Displaying reports 10201-10220 of 89394.Go to page Start 507 508 509 510 511 512 513 514 515 End
Reports until 16:20, Saturday 30 November 2024
LHO General
corey.gray@LIGO.ORG - posted 16:20, Saturday 30 November 2024 (81552)
Sat DAY Ops Summary

TITLE: 11/30 Day Shift: 1530-0030 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Lock Acquisition
INCOMING OPERATOR: Ryan C
SHIFT SUMMARY:

H1 was locked entire shift except for a lockloss right before the shift.  Also squeezed in the Saturday Calibration (so just under 90min of downtime for the locking + calibration).
LOG:

H1 General
ryan.crouch@LIGO.ORG - posted 16:17, Saturday 30 November 2024 (81555)
OPS Saturday EVE shift start

TITLE: 11/30 Eve Shift: 0030-0600 UTC (1630-2200 PST), all times posted in UTC
STATE of H1: Observing at 158Mpc
OUTGOING OPERATOR: Corey
CURRENT ENVIRONMENT:
    SEI_ENV state: CALM
    Wind: 5mph Gusts, 2mph 3min avg
    Primary useism: 0.02 μm/s
    Secondary useism: 0.23 μm/s
QUICK SUMMARY:

Images attached to this report
H1 CAL
corey.gray@LIGO.ORG - posted 12:02, Saturday 30 November 2024 (81554)
H1 Calibration Measurement For Mon Commissioning (broadband headless + non-standard simulines)

H1 will be thermalized right around the Sat Calibration time of 1930utc (1130am PDT).  L1 has been down due to a frontend crash/chassis swap this morning, so will jump on this down time to get the calibration run for H1.  Louis Dartez wanted operators to continue running the new/non-standard simulines measurement (noted below).

Measurement NOTES:

Images attached to this report
LHO VE
david.barker@LIGO.ORG - posted 10:25, Saturday 30 November 2024 (81553)
Sat CP1 Fill

Sat Nov 30 10:10:58 2024 INFO: Fill completed in 10min 55secs

TC mins only just exceeded -75C, I have increased the trip to -70C for tomorrow's fill.

Images attached to this report
LHO General
corey.gray@LIGO.ORG - posted 07:49, Saturday 30 November 2024 (81551)
Sat DAY Ops Transition

TITLE: 11/30 Day Shift: 1530-0030 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Earthquake
OUTGOING OPERATOR: Ibrahim
CURRENT ENVIRONMENT:
    SEI_ENV state: EARTHQUAKE
    Wind: 6mph Gusts, 4mph 3min avg
    Primary useism: 0.10 μm/s
    Secondary useism: 0.25 μm/s
QUICK SUMMARY:

H1 lost lock recently most likely due to a M5.4 earthquake off the western coast of Mexico.

Overnight H1 had a lockloss at 1245 with no IMC/FSS oscillation tags.

It is Saturday, so a Calibration is scheduled late morning, but thermalization requirements may push this out to the afternoon since H1, L1 are currently both DOWN and V1 has been Observing 15min.

H1 General
ryan.crouch@LIGO.ORG - posted 22:00, Friday 29 November 2024 (81546)
OPS Friday EVE shift summary

TITLE: 11/30 Eve Shift: 0030-0600 UTC (1630-2200 PST), all times posted in UTC
STATE of H1: Observing at 160Mpc
INCOMING OPERATOR: Ibrahim
SHIFT SUMMARY: 2ndary microseism is increasing, 2 locklosses this shift. We've been locked and observing for 35 minutes.
LOG: No log

H1 General (Lockloss)
ryan.crouch@LIGO.ORG - posted 20:37, Friday 29 November 2024 - last comment - 21:28, Friday 29 November 2024(81549)
Lockloss at 04:36 UTC

Lockloss at 04:36 UTC

Comments related to this report
ryan.crouch@LIGO.ORG - 21:28, Friday 29 November 2024 (81550)

05:27 UTC Observing

LHO FMCS
ryan.crouch@LIGO.ORG - posted 19:39, Friday 29 November 2024 (81548)
Checking HVAC Fans - Weekly FAMIS 26344

Closes FAMIS 26344. Last checked in alog 81421.

For the CS MR_FAN3_170_1 looks to have gotten noisier 2 days ago.

For the OUT buildings EX_FAN1_570_2 got noticeably noisier two days ago and looks to be trending upwards.

Images attached to this report
LHO General
corey.gray@LIGO.ORG - posted 16:30, Friday 29 November 2024 (81538)
Fri Ops DAY Shift Summary

TITLE: 11/29 Day Shift: 1530-0030 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Observing at 160Mpc
INCOMING OPERATOR: Ryan C
SHIFT SUMMARY:

About 100min of downtime for the 9hr shift (with a lockloss early in the shift and one near the end of the shift).  For speed, I nudged H1 to CHECK MICH FRINGES to help with DRMI (the 2nd lockloss' ALS locking was all automatic).

