Reports until 16:04, Sunday 24 November 2024
LHO General
ibrahim.abouelfettouh@LIGO.ORG - posted 16:04, Sunday 24 November 2024 (81452)
OPS Eve Shift Start

TITLE: 11/25 Eve Shift: 0030-0600 UTC (1630-2200 PST), all times posted in UTC
STATE of H1: Observing at 157Mpc
OUTGOING OPERATOR: Corey
CURRENT ENVIRONMENT:
    SEI_ENV state: CALM
    Wind: 9mph Gusts, 6mph 3min avg
    Primary useism: 0.02 μm/s
    Secondary useism: 0.32 μm/s
QUICK SUMMARY:

IFO is in NLN and OBSERVING as of 17:10 UTC (~7 hr lock)

If L1 goes down, I was told I can drop out of OBSERVING and tune SQZ, which has been having some issues today.

H1 General (VE)
corey.gray@LIGO.ORG - posted 14:14, Sunday 24 November 2024 - last comment - 11:19, Thursday 12 December 2024(81451)
H1 Range Drop This Morning: CP1 Fill for 10min But Something Else For Hours After

This morning there was a range drop on H1 (163Mpc down to about 151Mpc, see attachment#1).  Was working on trying to figure out how to run the Range Check measurements, but while chatting with Vicky on Teamspeak, she reminded me about the daily CP1 Fill can affect range (see attachment #2 which is plot from Dave's alog)  ....and the effect certainly lines up! (Also see Oli's alog from Sept here.)  The time in question is 1802-1812utc (1002-1012amPT).  I will not share the Low-Range-Plots I took for 1810utc since CP1 Fill is most likely the culprit.

However, a note about the range is that it has not really returned to 163Mpc---it's hovered at 157Mpc post-CP1-Fill for the last 4+hrs.

So I ran another Low Range DTT for about an hour ago (2117utc/1317PT).

Images attached to this report
Comments related to this report
david.barker@LIGO.ORG - 08:58, Monday 25 November 2024 (81459)

Attached plots show the 30 minutes around the CP1 overfill for Sunday and Saturday. The H1 range shows a correlation with the CP1 discharge line pressure. An increase in line pressure indicates the presence of cold LN2 vapor, and later liquid, in the pipe. The Y manifold accelerometer signal shows correlated motion.

The accelerometer correlation can also be seen on the previous Sunday. This is not seen clearly during the week because the ACC was nore noisy, presumably due to LVEA activity around 10am each day.

Images attached to this comment
david.barker@LIGO.ORG - 09:13, Monday 25 November 2024 (81460)

Attached shows ACC signal Sun 8th Sep 2024 correlated to the discharge pressure. Back then we were filling at 8am. It doesn't appear that the beam manifold motion has gotten any worse over the past two months during cp1 fills.

Images attached to this comment
shivaraj.kandhasamy@LIGO.ORG - 09:32, Tuesday 26 November 2024 (81488)

The attached plots shows the BNS range around CP1 fill times for the last six CP1 fills (10 AM PDT) when the IFO was also in the locked state. In four cases among these six, we can see BNS range drop during the CP1 fill. In the remaining two it is not clear whether CP1 fill happened or not. We see a spike in H0:VAC-LY_TERM_M17_CHAN2_IN_MA.mean, but we don't see an extened increase in that channel as we see in the other four cases.  

Images attached to this comment
shivaraj.kandhasamy@LIGO.ORG - 11:19, Thursday 12 December 2024 (81795)DetChar

The attached plot show the BNS range variations during the CP1 fill times during the first ~10 days of December. We are plotting only those days when the IFO was in observing (H1:GRD-IFO_OK == 1). For these days, the drop in the BNS range during the fill times seem lower than what we saw during November (plot in the above comment). We also see that the fill times are in general less in these ten days compared to what were in November. Maybe longer the fill time, more the drop in the BNS range!?  Also looking at these plots and plots from November, it seem the range might be coming back to a lower value after the fill than it's value before the fill.  

Images attached to this comment
LHO VE
david.barker@LIGO.ORG - posted 10:18, Sunday 24 November 2024 (81450)
Sun CP1 Fill

Sun Nov 24 10:10:08 2024 INFO: Fill completed in 10min 4secs

TCs only just went below -90C trip, so I have increased the trip to -80C for tomorrow's fill.

TCB started at 0C, hence the additional decades in the log plot.

Images attached to this report
H1 General
corey.gray@LIGO.ORG - posted 09:20, Sunday 24 November 2024 (81449)
Back To OBSERVING

H1 is now back to OBSERVING and it was painless--for the most part.

