Displaying reports 87961-87980 of 88144.Go to page Start 4395 4396 4397 4398 4399 4400 4401 4402 4403 End
Reports until 15:39, Monday 11 October 2010
H2 General
betsy.weaver@LIGO.ORG - posted 15:39, Monday 11 October 2010 - last comment - 09:12, Monday 18 October 2010(203)
QUAD Test Stand
After returning the sat boxes to the rack, M0 F1 was glitchy.  Filiberto reseated the cable at the Sat box which appeared to fix it.  Now hours later, we are aligning the BOSEMs and have found that this signal peggs at ~6k alot.  We have been able to fix it by reseating the cable at the sat box, but this is not working right...
Comments related to this report
betsy.weaver@LIGO.ORG - 10:31, Tuesday 12 October 2010 (204)
M0 F1 still a problem this morning.  Filiberto thinks that the Sat box looks like an OP amp blew again - he's pulling the box again for a trip to the ER, er I mean EE.
betsy.weaver@LIGO.ORG - 16:18, Tuesday 12 October 2010 (205)
Filiberto returned the sat box after another Op Amp swap, but a few hours later we now see bad BOSEM signals in this module...  
betsy.weaver@LIGO.ORG - 11:30, Wednesday 13 October 2010 (206)
Day 5:  Still working on diagnosis of crazy signals from the Sat box 1 (M0 F1, F2, F3, L).
With Filiberto, performed another round of boots to the AA chassis, and bscteststand computer.  No changes so far.  Likely another blown op amp on Sat box 1.

Since we seemed to have changed both satellite boxes and a set of cables (put the new Jay cables in), we might have possibly had more than one problem to diagnose.  We decided to put back in the old cables on a different sat. box and things looked pretty good.  Filiberto is going to fix the blown op amp on the Sat box 1.
betsy.weaver@LIGO.ORG - 15:07, Wednesday 13 October 2010 (208)
After rearranging sat boxes, Richard and Filiberto found 2 that seem to work.  They hauled away those that have issues.  
With the working sets, I finished aligning all 6 M0 Top BOSEMs.  I just have to finish setting them to 50% OLV and then we can start FFTs.
betsy.weaver@LIGO.ORG - 09:12, Monday 18 October 2010 (214)
Betsy,

Here is a summary of the troubleshooting of the Sat units.

Oct 8, 2010
Uninstalled two Satellite units SN320073 and SN320078 from test stand.
SN320078 had two bad channels. CH1 had gain off by ~6dB. Replaced IC103 (OP2177AR) with OP284. Did not have OP2177AR replacement part but has been placed on order (expected arrival date 10-14-2010).  CH3 had output railing high, replaced IC303 with OP284.

SN320073 had CH4 output railing high. replaced IC403 and IC404 with OP284.
Ran test on units per Test Plan T080062 - UK Satellite Amplifier Pre-Preduction Test Plan for transfer functions and voltage readings.

Oct 11, 2010
Reinstalled SN320073 and SN320078 in test stand. Took opportunity to test unit SN3200715. Tested unit per Test Plan T080062 - UK Satellite Amplifier Pre-Production Test Plan. All test results within specs. Reinstalled unit back in test stand.

Oct 12, 2010
While connecting OSEM's Betsy and company found MO F1 signal to be glitchy. This corresponds to unit SN320078 CH1. While trouble shooting, switched cables with another sat unit. When reconnecting cables to original sat unit, CH1 not responding, output ~2.3V. 
Uninstalled SAT unit SN320078 and placed a working unit in its placed. Replaced the "new" cable and installed an older cable on the vacuum side. Connected all four OSEM's and saw a response from all four channels. Disconnected SAT unit and left all four OSEMS connected.

Replaced IC103 with OP284. This IC was one that had been previously replaced. Ran transfer functions on CH1 per Test Procedure T080062. Unit tested good. 
Used spare cable and OSEM SN0011 from Betsy to test connecting and disconnecting osems while sat powered on. Trying to see if the act of plugging and unplugging the OSEM could be causing opamps to go bad.

