Wed Jan 08 10:07:22 2025 INFO: Fill completed in 7min 19secs
Gerardo confirmed a good fill curbside. TCtrip=-60C, TCmins = [-93C, -90C] OAT (2C, 36F)
Our range has been slowly falling, so I followed alog80461 to adjust the OPO temperature. We dropped Observing during this time (out from 16:33:14-16:35:14 UTC), and it looks to have helped out range a bit.
TITLE: 01/08 Day Shift: 1530-0030 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Observing at 158Mpc
OUTGOING OPERATOR: Tony
CURRENT ENVIRONMENT:
SEI_ENV state: USEISM
Wind: 8mph Gusts, 5mph 3min avg
Primary useism: 0.04 μm/s
Secondary useism: 0.51 μm/s
QUICK SUMMARY: Locked for almost 10 hours, just had an event candidate. We are just on the threshold for the seismic environment to be in Calm or Useism, so it has switched back and forth a few times over the night. No other alarms or other notables.
TITLE: 01/08 Eve Shift: 0030-0600 UTC (1630-2200 PST), all times posted in UTC
STATE of H1: Observing at 160Mpc
INCOMING OPERATOR: Tony
SHIFT SUMMARY: One lockloss this shift with an automated relock other than opting for an initial alignment once at DRMI. I also adjusted the OPO temp while relocking. H1 has been locked and observing for about 15 minutes.
Lockloss @ 04:09 UTC - online lockloss tool is down as of 16:07 PST (currently broken link: 1420344601)
No obvious cause. No real sign of an ETM glitch either.
H1 back to observing at 05:46 UTC.
FAMIS 31067
PMC Refl is back on the rise again after having been steady for about a week. The ISS diffracted power has been slowly dropping also; if it gets worse in the coming days I can bring it back up with a RefSignal adjustment.
No other major events of note.
Since I had some time, I quickly measured the OLTF of ALS PDH at X and Y using LSC EXTRA channels I connected some time ago (alog 80826). I enabled the IN2 and made sure that OUT2 is connected to IN1 (1st attachment). With this setting, H1:LSC-[XY]_EXTRA_AI_2/H1:ALS-[XY]_REFL_ERR_OUT_DQ is 40dB smaller than the OLTF, see the circuit diagram of the CM board (D040180 especially page 5) and an overview (D1002416/005).
It turns out that the PDH OLTF (2nd attachment, note that there's a factor of 100 in the denominator so you have to add 40dB) is about 10dB smaller in ALSY with the nominal setting (red) than ALSX (black dashed) despite that H1:ALS-Y_REFL_LOCK_LOCKEDGAIN (6dB) is 2dB larger than H1:ALS-X_REFL_LOCK_LOCKEDGAIN (4dB). So there's a total of 12dB gain difference somewhere upstream of the common mode board.
That shouldn't be such a big deal once it's locked, but it could be problematic for acquisition as H1:ALS-Y_REFL_LOCK_ACQUIREGAIN was -20dB while H1:ALS-X_REFL_LOCK_ACQUIREGAIN was and is -6dB. In other words, the electronics gain is 14dB smaller for Y than X and the sensing gain upstream of the common mode board is 12dB smaller for Y. It's 26dB difference in total.
I wanted to adjust the demod phase in Y but was distracted by something else, so I just increased the gain setting for Y: H1:ALS-Y_REFL_LOCK_ACQUIREGAIN is -12 (originally -20), H1:ALS-Y_REFL_LOCK_LOCKEDGAIN is 10 (was 6).
For LOCKEDGAIN, I tried 14dB and it started dropping lock for unknown reasons, 12dB was OK (brown trace) but I just didn't want to get close to 14dB.
I'm pretty sure ACQ gain could be increased further but -12dB is the gain I tested first and it locked quickly, and I didn't have time.
And this is where I was distracted.
I changed the CM board offset while PDH was locked and confirmed that it still has a measurable effect on the green transmission but it's not as drastic as before, this time it's only a few per cent effect. I saw no apparent mode hopping behavior either (i.e. the transmission didn't change shape from 00 to HOM), things were very stable. Not sure if the only difference was the alignment.
As per previous experiences, I went all the way up to -10V (which is attenuated by 0.28/100 in the CM board) but could not get past the true maxima of the transmission (i.e. "the other side of the slope"). Also the IN1 gain seemed to have an effect on the transmission when the offset was constant, i.e. the higher the gain the smaller the transmission.
We know that the error signal (in volts) is not drastically smaller at EY than EX.
