Reports until 22:00, Saturday 07 September 2024
LHO General
ibrahim.abouelfettouh@LIGO.ORG - posted 22:00, Saturday 07 September 2024 (79971)
OPS Eve Shift Summary

TITLE: 09/08 Eve Shift: 2330-0500 UTC (1630-2200 PST), all times posted in UTC
STATE of H1: Observing at 152Mpc
INCOMING OPERATOR: Ryan S
SHIFT SUMMARY:

IFO is in NLN and OBSERVING as of 21:52 UTC (7hr 20 min lock) with some minor squeeze exceptions. Otherwise, very smooth day with 0 locklosses during my shift.

The squeezer has been acting up today:

23:04 UTC COMISSIONING: Squeezer was far from optimal and while still observing, we were only getting 120ish MPc range. As such, Oli and I went into temp comissioning to run the temperature optimization script before trying to relock it. While this was happening, Naoki called and said he thought it was a Pump ISS issue and then took hold of IFO to fix it. He was successful and we were back to obsering at our recent 155ish MPc. OBSERVING again as of 23:27 UTC

01:53 UTC COMISSONING: Squeezer unlocked, sending us into comissiong but within a few minutes it relocked again automatically. I was watching it do so. We were OBSERVING again as of 01:58 UTC.

Other:

We successfuly rode through a 6.0 mag EQ from Tonga. EQ mode triggered successfully.

Dust is high in the Optics Lab - I was told by Oli yesterday that there's a strange acummulation of sand by a dust monitor and that some measures were taken to remove the sand though perhaps more has built up. The 300NM PCF monitor is at RED alert and the 500NM PCF monitor is at YELLOW.

LOG:

None

H1 General
oli.patane@LIGO.ORG - posted 16:30, Saturday 07 September 2024 (79970)
Ops Day Shift End

TITLE: 09/07 Day Shift: 1430-2330 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Commissioning
INCOMING OPERATOR: Ibrahim
SHIFT SUMMARY: We have been Locked for close to 2 hours. Not currently Observing because Naoki is trying to adjust some squeeze stuff since our range is really bad right now. Quiet day with one lockloss and easy relocking
LOG:

14:30UTC Observing and Locked for 7:47hrs
15:28 Plane passes overhead
15:38 Superevent S240907cg
18:30 Left Observing to run calibration sweep
19:04 Calibration measurements finished, back into Observing
19:36 Lockloss

20:20 We started going through CHECK_MICH_FRINGES for the second time so I took us to DOWN and started an initial alignment
20:41 Initial alignment done, relocking
21:41 NOMINAL_LOW_NOISE
    - OPO couldn't catch, I lowered opo_grTrans_setpoint_uW to 69 in sqzparams, reloaded OPO, locked the ISS, and then adjusted the OPO temperature a bit until SQZ-CLF_REFL_RF6_ABS was maximized. Accepted new temperature setpoint and went into Observing
21:52 Observing
23:04 Left Observing to run sqz alignment

LHO General
ibrahim.abouelfettouh@LIGO.ORG - posted 16:03, Saturday 07 September 2024 (79968)
OPS Eve Shift Start

TITLE: 09/07 Eve Shift: 2330-0500 UTC (1630-2200 PST), all times posted in UTC
STATE of H1: Observing at 136Mpc
OUTGOING OPERATOR: Oli
CURRENT ENVIRONMENT:
    SEI_ENV state: SEISMON_ALERT
    Wind: 13mph Gusts, 6mph 3min avg
    Primary useism: 0.04 μm/s
    Secondary useism: 0.09 μm/s
QUICK SUMMARY:

IFO is in NLN and OBSERVING as of 21:52 UTC

X1 SUS
oli.patane@LIGO.ORG - posted 13:58, Saturday 07 September 2024 (79966)
08/30 BBSS M1 Transfer function measurements

