jeffrey.garcia@LIGO.ORG - posted 17:51, Tuesday 07 February 2012 - last comment - 19:04, Tuesday 07 February 2012(2180)
ETMY M0 Open Light Counts
ETMY M0 Open Light counts, offsets, and normalising gain values.  Offsets are calculated by dividing the open light counts by two and multiplied by (-1).  The gain values are calculated such that the open light counts are normalised to 30,000cts.
----------------------------
M0:

tdsavg 30 H2:SUS-ETMY_M0_OSEMINF_F1_IN1 H2:SUS-ETMY_M0_OSEMINF_F2_IN1 H2:SUS-ETMY_M0_OSEMINF_F3_IN1 H2:SUS-ETMY_M0_OSEMINF_LF_IN1 H2:SUS-ETMY_M0_OSEMINF_RT_IN1 H2:SUS-ETMY_M0_OSEMINF_SD_IN1
25685.5
29665.2
26661.4
30932.4
27570.6
29929.9

OSEMINF OFFSETS:
F1 = -12843
F2 = -14833
F3 = -13331
LF = -15466
RT = -13785
SD = -14965

OSEMINF GAINS:
F1 = 1.168
F2 = 1.011
F3 = 1.125
LF = 0.970
RT = 1.088
SD = 1.002
Comments related to this report
jeffrey.garcia@LIGO.ORG - 19:04, Tuesday 07 February 2012 (2181)
The M0 OSEMs on the ETMY QUAD are now backed off completely to expose the full light beam on the PDs. The SUS crew will center these OSEMs so TFs can be made before the TMS install. 
H2 SEI
hugh.radkins@LIGO.ORG - posted 17:03, Tuesday 07 February 2012 (2179)
BSC8 HEPI Actuator Parker Valve Replaced
The horizontal HEPI Actuator on the Northwest Corner of BSC8 was replaced under WP 3059.
We shut the Pump Stations off to zero the pressure.  Isolated the Actuator with the 4-way valve.  Swapped the Valve (4 screws).  Put the Actuator in Bleed Mode.  Put the Actuator back in the system and restarted the Pump.  We drop out of bleed mode tomorrow-Wednesday and look for improvement.
LHO General
corey.gray@LIGO.ORG - posted 16:33, Tuesday 07 February 2012 (2177)
Ops Summary

Dust Counts in Bake Out--have called to inform them (will email justin if it happens again)

8:30 Unifirst arrives

Praxair--
-- arrived early at MY's CP3
-- arrived at 841 & went down Xarm direction---maybe CP5 at mx?

* Ski informed that instrument air will be dropping off at EY today
* Kyle informed that he will be overfilling CP8 & turning off instrument air for other work


HAM1 Annulus Ion Pump Alarmed, but Kyle informed that only ones we worry about now are the Gate-Valve ones.

Start H1 MC degrouting (see work permit).  Will prop Southern Exit door for

Doug transitioning EY to Laser Hazard

H2 Alarms (Not sure what I'm supposed to do about these):

--SUS ITMY CPU MAX

--H2 SEI IOP BSC8 CPU MAX

--H2 TCSL0---INVALID & MAJOR alarms

all of these alarms occurred toward the end of the shift

H2 PSL
michael.rodruck@LIGO.ORG - posted 13:43, Tuesday 07 February 2012 (2176)
PSL plots

200W beam

Non-image files attached to this report
H2 SEI
corey.gray@LIGO.ORG - posted 13:30, Tuesday 07 February 2012 (2175)
Closeout Photos For The BSC8 ISI

Before re-installing the BSC8 Dome, I took lots of photos of the BSC8 ISI.  These photos are from Stage0 up to the top of the Keel--basically anything which could be seen from the upper work area of BSC8 (so no photos of the Optics Table were taken).  Quite a few photos were taken, I tried to take pictures of everything with a flash & without (both have their benefits and issues). 

