Displaying reports 85761-85780 of 88368.Go to page Start 4285 4286 4287 4288 4289 4290 4291 4292 4293 End
Reports until 11:02, Wednesday 25 April 2012
H1 AOS
jim.warner@LIGO.ORG - posted 11:02, Wednesday 25 April 2012 (2690)
BSC8 Balanced and ready for IAS
I went back into BSC8 this morning to fix the ISI's weight problem. Ended up bolting 7 of SUS's dog clamps at various points around the optical table, mostly around the top of the quad. I tried to be careful to not to pinch any cables or interfere with any moving parts. We may not be exactly back to where we were ~2 months ago, but everything is back into spec, or at least as close as we can get. IAS is in now taking final measurements.
H2 SUS
jeffrey.garcia@LIGO.ORG - posted 22:24, Tuesday 24 April 2012 (2689)
Measurements running on H2 SUS ITMY
Measurements on the M0 & R0 masses are being run on H2 SUS ITMY.  The estimated completion time is ~4:00 AM PST.
H2 SUS
betsy.weaver@LIGO.ORG - posted 19:55, Tuesday 24 April 2012 (2688)
Read this log before Hughs, for chronological order. (Or because I'm cooler.)
Today:
With Jason on the IAS EQ, I finished the fine alignment of the ITMy chains in pitch and yaw. This required knocking the reaction chain top stage blades to swing it into yaw tolerance.  Jason will likely post numbers tomorrow.

With Garcia, I centered up all 20 OSEMs. 

Closed the ring heater.

Finished adding the test mass EQ stops and brackets.

Handed off the SEI to unlock the ISI.

Garcia may run a TF overnight to make sure we're not rubbing anywhere.  Tomorrow, after SEI finishes fussing about their minor weight issue (ehem), Jason will take a final look at the fully floating SEI/SUS BSC8 assembly for any last minute alignment tweeks.
H1 PSL
oliver.puncken@LIGO.ORG - posted 19:33, Tuesday 24 April 2012 (2687)
Disassembly of the PSL (Part 2)
PSL installation team


pulled back the pump light fibers from LAE to Diode room and disassembled them from the diode boxes. They are coiled now and ready to be put into the new rail between the H1 LDR and the H1 LAE.

Moved cables and electronics from the H2 racks next to the H2 LAE to the H1 racks

Installed the PSL water manifold underneath the (new) optical table. The manifold for the "table water" (powermeters, etc.) is not installed yet, because the CPC connectors are not self-sealing (so they are leaking, if nothing is connected to them). Also, the pressure valve for this circuit needs to be mounted to the new filter cartridges.

Since laser diode rack is not going to be moved in one piece, we started to get the shelves into the new laser diode rack (to be continued).
H2 SEI
jim.warner@LIGO.ORG - posted 18:27, Tuesday 24 April 2012 (2686)
BSC8 Stage 2 Unlocked
HughR, HugoP, JimW, some sus people...

We attempted unlocking and level Stage 2 of the ISI today. The unlock went well, but we were unable to balance the stage. Access to the walls of Stage2, where the balance mass would go, would normally be difficult at best, but in this case it was completely blocked by the Arm Cavity Baffle. Our CPS's indicate that the payload is light, with all sensors reading a few thousand counts high. This is especially true in corner 2, which is currently reading ~14000 counts. That translates to around .003-.004" high. We currently plan to bolt a couple of SUS's large dog clamps to the table as an improvised ballast. Should be a quick fix first thing in the morning. We do have masses designed specifically to mount to the optical table, but we have none of the smaller sizes on site. Even then, the smallest of those masses are 2.5 kg (~5 lbs) which is likely too big to fine tune the balance from the optical table.
H1 SUS
deepakmanoj.nandakumar@LIGO.ORG - posted 18:00, Tuesday 24 April 2012 (2685)
MC1 Assembly Notes

[Jeff B, Deepak K, Andres R and Gerardo M2]

Monday & Tuesday 23rd/24th April 2012

 - The wires for the lower mass was assembled and assembled to the intermediate mass.

 - The Lower mass was hung on the loop after properly placing the wires in the grooves.

 - The intermediate mass is then hung on the lower blades.

 - The Lower blades are then hung freely from the upper blades.