We have another installment of transfer functions for the BBSS. These were taken on August 30th and results can be found in $(sussvn)/BBSS/X1/BS/SAGM1/Results/2024-08-30_2300_tfs/ and I've attached the pdf. We've been dealing with the mystery of the F1 OSEM on M1 drifting downwards sometimes (see 79941 - very important info), and through we believe that the drift does not affect the transfer functions, we still want to make it clear that this measurement was taken shortly after adjusting for the drift, and over the next few days we confirmed that it was still drifting down. We also did a comparison by plotted this measurement set next to the set from July 12(79181), which was close to when the new (shorter by 9mm) wire loop was installed, and which was a time where we did have F1 drift, although in that case the measurements were taken over a week after F1 started the drift, so it had already travelled most of the way down that it was going to travel (drifts down in an exponential decay-like fashion). I also added the measurements from back in January when we completed the first iteration75787. It's interesting to see how the July and August Pitch TFs line up with each other around 1Hz as compared to the January measurement and the model. The location of this peak depends heavily on the distance between the M1 blades and the center of mass of M1, so this shift makes sense since the M1 blade heights have been changed since the initial build in January, and the current model doesn't yet reflect this change (comparison of how d1 changes the model with this measurement also plotted).

Non-image files attached to this report
H1 General (Lockloss)
oli.patane@LIGO.ORG - posted 12:37, Saturday 07 September 2024 - last comment - 14:57, Saturday 07 September 2024(79965)
Lockloss

Lockloss @ 09/07 19:36UTC after nearly 13 hours Locked

Comments related to this report
oli.patane@LIGO.ORG - 14:57, Saturday 07 September 2024 (79967)

21:52 UTC Observing

H1 General
oli.patane@LIGO.ORG - posted 12:25, Saturday 07 September 2024 (79964)
Ops DAY Midshift Status

Currently Observing right around 160Mpc and have been Locked for 12.5 hours. We dropped Observing a little while ago to run a calibration sweep, but we've been back Observing for over half an hour now.

H1 CAL
oli.patane@LIGO.ORG - posted 12:04, Saturday 07 September 2024 (79963)
Calibration Measurements September 07 2024

Calibration measurements run. Before starting measurements we had been Locked for 11:45mins. calibration monitor ss

Measurements completed, but we got this error in simulines - not sure if this exact error is already known about but I thought it wouldn't hurt to attach it just in case.

 

Broadband (18:30 - 18:35UTC)

Output file:

/ligo/groups/cal/H1/measurements/PCALY2DARM_BB/PCALY2DARM_BB_20240907T183023Z.xml

 

Simulines (18:38 - 19:01UTC)

Output files:

/ligo/groups/cal/H1/measurements/DARMOLG_SS/DARMOLG_SS_20240907T183846Z.hdf5

/ligo/groups/cal/H1/measurements/PCALY2DARM_SS/PCALY2DARM_SS_20240907T183846Z.hdf5

/ligo/groups/cal/H1/measurements/SUSETMX_L1_SS/SUSETMX_L1_SS_20240907T183846Z.hdf5

/ligo/groups/cal/H1/measurements/SUSETMX_L2_SS/SUSETMX_L2_SS_20240907T183846Z.hdf5

/ligo/groups/cal/H1/measurements/SUSETMX_L3_SS/SUSETMX_L3_SS_20240907T183846Z.hdf5

Images attached to this report
LHO VE
david.barker@LIGO.ORG - posted 08:15, Saturday 07 September 2024 (79962)
Sat CP1 Fill

Sat Sep 07 08:08:26 2024 INFO: Fill completed in 8min 23secs

Images attached to this report
H1 General
oli.patane@LIGO.ORG - posted 07:33, Saturday 07 September 2024 (79961)
Ops Day Shift Start

TITLE: 09/07 Day Shift: 1430-2330 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Observing at 157Mpc
OUTGOING OPERATOR: Ryan S
CURRENT ENVIRONMENT:
    SEI_ENV state: CALM
    Wind: 5mph Gusts, 3mph 3min avg
    Primary useism: 0.01 μm/s
    Secondary useism: 0.09 μm/s
QUICK SUMMARY:

Currently Observing and have been Locked for almost 8 hours. Nice change compared to the past 24+ hours of short locks.

