Displaying reports 86581-86600 of 88222.Go to page Start 4326 4327 4328 4329 4330 4331 4332 4333 4334 End
Reports until 15:28, Thursday 10 November 2011
X1 SUS
jeffrey.garcia@LIGO.ORG - posted 15:28, Thursday 10 November 2011 - last comment - 15:34, Thursday 10 November 2011(1685)
QUAD 04 Diagonalization for R0 Yaw DoF
QUAD 04 BUILD 02

The Yaw DoF Diagonalization measurements for the R0 mass on the latest QUAD build were run yesterday and are attached below.  The measurement was sine wave excitation at 1.3Hz with a 100-ct amplitude. The "F1" and "F2" OSEMs contribute to the "Yaw" DoF.  The "F1" and "SD" isolation is at about ~28-30dB below the "Yaw" OSEMs.  The other two OSEMs are isolated well below 30dB from "Yaw".  These results indicate good isolation of the "Yaw" DoF on the R0 mass.
Non-image files attached to this report
Comments related to this report
jeffrey.garcia@LIGO.ORG - 15:34, Thursday 10 November 2011 (1702)
This post is for measurements taken on 11/09/2011 for QUAD 04 BUILD 02.  I attempted to retroactively change the subject line of the original post to include this QUAD's build number, but the aLog time-stamped the edited post at the edit time. These measurements are before Jeff B. and Andres R.'s adjustments on 11/10/2011 to QUAD 04 to correct Pitch errors.  The subsequent measurements beginning on 11/10/2011 will be for QUAD 04 BUILD 03.
H2 SUS
jeffrey.kissel@LIGO.ORG - posted 15:19, Thursday 10 November 2011 (1701)
Comparing H2SUSFMY to X1SUSBSFM01 (The Same Suspension)
So, following up a little further on Jeff and my diagnosis of H2 SUS FMY (the suspension formerly known as X1 SUS BSFM01), I attach a comparison between the data taken on Tuesday (111108, in Black) vs. the last data taken before it was transported over to the LVEA (110823, in Orange).

A few of my concerns are reduced to "don't worry about it's" immediately:
- In comparing model vs. measurement, lower frequencies on high frequency modes in T, V, and R are expected -- they match this suspension's previous measurements.
- Though the highest frequency Y mode discrepancy is a measurement resolution issue. The 110823 measurement was taken at a 0.01 Hz BW across the 0.01 - 50 Hz band in DTT, where the 111108 measurement was taken with a 0.5 Hz resolution in the 0.5 to 15 Hz band. We'll fix this for future iterations. My guess is that the resonance is just fine.

However, the mysteries that still remain are:
- What's that bump at 0.65 Hz in L?
- What's the rubbing 'causing the lowest Pitch DOF modes to be lossy / invisible?

---------
Plots produced by 
{susSvnHome}/SusSVN/trunk/BSFM/Common/MatlabTools/plotallbsfm_tfs.m

and should be easily adaptable to future measurements by just adding information to measList and defining which to plot in useMeasts. Note that it relies on .mat files that have been produced by running
{susSvnHome}/SusSVN/trunk/BSFM/Common/MatlabTools/plotBSFM_dtttfs.m
or
{susSvnHome}/SusSVN/trunk/BSFM/Common/MatlabTools/plotBSFM_matlabtfs.m
with saveData = true. 
Non-image files attached to this report
Logbook Admin Feature Requests
jeffrey.kissel@LIGO.ORG - posted 14:35, Thursday 10 November 2011 (1699)
One should have the ability to add multiple sections or tasks
As mentioned in Hugh's aLOG entry (though not as logbook admin), one should have the ability to assign multiple tasks to an entry, as some may pertain to more than one subsystem or task (e.g. his entry about feedthroughs).
Logbook Admin Feature Requests
jeffrey.kissel@LIGO.ORG - posted 14:32, Thursday 10 November 2011 - last comment - 17:23, Tuesday 13 December 2011(1698)
Adding a comment should by default have the same Section and Task as main entry
Adding a comment should by default have the same section and task as main entry.
Comments related to this report
jonathan.hanks@LIGO.ORG - 17:23, Tuesday 13 December 2011 (1902)
Jeff,

This is implemented in test test aLOG.  It will be moved to production in the next few days.
Logbook Admin Bug
jeffrey.kissel@LIGO.ORG - posted 14:31, Thursday 10 November 2011 - last comment - 17:24, Tuesday 13 December 2011(1697)
Cannot Edit Comments after commit
While continuing to be logged in, after posting a comment, one should be able to edit comments that you've written in a similar fashion as the main entry.
Comments related to this report
jonathan.hanks@LIGO.ORG - 17:24, Tuesday 13 December 2011 (1903)
Jeff,

