Displaying reports 83461-83480 of 88461.Go to page Start 4170 4171 4172 4173 4174 4175 4176 4177 4178 End
Reports until 17:16, Thursday 17 January 2013
H1 CDS
david.barker@LIGO.ORG - posted 17:16, Thursday 17 January 2013 (5142)
code changes and restarts

h1seih16: was rebooted several times to verify that the ADC originally in the second slot was bad by moving it to the third slot. It was then removed and the spare good ADC installed.

h1hpiitmy model had some mx_stream issues until I realized I have not included it in the rtsystab file. After this was done and the mx streams restarted on h1seib1 its data is now good.

The DAQ was restarted several times because of the ITMY SUS and ISI changes (slow chans renamed) and the H1EDCU_ECATC1.ini file was added to trend the mode cleaner servo board channels. At this point the new h1peml0 ini file was taken by the DAQ, so the h1peml0 model was restarted (FLOOR->VERTEX name change on Seismometer).

Later DAQ restart to update the front end DAQ status channel list in H1EDCU_DAQ.ini.

H1 COC
gerardo.moreno@LIGO.ORG - posted 16:10, Thursday 17 January 2013 - last comment - 22:04, Thursday 17 January 2013(5140)
BS06 in Oven

(Betsy, Gerardo)

Optic is now in the oven.

Images attached to this report
Comments related to this report
betsy.weaver@LIGO.ORG - 22:04, Thursday 17 January 2013 (5147)

The heat cycle was initiated at ~10:30am, intending to ramp to 34 degC over 2 hours and then soak for 6 hours before returning to room temp.  At 3pm the sensor on the glass probe inside the oven showed 28degC while the controller had reached 34 degC.  I attempted to increase the temp of the controller and add more time to the soak, but during the hour of messing with it the temperature started to slowly drop.  Apparently the controller does not like ramps less than 2 hours and could not resume heating quickly.  Because we were mid cycle, I opted to kill the power since I was leary of adding more time at increased temp during unattended evening hours.  A lesson learned for the next optic/glue cure cycles - set the controller temp to ~40 degC and don't mess with it mid-cycle. 

The BS cure cycle was 28 degC for 4.5 hours - not quite up to spec, but going to have to be good enough.  The optic was left to ramp down to RT naturally overnight.

H1 SUS
travis.sadecki@LIGO.ORG - posted 15:37, Thursday 17 January 2013 (5139)
BS payload work

Today, I added the BS elliptical baffles (both HR and AR) to the suspension in addition to the remaining lower structure support brackets.  As of now, the payload of the SUS is as accurate and complete as it can be without having the optic installed.  It should not change much once the optic is installed (probably on the order of 10s of grams difference?).  Once a decision has been made with regards to the placement of the structure on the ISI table, SEI can rebalance and begin their testing.

Images attached to this report
H1 AOS
patrick.thomas@LIGO.ORG - posted 15:34, Thursday 17 January 2013 (5138)
restarted EPICS OPC gateways for Beckhoff h1ecatey
Did the same as was done for h1ecatc1. There are now three gateways running on this machine. I set the affinities for these tasks to all of the CPUs. This had to be done earlier for h1ecatc1 to fix problems with the EPICS update rate.
H1 SUS
mark.barton@LIGO.ORG - posted 14:14, Thursday 17 January 2013 - last comment - 15:05, Thursday 17 January 2013(5135)
PRM and PR3 OL
Mark B.

Andres backed out the BOSEMs on PRM and PR3, and the AOSEMs were already out, so we measured the OL counts:

prettyOSEMgains(logOLs('H1','PRM'),'PRM')

M1T1 24867 1.206 -12434
M1T2 27695 1.083 -13847
M1T3 26803 1.119 -13401
M1LF 27765 1.081 -13882
M1RT 29899 1.003 -14949
M1SD 26998 1.111 -13499
M2UL 24409 1.229 -12204
M2LL 25575 1.173 -12787
M2UR 25475 1.178 -12738
M2LR 26427 1.135 -13214
M3UL 24962 1.202 -12481
M3LL 24710 1.214 -12355
M3UR 26711 1.123 -13356
M3LR 25557 1.174 -12778

prettyOSEMgains(logOLs('H1','PR3'),'PR3')