LHO General
ibrahim.abouelfettouh@LIGO.ORG - posted 22:00, Friday 06 September 2024 (79960)
OPS Eve Shift Summary

TITLE: 09/07 Eve Shift: 2330-0500 UTC (1630-2200 PST), all times posted in UTC
STATE of H1: Lock Acquisition
INCOMING OPERATOR: Ryan S
SHIFT SUMMARY:

IFO is ALIGNING (Initial Alignment)

We have been experiencing weirdly short locks <2hrs for the last 5 locks. While locking itself is easy and automatic, it seems that as we approach the 1.5 hr mark, the HAM6 ISI gets saturated (at least in my 3 locks in last day or so). Additionally, PI 24 has been ringing up but damping slower than in the last few shifts. Moreso, we're getting ALS locklosses with no immediately apparent reason (No EQs and no Microseism). I've had to do an intiial alignment for both my lock acquistions. The last one happened 30 minutes before shift-end but I plan to investigate it in tomorrow's shift.

LOG:

None

H1 General
oli.patane@LIGO.ORG - posted 16:43, Friday 06 September 2024 (79958)
Ops Day Shift End

TITLE: 09/06 Day Shift: 1430-2330 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Lock Acquisition
INCOMING OPERATOR: Ibrahim
SHIFT SUMMARY: Lots of locklosses but pretty easy relocks
LOG:

14:30 Observing and Locked for 30 mins
15:53 Lockloss after almost 2 hours locked https://alog.ligo-wa.caltech.edu/aLOG/index.php?callRep=79946
16:06 Lockloss from TRANSITION_DRMI_TO_3F, starting initial alignment
16:29 Initial alignment done, relocking
17:20 NOMINAL_LOW_NOISE    
17:23 Observing

18:51 Lockloss after 1.5 hours https://alog.ligo-wa.caltech.edu/aLOG/index.php?callRep=79949
    - Had to restore ETMY and TMSY to values from previous lock's LOCKING_ARMS_GREEN, and then had to still touch them up to get ALSY to lock
20:14 Observing

22:27 Lockloss after 2.25 hours https://alog.ligo-wa.caltech.edu/aLOG/index.php?callRep=79954
22:28 Started an initial alignment
    - Couldn't get to SRC_ALIGN, so I went to ACQUIRE_SRY and then moved SRM to minimize the error signals in SRC1. Then SRC locked and offloaded fine
22:56 Initial alignment done, relocking

23:42 NOMINAL_LOW_NOISE                                                                                                                                                                                                                                                                                                                                                                                                                                                                                             

Start Time System Name Location Lazer_Haz Task Time End
23:58 SAF H1 LHO YES LVEA is laser HAZARD 18:24
14:49 FAC Kim OpticsLab n Tech clean 15:05
15:38 FAC Mitchell EX, EY n Dust monitor checks 16:31
16:11 FAC Kim OpticsLab n Tech clean - vacuuming up sand 16:56
16:19 PCAL Francisco PCAL Lab y(local) Checking for sand 16:31
16:20 OPT Sheila OptLab n Checking for sand 16:31
18:37 FAC Kim OptLab n Checking for more sand 18:47
21:46 FIT Vicky YARM n Running fast 22:18
H1 TCS
oli.patane@LIGO.ORG - posted 16:31, Friday 06 September 2024 (79957)
TCS Chiller Water Level Top-Off FAMIS

Closes FAMIS#27797, last checked 79723

Filled both to close to max. No leak in water cup

TCSX:

Before: 29.2

After: 30.5

Added 440mL of water

TCSY:

Before: 9.8

After: 10.6

Added 275mL of water

LHO General
ibrahim.abouelfettouh@LIGO.ORG - posted 16:06, Friday 06 September 2024 (79956)
OPS Eve Shift Start

TITLE: 09/06 Eve Shift: 2330-0500 UTC (1630-2200 PST), all times posted in UTC
STATE of H1: Lock Acquisition
OUTGOING OPERATOR: Oli
CURRENT ENVIRONMENT:
    SEI_ENV state: CALM
    Wind: 11mph Gusts, 6mph 3min avg
    Primary useism: 0.02 μm/s
    Secondary useism: 0.14 μm/s
QUICK SUMMARY:

