(Jeff B., Craig, Virginio) Finished the assembly of the wires+clamps to suspend the payload. Wires are now all attached to the suspension. Finally, we found the dummy payload still sitting inside a wooden crate in the Y End Station Unfortunately, it hasn't been cleaned yet. Maybe, we can class B clean only the parts that go into direct contact with the wires' clamps. This will require a small oven for the baking instead a big one which is at least 34" deep, and maybe this will save us some time. Virginio
BBland, GMoreno Today, we went to the bonding lab intending to glue the TCP SST prisms to the glass barrel. However, because this requires a heat lamp cure very near where there were some FC/PEEK mesh tabs (left over from transport?), we needed to remove them. When I went to pull them off, we immediately noticed that the PEEK mesh was not sunk into the FC enough to get the edge to peel (see picture attached). As well, there some brush strokes outside of the base FC "puddle" which were also not attached to the PEEK mesh, therefore not coming off with the pull. So, we had to reapply the FC around the edge and let it dry (another 8 hours, as per the FC procedure), and abort the prism gluing.
Note, the TCP had this first contact applied by CSIRO, not CIT.
Keita, Sheon The L1 OMC and Lesco Mark III UV lamp (ALOG LLO post) arrived on site at Hanford today. The L1 OMC (large shipping) container remains unopened. The UV lamp box was opened, within contained the module and foot switch, but no flexible lamp-head - perhaps it is within the OMC box? Both are now stored in the OSB Optics Lab.
- Lots of visitors, for SUS, fiber pulling, TMS assembly, and HR program
- Reiboldt working on roof of H2 PSL
- Mount's Lock and Key, Stoneway Electric on site
- Patrick working on dust monitors in the LVEA
- H1 was running (stays locked through Detect) today during Laser Safe operation. Squeezers transitioned to Laser Hazard at ~18:15 to access beam enclosures.
- H1 TCSY flipper M2 alarmed but that's OK, as no laser power is being transmitted
- EY: HEPI pumping ongoing
Taken picture of the TMS ISC table to survey the components already mounted on the table What it is clearly missing are the two periscopes, the glass baffle, the glass beam dump, and some connectors. Picture of the underside of the table should show that all the ballast masses are there The total current weight of the table is 52.5 kg (Keita)
What were missing from the table when the weight of the table was measured 52.5kg, as far as I can tell: 2xHAM connector brackets (in the picture, but they were not there when measured). Beam diverter cable, cable clamps, and a 25pin connector (not yet installed). Total of 9 posts with black glass mount and total of 10 glass plates to be mounted on the posts (total of 10, not 9, because one of the posts will have two plates) (not yet installed). Tiny black glasses behind high reflectors and tiny aluminum holders for them (not installed yet).
And neither of two periscope assemblies (including mirrors) are not included in the weight, as they are not yet installed.
And most importantly, this is H2! H2!!!!!!
(Craig, Virginio) Mount wires from upper blades to suspended mass without any particular issues Tablecloth earthquakes stop screws were at the end of their travel to be able to secure the clamps. We will need to lower the upper blade's tips by about 2 mm to secure completely the clamps to the mass
(Andreas, Jeff B., Craig & Virginio) Modified the jig to string the wire, see pictures Nominal load 146lbs = 66.36kg => used 66 kg (nominal values read on the weights) Wire music steel wire diam 1.1 mm Distance between the aluminum parts the hold the clamps (425 +- 0.3) mm ( see picture) Used two 10 mm spacers to get to 425 mm. This should bring the clamps' distance to 455 mm as shown in drawing https://dcc.ligo.org/cgi-bin/private/DocDB/ShowDocument?docid=63179. We need to design a couple of parts to have a better way string the wires.
The "quadrapuss" cable type (D1000234 - 125") coming from M1 SD and RT was changed from S/N 901 to S/N 903. There was an issue with the readout of the OSEM. The new cable was routed through the same path on the FMY structure, and the readout was confirmed in the medm.