 - The masses were initially aligned and now waiting to be properly aligned.

 - The suspension is fully assembled and all the masses are freely suspended.

LHO FMCS
kyle.ryan@LIGO.ORG - posted 17:39, Tuesday 24 April 2012 (2684)
~1157hrs shut down supply fan 6 (SF06, "Hot Deck supply for OSB+labs) -> ~1700hrs restarted
May have affected dust counts in OSB labs when stopped and when restarted(?)  

Found that the pitch actuator ram operates normally when decoupled from the fan variable pitch/vane assemblies (toggling power with 4-20ma signal removed resets position counter and causes ram to fully retract.  Re-landing 4-20ma signal wires, once reset, allows remote control of ram position).  

The exhaust variable pitch/vane assembly is easy to manually stroke through its range when mechanically decoupled from the actuation system but the intake variable pitch/vane assembly feels dry and has excessive friction.  It is quite difficult to stroke through its range even whilst decoupled from the actuator/crank/exhaust vane.  I had to use a heavy sledge hammer and "tap" with authority to get it to stroke and to change pitch -> For now, I manually left the pitch at reduced flow from the "as found" state then re-coupled everything but I did not re-energize the actuator ram.  As such, no remote pitch adjustment can be made.  The mechanical force needed to stroke the front pitch/vane assembly is too much for the 500lb max. force of the actuator ram.  Also, SF06 is "viby" when compared to SF05.
H1 AOS
jonathan.berliner@LIGO.ORG - posted 17:19, Tuesday 24 April 2012 (2683)
H1 EndX eLIGO Photon Calibrator Deinstalled

Frank Seifert, Jonathan Berliner

We deinstalled the eLIGO EX Pcal system this afternoon. Everything, except for the aluminum support structure, was brought to the LSB Optics Lab. The aluminum support structure was left outside of the End Station by the roll-up door, along with the other scrap. The viewport gate was left closed and the viewport window was not inspected. Though the viewport gate key isn't locked or tagged out (as shown in photo), there are assorted warning stickers on the viewport gate enclosure. Some beam dumps weren't clamped down...we should be more mindful of this in the future.

Images attached to this report
H2 PEM
jenne.driggers@LIGO.ORG - posted 16:49, Tuesday 24 April 2012 (2682)
Accelerometers in place in EY - watch for cones
[Jenne, Jan]
We have started placing accelerometers and cables in the end station, so please be careful when walking near BSC10 and the old H2 racks and the dome.  All accelerometers have cones over them, so step around the cones.  All cables that are in the walking path currently are very short stretches, and are taped to the concrete with cleanroom tape (per Jodi's instructions), and are right near several cones.  

Anyhow, please respect the cones, and step carefully.  
H1 SEI
hugh.radkins@LIGO.ORG - posted 16:24, Tuesday 24 April 2012 (2681)
HAM2 CPS BNC FeedThrus Protected
On Monday Scott (Apollo) installed the Protection Shrouds on the HAM2 BNC FeedThrus--None of the other FeedThrus are very vulnerable so we didn't install the Shrouds there yet.
There is a "No Step" placard on the Shrouds--do please comply.
LHO General
thomas.vo@LIGO.ORG - posted 16:04, Tuesday 24 April 2012 (2680)
04/24/2012 Ops Shift
- De-install of BSC 1,2,3 
- Accelerometers being laid down at end station
- Unifirst came
- H2 Front End PSL shutdown
- Mouse and Key: Door Locks
- Mid Columbia:  Working on forklifts 
- Shutdown of H2 PSL front end

H1 INS
cheryl.vorvick@LIGO.ORG - posted 15:49, Tuesday 24 April 2012 (2679)
BSC3 iLigo ITMX Deinstall - progress, but optic is still in the chamber
The deinstall progressed to the point where the lazy susan is in place, the lift table, teflon highway, and adaptor plate are in place.  However, the shoulder bolts for the tall dog clamps have gone missing and were not found.  Some alternatives were considered and rejected, so Apollo crew and Kyle have come up with an alternative that replaces the missing bolts.  The replacements are being cleaned and then baked overnight, so should be ready for use tomorrow, allowing us to complete the deinstall.