IFO is LOCKING and in PRMI_ASC

H1 SEI
oli.patane@LIGO.ORG - posted 15:31, Friday 06 September 2024 (79955)
Seismometer Mass Check Monthly FAMIS

Closes FAMIS#26493, last checked 79438

T240 (channels averaged between 2024-09-06 22:13:59 - 22:14:09UTC)

There are 14 T240 proof masses out of range ( > 0.3 [V] )!
ETMX T240 2 DOF X/U = -0.705 [V]
ETMX T240 2 DOF Y/V = -0.571 [V]
ETMX T240 2 DOF Z/W = -0.543 [V]
ITMX T240 1 DOF X/U = -1.471 [V]
ITMX T240 1 DOF Y/V = 0.317 [V]
ITMX T240 1 DOF Z/W = 0.42 [V]
ITMX T240 3 DOF X/U = -1.535 [V]
ITMY T240 3 DOF X/U = -0.753 [V]
ITMY T240 3 DOF Z/W = -1.878 [V]
BS T240 1 DOF Y/V = -0.404 [V]
BS T240 3 DOF Y/V = -0.321 [V]
BS T240 3 DOF Z/W = -0.504 [V]
HAM8 1 DOF Y/V = -0.512 [V]
HAM8 1 DOF Z/W = -0.824 [V]

All other proof masses are within range ( < 0.3 [V] ):
ETMX T240 1 DOF X/U = -0.108 [V]
ETMX T240 1 DOF Y/V = -0.111 [V]
ETMX T240 1 DOF Z/W = -0.191 [V]
ETMX T240 3 DOF X/U = -0.133 [V]
ETMX T240 3 DOF Y/V = -0.201 [V]
ETMX T240 3 DOF Z/W = -0.104 [V]
ETMY T240 1 DOF X/U = 0.013 [V]
ETMY T240 1 DOF Y/V = 0.097 [V]
ETMY T240 1 DOF Z/W = 0.162 [V]
ETMY T240 2 DOF X/U = -0.094 [V]
ETMY T240 2 DOF Y/V = 0.167 [V]
ETMY T240 2 DOF Z/W = 0.039 [V]
ETMY T240 3 DOF X/U = 0.175 [V]
ETMY T240 3 DOF Y/V = 0.036 [V]
ETMY T240 3 DOF Z/W = 0.096 [V]
ITMX T240 2 DOF X/U = 0.121 [V]
ITMX T240 2 DOF Y/V = 0.24 [V]
ITMX T240 2 DOF Z/W = 0.204 [V]
ITMX T240 3 DOF Y/V = 0.106 [V]
ITMX T240 3 DOF Z/W = 0.108 [V]
ITMY T240 1 DOF X/U = 0.05 [V]
ITMY T240 1 DOF Y/V = 0.057 [V]
ITMY T240 1 DOF Z/W = -0.059 [V]
ITMY T240 2 DOF X/U = 0.044 [V]
ITMY T240 2 DOF Y/V = 0.193 [V]
ITMY T240 2 DOF Z/W = 0.055 [V]
ITMY T240 3 DOF Y/V = 0.037 [V]
BS T240 1 DOF X/U = -0.179 [V]
BS T240 1 DOF Z/W = 0.082 [V]
BS T240 2 DOF X/U = -0.104 [V]
BS T240 2 DOF Y/V = 0.004 [V]
BS T240 2 DOF Z/W = -0.133 [V]
BS T240 3 DOF X/U = -0.211 [V]
HAM8 1 DOF X/U = -0.279 [V]
 

STS (channels averaged between 2024-09-06 22:21:52 - 22:22:02UTC)

There are 1 STS proof masses out of range ( > 2.0 [V] )!
STS EY DOF X/U = -2.402 [V]

