it may seem that there is more green being generated???

After we disabled the PLL servo and cleared the integrator (in Beckhoff), the pwoer seemed to be fine. When we engaged the temp controller (slow servo and integrator in the Beckhoff), after a little while (2-5 min), the power on the green REFL_PD_DC seemded to 'increase'. 

We haven't measured the power levels in the end-station, as we had bigger fish to fry... see a later post.

H2 AOS
thomas.vo@LIGO.ORG - posted 07:38, Monday 23 July 2012 (3539)
H2 ETMY Optical Lever Install and Calibration
The H2 ETMY optical lever is fully installed with the beam reflecting off the front surface of the optic, picture of the beam is attached to show beam size.

Calibration data has been taken and being processed, the linear response curve needs to be implemented in the C-code written by Jeff Kissel.  The hysteresis within the gears of the translation stage on the receiver side could be a factor in the accuracy of the calibration.
Non-image files attached to this report
H2 SEI
vincent.lhuillier@LIGO.ORG - posted 23:17, Saturday 21 July 2012 (3538)
Status of the seismic subsystems used for the single arm

This alog gives a quick status of the seismic systems (HEPIs and ISIs) used for the single arm test (BSC6 and BSC8).

BSC-ISI:
ISI-BSC8 has been running with damping loops and Isolation loops since the end of May with decent isolation performance. https://alog.ligo-wa.caltech.edu/aLOG/index.php?callRep=2976

ISI-BSC6 commissioning started more recently. An overall amplification of the motion was immediately noticed around 1Hz (QUAD mode). By the time, writing the commissioning scripts and controlling HEPI was the priority and the no time was spent on ISI-BSC6 to fix the “1Hz” issue.

This week, some modifications were made to the complementary filters that are used to build the blend filters. The initial filters were replaced by less aggressive ones (smaller bump around the blend frequency (750mHz, 250mHz) and less roll off on the low pass. I have attached a link to bode plots of the 4 complementary filters currently used.
LHO_ISI_BSC6_BSC8_OAT_Complementary_Filters_2012_07_20.fig

The blend and isolation filters currently implemented on the two ISIs are designed using the following parameters:
- Blend at 750mHz on all degrees of freedom except on stage 1 in the Y direction where a 250mHz Blend is used instead.
- UGF: 15Hz on all DOFs
- Phase margin > 45deg
- Gain margin>20dB
- Gain peaking <2

The isolation filters used on the two ISIs are pretty closed. Spectra were measured on the ISIs in the undamped and the isolated state. The performances are OK for now. Optimization will be done later.

Stage 2 GS13 spectra are presented below. The scrip that is used to measure the spectra in the different configuration is currently being reworked. The tails of the spectra in the two uncontrolled and the controlled configurations should match better.

BSC-ISI – ITMY (BSC8):
- LHO_ISI_BSC8_ASD_m_CART_ST2_GS13_Undamped_vs_Isolated_2012_07_18_162209.fig

BSC-ISI – ITMY (BSC6):
- LHO_ISI_BSC6_ASD_m_CART_ST2_GS13_Undamped_vs_Isolated_2012_07_19_151614.fig

The HEPI was commissioned fairly quickly to lock stage 0 of the ISI to the ground. Recently, the TMS-QUAD alignment offsets were offloaded on HEPI-BSC6 (250*10^-6 rad in the +RZ direction).

The HEPI are tuned using the following parameters:
- Blend at 800mHz
- UGF: 10Hz
- Phase margin > 45deg
- Gain margin>20dB
- Gain peaking <2
- Pringle modes are controlled (AC)
- No sensor corrections but the STS-2 are in place, connected, leveled and working.

I have attached spectra of the super sensor signals when the HEPI is uncontrolled and controlled.

HEPI – ITMY (BSC8):
- LHO_HPI_BSC8_ASD_m_Super_Sensors_H_Undamped_vs_Isolated_2012_06_20_170452.fig
- LHO_HPI_BSC8_ASD_m_Super_Sensors_V_Undamped_vs_Isolated_2012_06_20_170452.fig

HEPI – ETMY (BSC6):
- LHO_HPI_BSC6_ASD_m_Super_Sensors_H_Undamped_vs_Isolated_2012_07_02_155724.fig
- LHO_HPI_BSC6_ASD_m_Super_Sensors_V_Undamped_vs_Isolated_2012_07_02_155724.fig

Calibration check:
Some measurements were made to check the calibrationand the basis change matrices used on HEPIs and ISIs. Spectra All sensors when no damping on the ISI. Some glitches still need to be fixed (factor of two on HEPI). Couple of glitches still needs to be fixed.
- LHO_ISI_BSC8_ASD_HEPI_BSC_ISI_Undamped_2012_07_18_020214.fig
- LHO_ISI_BSC6_ASD_HEPI_BSC_ISI_Undamped_2012_07_18_020214.fig


During the “1Hz chase” on ISI-BSC6, the reconstruction scripts that are used to build the hundred of filters, required to control the ISI, from a unique set of measurements (ISI undamped) were fully verified for the first time. Excellent agreements between measurements and simulations were seen even on the cross couplings between stages. These scripts allow a huge gain of time during commissioning.
A nice step forward was done during the last few weeks.