In the interest of time, using good 'ol foton, I've installed the basic electronics compensation and damping filters that we've been using thus far to commission the BSFM/QUAD in the assembly area, since it's basically the same electronics. These include (notation is [zeros:poles], every filter has a gain of 1). - In the M1 OSEMINF banks, compensation for the analog whitening in the Satellite Amplifiers, a [10:0.4] dewhitening filter. - In the M1 COILOUTF banks, compensation for the analog dewhitening of the "acquire" state of the TOP coil driver. a [1:31] anti-dewhitening filter (note, as with the QUAD, there is an additional state [1,1:10,31], but I have not yet installed that filter) - In the M1 DAMP banks, the same simple damping loops that have been inherited from the LASTI QUAD; a differentiator with a cutoff ([0:20,20]), and the 50Hz elliptical filter. Now that these filters are installed, as soon as the M1 BOSEMs are restored to the middle of the range, and properly diagonalized, we *should* be able to close damping loops (though it should be done cautiously at first!!).
Betsy & Co had left H2SUSFMY with it's OSEMs entire backed off from their flags, such that they read "open light" currents. At her request, I've installed the "proper" offsets and gains to compensate for these open light current values (on both M1 and M2), such that the OSEMINF_*OUT channels are nominally 0 when the flags are in the middle of the OSEM's range. Tomorrow, the OSEMs will be physically set to there nominal range using these newly conditioned signals. I don't think all of the M2 BOSEMs are truely open light, as they should register in the (62+/-20)e-6 [A] * 240e3 [V/A] * 2 [V/V] * 2^16 / 40 [ct/V] = (24e3+/-7e3) cts and for example, UL is showing 7e3 counts. When we're confident that the M2 BOSEMs are open, then we should repeat the process detailed below. "How To" Details I measured the open light current using the inputs of the OSEMINF filter banks (i.e. the raw signal just as it comes off the ADC) using tdsavg -- a quick command line tool that takes the average of a channel for a specified duration. The command and results are: controls@cdsws2:~ 0$ tdsavg 30 H2:SUS-FMY_M1_OSEMINF_F1_IN1_DQ H2:SUS-FMY_M1_OSEMINF_F2_IN1_DQ H2:SUS-FMY_M1_OSEMINF_F3_IN1_DQ H2:SUS-FMY_M1_OSEMINF_LF_IN1_DQ H2:SUS-FMY_M1_OSEMINF_RT_IN1_DQ H2:SUS-FMY_M1_OSEMINF_SD_IN1_DQ 28331.1 27269.3 30542 27143.1 28230.5 21085 controls@cdsws2:~ 0$ tdsavg 30 H2:SUS-FMY_M2_OSEMINF_UL_IN1_DQ H2:SUS-FMY_M2_OSEMINF_LL_IN1_DQ H2:SUS-FMY_M2_OSEMINF_UR_IN1_DQ H2:SUS-FMY_M2_OSEMINF_LR_IN1_DQ 7395.21 25831.7 17090.4 22564.3 controls@cdsws2:~ 0$ To calculate the offest for each channel, one divides the above result by 2 and flips the sign. To calculate the gain for each channel, one normalizes the above result to 30000 cts, i.e. (30000 / result) = gain. I installed them by hand. Hence the offsets are controls@cdsws2:~ 134$ tdsread H2:SUS-FMY_M1_OSEMINF_F1_OFFSET H2:SUS-FMY_M1_OSEMINF_F2_OFFSET H2:SUS-FMY_M1_OSEMINF_F3_OFFSET H2:SUS-FMY_M1_OSEMINF_LF_OFFSET H2:SUS-FMY_M1_OSEMINF_RT_OFFSET H2:SUS-FMY_M1_OSEMINF_SD_OFFSET -14165 -13634 -15271 -13571 -14115 -10542 controls@cdsws2:~ 134$ tdsread H2:SUS-FMY_M2_OSEMINF_UL_OFFSET H2:SUS-FMY_M2_OSEMINF_LL_OFFSET H2:SUS-FMY_M2_OSEMINF_UR_OFFSET H2:SUS-FMY_M2_OSEMINF_LR_OFFSET -3697 -12915 -8545 -11282 and the gains are controls@cdsws2:~ 134$ tdsread H2:SUS-FMY_M1_OSEMINF_F1_GAIN H2:SUS-FMY_M1_OSEMINF_F2_GAIN H2:SUS-FMY_M1_OSEMINF_F3_GAIN H2:SUS-FMY_M1_OSEMINF_LF_GAIN H2:SUS-FMY_M1_OSEMINF_RT_GAIN H2:SUS-FMY_M1_OSEMINF_SD_GAIN 1.059 1.1 0.982 1.105 1.063 1.422 controls@cdsws2:~ 134$ tdsread H2:SUS-FMY_M2_OSEMINF_UL_GAIN H2:SUS-FMY_M2_OSEMINF_LL_GAIN H2:SUS-FMY_M2_OSEMINF_UR_GAIN H2:SUS-FMY_M2_OSEMINF_LR_GAIN 4.056 1.161 1.755 1.329
