Witness plates, which are 4" diam. silicon wafers, were installed in BSC8 and nearby beam tubes.  The first two attached images show the installation as of Feb. 1, and as installed on Feb. 2.  Locations match, but the second images includes the detail, that may or may not effect the results, that a witness plate was broken and replaced in one location.

Location for witness plates were chosen to give information about migration of particulate from beam tubes to the BSC8 chamber.

Additionally, I chose locations to look at specific areas of interest.
1) both sides of the bellows in the Y arm beam tube (West) and the beam tube that is on the North side of the chamber - (bellows effect on particulate migration)
2) gate valves - in North beam tube and East beam tube - (gate valve effect on particulate)
3) directly under the gap between the ACB and ITMY - (to measure what particulate is falling in front of the optic)
4) directly in the center of the chamber - requested by Jodi for ICC - (to measure overall BSC8 particulate)


I've chosen to aLog witness plate info under LHO, VE, and I've included the specific chamber in the title, i.e.

Title -> "specific chamber"
Section -> LHO
Task -> VE

I've also attached two in-chamber photos of witness plates placed on Feb. 1 - North Beam Tube and East Beam Tube.
Images attached to this report
H2 TCS
cheryl.vorvick@LIGO.ORG - posted 14:06, Monday 06 February 2012 (2160)
BSC8 TCS Ring Heater Pictures
One image attached here, and the rest found in ResourceSpace.

https://ligoimages.mit.edu/?c=959
Images attached to this report
H2 SUS
cheryl.vorvick@LIGO.ORG - posted 14:02, Monday 06 February 2012 (2159)
BSC8 SUS Cabling Pictures:
One image attached here, and the rest found in Resource Space:

https://ligoimages.mit.edu/?c=958
Images attached to this report
Logbook Admin Bug
jonathan.berliner@LIGO.ORG - posted 11:40, Monday 06 February 2012 (2155)
aLIGO Wiki / MoinMoinWiki Bug: Don't Click Through Links on Preview Pages

After saving a new version of a wiki page, you see the new version of the page with a message at the top that says:

Thank you for your changes. Your attention to detail is appreciated.

It is important to click Clear message underneath this message. If not, and you click through a link on the Wiki, you can't backtrack to the wiki page, lest you arrive at a preview page which often leads to either errors or resubmit requests.

For my instance in the Pcal wiki, I finish editing the wiki and arrive at this page:

https://awiki.ligo-wa.caltech.edu/aLIGO/pcalWiki#preview

If I click through a link and come back, I get popups.

But if I go through the normal wiki page:

https://awiki.ligo-wa.caltech.edu/aLIGO/pcalWiki

...everything works as expected.

H2 CDS
james.batch@LIGO.ORG - posted 10:54, Monday 06 February 2012 (2154)
Mac OS X (iMac Workstations) nds2-client changed
The default nds2-client software for Mac OS X workstations for H2 has been changed to use nds2-client-0.8.2.  Users of Matlab should execute matlab from a terminal window rather than clicking on the matlab icon in order to get the environment set up properly.

Note that there are a few machines (end Y, psl enclosure) that have not been configured to run matlab from the command line yet.  This will be done on a normal Tuesday maintenance schedule.
H2 DAQ
david.barker@LIGO.ORG - posted 08:49, Monday 06 February 2012 (2152)
h2fw1 set to partial mode while LDAS rebuild the QFS file system

Following the test whereby h2fw0 and h2fw1 had their QFS file systems switched: the Sataboy QFS in the LDAS server room continued to have problems. We have decided to rebuild the /ldas-h2-frames file system. Since h2fw1 is currently writing to this system, I have put h2fw1 into partial mode. It is running, but not writing any frames at all. The /ldas-h2-frames file system has been unmounted from h2fw1.

I've mounted the /cds-h2-frames file system to both NDS machines during the rebuild and repopulation.