H1 SEI
corey.gray@LIGO.ORG - posted 13:39, Saturday 21 July 2012 (3537)
HAM3 Cabling: Corner3

[HAM3 In-chamber work from 11:30am-1:15pm]

After staking out ISI Corner3 Cabling work on Thursday, I went about dressing the Corner 3 GS13 pigtail cable, one of the more important to dress since these are the only ISI cables which come from the suspended Stage1 to Stage0 (we have to be careful there are no seismic shorts).   So between Stage 1 & 0, the cable must be dressed just right--not too tight, and not too loose.  Between Stages, you also have to elimate any sort of rubbing.  Basically you have to have a good eye's view and be very precise with clamping these cables. 

This is hard for Corner3 on HAM2 & HAM3.

So, in to Chamber and on top of the table I went.  To minimize head rushes/passing out, and gettingoverly overheated, I slowly did work in small steps (either upside down, or by keeping head level with torso and reaching down to the breadboard area).  I removed all other ISI cables from the tiny breadboard we had.  I then dressed the H3 & V3 GS13 cables to their own clamp on Stage0.  I did this such that each cable had a nice & clean "S" run between stages.  After that I installed the Grounding Bracket (with Extension cable bolted on) on the breadboard.  And I finally connected the pigtail cable to the Bracket. 

During this work, I managed to drop an allen wrench, and it fell below the ISI and landed directly in the center of the HAM Chamber.  Funnily, it wasn't easy to get to the tool!  I ended up performing endoscopic surgery and used a clean cable to pull out the tool.  Note:  this work yielded a "white glove" test in that afterward, my glove ended up getting fairly filthy after rubbing up against the Chamber floor (see attached dirty glove).

So, the GS13 cables are dressed for Corner3 (see attached photos & video).

As for other cables....

For the H3 CPS & Actuator, I'd say we bypass the tiny breadboard, and pull these cables straight down off of Stage0 & then take them to the Center flange (D2).  For the V3 CPS & Actuator, I'd also try to avoid the center breadboard (because it's just hard to do work in there) and go straight to the flange.

Images attached to this report
Non-image files attached to this report
H1 SUS
dale.ingram@LIGO.ORG - posted 09:53, Saturday 21 July 2012 (3536)
Photos from 7/12/12 (HAM3 Suspensions)
Check ResourceSpace for views of PR3 coming out of the can and MC2 receiving the optic.  Both activities occurred on 7/12/12.
Images attached to this report
H2 ISC
keita.kawabe@LIGO.ORG - posted 19:25, Friday 20 July 2012 (3535)
IFO is left locked without VCO offloading to ETMY, and without QPD beam pointing servo

Aligned the cavity using tdsdither @ 19:20.

Left the cavity locked w/o VCO offloading servo to ETMY so we can make a (somewhat) longer term comparison of the ETM angle with (yesterday) and without (tonight) the length drive.

Also QPD servo was disabled so we can see how good or bad the alignment is going to be without active pointing servo.

ETMY L1 damp filters are on (as usual only for L and P).

H2 ISC
keita.kawabe@LIGO.ORG - posted 18:48, Friday 20 July 2012 (3534)
Cavity length drift from yesterday

Attached is a trend of cavity length drift from the yesterday.

The first lock stretch is a 3-hours one that I mentioned in https://alog.ligo-wa.caltech.edu/aLOG/index.php?callRep=3517. The second lock stretch lasted until this morning.

CH2 is the output of the ETMY M0 lock filter. Using 0.48nm/ct calibration, it seems as if the length drift for both of the stretches was about 110 um. You should be able to stitch these two together, so it is something like 220 um over 16 hours period. This could be tidal.

I don't know if our tidal prediction software still works, wiki page says it doesn't work on Linux workstations.

CH3 and CH4 are the output of ETMY oplev. I think these were calibrated by Thomas, but I couldn't find any alog about that, so for now it is uncalibrated.

CH5 is the reflected power which mimics the transmitted power.

Images attached to this report
LHO General
patrick.thomas@LIGO.ORG - posted 18:22, Friday 20 July 2012 (3533)
plots of dust counts
Attached are plots of dust counts > .5 microns in particles per cubic foot.
Non-image files attached to this report
LHO General
michael.rodruck@LIGO.ORG - posted 15:52, Friday 20 July 2012 (3532)
Ops summary
X1 SUS
james.batch@LIGO.ORG - posted 15:46, Friday 20 July 2012 (3531)
Restart X1 triple test stand
Found x1tripleteststand had time frozen at Wednesday evening (July 18).  Could not get models to run, even after restarting the tripleteststand computer and cycling power with the I/O chassis power switch.  Appeared the DAC and ADC cards could not be found.

Ended up turning off power to computer, then turning off power supply to I/O chassis, then powering back up in order.  Started IOP model, then user model, both started properly.

Given the timing, possibly a lightning induced power glitch?  