- Cheryl, Jodi, Zack, Caleb, Randy, and Mark D.
LHO General
patrick.thomas@LIGO.ORG - posted 15:37, Tuesday 24 April 2012 (2674)
dust monitor code
I am now running new dust monitor code on h0epics2, which is a Ubuntu workstation. It is running under screen.

There has been a bug in the previous code, such that data does not appear to have been recorded since March 15, 2012 for the following:

Dust monitor in clean room over BSC8
H0:PEM-LVEA_DST15_3     any data for counts > 200
H0:PEM-LVEA_DST15_5     any data for counts > 200

Dust monitor in clean room over test stand in LVEA
H0:PEM-LVEA_DST4_3      any data for counts > 200
H0:PEM-LVEA_DST4_5      any data for counts > 200

Dust monitor in OSB optics lab
H0:PEM-LAB_DST1_3       any data for counts > 20,000
H0:PEM-LAB_DST1_5       any data for counts > 8,000

Dust monitor in OSB bake oven room
H0:PEM-LAB_DST3_3       any data for counts > 20,000
H0:PEM-LAB_DST3_5       any data for counts > 8,000

This was because the audible alarms were set for these dust monitors at these levels. When these alarms went off a signal was sent which was read by the CDS code as an error. The CDS code then set the epics channel to INVALID, and the counts were not updated. This should be fixed in the new code.
LHO General
douglas.cook@LIGO.ORG - posted 12:18, Tuesday 24 April 2012 (2678)
Testing First Contact optical qualities when used in a thin file coating
 (Doug, Margot, Jeff)
We setup the Newport laser collimator and retro-reflected the beam from the First Contact thin film coated HR surface and measured the power both in front of the optic and measured the transmitted power through the optics (2 optics and 2 separate measurements) with and without the First contact. Measurements were taken at ~3M and ~6M distance from laser collimator to HR side of sample optics. Sample optics were coated for 1064nm with both HR and AR coatings and First Contact sprayed on the HR surfaces.
I didn't see a need to set up a BS and try to measure a true reflect from the HR surface. The small difference would still be int the absorption and diffused beam if present and is within usable range.
Parameters:
Newport laser collimator beam dia  ~3.0 cm dia.
Ophir power meter aperture 1.2 cm ²

optic s/n 11: @ 3.0 meters
power at 0º incidence in front of optic 44.4µW
power transmitted through First Contact 39.4 µW = 85.6% T
power transmitted through without First Contact 38.0 µW = 88.7 % T (higher reflectivity)

optic s/n 38: @ 3.0 meters and 6.0meters
power at 0º incidence in front of optic 42.4µW
power transmitted through First Contact 36.5 µW (3.0 meters) = 85.6 % T
power transmitted through First Contact 36.4 µW (6.0 meters) = 85.6 % T
power transmitted without First Contact 34.2 µW (6.0 meters) = 80.7 % T (4.9 % higher reflectivity)

No retro-reflections interference noticed.

"This may work"
Doug
H2 ISC
hugh.radkins@LIGO.ORG - posted 12:03, Tuesday 24 April 2012 (2677)
BSC6 ISC Feedthru Inverted and recabled
Apollo (Mark & Chris) pulled the FeedThru (F2-2) to rotate it 180° to put the 'D' right side up in the usual way.  I didn't know the cables were attached and they were unable to pull them far enough out to allow the cable disconnect enabling them to put in a new copper gasket.  I went inside the chamber to disconnect the cables from the FeedThru.  Refer to D1003085 for flange locations and connection descriptions.
Few things here:
1) The In-Vacuum cables on F2-1 have screws for securing to the FeedThru but they were not secured.  I secured them; these would be the ISC-Picomotors & the Transmon 1064nm 25pin cables.

2) The In-Vacuum cables on F2-2 do NOT have screws in the cable and so they aren't secured.  As we flipped the FeedThru and flipped the cables, I felt it prudent to record the cable numbers:
2a) F2-2C1 (ISC Transmon 532 nm) Cable D1000924, S1104106
2b) F2-2C2 (ISC Transmon Beam Diverter) Cable D1000223, S1104077
I did not trace the cables back to the Transmon so don't know from whence they come.