M1T1 25835 1.161 -12917
M1T2 30072 0.998 -15036
M1T3 28666 1.047 -14333
M1LF 25623 1.171 -12812
M1RT 25798 1.163 -12899
M1SD 28238 1.062 -14119
M2UL 17706 1.694  -8853
M2LL 20285 1.479 -10142
M2UR 18746 1.600  -9373
M2LR 17714 1.694  -8857
M3UL 17313 1.733  -8656
M3LL 22891 1.311 -11445
M3UR 24376 1.231 -12188
M3LR 17159 1.748  -8580
Comments related to this report
mark.barton@LIGO.ORG - 15:05, Thursday 17 January 2013 (5137)
Mark B.

I entered all the above gains and offsets into the various OSEMINF blocks for PRM and PR3, checked that OSEM2EUL, SENSALIGN, DAMP, DRIVEALIGN, EUL2OSEM and COILOUTF were all correct, and updated the safe.snap files (in the new locations that Jeff K had just moved them to!).
H1 CDS
vincent.lhuillier@LIGO.ORG - posted 13:13, Thursday 17 January 2013 (5134)
SUS-ISI ITMY-ETMY models updates

RCG 2.6.1 now authorizes 512 IPC channels (previously limited at 64 channels with RCG 2.5). The communications channels between the BSC-ISIs and the QUADs were added at ITMY (BSC1) and renamed at ETMY (BSC6).

H1 SUS
jeffrey.kissel@LIGO.ORG - posted 13:04, Thursday 17 January 2013 (5133)
All H1 SUS safe.snap files re-organized
After assessing the location of every subsystem's safe.snaps in the userapps repository, then discussion on the CDS software meeting yesterday, we determined that each subsystem's safe.snap should live here:

/opt/rtcds/userapps/release/${subsystem}/${ifo}/burtfiles/${modelname}_safe.snap

where ${subsystem} = [isi, sus, psl, etc.] , ${ifo} = [l1, h1, i1] , and ${modelname} = name of simulink model (sans the .mdl extension) . ISI and PSL already obey this convention, but SUS had put the .snaps in subfolders of the burtfiles directory named after the optic motivated by still-under-developement Guardian work at LLO. 

As of this entry, all SUS (including h1susim, and h1sustmsy) safe.snaps have been moved out of their sub-folder into the "top level" burtfiles folder, and the corresponding soft link in the target directory has been updated:

controls@opsws1:target 0$ ls -l h1sus*/h1sus*/burt/safe.snap
lrwxrwxrwx 1 controls controls 65 2013-01-17 12:46 h1susbstst/h1susbststepics/burt/safe.snap -> /opt/rtcds/userapps/release/sus/h1/burtfiles/h1susbstst_safe.snap
lrwxrwxrwx 1 controls controls 64 2013-01-17 12:46 h1susetmy/h1susetmyepics/burt/safe.snap -> /opt/rtcds/userapps/release/sus/h1/burtfiles/h1susetmy_safe.snap
lrwxrwxrwx 1 controls controls 62 2013-01-17 12:46 h1susim/h1susimepics/burt/safe.snap -> /opt/rtcds/userapps/release/sus/h1/burtfiles/h1susim_safe.snap
lrwxrwxrwx 1 controls controls 64 2013-01-17 12:46 h1susitmy/h1susitmyepics/burt/safe.snap -> /opt/rtcds/userapps/release/sus/h1/burtfiles/h1susitmy_safe.snap
lrwxrwxrwx 1 controls controls 63 2013-01-17 12:46 h1susmc1/h1susmc1epics/burt/safe.snap -> /opt/rtcds/userapps/release/sus/h1/burtfiles/h1susmc1_safe.snap
lrwxrwxrwx 1 controls controls 63 2013-01-17 12:46 h1susmc2/h1susmc2epics/burt/safe.snap -> /opt/rtcds/userapps/release/sus/h1/burtfiles/h1susmc2_safe.snap
lrwxrwxrwx 1 controls controls 63 2013-01-17 12:47 h1susmc3/h1susmc3epics/burt/safe.snap -> /opt/rtcds/userapps/release/sus/h1/burtfiles/h1susmc3_safe.snap
lrwxrwxrwx 1 controls controls 63 2013-01-17 12:47 h1suspr2/h1suspr2epics/burt/safe.snap -> /opt/rtcds/userapps/release/sus/h1/burtfiles/h1suspr2_safe.snap
lrwxrwxrwx 1 controls controls 63 2013-01-17 12:47 h1suspr3/h1suspr3epics/burt/safe.snap -> /opt/rtcds/userapps/release/sus/h1/burtfiles/h1suspr3_safe.snap
lrwxrwxrwx 1 controls controls 63 2013-01-17 12:47 h1susprm/h1susprmepics/burt/safe.snap -> /opt/rtcds/userapps/release/sus/h1/burtfiles/h1susprm_safe.snap
lrwxrwxrwx 1 controls controls 67 2013-01-17 12:47 h1susquadtst/h1susquadtstepics/burt/safe.snap -> /opt/rtcds/userapps/release/sus/h1/burtfiles/h1susquadtst_safe.snap
lrwxrwxrwx 1 controls controls 64 2013-01-17 12:48 h1sustmsy/h1sustmsyepics/burt/safe.snap -> /opt/rtcds/userapps/release/sus/h1/burtfiles/h1sustmsy_safe.snap
controls@opsws1:target 0$ 