Oct 13, 2010
Reconnected unit SN320078, knowing that all four OSEMs were connected, we expected to see all four channels come up. Upon powering unit up, all four channels seemed glitchy until CH3 died. All other channels then settled to a good state.

Unit SN320073 also had CH4 fail again. 

Oct 14, 2010
Replaced IC103 (CH1) and IC303 (CH3) on unit SN320078 with OP2177. 
Replaced IC402 and IC404 on CH4 with OP2177.
All opamps that were continually going bad were the OP284. Since they were being used as substitutes until OP2177 arrived. 

Oct 15, 2010
Took readings of OSEMs.

SN #	Our Readings	Stuart's Reading	Symptoms
SN688	55.44		57.6		Working Unit
SN695	61.08		62.67		Glitchy - Case causing short
SN674	48.99		49.51		Low Count
SN697	54		55.37		Working Unit - 29K Count

Data corresponds with Stuart's data. Even OSEM SN674 shows a lower voltage reading that is consistant with the low count reading from MEDM.

Looked at the bad OSEM with the short. The short is coming from the Photodiode Cathode side.
Also, we connected and disconnected various OSEMs and don't seem to be having the issue of blowing up the Opamps. Still not sure how the first set of Opamps went bad.
H2 General
betsy.weaver@LIGO.ORG - posted 11:18, Monday 11 October 2010 (202)
QUAD (BSC) Test Stand Status
After removing them from the stand last Thur, 2 Sat boxes were modified to fix a blown IC chip (OP2177).  Symptoms were that output of IC chip were railing.  Replaced with OP284, while waiting for correct OP2177 which are on order.  Likely the Sat boxes will have to revisit the EE shop when these chips are in later this week.  We will progress with BOSEM alignment and testing until then.
Filiberto reinstalled the 2 sat boxes into the test stand this morning.
X1 SUS
jeffrey.bartlett@LIGO.ORG - posted 16:53, Thursday 07 October 2010 (201)
Beam Splitter Upper Structure
 We completed the test assembly of the Beam Splitter Upper Structure. To ease installation of the Shear Plates we enlarged all but the top two mounting holes to 29/64”.
  
Beam Splitter Upper Structure Assembly Procedures: 

(1). Assemble the Upper Structure Face Plates, Bottom Ring and US Cross Member. Snug the bolts enough to allow a semi-ridge structure, but with enough give to allow some wiggle. This will help to align the Face Plate bolts.
 
(2). Stand the assembled Upper Structure upright on a level surface.
 
(3). Hold one of the Shear Plates to a Face Plate and run in the top two bolts. Lightly snug these bolts, but do not tighten.
 
(4). Run in the remaining bolts so the washer has about a 1 mm gap between the Shear Plate and the Face Plate. Note: Rock the structure from side to side slightly and/or wiggle the Shear Plate to allow alignment of the bolts. When you get to the bottom bolts, it may be necessary to lever up the Shear Plate due to sag.
 
(5). Repeat steps 3 and 4 on the other Shear Plate.
 
(6). When both Shear Plates are mounted, tighten the bolts using a crossing pattern, paying close attention to squaring the Shear Plates to the Face Plates. Make at least two rounds of tightening to ensure the structure does not creep, as the bolts are tightened.
  
(7). When all the Shear Plate bolts are tight, tighten the bolts on the Bottom Ring and US Cross Members.

(8). Remove the Shear Plates and store until the Beam Splitter has been installed in the chamber and aligned. 

This procedure should ensure the Shear Plate to Upper Structure fit is correct for installation. If it is not, you may try slightly loosening the bolts on the Bottom Ring allowing the Structure to “float” into a square alignment. Tighten all bolts as noted above. 
Images attached to this report
H2 General
betsy.weaver@LIGO.ORG - posted 14:31, Thursday 07 October 2010 (199)
Q2 EE work
Syptoms before plugging in any OSEMs - medm actuation verified to be disabled.
OSEM signals strange in 3 of 12 signals (-4k, -31k, -19k, when should be zero).
Fault lights on 3 of 5 sat boxes.