This is implemented in test test aLOG.  It will be moved to production in the next few days.
LHO General
patrick.thomas@LIGO.ORG - posted 10:10, Thursday 10 November 2011 (1694)
dust monitor at mid X
The pump in the dust monitor at mid X (S/N 980700963) appears to have failed. I have removed this dust monitor from mid X.
H2 SUS
betsy.weaver@LIGO.ORG - posted 22:08, Wednesday 09 November 2011 (1692)
ITMy monolithic work
Today, Travis and I hung the ITMy monolithic lower chain in a triple.  Jason can fill in the numbers more completely, but we reconfirmed that the pitch error between the test mass and PUM was 1-2mRad (single pendulum hang).  The PUM to UIM differential pitch was ~5mRAD (double hang) and there was a pretty serious mis-pitch on the UIM when hung in a triple from the triple hang tooling.  We made one round of adjusting masses on the UIM, but have more work to do there tomorrow.
H2 SUS
jeffrey.garcia@LIGO.ORG - posted 19:56, Wednesday 09 November 2011 - last comment - 14:28, Thursday 10 November 2011(1691)
H2 FMY M1 Transfer Functions
The attached plots are the results of open-loop transfer function measurements for the M1 stage of H2 FMY. The measurements are open-loop from the "H2:SUS-FMY_M1_TEST_*DOF*_EXC" channels to the "H2:SUS-FMY_M1_DAMP_*DOF*_IN1_DQ" channels. Results agree quite nicely with the model. There might be a lower signal-to-noise ration for the really low frequencies (See "L","P",Y" below 0.5Hz), so further measurements with higher drive amplitude in this band might be desirable. Scripts, data, and plots are in the SUS SVN.

Excitation and Data retrieval script:
'~/SusSVN/sus/trunk/BSFM/H2/FMY/SAGM1/Scripts/collect_TF_H2FMY_M1_allDoFs_0p05to50Hz.m'

Data .mat file:
'~/SusSVN/sus/trunk/BSFM/H2/FMY/SAGM1/Data/111108_H2FMY_0p01to50hz_all_DoFs_5Kcts_highres.mat'

Plotting script:
'~/SusSVN/sus/trunk/BSFM/Common/MatlabTools/plotBSFM_matlabtfs.m'

Plots (individual and combined):
'~/SusSVN/sus/trunk/BSFM/H2/FMY/SAGM1/Results/'
 

Non-image files attached to this report
Comments related to this report
jeffrey.kissel@LIGO.ORG - 14:18, Thursday 10 November 2011 (1695)
Here's the remaining degrees of freedom, and I've fixed a big in the x ticks, such that they're on powers of 10 (instead of 0.5, 5, 50, etc).

Initial investigation comments:
We don't understand the blip at 0.65 Hz in Longitudinal. It doesn't appear in any other degree of freedom, and especially not in the likely suspect of Pitch. (Though there is some evidence for excess coupling in the L to P transfer function -- see page 10).

The higher Vert, Trans, and Roll modes are lower in frequency than the model. Not really a point for concern just yet, we'll need to compare against (i.e. put on the same plot) the 110823 measuremnt (in progress).

The lowest modes in the Pitch TF are not as "Q"-ey as we've seen.

The highest Yaw mode is also not as "Q"-ey as has been seen. 

My guess is there's something rubbing, 'causing the reduced Q's of the P and Y modes, and also cause the weird blip in L.