3) While the FeedThru was install upside down from our usual 'D' faces down orientation, my concern about the in-vac cable possibly being installed incorrectly and damaging the FeedThru or Cable was misplaced.  The 25pin cable cannot be installed upside down.  That misplaced concern comes from the 3pin FeedThru where the Vacuum Side can be installed reversed wrt the outside--see the attached photo if you like.
Images attached to this report
H2 CDS
david.barker@LIGO.ORG - posted 10:37, Tuesday 24 April 2012 (2676)
H2 PSL front end and EPICS decommissioned
I have removed the H2PSL from the following systems: H2 DAQ, h2boot and MEDM overviews. This applies to the H2 PSL front end computer and the Beckhoff control and monitoring computers.
This has closed WP3166
H1 PSL
oliver.puncken@LIGO.ORG - posted 22:09, Monday 23 April 2012 (2675)
Disassembly of the PSL (Part 1)
PSL installation team


H1 crystal chiller preparation: 
We found a leakage inside the chiller, which had been fixed now by getting out the flow turbine and preparing it with some teflon tape. Also, the flow has been decreased via the internal bypass valve (It needs to be below 30 lpm, otherwise the chiller would shut down). This valve needs to be readjusted, as soon as everything is connected.

Disassembly of the water supply from the laser head: 
The laser head (oscillator) has been emptied as a preparation step for getting out the pump fibers and (later) the laser crystals. The hoses and the water manifold are already stored in the H1 laser enclosure (but not mounted / connected yet)

Disassembly of the cabeling: 
We started to disconnect the cables on both ends, the racks and the components inside the LAE (laser heads, DBB, etc.)

The oscillator box has been opened unscrewed from the optical table. A big part of the optics between the oscillatot and the DBB and the Amplifier has been removed and stored on a breadboard, such that this breadboard can be moved over to the H1 enclosure. Thus, we are preparing some room on the table to get the transport frame attached to the oscillator (also, these components are needed in the new enclosure anyway.)

The pump light fibers had been disassembled and pulled out from the LAE. They are stored on the floor next to the LAE (the next step will be to get them out of the rail, running above the LAE roof)
H2 SUS
betsy.weaver@LIGO.ORG - posted 16:12, Monday 23 April 2012 (2673)
H2 ITMy BSC8 work
After some serious hunting, Richard tracked the ITMy L2 problem down to the connection on the external side of the feed thru.  It was on the wrong 25 pin feed thru port.  I will re-cable the insides tomorrow.
LHO General
patrick.thomas@LIGO.ORG - posted 16:02, Monday 23 April 2012 (2671)
Ops Summary
Hanford Fire Department on site
Cleaning of OSB bake oven room
Migration of CDS network to new hardware
H2 SEI
jim.warner@LIGO.ORG - posted 15:25, Monday 23 April 2012 - last comment - 16:19, Monday 23 April 2012(2670)
Seismic activities at BSC8
GregG, JimW

Today at BSC8 we hooked up the last of the HEPI actuators, mostly went off without a hitch. Greg should be posting our dial indicator shifts shortly. For future reference, making vertical adjustments to the horizontal actuators can be made with a small bottle jack. Just place the jack on top of the HEPI base clamp and put the top in contact with the underside of the actuator "shelf". 

After the actuators were hooked up, we went inside and looked at the level of the optical table. Need to confer with Hugh about the results, but it still looks pretty good. Could be as good as no more than a 0.1 mm difference across the table. I say "could be", as the measurement was a little difficult to make. It's hard to read a moving ruler through an auto-level.
Comments related to this report
greg.grabeel@LIGO.ORG - 16:19, Monday 23 April 2012 (2672)
We'll have to get some Benzodiazepine for the next time we have to take levels. 

Attaching the horizontals went fairly smoothly. As Jim stated using a bottle-jack worked well for setting the vertical position. The SE corner horizontal actuator has a bound bolt and was somewhat more difficult to set but it went into place without too much trouble as well. A little bit of prying happened on the actuators to get them centered within their bellows. This caused a bit of movement on the support tubes, but not much.

in thousandths of an inch
        NW   SW   SE   NE
ΔV    1d    3d    7d    5u
ΔX    5s    3s    6n    5n
ΔY    2e    3w

This should hopefully translate to less than 25 μrads of cw* movement.

*Edited from ccw Hugh showed me the error of my ways. This is good though because we were out 70 μrads ccw, so we should now be even closer.
Images attached to this comment