LHO VE (CDS, VE)
corey.gray@LIGO.ORG - posted 08:28, Sunday 24 November 2024 - last comment - 09:05, Sunday 24 November 2024(81447)
VACSTAT Glitches At 2 Separate Times Overnight

Had two separate VACSTAT glitches overnight (plots attached)

  1. BSC3:  1209utc (409amPT) for about 2-seconds.
  2. EX:  1347utc (547amPT) for just over 1-second.

I'm not sure on how to run a reset (toggling the DISABLED/ENABLED removed red status for BSC3, but it changed to a purple color, so I'm guessing a restart for vacstat_ioc.service will be needed per alog); I sent a text to Dave.

Images attached to this report
Comments related to this report
david.barker@LIGO.ORG - 09:05, Sunday 24 November 2024 (81448)

This morning's VACSTAT false alarm was caused by two sensors randomly glitching within 2 hours of each other (Corner station BSC3 and EX BSC9).

Timeline (all times PST):

    04:08 BSC3 PT133_MOD2 has one of its regular glitches, which puts VACSTAT into sensitive mode waiting for a coincident chamber trip.

    05:47 BSC9 PT510B has a random glitch which exceeds the lowered delta-P trip level. Alarms are sent to the vacuum team.

    08:48 VACSTAT restarted to reset

Attached 5 hour trend shows the BSC3 glitch (top row) and the BSC9 glitch (bottom row) 1hr 38min later.

Attached BSC9 7-day trend show it does occassionally have small glitches, but this morning's was larger and just enough to exceed the lowered delta-P trip level.

Images attached to this comment
LHO General (CDS)
corey.gray@LIGO.ORG - posted 07:54, Sunday 24 November 2024 (81444)
Sun DAY Ops Transition

TITLE: 11/24 Day Shift: 1530-0030 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Lock Acquisition
OUTGOING OPERATOR: TJ
CURRENT ENVIRONMENT:
    SEI_ENV state: CALM
    Wind: 4mph Gusts, 2mph 3min avg
    Primary useism: 0.02 μm/s
    Secondary useism: 0.30 μm/s
QUICK SUMMARY:

H1 had an almost 16hr lock with the recent lockloss (having some SQZ issues due to the ISS), but NO IMC or FSS tags (link).  H1 has been having troubles with green arms (with repeated INCREASE FLASHES seen yesterday), so starting an initial alignment.

There is a RED VACstat box on the CDS Overview.  It corresponds to:  1 glitch detected and "multiple" state--which I'm assuming is because it sees a glitch at LVEA's BSC3 and EX (see attached).

Environmentally, microseism is between the 50th -95th percentile and winds are low.

Images attached to this report
H1 General (SQZ)
thomas.shaffer@LIGO.ORG - posted 05:23, Sunday 24 November 2024 - last comment - 08:12, Sunday 24 November 2024(81442)
Ops Owl Update

The SQZ OPO is struggling to stay locked. We've dropped Observing 7x so far in the last hour. So far it has been able to recover itself, but now it seems to be struggling. If it can't recover itself soon, I'll be calling for help.

On the bright side, H1 has been locked for over 13 hours.

Comments related to this report
thomas.shaffer@LIGO.ORG - 06:36, Sunday 24 November 2024 (81443)

Looks like the SQZ sorted itself out out at 1422 and has stayed locked for 15 min so far.

victoriaa.xu@LIGO.ORG - 08:12, Sunday 24 November 2024 (81446)SQZ

Since IFO was down, I tried to fix this. SHG output power dropped >30% overnight, and ISS ran out of range trying to follow (so not necessarily a pump iss alignment problem). See trends in first attachment.

1) I turned the pico-waveplate before the ISS AOM to sent more power to the fiber (aka reject less green power). This pico worked.

2) Adjusted SHG temperature from 35.95 C --> 35.3 C to optimize output green power, which is a surprisingly big move. See second attachment of trends to optimize temperature. Not sure why the setpoint temperature changed so much, and I wonder if it will change back to "normal" later.

Conservatively, even though 35.3 C was best for SHG green power, I set the SHG TEC setpoint inbetween at 35.5 C, and accepted this in SDF.

Images attached to this comment
LHO General
ibrahim.abouelfettouh@LIGO.ORG - posted 22:00, Saturday 23 November 2024 (81441)
OPS Eve Shift Summary

TITLE: 11/24 Eve Shift: 0030-0600 UTC (1630-2200 PST), all times posted in UTC
STATE of H1: Observing at 158Mpc
INCOMING OPERATOR: TJ

SHIFT SUMMARY:

IFO is in NLN and OBSERVING as of 23:29 UTC

It has been a very quiet shift with no operator intervension whatsoever. We've been locked and OBSERVING for about 6hrs and a half.

We did drop out of OBSERVING from 05:26 UTC to 05:31 UTC due to the SQZ FC unlocking. However, guardian managed to automatically relock SQZ and get back into OBSERVING.