H1 IOO
paul.fulda@LIGO.ORG - posted 00:01, Thursday 17 January 2013 (5132)
IMC locking issues

[Cheryl V, Giacomo C, Paul F]

Today we tried measuring the OLTF at the IMC 'common mode' servo board. This required locking the IMC of course, which we were able to do at about 1pm without much trouble (as previously). With the settings that we were using for the initial locking, we saw a UGF of about 1.8kHz. To compare with William Korth's LLO alog entry 4182 where a UGF of 14kHz was reported, we increased the common mode gain until we matched the UGF of 14kHz. We required a common mode servo gain of 10dB to reach a UGF of 14kHz, whereas at LLO the corresponding gain was -2dB. The difference in gains required (12dB~ factor 4) was close to what we would expect given the different laser power (200mW here versus 1W at LLO). 

However, there was still some work going on around the chamber at that time, so we decided to go for lunch before recording an OLTF to post. After coming back, we then found it very difficult to lock the mode cleaner again. We could get short locks, but nothing more than 15 seconds. As far as we could tell, nothing had changed in terms of gains or offsets inbetween (we had brought the common gain back to our previous locking value of -4dB). We then spent a lot of time trying unsuccessfuly to adjust gains, offsets, and filters to get a stable lock. We did eventually get some longer locks (~30 seconds) after increasing the watchdog limits for MC2 M2 and M3, but then we noticed an oscillation in the length feedback channel after M2 feedback was applied (see attached plot). 

Some possible causes for the change in the locking situation are:

We'll keep trying to get the IMC locking up and running again tomorrow so we can look at some WFS signals.

Non-image files attached to this report
H1 IOO
giacomo.ciani@LIGO.ORG - posted 23:58, Wednesday 16 January 2013 (5131)
IOT1 (aka IOT2L) in the works

[Paul, Cheyl, Giacomo]

 

Between Monday and Tuesday we worked at the IOT1 (also very confusingly known as IOT2L = IOT HAM2 Left). We rearranged the IMC refl beam path according to the layout D0902284 (it had previously been layed down temporarily to get an error signal for the IMC locking asap) with the following exceptions and notes:

- the high power beam dump is not there, so we are going on a normal razor-blades beam dump (we will not be using high power though). Also, the other components on that path are not there/in place.

- as per Chris suggestion, we placed that HWP in front of IO_MCR_BS1 instead of in its original location. However, we noticed that it reduced the power at the RFPD by about 50% (independetly from its orientation), so we decided to remove it untill we are confident with IMC locking.

- the shutter is not there

- the GiGe camera is not yet available, so we put an analog camera in its place

- some adjustment has been done to the WFS path, to accomodate for the focal lenses of IO_MCR_L2 and _L3 that are slightly different than the design values. See the following for details.

A few pictures attached.