2 of 2 yellow cables tested out ok.  Even unplugged, signals strange.

Powered bscteststand down from work station.  No go.
Powered it down at computer (button)
Powered down Expansion chassis.
Powered on chassis
Powered on bscteststand

Ran startup script

Richard poked around

Powered everything down again
Reseated ADC

More troubleshooting at the rack by Richard/Filberto...
Pulling 2 satellite boxes to take to the EE shop.
H2 General
james.batch@LIGO.ORG - posted 09:31, Wednesday 06 October 2010 - last comment - 18:26, Wednesday 06 October 2010(197)
Change ntp configuration files, sync time on seismic and suspension test stands
After a report form Vincent that the time had drifted enough to make awgstream unusable, I modified the configuration files on seiteststand and workstation for ntp.  

On seiteststand:
1. stop ntpd
2. modify settings in configuration file
3. sync time with ntp server
4. start ntpd

On workstation:
1. stop ntpd
2. Modify settings in configuration file to use seiteststand as time server
3. sync time with seiteststand
4. start ntpd

Checked bscteststand, suswork1, found the time had drifted on these as well.  Modified the configuration files on bscteststand and syswork1 similar to seiteststand, workstation.

Checked times, they are sync'ed again.  Will monitor this, seiteststand was stubborn about being able to connect to the ntp server although bscteststand had no problem.
Comments related to this report
james.batch@LIGO.ORG - 18:26, Wednesday 06 October 2010 (198)
After monitoring the clock performance on the workstation connected to seiteststand all day, I decided to set up a crontab (as root) to run 'ntpdate -b 10.11.0.24' with the output going to /var/log/ntpdate-cron.txt to see if this will keep better time.  Will revisit in the morning.
X1 SEI
hugh.radkins@LIGO.ORG - posted 16:59, Friday 01 October 2010 (196)
LHO HAM ISI Assembly #3 Nears Completion
See images for final positioning work.  Great job JimW EricA MitchR!

Testing will begin on Unit#3 after final instrumentation and cable routing.
Images attached to this report
X1 SUS
betsy.weaver@LIGO.ORG - posted 19:38, Thursday 30 September 2010 (195)
Metal LHO Q2 Hanging and Aligned
Last week we swapped QUADs out on the mechanical test stand.  This never being done before, it took a few days to work the kinks out of maneuvering 4 sections of QUADs simultaneously.  Currently, the Q1 upper structure is in it's case waiting for an N2 purge, while the lower structure is parked in the modified LSAT Top Plates on the "installation Genie".  It's case will not arrive for a few weeks yet.

Q2 was fully hung earlier in the week.  As of today, all 6 DOFs have been adjusted mechanically so we are installing the tablecloth and BOSEMs.  A final tweak to pitch will likely be needed during the OSEM installs over the next day or so.  (Note our alignment is to within a few mRad in pitch with the 5mm gap between chains set with a 5mm spacer.)  The chains are slightly misaligned laterally (side shift) with the barrel of the ReTM set <1mm off the barrel of the TM.  We could adjust this out at the expense of overall height of the Test Mass.  We opted to live with the slight side shift for now.

Q2 has one Top Stage Blade cartridge which is almost out of yaw range in one direction.  The screws are very difficult to adjust under normal circumstances, but one of the outer most blade clamp 3/8-16 is feeling very rough when loosening.  The yaw which is somewhat pinned is the motion of M0 in the counter-clockwise direction as viewed from above.
H2 General
jonathan.hanks@LIGO.ORG - posted 11:52, Monday 27 September 2010 - last comment - 08:11, Tuesday 28 September 2010(193)
aLOG system maintenance tomorrow (Tues 28 Sept 2010)
I will be applying some critical security patches to the aLOG system tomorrow around 8:00am.  The system will require a reboot.  Downtime is estimated to be on the order of 5-10 minutes.