All other proof masses are within range ( < 2.0 [V] ):
STS A DOF X/U = -0.521 [V]
STS A DOF Y/V = -0.829 [V]
STS A DOF Z/W = -0.536 [V]
STS B DOF X/U = 0.335 [V]
STS B DOF Y/V = 0.945 [V]
STS B DOF Z/W = -0.448 [V]
STS C DOF X/U = -0.764 [V]
STS C DOF Y/V = 0.766 [V]
STS C DOF Z/W = 0.563 [V]
STS EX DOF X/U = -0.17 [V]
STS EX DOF Y/V = -0.038 [V]
STS EX DOF Z/W = 0.075 [V]
STS EY DOF Y/V = 0.005 [V]
STS EY DOF Z/W = 1.225 [V]
STS FC DOF X/U = 0.24 [V]
STS FC DOF Y/V = -1.056 [V]
STS FC DOF Z/W = 0.622 [V]

H1 General (Lockloss)
oli.patane@LIGO.ORG - posted 15:30, Friday 06 September 2024 - last comment - 16:45, Friday 06 September 2024(79954)
Lockloss

Lockloss @ 09/06 22:27UTC after 2:13 hours locked. Not sure why these locks have been so short.

Comments related to this report
oli.patane@LIGO.ORG - 16:45, Friday 06 September 2024 (79959)

23:44 Observing

X1 SUS (SUS)
ibrahim.abouelfettouh@LIGO.ORG - posted 18:57, Thursday 05 September 2024 - last comment - 16:19, Saturday 07 September 2024(79941)
BBSS M1 Pitch Instability F1 BOSEM Drift: The Saga Continues

Ibrahim, Oli, Jeff, Betsy, Joe, Others

Summary:

Relevant Alogs:

alog 79079: Recent Post-TF Diagnostic Check-up - one of the early discoveries of the drift and pitch instability.

alog 79181: Recent M1 TF Comparisons. More recent TFs have been taken (found at: /ligo/svncommon/SusSVN/sus/trunk/BBSS/X1/BS/SAGM1/Data on the X1 network). We are waiting on updated confirmation of model parameters in order to know what we should correctly be comparing our measurements to. We just confirmed d4 a few days ago following the bottom wire loop change and now seek to confirm d1 and what that means with respect to our referential calibration block.

alog 79042: First investigation into the BOSEM drift - still operating erroneously under the tmperature assumption.

alog 79032: First discovery of drift issue, originally erroneously thought to be part of the diurnal temperature driven suspension sag (where I though that blades sagging more than others contributed to the drift in pitch).

Hypothesis:

We think that this issue is related to the height of the blades for these reasons:

  1. The issue was fixed when we lowered all blades from the calibration block's "nominal" or zero by -1.5mm with all 4 blades roughly close to this number (avg -1.5mm)
  2. The issue came back when we attempted to fix the S-shaped M1 blade tip by correcting the extra swivel it needed to have in order to stay at the same height. (Joe recommendation to Betsy)
  3. Oli and Jeff have a d1 investigation in alog 76071 overlays different P to P model TFs when the blade heights are above/below their physical D (called FD in the attached plots).
    1. Interestingly, there is a new mode at roughly 1.9Hz when d is above the model's physical D by +-4mm. This mode is confirmed to not be cross coupling. Our recent TFs don't have them but TFs with the drift earlier do - I think this is a red herring.
    2. More clearly, the attached file shows overlays from different d1 sizes (Pitch).
  4. While the F1 blades are at an avg height of -1.5mm below nominal calibration block height, the spread between the individual blades is higher than before, with the problematic "soft/S" blade measuring at only -1mm. There's another blade at -1.8mm. This is the only difference between our current drifty -1.5mm avg and the non-drifty -1.5mm avg is the spread of each indiv. blade height. At this point, I'm interested in seeing how the spread of individual blades affects the drift effect in addition to just an everage d1 drop - could it be a combo of these effects? We can investigate the latter by playing with the model and the former by emperically measuring the drift itself.

Our Units:

Sensor Calibration Block Nominal: 0mm = 25.5mm using shims, drifty - what below measurements are based on
Config 1: -1.5mm avg = 24mm using shims, no drift
Config 2: -1.5mm avg = 24mm using shims, drifty. Only difference is that the spread of the individual blade tip heights is greater. Indiv blade heights: -1.6mm, -1.5mm, -1.0mm, -1.8mm.

We need to know how the calibration block converts to model parameters in d1 and whether that's effective or physical d1 in the model. Then we can stop using referential units.