 

For the WFS path, we placed IO_MCR_L2 in its nominal position, and performed a beamscan using the Ophir Nanoscan. Beamscan1.pdf shows the fit to the horizontal and vertical beam sizes (w0 is ~50 um for both  horizontal and vertical)

Also, we measured the beam at a fixed position for different rotations of the nanoscan head around the beam axis, to look for systematics in the observed ellipticity, but we didn't find a relevant effect.

After putting IO_MCR_L3 in a position (it turned out to be about 2" further downstream wrt nominal) that would give about the same waist size quoted on the layout (300 um) we repeated the beam scan, shown in Beamscan2.pdf (w0 is ~275 um for horizontal and ~250 um for vertical).

We then placed the two 45 deg mirrors, put the beamscan downstream and identified the positions (in front and after the waist) in which the beamsize was sqrt(2)*waist (this corresponds to +-Zr from the beam waist, or +-45 deg Gouy phase). As these positions are different wrt the horizontal or vertical beam profiles, we placed each WFS at an intermediate one.

Note that, because the optic mounts have slotted bases, we used temporary clamps to place the 45 deg mirrors in the ideal position (beam centered on the mirror and reflecting at 90 deg). However, later on it was decided to slightly move the mirrors so that they could be screwed to the closest usable hole on the table, thus modifying the pathlength to the two WFS (wrt the waist) by a few mm each. The position of the WFS was not corrected, so for now it can be sxpected to be off by that much (the error is anyhow comparable to the difference between the ideal position for the horizontal or vertical beam profile).

It's also worth mentioning that after a few hours that the WFS were connected to the electronics, we noticed that the metallic enclosure of WFS_A (and only that) was unusually hot to the touch(about 40 C?). We disconnected it and run a series of electrical tests both Tuesday evening and Wednesday morning, without finding any evidence of malfunction. It has been connected since this morning and the temperature seems equal of that of WFS_B (i.e. slightly warmer than ambient). We'll occasionally re-check the temperature of the WFS during the next days.

Finally, Cheryl routed the IMC transmitted beam down the periscope and into another analog camera.

Images attached to this report
Non-image files attached to this report
LHO VE
rainer.weiss@LIGO.ORG - posted 18:22, Wednesday 16 January 2013 (5130)
Hydrocarbon test at the yend
Gate valve 18 was closed at 11:45AM and then open again at 3:45PM

Hydrocarbons were still elevated at the y end and easy to measure without 
accumulation on a liquid nitrogen trap. Although water has come down as 1/t,
it seems that the hydrocarbons are not attenuating as quickly. The analysis
of the runs made over the last two days will be available within the next week 
and posted both in this log and in the DCC.
Non-image files attached to this report
H1 SEI
hugo.paris@LIGO.ORG - posted 17:13, Wednesday 16 January 2013 (5129)
IMC: HAM2 HAM3 controls progress

 

Preliminary work:

Input/Output filters: Installed, enabled on both ISIs

Symmetrization filters: Installed, enabled on both ISIs

Damping loops: Installed, running on both ISIs

Blend Filters:   

 

Isolation loops:
 

Level 1 (UGF=10Hz, simplest): 

 

Level 2 (UGF=25Hz, Intermediate): 

-> We will leave HAM2/3-ISIs in this known configuration for the night.

 

Level 3 (UGF=35Hz, Most sophisticated): 
 

UGF = Unity Gain Frequency

* Blend filters used: 
     -X,Y,Z:         100mHz
    -RX,RY,RZ:  250mHz
 

H1 SEI
hugh.radkins@LIGO.ORG - posted 16:35, Wednesday 16 January 2013 (5128)
WHAM2 Update: ***HEPI Locked*** Corner 1 3 & 4 L4Cs leveled with Shims
One more corner down.  Did Corner 3 (SE) on WHAM2 this afternoon.  Was requested to leave the system locked tonight but before locking, maximum local motion was maybe 1 mil so there should be no problem for the Mode Cleaner Crew.
WHAM2 ***HEPI Locked***, but if there is time, tomorrow I'll unlock gain and finish the final corner(SW) at HAM2.
H1 CDS
david.barker@LIGO.ORG - posted 16:22, Wednesday 16 January 2013 (5127)
h1ascimc model

Today I added the h1ascimc model to the DAQ. I installed LLO's SVN version of the safe.snap (12dec2012) which gave a few errors but seems to have gotten the WFS signals going. We also installed the latest fiter module file from LLO (modied 15jan2013).