Please remember to save any unfinished entries as a draft prior to 8am pacific tomorrow.
Comments related to this report
jonathan.hanks@LIGO.ORG - 08:11, Tuesday 28 September 2010 (194)
The system has been restarted.  The maintenance work is finished.
H2 General
james.batch@LIGO.ORG - posted 15:57, Friday 24 September 2010 (192)
Add workstation to BSC test stand
Added new Linux workstation to SUS Quad test stand.  It's name is suswork1.

When logged in as user controls, the home directory is the same one as on bscteststand.  You should be able to run programs on suswork1 the same as you would on bscteststand without having to ssh to bscteststand first.  Matlab is installed locally on suswork1.  Adobe Reader is installed, and firefox is set up with the aLIGO LHO Logbook as a bookmark.  Be sure to use your own name for logbook entries!

All /cvs/cds/llo files are visible on suswork1, as are all /apps/Linux files.

Details - 
mounted bscteststand:/cvs, /apps, /opt, and /home/controls to suswork1:/cvs, /apps, /export/opt, and /export/controls.
Made symbolic links from /export/opt to /opt for directories in /export/opt.  
Set up shared library default paths to the same as on bscteststand.
Installed or updated libraries to run gds tools.
Set up suswork1 to ntp sync time from bscteststand.  

Let me know when you find stuff that doesn't work.


X1 SUS
jeffrey.bartlett@LIGO.ORG - posted 13:43, Friday 24 September 2010 (191)
Beam Splitter Lower Structure
We have completed assembly of the first Beam Splitter Lower Structure. No fit, machining, or alignment issues were noted. The main Lower Structure drawing (D080005) calls for eight 1/4-20x0.5 SHCS. However, the EQ Stop Plate (D080008) and the LS-US Bracket (D080011), both require 1/4-20x.05 SHCS and therefore 16 of the 0.5” bolts are required.
Images attached to this report
X1 DTS
david.barker@LIGO.ORG - posted 09:41, Thursday 23 September 2010 (190)
reusing the X2200 in the DTS
Over the past two weeks we have repurposed the three X2200 units
for aligo auxillary system prototyping. From top to bottom the
X2200 are being used for:

top: 10.11.0.70, Cyrus network management tests
middle: 10.11.0.72, Patrick aconlog prototype
bottom: 10.11.0.71, Cyrus second net mgt machine
X1 SEI
jeffrey.garcia@LIGO.ORG - posted 08:01, Thursday 16 September 2010 (189)
Reboot of X1 SEi Test Stand
This morning I noticed some extra testpoints on the GDS Overview medm on the Test Stand even though I was not running measurements or had dataviewer open. I ran Dave B.'s 'system_check' script that checks to see if the processes are running correctly.  There were several errors with processes not running and so I decided to reboot the front end.  Afterwards, the test points cleared and the system_check came up clean.  The workstation linux machine was also running really slowly, so that machine was rebooted as well.
X1 SUS
jeffrey.bartlett@LIGO.ORG - posted 17:13, Wednesday 15 September 2010 (188)
BS Top Stage Cartridge Assembly
We have completed the assembly of the five Beam Splitter Top Stage cartridges, which are undergoing the 100-hour creak bake.  

Assembly Notes:
 
(1). We made the assembly jig out of four sections of aluminum box. For assembly, the end of the Base Plate is secured to the box sections via 1/4-20 SHCS into tapped holes. For blade pull down, the two end sections, bolted to the Base Plate, are dog clamped to the optics table. The remaining two box sections are slid under the Base Plate near the edge of the optics table to support the front half of the assembly. (See photos Assembly Jig and Clamp Down). 
     
(2). When installing Helicoils into the Blade Clamp Bottom ensure the two outer ones are run down to the bottom (the curved side) of the clamp. If not the 1/4-20x 1” mounting bolts will not engage the Helicoil.