To further investigate, we have questions:

  1. What is the "sensor calibration block" calibrated to? Physical D (Center of Mass to blade tip) or Effective D?  What are these values? We just want to find a model way to test parameters rather than the cal block or the shim methods to our model since right now we're going off potentially old information.
  2. Could differences between the 4 individual blades be causing a drift this stark? (i.e. it's not a net d1 height issue but a blade to blade height issue or a combo). I'm thinking this may be the case since we have two equal net heights (-1.5mm avg) with the only difference being the spread of the indiv. heights.

Some Early Observations (attempting to constrain our model to our measurements):

  1. TFs before and after the F1 drift manifested (now vs 7 days ago) barely change the actual peak locations, but that's expected due to nature of TFs (I think).
  2. The difference between -1mm and -3mm drastically changes the 1.05Hz peak's position. In general, small mm changes have noticeable decimal freq. changes.
  3. The shape of the model curve is different for -3mm and -5mm, having positive inflection. Anything higher has our straight/negative inflection shape.

Attachments:

F1Drift09052024: BOSEM Drift over the last 7 days. Notice that the F1 OSEM is the only one showing a drift. LF and RT show a diurnal temperature based change due to suspension sagging but this is unrelated.
F1DriftEuler09052024: BOSEM Euler Basis Drift over the last 7 days. Notice that only Pitch is showing the drift
F1DriftM2CountsEuler09052024: BOSEM Counts Drift in the M2 (PUM) Stage for both euler and direct. Notice that there is no percieveable drifting or pitching here. Disclaimer: The M2 Sat-amp box is old and has a transimpedance issue. I just got a spare and will switch it out when not on-shift.
triplemodelcomp_2024-08-30_2300_BBSS_M1toM1: Oli's TF model to measurement comparison with different physical d1 +- mm distances. Pitch here is the most important. We want to empically fit the model to the measurement but we do not yet know the absolute height of the calibration block in model terms.
allbbss_2024-jan05vJuly12Aug30_X1SUSBS_M1_ALL_ZOOMED_TFs: Oli's Drift v. No Drift v. Model Comparison. Oli is planning on posting an alog both with this information and the d1 distance comparisons once we ascertain calibration block absolute units.
Images attached to this report
Non-image files attached to this report
Comments related to this report
oli.patane@LIGO.ORG - 16:19, Saturday 07 September 2024 (79969)

Update to the triplemodelcomp_2024-08-30_2300_BBSS_M1toM1 file Ibrahim attached - there is an update to the legend. In that version I had the description for the July 12th measurement as 'New wire loop, d1=-1.5mm, no F1 drift', but there was actually F1 drift during that measurement - it had just started over a week before so the OSEM values weren't declining as fast as they had been earlier that week. I also want to be more specific as to what d1 means in that context, so in this updated version I changed July's d1 to be d1_indiv to hopefully better show that that value of -1.5mm is the same for each blade, whereas for the August measurements (now posted ) we have d1_net, because the blades heights differ by multiple .1 mms, but they still average out to the same -1.5mm.

Non-image files attached to this comment
H1 ISC
elenna.capote@LIGO.ORG - posted 16:47, Thursday 05 September 2024 - last comment - 16:33, Tuesday 10 September 2024(79939)
DARM comparison, BRUCO results post-commissioning

We made some improvements today in the sensitivity, going from about 151 Mpc on GDS CLEAN to about 158 Mpc. However, our best range from April 11th (DARM FOM reference pre-OFI disaster) is around 165 Mpc. I made a comparison of that time and now with today's commissioning improvements to see where we are still missing range. I have attached the four plot results from the darm_integral_compare results (see alog 76935 for directions).

The range integrand plot makes it much easier to see that we are still missing sensitivity around the mid-frequency band. However, the sensitivity difference shows that we lose 5 Mpc of range by 40 Hz as well. Much of this range loss seems to come from a variety of peaks that have appeared since the OFI vent, such as the 20 Hz peak. We lose another ~3 Mpc between 40-200 Hz.

