oli.patane@LIGO.ORG - posted 22:04, Saturday 24 August 2024 (79696)
Ops Eve Shift End

TITLE: 08/25 Eve Shift: 2300-0800 UTC (1600-0100 PST), all times posted in UTC
STATE of H1: Observing at 139Mpc
INCOMING OPERATOR: Tony
SHIFT SUMMARY: Currently Observing and have been Locked for over 10.5 hours. Shift has been quiet. Since Corey said relocking this morning was hands-off and smooth, so hopefully that'll continue through the night.
LOG:

23:30 Observing and have been Locked for over 5 hours
00:02 Verbal: "WAP on in LVEA, EX, EY" (Last time this happened that I could find was mid-May 77860)

H1 General
oli.patane@LIGO.ORG - posted 20:42, Saturday 24 August 2024 (79695)
Ops mid shift summary

Currently Observing and have been Locked for 9.5 hours. Since getting back to Observing we haven't had any issues!

H1 General
oli.patane@LIGO.ORG - posted 16:40, Saturday 24 August 2024 (79694)
Ops Eve Shift Start

TITLE: 08/24 Eve Shift: 2300-0800 UTC (1600-0100 PST), all times posted in UTC
STATE of H1: Observing at 135Mpc
OUTGOING OPERATOR: Corey
CURRENT ENVIRONMENT:
    SEI_ENV state: CALM
    Wind: 21mph Gusts, 15mph 5min avg
    Primary useism: 0.12 μm/s
    Secondary useism: 0.09 μm/s
QUICK SUMMARY:

Observing and have been Locked for 5.5 hours!

Completed tasks:

Calibration (unthermalized): 79676

Calibration (1.5 hours in): 79689

Calibration (fully thermalized): 79691

LSCFF measurements: 79693

LHO General
corey.gray@LIGO.ORG - posted 16:29, Saturday 24 August 2024 - last comment - 08:17, Monday 26 August 2024(79683)
Sat DAY Ops Summary

TITLE: 08/24 Day Shift: 1430-2330 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Lock Acquisition
INCOMING OPERATOR: Oli
SHIFT SUMMARY:

Have had the BS camera die on us a couple times in the last 24hrs (this requires contacting Dave to restart the camera's computer--atleast until this camera can be moved to another computer), and so the beginning of the shift was restoring this and also figuring out why H1 had a lockloss, BUT did not drop the Input Power down from 61W to 2W.

After the camera issue was fixed, ran an alignment with no issues, and then took H1 all the back to NLN also with no issues.  

Then completed taking Calibration measurements after 1.5hrs and 3hrs.  Oli also ran LSC Feedforward measurements......

Then there was ANOTHER BS Camera Computer Crash!  Dave brought us back fast.  

Now back to OBSERVING!
LOG:

Comments related to this report
ryan.short@LIGO.ORG - 08:17, Monday 26 August 2024 (79707)ISC, OpsInfo

Looking into why the input power didn't come back down after a lockloss at ADS_TO_CAMERAS, seems that the proper decorators that check for a lockloss are missing from the run method (but are there in main). This means that while ISC_LOCK was waiting for the camera servos to turn on, it didn't notice that the IFO lost lock, and therefore didn't run through the LOCKLOSS or DOWN states which would reset the input power.

I've added the decorators to the run method of ADS_TO_CAMEARS so this shouldn't happen again.

 

H1 ISC
oli.patane@LIGO.ORG - posted 15:59, Saturday 24 August 2024 (79693)
LSCFF measurements Aug 24, 2024

3.5 hours into our lock we took LSCFF measurements. Files can be found in /opt/rtcds/userapps/release/lsc/h1/scripts/feedforward/ and are basically the name of the measurement template+'_20240824', but I'll list their filenames below anyway.

MICH Preshaping (run as 30 fixed averages)
MICHFF_excitation_ETMYpum_20240824.xml
MICHFF (30 accumulative averages)
MICH_excitation_20240824.xml

SRCL Preshaping (32 accumulative averages)
SRCLFF_excitation_ETMYpum_20240824.xml
SRCLFF (30 accumulative averages)
SRCL_excitation_20240824.xml

PRCLFF (30 accumulative averages)
PRCL_excitation_20240824.xml

H1 CAL (CAL)
corey.gray@LIGO.ORG - posted 14:50, Saturday 24 August 2024 (79691)
H1 Calibration Measurement Run After 3.0hrs at NLN (broadband headless + simulines)

For H1 recovery road back to Observing, it was requested to take calibrations (1) immediately at NLN, (2) 1.5hrs after NLN, and then the (3) standard one of atleast 3hrs after NLN.

Measurement NOTES:

Now that this is complete, we can cross this off the white board, and Oli immediately started running LSC Feed Forward measurements.

Images attached to this report
H1 General
corey.gray@LIGO.ORG - posted 14:41, Saturday 24 August 2024 (79690)
H1 Back To Observing!!!

(Corey, Oli, RyanS [remote], Sheila [remote])

After roughly 6-weeks (Jul 12, 2024), H1 made it back to Observing (at 2042utc Aug24) to join L1 & V1 (albeit briefly since we needed to drop from Observing to take a thermalized calibration measurement + LSC FeedForward offset measurement).  H1 range is only about 140Mpc.

We are running with input power setting of 61W (to help avoide PI Mode24). 

To get to Observing, SDF Diffs needed to be ACCEPTED (see attached image with all the diffs).