H1 SEI
jim.warner@LIGO.ORG - posted 15:01, Friday 20 July 2012 (3530)
HAM2 floating on HEPI, mostly
GregG, JimW

The HAM2 ISI is now floating on HEPI. Well, not now, 'cause we lightly re-engaged earthquake stops, but it is currently mostly supported by the springs. We haven't done a level or height check yet, as I don't know where our references are or what height we need to look for, but we are basically ready to start working with IAS on figuring out where we need to move to. Should be able to hammer that out next week.
H1 SUS
betsy.weaver@LIGO.ORG - posted 14:50, Friday 20 July 2012 (3529)
More MC2 Phase 2b testing

This afternoon, I:

- ran and committed to svn, TFs of all 6 DOFs of the glass MC2 chamberside, with the damping loops ON.

- performed svn commit on the exports I did of the 2012-07-20 TFs taken earlier of the all metal MC2, which also required renaming with arbitrary time as the form was incorrect for matlab.

- added all 3 sets of the latest data to the plotallhsts_tfs.m file and committed

Plot comparisons to come.

H2 ISC
bram.slagmolen@LIGO.ORG - posted 14:36, Friday 20 July 2012 (3527)
Optics lab RefCav laser on standby (tripped)

After restoring the Beckhoff system we could not relock the PLL in the end-station.

I turned out the the laser in the optics lab (corner station) was on stand-by, indicating that the 'door' wasn't shut on-time or something similar.

I tickled the laser temperature to find the 00-mode and all is running again.

The PLL in the end-station is running smoothly.

H2 SUS
keita.kawabe@LIGO.ORG - posted 13:19, Friday 20 July 2012 - last comment - 14:37, Friday 20 July 2012(3525)
Calibration of ETMY M0 drive, plus calibration of M0/L1/L2 OSEM sensing. L1 sensing is a factor of 10 off. (updated: It's a digital gain.)

Calibrated ETMY M0 OSEM drive, plus calibration of M0/L1/L2 OSEM sensing, by injecting 0.1Hz drive to M0 while the cavity is locked without low frequency offloading from VCO to ETMY. M0 damping was on but L1 damping was off.

Length drive (e.g. output of TEST and DAMP filters) to displacement

0.48 nm/cts

M0 DAMP_L_IN1 sensing 31 nm/cts
L1 DAMP_L_IN1 sensing 3.2 nm/cts
L2 DAMP_L_IN1 sensing 37 nm/cts

Length drive calibration for M0 stage is 0.48nm/cts, not 1nm/cts.

M0 and L2 OSEM sensing calibration is in a ballpark. According to Stuart JeffK, it should be 38 nm/cts.

L1 OSEM sensing calibration is off by a factor of 10. I checked digital gains but they look OK to me. JeffK called me to tell that Matt put a factor of 10 in SENSALIGN matrix for L which I forgot.

If SENSALIGN matrix element for L were 1, L1 DAMP_L_IN1 calibration would be 32 nm/cts.

Comments related to this report
jeffrey.kissel@LIGO.ORG - 14:17, Friday 20 July 2012 (3526)
And for the record, the ballpark BOSEM calibration (+/- 50% because of variations in OSEMs open light current) is

[m / ct] = (avg sensitivity * Sat Amp. Transimpendance * ADC gain)^(-1)
         = (62.5 [uA/mm] * 240e3 [V/A] * 2^16 / 40 [ct / V])^(-1)
         = 4.0e-8 [m/ct]


The ballpark AOSEM calibration is about the same, 

[m / ct] = (avg sensitivity * Sat Amp. Transimpendance * ADC gain)^(-1)
         = (80 [uA/mm] * 240e3 [V/A] * 2^16 / 40 [ct / V])^(-1)
         = 3.2e-8 [m/ct]

keita.kawabe@LIGO.ORG - 14:37, Friday 20 July 2012 (3528)

What was done:

Disabled VCO to ETMY offloading servo.
Disabled L1 damping.

Injected 0.1Hz 30000 counts excitation into ETMY M0 L lock filter (though I should have done this to DAMP L filters in a retrospect to make it simpler).
 

Measured the transfer coefficient from the exc to Lock filter output and OSEM DAMP L input of M0, L1, L2, and H2:ISC-ALS_EY_ARM_IN1_DQ which is calibrated in nm for the entire frequency range.
H2:ISC-ALS_EY_ARM_IN1_DQ had a coherence of 0.995 for an average of 5, everything else had a coherence of practically 1.

Since M0 damping might have some effect on the measurement (and that's the reason why I should have injected into DAMP_L), I "reproduced" the overall length drive output by adding TEST filter output and DAMP_L filter output transfer coefficients. In the end that didn't matter (only made 1% change).

Drive calibration = [H2:ISC-ALS_EY_ARM_IN1_DQ]/[reconstructed length drive].

Sensing calibration = [H2:ISC-ALS_EY_ARM_IN1_DQ]/[DAMP_L_IN1_DQ].

 

Measuement files are here:

/ligo/home/controls/keita.kawabe/OAT_2012/EY_cal

Displaying reports 83321-83340 of 86768.Go to page Start 4163 4164 4165 4166 4167 4168 4169 4170 4171 End