I ran a bruco with GDS CALIB STRAIN CLEAN on high range time after commissioning today: post-commissioning bruco

It looks like many of these new low frequency peaks (like the large 20 Hz peak) are well witnessed by things like PSL accelerometers, indicating that they could be from jitter: PEM-CS_ACC_PSL_TABLE1_Y_DQ

Generally, there is a lot of jitter coherence, and given that this is the CLEAN channel, that's probably a sign that the jitter cleaning could be improved, maybe making use of other witness channels if the current witnesses are insufficient to subtract the noise.

A peak at 30 Hz has some coherence with MAG sensor channels, here is one: PEM-CS_MAG_LVEA_VERTEX_X_DQ

Right around 35.4 Hz, there is a lot of coherence with various ISI HAM6 sensors and OMC ASC sensors. For example: ISI-HAM6_GS13INF_V1_IN1_DQ

There is also still a large amount of LSC REFL RIN coherence up to 1 kHz: LSC-REFL_RIN_DQ

I think we should test the PRCL offset again, especially because this will help reduce the CHARD Y noise coupling (ASC-CHARD_Y_OUT_DQ) and will also possibly help this HF noise (frequency noise? intensity noise?)

SRCL is better than before, but maybe has more room for improvement between 10-25 Hz: LSC-SRCL_OUT_DQ

DHARD Y coherence is low, but still present, so we should be careful with the WFS offset: ASC-DHARD_Y_OUT_DQ

There is still PRCL coherence: LSC-PRCL_OUT_DQ which is likely coupling through a combination of CHARD Y, SRCL, and LSC REFL RIN. Again a PRCL offset will help. Other strategies are to check POP phasing, POP sensing, etc. Reminder: PRCL feedforward failed, so we need to consider other avenues for noise reduction.

To summarize some strategies to get back to April sensitivity:

Editing because I went back to check the previous PRCL offset work and found this comment: 76818, in short, we can fix the REFL RIN coherence, but it has no effect on the sensitivity. However, it can improve CHARD Y noise, although at the time I don't think we were limited by CHARD Y enough to see the low frequency benefit.

Images attached to this report
Comments related to this report
derek.davis@LIGO.ORG - 11:29, Friday 06 September 2024 (79948)DetChar, DetChar-Request

Regarding the 20 Hz line, this line disappeared from DARM yesterday (Sept 5) from roughly 12:45 - 14:15 UTC. Matching Elenna's note about coherence with PSL environmental channels, the same line disappears from the PSL microphones and accelerometers at the same time. Furthermore, there are short time windows where this line dissapears from PSL channels. This behavoir happens roughly (not the exact same gap each time) at 2 hour intervals.

These clues may be helpful for any investigation into the source of this line.  

Images attached to this comment
elenna.capote@LIGO.ORG - 15:18, Friday 06 September 2024 (79953)

Another note about PRCL Offsets and CHARD Y:

I have attached a screenshot plot comparing the PRCL offset on/off times with the noise in CHARD Y (I used the on/off times from this April alog: 76814). The PRCL offset did reduce the noise in CHARD Y a small amount, and also reduced the CHARD Y coherence with DARM. I don't think at the time of this test we were limited by CHARD Y, so we didn't actually see a change in sensitivity from this test. Therefore, it's worth trying the offset again since we seem to have more CHARD Y noise coupling right now.

Images attached to this comment
elenna.capote@LIGO.ORG - 16:33, Tuesday 10 September 2024 (80029)

Here is a comparison of a longer-span time from April and from last night's lock. Using 2 hour blocks of no-glitch time I created these darm comparison plots.

There were further small improvements in the sensitivity from when these plots were last made, so they are not completely comparable to the plots in the original alog.

These plots indicate that we have actually gained some low frequency sensitivity since April, although we are definitely seeing more peaks around low frequency than before the emergency vent. We are still missing some range around 100 Hz.

Images attached to this comment
H1 SQZ
victoriaa.xu@LIGO.ORG - posted 12:26, Wednesday 04 September 2024 - last comment - 16:39, Friday 06 September 2024(79903)
FIS at different SRCL offsets, going through 0

Naoki, Sheila, Vicky - FIS Measurements at different SRCL offsets

Setup steps:

Measurement steps:

  1. Note the SRCL offset counts: caget H1:LSC-SRCL1_OFFSET
  2. Run SCAN_SQZANG
  3. Take measurement at that SRCL offset. Note gpstime.
  4. Check adc counts to see if we can keep going. Right now, looks like each 75-count step on the SRCL offset is about 3.5k ADC counts.