I archived photos according to ISI "corner" and also made an extra collection for the Keel Masses on top.  Here are the collections in ResourceSpace:

Corner 1

Corner 2

Corner 3

Keel Masses On Top

LHO VE
kyle.ryan@LIGO.ORG - posted 13:22, Tuesday 07 February 2012 (2174)
ESD feed-through flange leak tests repeated today
Each 5-channel 4.5" CFF flange had at least one feed-through channel which did not leak but each flange had multiple feed-through channels that did leak (to varying degree).  The largest individual leak on flange "A" was 1.0 x 10-4 torr*L/sec.  The largest individual leak on flange "B" was 3.1 x 10-5 torr*L/sec.
H2 SEI
hugh.radkins@LIGO.ORG - posted 11:53, Tuesday 07 February 2012 (2173)
H2 ITMY (BSC8) SEI State post chamber close-up partII
Due to the HEPI Vertical Actuators being left locked down by an Assembly Tech, the final position numbers for the BSC8 platform I report in aLOG 2150 are not accurate.
I removed the locks this morning and I see a little movement of the system.  The motion is still not large but best to report it.

I now see a 9mil tilt down from SE to NW.  This is a 60µrad tilt and on the BSC optical Table at 77"φ, this would be a 4mil or 0.1mm tilt, if it remained a rigid structure which it isn't when unlocked.  It is however in the same direction of the tilt of the optical table I observed on Jan18.  Result, a 0.2mm tilt has become a 0.3mm tilt.  Does anyone want me to attempt correcting this?

Translation: There is a .005" shift South & a .009" shift West.  As I page back through the aLOG for IAS notes, I'm pretty sure we are nowhere near hitting tolerances for position remaining within .2mm transverse and <1mm longitudinal.

Rotation (Yaw) We translated 10mils South on the East side and just 2mils on the West side for a 60µrad CW rotation.  In aLOG 2069, Doug reports a 10µrad Yaw but I don't know the direction so giving us either a 50 or 70µrad CW Yaw.  Does anyone want me to correct this?

The corrections with HEPI are not easy as the Actuators are attached and they invariably pull or push the system around at these mil scales.
LHO FMCS
john.worden@LIGO.ORG - posted 11:48, Tuesday 07 February 2012 (2172)
YEND Temperature excursion

This weekend the chiller for YEND tripped off on a fault. The second unit was switched on Monday morning. VEA temps are shown in the attached.

Non-image files attached to this report
LHO VE
kyle.ryan@LIGO.ORG - posted 11:28, Tuesday 07 February 2012 (2171)
CP3 and CP5 level alarms due to deliveries-OK, CP8 intentionally overfilled to allow instrument air to be shut down today-OK
Apollo shutting down X-end instrument air supply for the day to reroute lines for QDP80 reorientation.  I will restore LLCV/PID control of CP8 before leaving tonight-but expect CP8 alarms tonight
LHO General
patrick.thomas@LIGO.ORG - posted 19:07, Monday 06 February 2012 (2169)
plots of dust counts
Attached are plots of dust counts > .5 microns.
Non-image files attached to this report
H2 AOS
keita.kawabe@LIGO.ORG - posted 17:24, Monday 06 February 2012 (2168)
TMS

Measured the weight of ISC table + telescope. Using 320D-36, it was 78.2 kg. At first 320D-36 was totally crazy and we needed to recalibrate it using a smaller scale that is normally in the shipping area and about 60kg of aluminum weight.

After that, we brought a Genie with 5-axes attachement in the EY lab. Cube was successfully moved from the Bosch frame to the Genie, and we rotated it 180 degrees in preparation for the installation.

Now both the tele/table and cube are on Genie, and we're fully ready for transport and installation.

Images attached to this report
H1 PSL
michael.rodruck@LIGO.ORG - posted 16:52, Monday 06 February 2012 (2167)
H1 PSL installation

Interior drywall installed today. Remaining drywall pieces and plywood to be installed tomorrow. Patch work/hole drilling the rest of the week.