After making sure that the demod phase is good, in another maintenance day we could e.g. slightly misalign the arm or TMS and observe the error signal when the arm is free swinging. If this is via HOM, that would make things different, probably for worse.
On Monday I used some templates that Sheila pointed me toward to get some data on HAM ISI coupling to DARM, to see if any of HAMs 2,3 and 6 are close to be a limiting noise anywhere. I did the injections using the templates Sheila gave me, I then used a script from Arnaud based on some of the pem scripts used to estimate couplings. For each table I got excitations in the vertical(Z), beamline (X or Y) and pitch (RY or RX) dofs. This was a first attempt, I think I will probably want to try doing some of this measurement again, but I'll wait to talk to Arnaud a bit about the data.
For each attached image, top subplot shows the quiet ISI dof in black, the injection is red. Bottom plot shows DARM and the estimated couplings for the dof.
None of these are really stand out to me, but maybe my injection could use some tuning.
Templates for each measurement are in /ligo/gitcommon/NoiseBudget/aligoNB/aligoNB/H1/couplings/ISI.
TITLE: 01/08 Day Shift: 1530-0030 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Observing at 156Mpc
INCOMING OPERATOR: Ryan S
SHIFT SUMMARY: Maintenance day today, with autoamted relocking aside from some testing of SRY locking and ALS during initial alignment. Keita worked on the ALS X&Y and some changes were made to ALSY that seemed to help relocking. We've been locked for 2.5 hours
LOG:
| Start Time | System | Name | Location | Lazer_Haz | Task | Time End |
|---|---|---|---|---|---|---|
| 22:08 | OPS | LVEA | LVEA | N | LASER SAFE | 15:07 |
| 15:43 | FAC | Eric | Mech room | n | Reheat wire fix | 16:06 |
| 15:56 | FAC | Chris | Xarm | n | Tumbleweed clearing | 20:10 |
| 15:57 | FAC | Kim, Nelly | FCES | n | Tech clean | 16:41 |
| 16:26 | TCS | Camilla | CR/LVEA | n | CO2 PWM tests | 17:19 |
| 16:34 | VAC | Travis | LVEA | n | Inspect HAM6 gauge | 16:37 |
| 16:34 | VAC | Jordan, Gerardo | FCES | n | Removing gauge for use at HAM6 | 18:52 |
| 17:04 | FAC | Tyler | LVEA, Mids | n | 3IFO checks | 17:49 |
| 17:24 | FAC | Richard, Ken | Mids | n | - | 18:11 |
| 17:39 | CC | RyanC | LVEA | n | Dust monitor testing | 18:19 |
| 17:55 | SQZ | Camilla, Jennie | LVEA | LOCAL | SQZ homodyne meas | 19:28 |
| 18:15 | FAC | Kim, Nelly | LVEA | n | Tech clean | 18:16 |
| 18:15 | FAC | Kim | EY | n | Tech clean | 19:37 |
| 18:18 | CC | RyanC | EY | n | Dust monitor testing | 18:49 |
| 18:19 | SEI | Jim, Mitchell | Ends | n | Wind fence, HEPI, dust pump checks | 18:52 |
| 18:21 | ISC | Keita | CR | n | TMS measurements | 20:13 |
| 18:50 | IAS | RyanC | LVEA | N | Setup FARO for next week | 19:08 |
| 18:54 | VAC | Jordan, Gerardo, Marc | EY | n | Fixing cables | 20:13 |
| 19:20 | VAC | Travis | EX | n | Prep for clean air replacement | 19:21 |
| 19:21 | VAC | Travis | LVEA | n | Grab parts | 19:29 |
| 19:23 | PCAL | Tony | PCAL lab | local | Check on lab | 19:34 |
| 20:05 | SQZ | Sheila, Camilla | LVEA | LOCAL | Homodyne meas rd2 | 20:40 |
| 21:50 | VAC | Gerardo, Travis | EX | n | Clean air prep | 22:40 |
| 23:33 | CAL | Tony | PCal Lab | LOCAL | Software updates | 00:33 |
| 23:33 | TCS | TJ | MER | n | Check TCS chillers | 23:43 |
I've updated the PEM_MAG_INJ and SUS_CHARGE Guardian nodes to not run their associated injections and drop H1 from observing if there is an active stand down alert from SNEWS, Fermi, Swift, or KamLAND (for supernova, GRB, and neutrino alerts). As a reminder, these normally start at 7:20am local time on Tuesdays if H1 is locked.