LOG:

None

LHO General
corey.gray@LIGO.ORG - posted 16:29, Saturday 23 November 2024 (81434)
Sat DAY Ops Summary

TITLE: 11/23 Day Shift: 1530-0030 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Observing at 161Mpc
INCOMING OPERATOR: None
SHIFT SUMMARY:

It has been a shift with a return to decent locking with H1 unlocked ~2.5hrs for the shift.  Saturday Calibration was run (coordinated with LLO).  Overall locking was fairly easy although the ALS took a bit of time (not bad), and DRMI locking was a little tough and needed PRMI/CHECK_MICH_FRINGES.  But after that locking has been automated.
LOG:

LHO General
ibrahim.abouelfettouh@LIGO.ORG - posted 16:09, Saturday 23 November 2024 (81440)
OPS Eve Shift Start

TITLE: 11/24 Eve Shift: 0030-0600 UTC (1630-2200 PST), all times posted in UTC
STATE of H1: Observing at 159Mpc
OUTGOING OPERATOR: Corey
CURRENT ENVIRONMENT:
    SEI_ENV state: CALM
    Wind: 8mph Gusts, 3mph 3min avg
    Primary useism: 0.01 μm/s
    Secondary useism: 0.25 μm/s
QUICK SUMMARY:

IFO is in NLN and OBSERVING as of 23:29 UTC

IFO has been behaving following the NPRO swap swap that took place Thurs and Fri.

H1 CAL (CAL)
corey.gray@LIGO.ORG - posted 13:39, Saturday 23 November 2024 (81438)
Saturday H1 Calibration Measurement (broadband headless + simulines)

Had to delay this measurement until 1pm locally due to a lockloss in the morning (coordinated with LLO [JoeH] to drop both H1 & L1 at the same time).

For this calibration, ran a non-standard measurement in that the simulines measurement was one Louis Dartez specifically requested be run for H1 (see below).

Measurement NOTES:

Images attached to this report
H1 OpsInfo (OpsInfo)
corey.gray@LIGO.ORG - posted 12:45, Saturday 23 November 2024 (81439)
ACCIDENTAL Drop From OBSERVING: Operator ERROR

20:36:51- 20:37:40 Drop from OBSERVING

This was purely accidental.  I had too many windows open on my Desktop, and was positioning a browser with GWIstat on it (so I could watch it during the next drop from Observing in a few minutes for the CALIBRATION measurement), BUT my fat fingers or bad eyes had my mouse accidentally click the ALS_XARM All-Guardian window's OFFLOAD_ETM_TMS_WFS state!

Since the arm is SHUTTERED, I don't think it did anything to ALSx (see attached LOG screenshot). 

Immediately re-selected SHUTTERED, and returned the NODE to MANAGED & then H1 went back to OBSERVING.

Images attached to this report
LHO VE
david.barker@LIGO.ORG - posted 10:21, Saturday 23 November 2024 (81437)
Sat CP1 Fill

Sat Nov 23 10:09:56 2024 INFO: Fill completed in 9min 53secs

Running with new trip temps of -90C, TCmins today -108C,-106C.

Images attached to this report
H1 General
corey.gray@LIGO.ORG - posted 08:53, Saturday 23 November 2024 (81436)
1633utc (833amPT) Lockloss

For this 2nd lock post-recent-NPRO-swap, H1's lockloss did NOT have an IMC or FSS tag:  link

That's 2 for 2 so far!

LHO General (CAL)
corey.gray@LIGO.ORG - posted 07:43, Saturday 23 November 2024 - last comment - 08:01, Saturday 23 November 2024(81433)
Sat DAY Ops Transition

TITLE: 11/23 Day Shift: 1530-0030 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Observing at 161Mpc
OUTGOING OPERATOR: None
CURRENT ENVIRONMENT:
    SEI_ENV state: CALM
    Wind: 4mph Gusts, 2mph 3min avg
    Primary useism: 0.02 μm/s
    Secondary useism: 0.31 μm/s
QUICK SUMMARY:

H1's been locked 5hrs.  After RyanS's 1st Observing lock (which was about 1hr), the next (& current) lock was fully automated (w/ CHECK MICH FRINGES + PRMI).

Environmentally, microseism had a bump up about 12hrs ago, but has been trending down slowly since.  Winds are almost nonexistant.  There was a light rain on the drive in.

It is Saturday, so I am assuming a calibration is planned this morning for 1930utc (1130amPT).

Comments related to this report
corey.gray@LIGO.ORG - 08:01, Saturday 23 November 2024 (81435)

926utc Lockloss was NOT an IMC lockloss btw.  Woo Hoo.

H1 General (ISC, SEI)
ryan.short@LIGO.ORG - posted 00:59, Saturday 23 November 2024 (81432)
H1 Back to Observing Post-NPRO Swap

H1 is back to observing at 161Mpc as of 08:34 UTC following a two-day NPRO swap.

Reached low noise at 08:21 UTC but couldn't start observing due to several outstanding SDF diffs. I made my best guess for some of these, so I encourage the appropriate people check on these changes and make updates as necessary. The models in question are:

Images attached to this report