Images attached to this report
LHO VE
kyle.ryan@LIGO.ORG - posted 16:40, Monday 06 February 2012 (2166)
CP1 alarms are the result of an earlier reboot -> PID response is typical -> Pump level should return to normal range tonight


			
			
LHO VE
kyle.ryan@LIGO.ORG - posted 16:34, Monday 06 February 2012 (2165)
New ESD feedthroughs flanges leak
New 5-channel 4.5" CF ESD feedthrough flanges leak! -> Douglas D., Justin B. and I tested (2) each of these, one of which was to be installed and BSC8 today prior to pumping down the YBM.  Helium responses were large and fast but we did not record the actual peak numbers as we were in a "pass/fail" mindset-these definitely FAIL!  We may repeat test tomorrow and record leak rates for the record.
H2 SUS
betsy.weaver@LIGO.ORG - posted 16:02, Monday 06 February 2012 (2164)
ETMy SUS alignment work
Travis, Jason and I spent most of the day down at EY struggling with the mechanics of ETMy as the chains are not well set in yaw and are proving a pain in the a$$ to align.  In fact, we had to pull the reaction chain away from the main (via EQ stops) just to work on the main without reaction pushing on main.  After ~5 iterations of Top Stage blade tip alignment, we finally ended the day with the main chain hanging at some 500urad out.  Jason reports that this is roughly where we started this morning...

We also fought a differential pitch between the ERM and the PenRe above it - due to the loop.  We attempted to move the loop along the barrel a bit to see if that would help.  It didn't appear to, so that's when we opted to clamp it off away from the main anyways.
LHO VE
cheryl.vorvick@LIGO.ORG - posted 14:29, Monday 06 February 2012 (2162)
BSC8 Closeout - Pictures of Particulate
Pictures are in ResourceSpace:

https://ligoimages.mit.edu/?c=961

Original picture names describe what area the picture is capturing.
H2 SUS
jeffrey.kissel@LIGO.ORG - posted 14:24, Monday 06 February 2012 (2161)
H2 SUS ITMY Compensation Filters Updated
I've updated H2 SUS ITMY's compensation filters such that they contain all compensation for all stage's electronics. The coil driver compensation filters (found in the COILOUTF banks) are arranged in filter modules according to T1100507. The SatAmp whitening compensation filters (found in the OSEMINF) remain in FM1. 

I've also removed any old, erroneous, and/or unused filters in these banks. Note that the "to_nm" filter in FM5 of the OSEMINF banks is a calibration filter for the OSEM sensors (just a gain of ~40 nm/ct), but is untested and should not yet be used.

Details
----------------

The new filter file, 

/opt/rtcds/lho/h2/chans/H2SUSITMY.txt

has been copied over to the userapps repo,

/opt/rtcds/lho/h2/userapps/release/sus/h2/filterfiles/


Because the updated coil driver compensation scheme involves different filter modules than the previous scheme, I've also updated the burt snapshot files,

/opt/rtcds/lho/h2/userapps/release/sus/h2/burtfiles/h2susitmy_damped.snap
/opt/rtcds/lho/h2/userapps/release/sus/h2/burtfiles/h2susitmy_safe.snap

capturing them from the autoBurt.req file found in 

/opt/rtcds/lho/h2/target/h2susitmy/h2susitmyepics/
H2 SEI
hugh.radkins@LIGO.ORG - posted 17:04, Friday 03 February 2012 - last comment - 11:11, Tuesday 07 February 2012(2150)
H2 ITMY (BSC8) SEI State post chamber close-up
The BSC8 HEPI was placed on the fixed stops during the Dome install as the crew can't help but stepping on the Crossbeams.  Once the Dome bolts had been torqued, I suspended HEPI again and read dial indicators for a final delta from last alignment time.

Of note, the before & after dial indicator readings captures the ACB swung back and in place and I saw a 2mil(.002") lower reading to the west while the ACB had a little more leverage on the system--may be within the noise of DI reading and robustness.