LHO General
patrick.thomas@LIGO.ORG - posted 17:20, Friday 03 February 2012 (2151)
plots of dust counts
Attached are plots of dust counts > .5 microns.
Non-image files attached to this report
H2 SEI
hugh.radkins@LIGO.ORG - posted 17:04, Friday 03 February 2012 - last comment - 11:11, Tuesday 07 February 2012(2150)
H2 ITMY (BSC8) SEI State post chamber close-up
The BSC8 HEPI was placed on the fixed stops during the Dome install as the crew can't help but stepping on the Crossbeams.  Once the Dome bolts had been torqued, I suspended HEPI again and read dial indicators for a final delta from last alignment time.

Of note, the before & after dial indicator readings captures the ACB swung back and in place and I saw a 2mil(.002") lower reading to the west while the ACB had a little more leverage on the system--may be within the noise of DI reading and robustness.

Anyway, post final alignment numbers on Jan 19:
Level--There is a 5mil tilt down on the northside.  Our Dial Indicators are essentially at the Support Tubes so I put this tilt in the small category: 0.005"÷60"=80µrads
Position: I see a <6mil shift to the South & <10mil shift West.
Rotation: The dial indicators imply a CW (from above) of no more than 60µrads.  This is worse case as the SE corner shifted South 9mils and the NW corner shift South 1mil.  Averages would reduce the rotation amount.

As this is a close out, I've attached 17 pages of my log book mostly showing dial indicator readings and elevation surveys while we adjust to IAS requests and install and center HEPI Actuators.  I know it is a bit messy but it is a logbook.  If you need clarification just ask.  A couple notes:
DI readings are in .001"(mils).
Corner 1 is NE, 2 is NW, 3 is SW & 4 is SE---This is different from LLO established pier numbering.  I'll try to conform to this in the future.
V T & L corresponds to vertical, Transverse(N-S), & Longitudinal(E-W)
Non-image files attached to this report
Comments related to this report
hugh.radkins@LIGO.ORG - 11:11, Tuesday 07 February 2012 (2170)
Due to the stellar performance of an assembly tech, the final numbers I report here are actually with the Vertical Actuators locked down.  See a subsequent report on Tuesday 7 Feb that reports final floating position.
H2 SEI
hugh.radkins@LIGO.ORG - posted 15:52, Friday 03 February 2012 (2149)
ETMY ISI has Keel Ballast Mass (on Test Stand)
Jim & Corey (I helped a little) put the 600lbs on top of the H2 ETMY ISI Keel.  We passed the Keel Mass components (50lbs each) from the floor to the man on a four foot ladder.  In turn the mass was then passed to the man (Jim) standing on the Test Stand.  The mass was placed as per D1000897-v2.  This should put us very close to balanced when the mass is replaced after Cartridge install.
H2 SUS
jeffrey.garcia@LIGO.ORG - posted 15:11, Friday 03 February 2012 (2147)
ETMY R0, L1, L2 Open Light counts
ETMY R0, L1, L2 Open Light counts, offsets, and normalising gain values.  Offsets are calculated by dividing the open light counts by two and multiplied by (-1).  The gain values are calculated such that the open light counts are normalised to 30,000cts.
-----------------------------------------------------------
R0 
controls@cdsws1:~ 0$ tdsavg 30 H2:SUS-ETMY_R0_OSEMINF_F1_IN1 H2:SUS-ETMY_R0_OSEMINF_F2_IN1 H2:SUS-ETMY_R0_OSEMINF_F3_IN1 H2:SUS-ETMY_R0_OSEMINF_LF_IN1 H2:SUS-ETMY_R0_OSEMINF_RT_IN1 H2:SUS-ETMY_R0_OSEMINF_SD_IN1
29408.9
26594.2
28718
28591
27628.8
29841.9