(3). The Rotational Bushing can be a tight or loose fit in the Bottom Plate or Blade Clamp Base. If you have to tap or press to set the bushing, install a 1/4-20 SHCS into the bushing and push on the head of the SHCS. Tapping or pressing directly on the phosphors bronze will distort the bushing making it difficult to insert into the other part.
 
(4). If the mounting SHCS for the adjuster assembly do not line up with the slots cut into the Base Plate, loosen the 8-32 SHCS holding the two halves together to allow some free play. Once all five SHCS have been installed, the 8-32s can be tightened back down. This may cause some binding when trying to rotate the adjuster. 

(5). Use 20kg for the blade pull down weight. The assembly book calls for 50kg, which is too much.  
Images attached to this report
X1 SEI
jeffrey.garcia@LIGO.ORG - posted 19:38, Tuesday 14 September 2010 (187)
X1 Test Stand ADC replacement
The General Standards ADC adapter board was replaced today after some investigations by Richard, Hugh, Dave B. and others regarding the flat-lined channels seen this morning by Corey.  The previous General Standards ADC board had a Serial #080421-35.  The replacement board (same model) installed today has a Serial #091102-16.  The channels have been confirmed to be reading and outputting data through dataviewer. 
H2 DAQ
david.barker@LIGO.ORG - posted 15:41, Tuesday 14 September 2010 - last comment - 18:00, Tuesday 14 September 2010(185)
h1 daq raid ready for qfs
the SATABOY finally finished its RAID6 build at 15:00.
Dan noticed that the spare 2TB SATA drive was configured
as a global spare for the 64GB SSD drives as well! So 
we removed it from the global spare pool and added it to
the SATA RAID pool only.

I connected the Sun X4270 (frame writer) fibre channel
cards to the sataboy controllers. There are two FC cards
in the Sun and two controllers, so the connection is:

sun pci-e slot1 to controller 0 (left connector)
sun pci-e slot4 to controller 1 (left connector)

I've handed the system over the DCS for QFS install.

Dave, Greg, Dan
Comments related to this report
dan.moraru@LIGO.ORG - 18:00, Tuesday 14 September 2010 (186)
QFS is installed and configured with a 15.9TB (vs 16.3TB available) partition:

# mount LDAS/DCS filesystems
ln -s /net/dcs/export/ldcg_server/ldcg/opteron_sol10 /ldcg

# install QFS
lofiadm -a /net/dcs/export/mirror/sun/SAM-QFS-5.1/SUN_QFS_5.1.iso
mount -F hsfs -o ro /dev/lofi/1 /mnt
pkgadd -d /mnt/x64/2.10
#The following packages are available:
#  1  SUNWqfsr       Sun QFS Solaris 10 (root)
#                    (i386) 5.1.4,REV=5.10.2010.04.05
#  2  SUNWqfsu       Sun QFS Solaris 10 (usr)
#                    (i386) 5.1.4,REV=5.10.2010.04.05
#  3  SUNWsamfsr     Sun SAM and Sun SAM-QFS software Solaris 10 (root)
#                    (i386) 5.1.4,REV=5.10.2010.04.05
#  4  SUNWsamfsu     Sun SAM and Sun SAM-QFS software Solaris 10 (usr)
#                    (i386) 5.1.4,REV=5.10.2010.04.05
#
#Select package(s) you wish to process (or 'all' to process
#all packages). (default: all) [?,??,q]: 1,2
umount /mnt
lofiadm -d /dev/lofi/1

# add binaries and manpages to $PATH and $MANPATH
cat >> /etc/profile <<_EOF

# set global MANPATH
MANPATH=/usr/share/man
export MANPATH
_EOF
cat >> /.profile <<_EOF
PATH=/opt/SUNWsamfs/sbin:/opt/SUNWsamfs/bin:$PATH
MANPATH=/opt/SUNWsamfs/man:$MANPATH
export PATH MANPATH
_EOF