Anyway, post final alignment numbers on Jan 19:
Level--There is a 5mil tilt down on the northside.  Our Dial Indicators are essentially at the Support Tubes so I put this tilt in the small category: 0.005"÷60"=80µrads
Position: I see a <6mil shift to the South & <10mil shift West.
Rotation: The dial indicators imply a CW (from above) of no more than 60µrads.  This is worse case as the SE corner shifted South 9mils and the NW corner shift South 1mil.  Averages would reduce the rotation amount.

As this is a close out, I've attached 17 pages of my log book mostly showing dial indicator readings and elevation surveys while we adjust to IAS requests and install and center HEPI Actuators.  I know it is a bit messy but it is a logbook.  If you need clarification just ask.  A couple notes:
DI readings are in .001"(mils).
Corner 1 is NE, 2 is NW, 3 is SW & 4 is SE---This is different from LLO established pier numbering.  I'll try to conform to this in the future.
V T & L corresponds to vertical, Transverse(N-S), & Longitudinal(E-W)
Non-image files attached to this report
Comments related to this report
hugh.radkins@LIGO.ORG - 11:11, Tuesday 07 February 2012 (2170)
Due to the stellar performance of an assembly tech, the final numbers I report here are actually with the Vertical Actuators locked down.  See a subsequent report on Tuesday 7 Feb that reports final floating position.
H1 SEI
greg.grabeel@LIGO.ORG - posted 12:02, Friday 03 February 2012 - last comment - 16:50, Tuesday 07 February 2012(2144)
HAM3 HEPI Install
Greg G. Jim W. Scott L. Ed
	HAM 3 now has the housings and crossbeams installed. We used the spacers between the base clamp and the crossbeam this time and it worked really well, much better on the clearances. So well that HAM 2 should probably be retro-fitted with them.
Images attached to this report
Comments related to this report
hugh.radkins@LIGO.ORG - 16:50, Tuesday 07 February 2012 (2178)
We (Apollo Scott, Devil Ed & Myself) retrofitted the HAM2 with the Clamp Spacers to raise the foot in the housing.
H2 SUS
jeffrey.kissel@LIGO.ORG - posted 08:25, Tuesday 31 January 2012 - last comment - 15:32, Monday 06 February 2012(2109)
Update on SUS Sign Conventions and Status
Earlier this month, we had made a complete assessment of all aLIGO SUS signs and flips across suspension types (see T1200015) and currently functional builds of those types (see SignStatus_120111.pdf). 

In doing so we identified:

- Some suspensions had a few of their magnets flipped
- The BSFMs had some mistakes in their Basis Transformation Matrices
- Some suspensions had there OSEMINF sat-amp compensation filters defined with more poles than zeros
 

For the most part, we have now rectified these problems. I attach a new assessment. The remaining action items are

- Fix H2 ITMY M0's F2 and F3 magnet sign; to fix when we swap out for real ITM Optic
- Figure out what's wrong with X2 PR3's SD OSEM; currently under investigation.
 
Non-image files attached to this report
Comments related to this report
jeffrey.kissel@LIGO.ORG - 15:32, Monday 06 February 2012 (2163)
In regards to the issue with PR3's SD OSEM: 

Because of the arrangement and tight quarters in HAM2, it has been decided (RODA pending!) that some suspensions have their OSEMs Sensor/Coils over on "opposite side" (as opposed to the "side"), i.e. -Trans side of the suspension -- see E1100109 for which is which. It turns out PR3 is one of those suspensions. 

We therefore expect the magnet polarity to be [N] not [S], which means the COILOUTF gain should be [+] not [-]. Once this COILOUTF gain was flipped, the Transverse damping loop closed and was stable, just the like the rest of the DOFs. Mystery solved!

*achoo!*
Displaying reports 86161-86180 of 88268.Go to page Start 4305 4306 4307 4308 4309 4310 4311 4312 4313 End