Due to a typo in the SUS_CHARGE Guardian (my fault), the in-lock charge measurements have not run since I implemented this change. I've fixed this and reloaded the node, so in-lock charge measurements should be back to running as usual at 7:45am Tuesday mornings if H1 is locked.
TITLE: 01/08 Eve Shift: 0030-0600 UTC (1630-2200 PST), all times posted in UTC
STATE of H1: Observing at 158Mpc
OUTGOING OPERATOR: TJ
CURRENT ENVIRONMENT:
SEI_ENV state: USEISM
Wind: 3mph Gusts, 2mph 3min avg
Primary useism: 0.05 μm/s
Secondary useism: 0.46 μm/s
QUICK SUMMARY: H1 has been locked and observing for over 2 hours.
In 81863 we looked a the RIN of the CO2 lasers on vs off. Today we repeated with PWM (from Synrad UC-2000), the noise level is considerably higher when PWM is on. Note that this isn't really the RIN as we're not dividing by the DC power.
Data saved to camilla.compton/Documents/tcs/templates/dtt/20250107_CO2_RIN.xml and 20250107_CO2Y_RIN.xml
The CO2Y plots also show the dark noise as there is no photo detector plugged into CO2Y_ISS_IN.
For some of the CO2X data, the CO2 guardian was relocking (sweeping PZT), noted above.
These channels are calibrated in Volts as the detector would output, before the gain of PD's amplifier D1201111 .
DC levels of power on the ISS PDs at the different powers are:
With PWM on, the noise level increases by around a factor of 10. Unsure why the AC channel sees this increase less than the DC channels.
Gabriele, Camilla
Erik showed me that we can look to higher frequencies using H1:IOP-OAF_L0_MADC{2,3}_TP_CH{10-13} channels at 65kHz. Can repeat 50% PWM next week.
Note that these are before the filtering (listed in 81868), we could filters back in with python... but it's mainly gains and some shaping of the AC channel below 20Hz and above 10kHz, a DC roll of is expected around 100kHz as in D1201111. DC values:
Matt Todd and I measured the powers before the CO2X ISS PDs today:
In 82182 using specs of PDs we think we are measuring 30-50mW. We didn't have time to check for clipping with an iris or alignment, both beams looked small but the PD's are also small ~1mmx1mm.
FAMIS 28387, last run in alog81957 (Dec 17th)
ETMY looks to have had the greatest changes since last measurement, other test masses look close to nominal.
We investigated the SHV cable connectivity between the Ion Pump Controller at EY and the Ion Pump at Y2-8 checking for faults. We did not detect any obvious faults, we did detect the prior splice which was installed back in 2016. We used the Fieldfox in TDR mode with a 1.2 meter launch cable in low pass mode. I have attached scans of these findings:
First photo is a shot from the Controller, there is a large impedance change at 19 meters from the connection point, this is the same location of the splice made in 2016, the repair looks like we would expect a splice to look.
https://alog.ligo-wa.caltech.edu/aLOG/index.php?callRep=28847
Second photo is a shot from the Ion Pump back to the end station. There is a very small bump at 20 meters from the ion pump that is real, but is very very tiny, could be a kinked cable, but not enough to cause issues.
Otherwise, the cable looks fine. Future testing is warranted.
M. Pirello, G. Moreno, J. Vanosky
After the cable was deemed good, we took a look at the controller, and found some "events" recorded on the log, see attached photo, one such events pertains to the glitch noticed here. All events recorded were kept on the controller. We are going to look further into this.
FAMIS 22015
pH of PSL chiller water was measured to be just above 10.0 according to the color of the test strip.
Because we moved the OPO crystal position yesterday, 8045, the crystal absorption will be changing for a few weeks, and we will need to adjust the temperature setting for the OPO until it settles, as Tony and I did last night. 80455. Here are two sets of instructions, one that can be used while in observing to adjust this, and one that can be done when we loose lock or are out of observing for some other reason.
For these first few days, please follow the out of observing instructions when relocking, if this hasn't been done in the last few hours, and please try to do it in the last few hours of the evening shift so that the temperature is close to well tuned at the start of the owl shift.
Out of observing instructions (to be done while recovering from a lockloss, can be done while ISC_LOCK is locking the IFO) (screenshot) :
In observing instructions:
Both the OPO temperature and the SQZ phase are ignored in SDF and can be adjusted while we are in observing, but it's important to log the times of any adjustments made.
Changes made to make this easier (Thanks Corey for beta testing the instructions):
Update to the In observing instructions:
Both the OPO temperature and the SQZ phase are ignored in SDF, but it's important go out of observing for the change and to log any adjustments made.