# disable all file system management
svcadm disable fsmgmt

# patch system
/ldcg/bin/patchreport -i

# update nfs/server svc manifest to enable proper QFS mounting and NFS sharing
svccfg export /network/nfs/server > /var/tmp/server.xml
# edit /var/tmp/server.xml
#      
#        
#      
#+     
#+       
#+     
#      
#        
#      
svccfg validate /var/tmp/server.xml
svcadm disable nfs/server
svccfg delete nfs/server
svccfg import /var/tmp/server.xml
svcadm enable nfs/server

# format disks, relabeling all with EFI labels
#
# initial dtsfw0 configuration:
#       0. c0t0d0 
#          /pci@0,0/pci8086,340c@5/pci1000,3150@0/sd@0,0
#       1. c4t6000402002F45FC666750C9500000000d0 
#          /scsi_vhci/disk@g6000402002f45fc666750c9500000000
#       2. c4t6000402002F45FC666750C9600000000d0 
#          /scsi_vhci/disk@g6000402002f45fc666750c9600000000
#
#
# final dtsfw0 configuration:
#       0. c0t0d0 
#          /pci@0,0/pci8086,340c@5/pci1000,3150@0/sd@0,0
#       1. c4t6000402002F45FC666750C9500000000d0 
#          /scsi_vhci/disk@g6000402002f45fc666750c9500000000
#       2. c4t6000402002F45FC666750C9600000000d0 
#          /scsi_vhci/disk@g6000402002f45fc666750c9600000000
#
# label type may be determined using prtvtoc
# SMI labels list the number of accessible cylinders
# EFI labels list the number of accessible sectors

# create /etc/opt/SUNWsamfs/mcf
#
# daq-h2-frames 300 ma daq-h2-frames -
# /dev/dsk/c4t6000402002F45FC666750C9600000000d0s0 301 mm daq-h2-frames -
# /dev/dsk/c4t6000402002F45FC666750C9500000000d0s0 302 mr daq-h2-frames -
# partitions must be less than 16TB

sammkfs -a 1152 daq-h2-frames
# from sammkfs manpage:
#     Data alignment refers to matching the allocation unit of the
#     RAID controller with the allocation_unit of the file system.
#     A mismatched alignment causes a read-modify-write operation
#     for I/O that is less than the block size.  The optimal
#     alignment formula is as follows:
#
#     allocation_unit = RAID_stripe_width * number_of_data_disks
#
#     For example, if a RAID-5 unit has a total of 8 disks with 1
#     of the 8 being the parity disk, the number of data disks is
#     7.  If the RAID stripe width is 64 kilobytes, then the
#     optimal allocation_unit is 64 * 7 = 448.

# add following to /etc/vfstab
#daq-h2-frames           -       /daq-h2-frames  samfs   -       samfs   -

# create mount point and mount
mkdir /daq-h2-frames
mount /daq-h2-frames

df -h daq-h2-frames
#Filesystem             size   used  avail capacity  Mounted on
#daq-h2-frames           16T   1.1M    16T     1%    /daq-h2-frames
H2 General
corey.gray@LIGO.ORG - posted 07:57, Tuesday 14 September 2010 (184)
GS13 & Displacement Sensors With Zero Inputs
Last night, I was getting ready to run a measurement for Vincent, but before running I happened to check channels and noticed some channels were zero at their inputs.  I went to do a quick check of cable connections, and they looked connected at the Feedthru Interface.  Not knowing what else to try, I killed/rebooted/started the isi system:  everything came back including the zeroed channels. 

I've not seen this issue before.  Any ideas on what's wrong (I'm attaching a snapshot of the sensors as they were on DV).  Now I only looked at these sensors, and nothing else, so not sure if other channels have zeroes at their inputs.

Sidenote:  I tried killing scripts from the "isiham GDS CUST" medm window from the workstation in the Tech Lab, but it didn't work.  The medm screen didn't go WHITE, and my mouse eventually became froze within an medm screen (I wasn't able to do anything on this machine...so I had to power it off via the power button).
Images attached to this report
Displaying reports 87961-87980 of 88144.Go to page Start 4395 4396 4397 4398 4399 4400 4401 4402 4403 End