OSEMINF OFFSETS:
F1 = -14705
F2 = -13297
F3 = -14359
LF = -14296
RT = -13815
SD = -14921

OSEMINF GAINS:
F1 = 1.020
F2 = 1.128
F3 = 1.045
LF = 1.049
RT = 1.086
SD = 1.005
-------------------------------

L1
tdsavg 30 H2:SUS-ETMY_L1_OSEMINF_UL_IN1 H2:SUS-ETMY_L1_OSEMINF_UR_IN1 H2:SUS-ETMY_L1_OSEMINF_LL_IN1 H2:SUS-ETMY_L1_OSEMINF_LR_IN1
30801.6
26947.8
31350.3
32767

OSEMINF OFFSETS:
UL = -15401
UR = -13474
LL = -15675
LR = -16384

OSEMINF GAINS:
UL = 0.974
UR = 1.113
LL = 0.957
LR = 0.916
------------------------------

L2
controls@cdsws1:~ 0$ tdsavg 30 H2:SUS-ETMY_L2_OSEMINF_UL_IN1 H2:SUS-ETMY_L2_OSEMINF_UR_IN1 H2:SUS-ETMY_L2_OSEMINF_LL_IN1 H2:SUS-ETMY_L2_OSEMINF_LR_IN1
23679.1
23181.5
26177.6
23786

OSEMINF OFFSETS:
UL = -11840
UR = -11591
LL = -13089
LR = -11893

OSEMINF GAINS:
UL = 1.267
UR = 1.294
LL = 1.146
LR = 1.261
H1 PSL
michael.rodruck@LIGO.ORG - posted 14:53, Friday 03 February 2012 (2148)
H1 PSL installation

Insulation work is finished. Next week the interior drywall will be attached, roof plywood installed, and feedthrus drilled.

Images attached to this report
H2 SUS
betsy.weaver@LIGO.ORG - posted 14:06, Friday 03 February 2012 - last comment - 12:36, Monday 06 February 2012(2146)
ETMy-to-ISI Alignment
This afternoon, after a quick consult between IAS/SUS (Dennis, Calum, Hugh, Gerardo, Travis, Doug, Jason, me), it was decided that we would proceed with translating the QUAD to bring the longitudinal measurement back into tolerance.  So, we will mobilize to push the suspension ~4mm towards the corner station.  Doug has confirmed that on Monday (and probably Tuesday) IAS/SUS together will:

- fix pitch R0
- translate QUAD longitudinally, monitoring yaw, x, y

 --Need to insert possible "fix" to R0 roll/side shift if indeed we need to.  Norna is checking on tolerances of these DOFs.

- make IAS gap measurement
- Adjust R0 to fix gap and yaw if needed.

OSEM general health has been checked, and all open light voltages have been measured and set.
Comments related to this report
betsy.weaver@LIGO.ORG - 12:32, Monday 06 February 2012 (2156)
Shortly after my prompt alog, Dennis emailed the following:
>
Betsy et. al.,
I have discussed the 4mm longitudinal position error with Peter Fritschel. Peter and I both recall that the tolerance for the arm cavity length is more like centimeters. (The +/- 3 mm position may apply to the recycling cavity lengths.) Given this fact plus a possible change in longitudinal position related to the move into the WBSC6 chamber, we do not think it is worthwhile to correct this 4 mm positional error on the test stand.
Once the cartridge is installed into WBSC6, a new IAS measurement of the longitudinal positional error will be made. It is likely that this error will be within the static correction range for HEPI, or at the very least well within the true allowable arm cavity length tolerance.

Dennis Coyne
>
The longitudinal position tolerance can be relaxed for all arms, not just the H2 Y-arm for the ALS test.