Gas bottle delivery HR workshops Activities listed on the white board: LVEA: PSL diode / chiller room SUS / SEI test squeezer / H1 restore triage clean storage welding setup ICC @ HAM 7,8 HEPI Welding HAM 9 EX: BSC 5 set, pier set MY: oplev test EY: ICC @ BSC 6 RGA @ BSC 10 Transmon assy HEPI Station Run Plots of > .5 micron dust counts attached. I still need to investigate the dust monitor at location 1 in the LVEA (ISCT 4). The dust monitor at location 7 in the LVEA (near the previous location of the H2 PSL racks) dropped out for a while for an unknown reason. Michael R. replaced the fuse, but this did not appear to fix the problem.
Today the ETMY Quad-3 was moved to Y End Station. No problems were encountered during the move.
This afternoon the TMS upper suspension was transported to the Y End Station. It has been mated to the Bosch tubing test stand for final assembly and alignment.
We needed to use full size dog clamps for attaching the suspension frame to the Bosch frame as the top plate was too thick for the low profile ones. Some Wire clamps are in the clean/bake, they'll come out tomorrow. Clean transport box for the suspension structure is still in the EY lab. It will be transported back to the staging building tomorrow.
Today, we suspended the ITMy glass PUM from it's loop - the pitch error was better than the metal hang (!) at ~400 uRad (note, better than ~1 mRad is the spec). Prior to the pitch look, we spent a fair amount of time setting roll correctly. The tolerance for getting the clocking of the mass correct is ~0.25mm which proved a bit difficult to set manually with the mass sitting on TFE caps. We overshot a few times before settling in at having the prism-to-prism height diff off by 0.2mm. We determined that the ergo arm would not have helped us since we had to push the TFE lower stops up for a little loop slack, roll the mass a fraction of a mm, and then release it to hanging for a reading of the pitch with the theodolite, a very iterative process. This would have taken hours with multiple pump-downs of the ergo arm, likely not yielding better results than us doing it "by hand". Since the loop looked good, we proceeded with installing the ITMy test mass into the sus structure. We stole the base from the split rotation tooling and mounted the ITMy LS/LSAT/Weld Trolley on top of it such that the ergo arm legs would fit underneath while installing the optic. The install went well, right through the open ring heater from the back of the LS structure - the ears only have a few mm of clearance with the structure, but it went well with 3 spotters. Pictures to be posted on ReSource Space shortly.
Cyrus working on paging system Filiberto extended the dust monitor power and RS485 lines near the new H2 PSL enclosure. Fire department well testing Electrical inspector on site Ski working on air handler system Activities listed on the white board: LVEA: PSL diode / chiller room SUS / SEI test squeezer / H1 restore triage clean storage welding setup ICC @ HAM 7,8 HEPI Welding HAM 9 EX: BSC 5 set, pier set MY: oplev test EY: ICC @ BSC 6 RGA @ BSC 10 Transmon assy HEPI Station Run Plots of > .5 micron dust counts attached. Note relatively high levels at location 7 (near previous location of H2 electronic racks). The dust monitor at location 1 in the LVEA (ISCT 4) has dropped out. There are also some drop outs in the data for the counts in the LVEA from when Filiberto was working on the system.