I ran a cal measurement starting at 01:37UTUC finishing at 02:02UTC. We've been locked and observing all night, just over 17 hours.
I ran a cal sweep starting at 01:37UTC
Simulines:
/ligo/groups/cal/H1/measurements/PCALY2DARM_BB/PCALY2DARM_BB_20240101T013307Z.xml saved
BB:
GPS start: 1388108334
2024-01-01 02:01:02,922 | INFO | File written out to: /ligo/groups/cal/H1/measurements/DARMOLG_SS/DARMOLG_SS_20240101T013839Z.hdf5
2024-01-01 02:01:02,940 | INFO | File written out to: /ligo/groups/cal/H1/measurements/PCALY2DARM_SS/PCALY2DARM_SS_20240101T013839Z.hdf5
2024-01-01 02:01:02,950 | INFO | File written out to: /ligo/groups/cal/H1/measurements/SUSETMX_L1_SS/SUSETMX_L1_SS_20240101T013839Z.hdf5
2024-01-01 02:01:02,960 | INFO | File written out to: /ligo/groups/cal/H1/measurements/SUSETMX_L2_SS/SUSETMX_L2_SS_20240101T013839Z.hdf5
2024-01-01 02:01:02,971 | INFO | File written out to: /ligo/groups/cal/H1/measurements/SUSETMX_L3_SS/SUSETMX_L3_SS_20240101T013839Z.hdf5
GPS stop: GPS: 1388109681
TITLE: 12/31 Day Shift: 16:00-00:00 UTC (08:00-16:00 PST), all times posted in UTC
STATE of H1: Observing at 152Mpc
INCOMING OPERATOR: Ryan C
SHIFT SUMMARY:
Very quiet day today. H1 was locked and observing the whole shift; current lock stretch is just over 13 hours.
TITLE: 12/31 Eve Shift: 00:00-08:00 UTC (16:00-00:00 PST), all times posted in UTC
STATE of H1: Observing at 151Mpc
OUTGOING OPERATOR: Ryan S
CURRENT ENVIRONMENT:
SEI_ENV state: CALM
Wind: 4mph Gusts, 2mph 5min avg
Primary useism: 0.02 μm/s
Secondary useism: 0.31 μm/s
QUICK SUMMARY:
State of H1: Observing at 154Mpc
H1 has been locked and observing for 9.5 hours. Quiet morning so far after walking through the MSR and GC server rooms.
Ryan, Richard, Dave:
The GC UPS reported time on battery this morning between 06:53:56 - 06:54:01 PST.
Attached fast mains mon channels show a slight dip in voltage for all three phases as seen in the corner station, lasting for only about 5 cycles. H1 and CDS rode through this with no issues, H1 stayed locked.
Ryan walked the MSR and GC server rooms, nothing untoward was found.
Sun Dec 31 10:07:11 2023 INFO: Fill completed in 7min 7secs
TITLE: 12/31 Day Shift: 16:00-00:00 UTC (08:00-16:00 PST), all times posted in UTC
STATE of H1: Observing at 153Mpc
OUTGOING OPERATOR: TJ
CURRENT ENVIRONMENT:
SEI_ENV state: CALM
Wind: 3mph Gusts, 2mph 5min avg
Primary useism: 0.03 μm/s
Secondary useism: 0.30 μm/s
QUICK SUMMARY:
H1 has been locked and observing for 5.5 hours. All systems look good and microseism band is continuing to fall.
TITLE: 12/31 Eve Shift: 00:00-08:00 UTC (16:00-00:00 PST), all times posted in UTC
STATE of H1: Observing at 156Mpc
INCOMING OPERATOR: TJ
SHIFT SUMMARY: Quiet shift, locked the whole night 11hours as of 00:00UTC. Microseism continues to decrease.
STATE of H1: Observing at 156Mpc
We've been locked for 7:00
TITLE: 12/30 Eve Shift: 00:00-08:00 UTC (16:00-00:00 PST), all times posted in UTC
STATE of H1: Observing at 155Mpc
OUTGOING OPERATOR: Ryan S
CURRENT ENVIRONMENT:
SEI_ENV state: CALM
Wind: 3mph Gusts, 2mph 5min avg
Primary useism: 0.04 μm/s
Secondary useism: 0.43 μm/s
QUICK SUMMARY:
TITLE: 12/30 Day Shift: 16:00-00:00 UTC (08:00-16:00 PST), all times posted in UTC
STATE of H1: Observing at 156Mpc
INCOMING OPERATOR: Ryan C
SHIFT SUMMARY: Some earthquakes passing through today meant H1 was down for a few hours around mid-shift, but relocking was straightforward. H1 has now been locked and observing for 3 hours.
LOG:
No log for this shift.
FAMIS 25971, last checked in alog74967
Script reports elevated high frequency noise for ITMX_ST2_CPSINF_H1
All other chambers look nominal.
FAMIS 26271, last checked in alog74986
Noise levels for all fans haven't changed since last check and are all within spec.
Lockloss @ 18:07 UTC from a M6.5 earthquake from Indonesia/Papua New Guinea. Holding H1 in DOWN at least until it fully passes.
H1 back to observing at 21:03 UTC
Sat Dec 30 10:08:40 2023 INFO: Fill completed in 8min 37secs
TITLE: 12/30 Day Shift: 16:00-00:00 UTC (08:00-16:00 PST), all times posted in UTC
STATE of H1: Observing at 156Mpc
OUTGOING OPERATOR: TJ
CURRENT ENVIRONMENT:
SEI_ENV state: CALM
Wind: 2mph Gusts, 1mph 5min avg
Primary useism: 0.05 μm/s
Secondary useism: 0.50 μm/s
QUICK SUMMARY:
H1 has been locked and observing for 1.5 hours. All systems look good; heavy fog on site this morning.
TITLE: 12/30 Eve Shift: 00:00-08:00 UTC (16:00-00:00 PST), all times posted in UTC
STATE of H1: Observing at 155Mpc
INCOMING OPERATOR: TJ
SHIFT SUMMARY: We were locked the whole shift, 12:45.
Around 00:00UTC Tony popped into the VPW to check on the fans.
DIAG_MAIN message: SERVO_BOARDS: IMC-REFL_SERVO_SPLITMON > 8V during an EQ around 03:38UTC
I kept getting the following error every time I run verbal alarms on opslogin0:
Could not connect to GRD-/usr/lib/python3/dist-packages/gpstime/leaps.py:110:_ERROR
STATE of H1: Observing at 156Mpc
We've been locked for 8:45