The initial install h1h1ascimc with dcuid=19 caused some testpoint issues today. This was resolved by removing the dcuid=19 from the testpoint.par file, leaving the correct dcuid=20 in that file.

Note that h1asc0 is still not on the Dolphin IPC network, nor are its PIT and YAW control signals being received by MC1,2,3. We should schedule these changes with the IMC group.

LHO General
michael.rodruck@LIGO.ORG - posted 16:12, Wednesday 16 January 2013 (5126)
Ops summary

Today was split between me, Pablo, and Patrick at the end of the day

LHO VE
kyle.ryan@LIGO.ORG - posted 16:09, Wednesday 16 January 2013 (5125)
Opened GV19
John W. had soft-closed this earlier in the day for Apollo's clean-room craning/repositioning over GV20
LHO VE
kyle.ryan@LIGO.ORG - posted 16:05, Wednesday 16 January 2013 (5124)
Leak tested viewports on HAM2
Indicated He baseline of 4.5 x 10-10 torr*L/sec at start -> 10 second audible blast at each conflat joint and 5 second audible blast in volume between each window and corresponding guard shutter  

Note:  There is still an untested electrical feed-through flange on south side of HAM2 between the support tubes but it is not accessible 
H1 COC
gerardo.moreno@LIGO.ORG - posted 15:32, Wednesday 16 January 2013 (5123)
BS06 Prisms Attached

(Betsy, Gerardo)

 

Both sets of prisms have been glued onto the BS.

Prism SN 41 was used for the ARM side, and Prism SN 40 was used for 180ARM side.

ARM side results:

Measurement from S1 to the fiducial side of the prism, 20.08 mm + 9.99 mm (prism Wp/2)  = 30.07 mm

The measured distance from the centerline of the primary prism to the S1 surface is 30.07 mm, the target is 30.04 mm, so this gives us a +0.03 mm, away from S1 surface, but well within the +-0.1 mm.

 

180ARM side results:

Measurement from S1 to the fiducial side of the prism, 40.07 mm - 10.01 mm (prism Wp/2)  = 30.06 mm

The measured distance from the centerline of the primary prism to the S1 surface is 30.06 mm, the target once again is 30.04 mm, so this gives us a +0.02 mm, away from S1 surface, but well within the +-0.1 mm.

LHO General
patrick.thomas@LIGO.ORG - posted 15:22, Wednesday 16 January 2013 (5121)
replaced dust monitor at LVEA 15
Replaced the dust monitor labeled 'C' at LVEA location 15 in the clean room over BSC1 with the dust monitor labeled 'P'. The dust monitor labeled 'C' was reporting occasional calibration failure errors.
H1 SUS
mark.barton@LIGO.ORG - posted 11:35, Tuesday 15 January 2013 - last comment - 15:33, Wednesday 16 January 2013(5112)
More BS TFs
Mark B.

Travis reports that he found some blade stops touching on the BS, so I'm starting another round of DTT TFs for the BS.
Comments related to this report
mark.barton@LIGO.ORG - 13:50, Tuesday 15 January 2013 (5113)
Mark B.

TFs were attempted but have been put on hold because F1 OSEM was badly centred (21K raw, 7K normalized), causing the IOP WD to trip after a minute or two of the usual level of excitation. Travis is on his way to make adjustments. Measurement Status light will go back on when TFs are resumed.
mark.barton@LIGO.ORG - 09:19, Wednesday 16 January 2013 (5114)
Mark B.

Success: ^/trunk/BSFM/H1/BSTST/SAGM1/Data/2013-01-15_1200_H1SUSBSTST_M1_*_WhiteNoise.xml

All the plots look good.

Correction - plots initially posted were from Monday.
Non-image files attached to this comment
mark.barton@LIGO.ORG - 15:33, Wednesday 16 January 2013 (5122)
Mark B.

Comparison plot.
Non-image files attached to this comment