More analysis to come!!
Non-image files attached to this comment
jeffrey.kissel@LIGO.ORG - 14:28, Thursday 10 November 2011 (1696)
Also, I've commited and updated the changes to 
plotBSFM_matlabtfs.m
that merge all plots produced, and fixed the axes bugs. Update to rev 1548
LHO General
patrick.thomas@LIGO.ORG - posted 18:43, Wednesday 09 November 2011 (1690)
plots of dust counts
Attached are plots of dust counts > .5 microns. Channels for LVEA Location 11 were added to the frames this afternoon.
Non-image files attached to this report
LHO General
jodi.fauver@LIGO.ORG - posted 18:01, Wednesday 09 November 2011 (1689)
West Bay Clean Up
Since the Apollo crew got the large shelving units set up in the West Bay of the LVEA, we started with a little clean up today so you will notice a few changes. There will be more alterations as we prepare to receive more beamtube parts, get ready for the BSC-8 cartridge install, and clear out the area around the H-1 PSL enclosure.
H2 FMP
jodi.fauver@LIGO.ORG - posted 17:53, Wednesday 09 November 2011 (1688)
BSC-4/HAM-9 ICC
FTIR results from BSC-4 came in this afternoon. Although there were three "hot-spots" among the pre-work samples, all three cleaned up nicely (at or below detectable)after brushing and wipe down (and that includes the "green goopie"). Please see actual reports attached.
Non-image files attached to this report
H2 FMP
jodi.fauver@LIGO.ORG - posted 17:46, Wednesday 09 November 2011 - last comment - 18:55, Thursday 10 November 2011(1687)
HAM-11 ICC
The north and south doors blanks were removed from the chamber and the O-ring protectors were installed. Everything is ready to start brushing tomorrow.
Comments related to this report
jodi.fauver@LIGO.ORG - 18:55, Thursday 10 November 2011 (1711)
I just noticed that I had posted this as HAM-11 ICC (which is a correct iLIGO chamber number). It should really be HAM-12 and will be hereafter.
LHO VE
kyle.ryan@LIGO.ORG - posted 16:53, Wednesday 09 November 2011 (1686)
Shut down CS purge air compressor (Kobelco) for Squeezer "quiet time"

Note: ICC work is taking place in HAM11 and HAM12 which are not using purge air.  BSC4, HAM9 and HAM10 are vented but are buttoned up and without purge flow.
H2 PSL
david.barker@LIGO.ORG - posted 08:59, Wednesday 09 November 2011 (1684)
H2 PSL install, computing and networking summary

Summary of H2 PSL install over past few months; computing and networking components:

The following H2 PSL items have been temporarily installed in the LVEA adjacent to the enclosure:

The following units have been installed in their final locations

The H2PSL LAN is being broadcasted in the LVEA  to permit wifi laptop operations inside of the enclosure.

H2 DAQ
david.barker@LIGO.ORG - posted 08:45, Wednesday 09 November 2011 (1683)
Tue maintenance summary, 8th Nov 2011

Dan and Dave:

powered down h2ldasgw0 to investigate the frequent crashes of h2fw0 and associated QFS errors on the ldas gateway. We redistributed the fiberchan cards between two pci-e risers (before they were both on the same riser). Dan did a qfs fsck on the /frames file system as well. Although a new error was reported on h2ldasgw0 on startup, h2fw0 has now ran for 19hours with no crash (before it would not run for more than 4 hours). We'll get more runtime info before making a decision to swap out hardware.

Cyrus, Jim and Dave:

relocated the "GC" CDS servers from the MSR to the computer users room as part of the prep work for the MSR shutdown. We moved the machines

These are all on the GC network (sugarloaf is also on the old 10.1 network, which Cyrus added to the CUR switch).

H2 SUS
betsy.weaver@LIGO.ORG - posted 13:33, Friday 04 November 2011 - last comment - 22:11, Wednesday 09 November 2011(1665)
ITMy monolithic work
This morning, Giles, Travis, Mark, and Jason measured modes of the single pendulum monolithic:

Bounce = 6.7 Hz
Longitudinal/Transverse = 6.66 Hz
Pitch = 1.1 Hz
Yaw = 1.1 Hz

All as expected.

Roll and violin measurements to take place this afternoon.
Comments related to this report
betsy.weaver@LIGO.ORG - 22:11, Wednesday 09 November 2011 (1693)
TYPO on the Longitudinal/transverse - it should actually be 0.66 Hz.
Logbook Admin Bug
jeffrey.kissel@LIGO.ORG - posted 10:14, Wednesday 05 October 2011 - last comment - 17:25, Tuesday 13 December 2011(1509)
Comments don't show up in search results
Comments do not show up as results of search queries for them (I've tested by searching for entry ID #, author name, and keyword search).
Comments related to this report
jameson.rollins@LIGO.ORG - 14:44, Thursday 10 November 2011 (1700)

I agree that this is a pretty bad bug.

jonathan.hanks@LIGO.ORG - 17:15, Thursday 10 November 2011 (1705)
I'll work on that after the NSF review.
jonathan.hanks@LIGO.ORG - 17:25, Tuesday 13 December 2011 (1904)
This is implemented in test test aLOG.  It will be moved to production in the next few days.
Displaying reports 86581-86600 of 88222.Go to page Start 4326 4327 4328 4329 4330 4331 4332 4333 4334 End