Chilly Black Friday with temperatures barely going over 35°F.  µseism looks like it might have slightly inched above the 50th percentile over the last 24hrts.
LOG:

H1 General
ryan.crouch@LIGO.ORG - posted 16:24, Friday 29 November 2024 (81543)
OPS Friday EVE shift start

TITLE: 11/30 Eve Shift: 0030-0600 UTC (1630-2200 PST), all times posted in UTC
STATE of H1: Lock Acquisition
OUTGOING OPERATOR: Corey
CURRENT ENVIRONMENT:
    SEI_ENV state: CALM
    Wind: 3mph Gusts, 1mph 3min avg
    Primary useism: 0.02 μm/s
    Secondary useism: 0.22 μm/s
QUICK SUMMARY:

Images attached to this report
H1 General (Lockloss)
ryan.crouch@LIGO.ORG - posted 16:04, Friday 29 November 2024 - last comment - 17:28, Friday 29 November 2024(81544)
23:49 UTC lockloss (5:32 lock)

23:49 UTC lockloss IMC tag, ASC and IMC lost it within 5ms of eachother. It looks like the ISS might have lost it first then 30ms later the FSS and ASC lost it.

Images attached to this report
Comments related to this report
ryan.crouch@LIGO.ORG - 16:38, Friday 29 November 2024 (81545)

00:37 UTC lost it at TRANSITION_FROM_ETMX

ryan.crouch@LIGO.ORG - 17:28, Friday 29 November 2024 (81547)

01:25 UTC Observing

LHO VE
david.barker@LIGO.ORG - posted 10:15, Friday 29 November 2024 (81541)
Fri CP1 Fill

Fri Nov 29 10:05:18 2024 INFO: Fill completed in 5min 15secs

TC mins -79C,-78C. New trip -75C.

Images attached to this report
H1 General
corey.gray@LIGO.ORG - posted 09:34, Friday 29 November 2024 - last comment - 15:31, Friday 29 November 2024(81540)
LOCKLOSS @1713utc

H1 had a lockloss in fairly quiet conditions.  Lockloss had an "ETM_GLITCH" tag (ETMx, "zoom-in" attached); last time we had one of these was about 3-days ago.
IMC took a few min to acquire after lockloss.  ALSx locked, but was driven off by ASC to a pitch misalignment (tried touching up flashes via TMSx, but INCREASE FLASHES immediately took over).  DRMI looked ugly, so preemptively went to PRMI (which also looked bad) and then CHECK MICH FRINGES.

Images attached to this report
Comments related to this report
ryan.crouch@LIGO.ORG - 15:31, Friday 29 November 2024 (81542)Lockloss

DARM seems to move first, then within 1 ms ETMX L3 moves and DARM moves even more then ETMX L2 moves a lot more. ~150ms later the pattern happens again but the L2 response is larger and we lose lock ~100 ms later. I'm not sure this is actually a ETMX glitch.

Images attached to this comment
H1 PSL (PSL)
corey.gray@LIGO.ORG - posted 08:59, Friday 29 November 2024 (81539)
PSL Status Report (FAMIS #26325)

Laser Status:
    NPRO output power is 1.832W
    AMP1 output power is 70.03W
    AMP2 output power is 137.4W
    NPRO watchdog is GREEN
    AMP1 watchdog is GREEN
    AMP2 watchdog is GREEN
    PDWD watchdog is GREEN

PMC:
    It has been locked 2 days, 13 hr 47 minutes
    Reflected power = 24.38W
    Transmitted power = 104.7W
    PowerSum = 129.1W

FSS:
    It has been locked for 0 days 9 hr and 24 min
    TPD[V] = 0.835V

ISS:
    The diffracted power is around 3.2%
    Last saturation event was 0 days 9 hours and 31 minutes ago
Possible Issues:
    PMC reflected power is high

LHO General (CDS)
corey.gray@LIGO.ORG - posted 07:47, Friday 29 November 2024 (81537)
Fri Ops Day Transition

TITLE: 11/29 Day Shift: 1530-0030 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Observing at 157Mpc
OUTGOING OPERATOR: TJ
CURRENT ENVIRONMENT:
    SEI_ENV state: CALM
    Wind: 3mph Gusts, 1mph 3min avg
    Primary useism: 0.02 μm/s
    Secondary useism: 0.19 μm/s
QUICK SUMMARY:

On this Black Friday, H1's been locked almost 7.5hrs w/ a range just under 160Mpc.  Decently quiet environmentally with microseism hovering just over the 50th percentile the last 24+hrs; winds are low.

On CDS Overview, CDS SDF was a yellow box for an SDF Diff for H1:CDS-LLA_CONTACT_25_ENABLE in the NO state---THIS WAS ACCEPTED (see attached).

Images attached to this report
H1 General
ryan.crouch@LIGO.ORG - posted 22:06, Thursday 28 November 2024 (81532)
OPS Thursday Eve shift summary

TITLE: 11/29 Eve Shift: 0030-0600 UTC (1630-2200 PST), all times posted in UTC
STATE of H1: Observing at 152Mpc
INCOMING OPERATOR: TJ
SHIFT SUMMARY: We had two locklosses this shift, neither from the IMC. Both had automated relocks.
LOG: No log

Displaying reports 10201-10220 of 89394.Go to page Start 507 508 509 510 511 512 513 514 515 End