Dennis Coyne


betsy.weaver@LIGO.ORG - 12:34, Monday 06 February 2012 (2157)
Further, we solicited for roll and side-shift tolerances which need to be fixted, and received the following email from Ken Strain:

Hi,

a roll error mixes the coordinates, a transverse error of a few mm 
has little effect on the force (as the pattern still faces the TM), 
but the resulting torque changes a little.
Due to the large ratio between the radius of the mirror an the ESD 
gap, and the relatively benign nature of the changes in torque, the 
effects are very small compared to the permitted variation in 
force/torque among the 4 quadrants due to relative pitch and yaw 
wedge angles (between TM and RM).
With errors described, of order 2mm, I can't see any consequences 
worse than (or even comparable to) those that have already been 
permitted.
Ken
betsy.weaver@LIGO.ORG - 12:36, Monday 06 February 2012 (2158)
While the emails above appear to clear the plate of many adjustments, we are currently working on the suspension to fix the yaw of both chains and height of the reaction chain.  
H2 TCS
cheryl.vorvick@LIGO.ORG - posted 13:02, Friday 03 February 2012 (2145)
H2 TCS Steering Mirror Mount Fit Check in BSC8:
On Monday, 1/30, Greg and I installed the H2 steering mirror mounting hardware in BSC8.  We found that mounting it on the bottom 3 holes of the BSC flanges, as intended, made the mirror hardware sit on the chamber floor planks.  We also found that the pivot rod,while just long enough to span the chamber and sit in it's mounts at each end, was short enough to allow it to shift and fall out of the mount.  Black marks also came off of Greg's gloves when he installed the viton damping pads.

On Tuesday, 1/31, issues with the install on Monday led me to decide to remove the hardware.  Greg and Thomas worked in the chamber removing the hardware.  They also used IPA and poly wipes to clean the two flanges that came into contact with the viton pads.
H1 SEI
greg.grabeel@LIGO.ORG - posted 12:02, Friday 03 February 2012 - last comment - 16:50, Tuesday 07 February 2012(2144)
HAM3 HEPI Install
Greg G. Jim W. Scott L. Ed
	HAM 3 now has the housings and crossbeams installed. We used the spacers between the base clamp and the crossbeam this time and it worked really well, much better on the clearances. So well that HAM 2 should probably be retro-fitted with them.
Images attached to this report
Comments related to this report
hugh.radkins@LIGO.ORG - 16:50, Tuesday 07 February 2012 (2178)
We (Apollo Scott, Devil Ed & Myself) retrofitted the HAM2 with the Clamp Spacers to raise the foot in the housing.
LHO General
patrick.thomas@LIGO.ORG - posted 18:46, Thursday 02 February 2012 (2143)
plots of dust counts
Attached are plots of dust counts > .5 microns for today and yesterday. I have included a plot of H0:PEM-LVEA_DST15_MODE to show when the dust monitor at location 15 in the LVEA (in the clean room over BSC8) was disconnected today (the cable came loose).
Non-image files attached to this report
LHO General
corey.gray@LIGO.ORG - posted 16:00, Thursday 02 February 2012 (2141)
Ops Shift Summary

David Jones was on the schedule today, but he needed to do work down at the EY.  Thomas covered the morning, and I covered the rest of the day. 

H2 AOS
keita.kawabe@LIGO.ORG - posted 15:58, Thursday 02 February 2012 (2142)
TMS transport preparation (DavidJ, DanH, Keita)

Today we detatched the telescope/ISC table from the cube, and put the tele/table on a small work table in the EY lab. The tele/table is not that stable, so the Genie is still supporting it.

Tomorrow we'll pick up the 5-axis thing from the VEA, mount that on another Genie, and detatch the cube. It seems that the actual transport will be some time next week.

Note to self:

  1. We dropped one vent washer for 1/4-20 bolt of the wire clamp on the floor. Need to find another one.
  2. It was very hard to detach wire clamps because the space was tight. It will become worse once we're next to the ERM under the test stand.
  3. Not enough garbs at the end station. Will have to bring some for Keita and Dan.
  4. Whenever you have to screw/unscrew something over the optics (i.e. when detaching the vertical protection bars for the ISC table), you need to protect the optics from metal dusts as well as tools and screws by making a foil tray (don't forget to double-fold the edge). I can already see that the back side of the periscope mirror has some metal powders.
Images attached to this report
Displaying reports 86181-86200 of 88268.Go to page Start 4306 4307 4308 4309 4310 4311 4312 4313 4314 End