All spans 60s

FIS original SRCL offset @ -175 1409509282  (reference, orginal FDS settings). Span 60s, brown

FIS SRCL offset @ -100  1409509687  (worse SRCL detuning), pink

FIS SRCL offset @ -250  1409510096  (better SRCL detuning, closer to 0), green

FIS SRCL offset @ -325  1409510096  (even better SRCL detuning), yellow

FIS SRCL offset @ -400  1409510673  (still better SRCL detuning), blue

FIS SRCL offset @ -475  1409511323  (very interesting, flipped around / crossed zero with SRCL detuning), black

No SQZ beam diverter closed 1409511600 - 1409511717

Images attached to this report
Comments related to this report
victoriaa.xu@LIGO.ORG - 16:39, Friday 06 September 2024 (79951)

Posting the analysis for this FIS + SRCL offset data, where we can compare FIS + SRCL data to QN models, to try inferring the physical SRCL detuning (in degrees) for each offset value (in counts). 

Comparing data + models for FIS at different SRCL detunings, with kHz sqz optimized - Attachment 1. This seems like a reasonable way to estimate SRCL detuning.

  • Previously at -175 cts, it was likely around +0.3 deg. Now at -290 cts, it is likely around -0.08 deg. Note these measurements were taken over ~40 minutes, but it only uses ~2 min of data at each setting, so this could be faster.
  • These plots show the measured squeezing dBs after subtracting non-quantum noise based on an unsqz noise model. Data = circles. GWINC QN models = solid lines. In models, the SRCL detuning is just set to qualitatively match the sqz data (by-eye). Red dashed trace shows a reference at 0-degree detuning.
  • For calculating the qn models in gwinc: at each srcl detuning, the sqz angle is fit to minimize kHz sqz. Just like how, in real life, we minimized kHz sqz at each SRCL detuning for the measurements. That is, kHz sqz is minimized in both measured data and in qn models, so the data+models can be readily compared.
    • It seems like you could get a good signal on this if optimizing bucket squeezing because kHz sqz would be a good lever arm. But based on this week, that seems potentially harder as 1) harder to optimize sqz angle in real life (noisy/slow as it requires more averaging to optimize 350 hz noise, leaves more room for meas error) and 2) potentially more complicated to model, because in the models, the sqz angle needs to match the one used in the measurement at each srcl detuning.

Comparing FIS models at various SRCL detunings + fit how SRCL offset scales from counts to degrees - Attachment 2

  • Left panel shows that around 0-degree srcl detuning, the differences in squeezing are very marginal and hard to see (compare the red / yellow / green traces).
    • From this plot, we can see why we thought blue = -400 cts trace was a reasonable point to try yesterday in lho79929 -- that setting seems to minimize 100 Hz noise if we only had FIS. But we have FDS, where the anti-squeezed quantum noise below 100 Hz should be "taken care of" by the FC. So, seems reasonable to aim for zero detuning.
  • Right panel shows a fit of SRCL offset from counts to degrees, fit suggests -274 counts would minimize the detuning; we set it at -290 this week in lho79929, so very close to 0! Note that the different signs of the SRCL detuning seem to impact squeezing quite differently.

So far this code is living here.

Here also reproducing the list of times I used for the analysis, all span = 120 seconds. Also including the SRCL offset in counts of the filter bank, and the corresponding estimated SRCL detuning based on FIS quantum noise models, with khz squeezing angle minimized.

nosqz: 1409511600
FIS -100: 1409509687, pink.        ~~> +0.9 deg
FIS -175: 1409509282, brown.    ~~> +0.3 deg
FIS -250: 1409510096, green.     ~~> +0.1 deg
FIS -325: 1409510392, orange.  ~~> -0.1 deg
FIS -400: 1409510673, blue.       ~~> -0.5 deg
FIS -475: 1409511323, black.     ~~> -1.1 deg

Images attached to this comment