Images attached to this report
H1 CAL (CAL)
corey.gray@LIGO.ORG - posted 14:41, Saturday 24 August 2024 (79689)
H1 Calibration Measurement Run After 1.5hrs at NLN (broadband headless + simulines)

For H1 recovery road back to Observing, it was requested to take calibrations (1) immediately at NLN, (2) 1.5hrs after NLN, and then the (3) standard one of atleast 3hrs after NLN

Measurement NOTES:

Images attached to this report
H1 CDS
david.barker@LIGO.ORG - posted 11:16, Saturday 24 August 2024 - last comment - 15:51, Saturday 24 August 2024(79688)
h1cam26 stopped updating Fri 22:30 PDT, power cycled camera to restore it

h1cam26 (BS) was restarted Thur 12:56 PDT after stopping late Wed 22:23. It only lasted less than two days and stopped responding Fri night at 22:30.

I restarted it again this morning at 11:07 following the standard procedure.

Comments related to this report
david.barker@LIGO.ORG - 15:51, Saturday 24 August 2024 (79692)

and again...

h1cam26 stopped running at 15:25 (only ran for 4hr 18min). I power cycled camera at 15:41.

H1 ISC
corey.gray@LIGO.ORG - posted 10:49, Saturday 24 August 2024 - last comment - 11:12, Saturday 24 August 2024(79685)
Stuck At ADS TO CAMERAS Again

H1 is currently stuck at ADS TO CAMERAS (same as last night); see attached screenshot.

CAMERA SERVO node has messages of:

"ASC-CAM_PIT1 (& YAW1)_INMON is stuck!  Do Not Advance!"

Will do some searching to see what the issue is. 

NOTE:  Sheila's alog that there was mention of PIT1 being updated.

Images attached to this report
Comments related to this report
corey.gray@LIGO.ORG - 11:06, Saturday 24 August 2024 (79686)CDS

Ryan S--messaged me about the issue being the BS Camera being down (similar to alog 79648 on Thursday), so I just contacted Dave and he will be bringing this BS camera back up.

corey.gray@LIGO.ORG - 11:12, Saturday 24 August 2024 (79687)

As soon as Dave broght the camera back, I reselected CAMERA SERVO ON (for CAMERA_SERVO node) and this unstalled the node, and had ISC LOCK get us to NLN within a minute.....but of course, PI24 immediately started to ring up!  (But it looked like the SUS PI node damped it down).

H1 General
corey.gray@LIGO.ORG - posted 09:03, Saturday 24 August 2024 (79682)
H1 Lockloss, But PSL Power Remained at 61W (so that all went to MC Refl)

Arrived to see H1's ISC LOCK at ADS TO CAMERAS, but no signals on the front ndscope and no DARM line on DARM FOM.  SUS  Violin screen looked like everyone was OFF or not damping.   Eventually, the telltasign was MC Trans was flashing (so IMC was NOT locked) and MC REFL was really bright (with OPS Overview saying the PSL was at ~61W.

OK, here's a rough timeline for last night (used the handy "guardctrl log" command line command which Camilla was able to help me find; I also attached the guardtrl log for all notes for the minute around the lockloss):

I will probably run an Initial Alignment and return to the game plan of locking H1 and running measurements at NLN.

Images attached to this report
Non-image files attached to this report
LHO VE
david.barker@LIGO.ORG - posted 08:20, Saturday 24 August 2024 - last comment - 08:38, Saturday 24 August 2024(79680)
Sat CP1 Fill

Sat Aug 24 08:13:53 2024 INFO: Fill completed in 13min 49secs

Images attached to this report
Comments related to this report
david.barker@LIGO.ORG - 08:38, Saturday 24 August 2024 (79681)

TCmins were -159C for today's fill, the outside temp is down to 13C (56F). I've increased the trip temps from full-summer (-140C) to late-summer (-130C). We typically run at this level until mid October.

LHO General
corey.gray@LIGO.ORG - posted 08:00, Saturday 24 August 2024 - last comment - 11:30, Saturday 24 August 2024(79679)
Sat DAY Ops Transition

TITLE: 08/24 Day Shift: 1430-2330 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Lock Acquisition
OUTGOING OPERATOR: n/a
CURRENT ENVIRONMENT:
    SEI_ENV state: CALM
    Wind: 5mph Gusts, 3mph 5min avg
    Primary useism: 0.01 μm/s
    Secondary useism: 0.11 μm/s
QUICK SUMMARY:

Trying to figure out the state of H1, it was in automatic operation and is currently stuck at ADS_TO_CAMERAS since before 11pm local.  (My main confusion is why I don't see any signals on nuc 30 (no DARM signal and no signals on the PRMI.sb ndscope.  I also don't see Odd.)

WAIT. 

OK, H1 is DOWN, but Guaridian seems to think it's trying to get thru ADS to Cameras and Inject Squeezing.....my realization is that MC Trans was flashing!  Then I saw that MC Refl is really bright (I'm assuming close to the 60.8W Guaridan had taken us to via ISC LOCK.

Comments related to this report
corey.gray@LIGO.ORG - 11:30, Saturday 24 August 2024 (79684)

With regards to the weekend operators To Do List (aka alog 79760):

Calibrations:

  • @NLN:  DONE!!!
  • @1.5hrs after NLN:  (hopefully soon!)
  • @3hrs after NLN:  :  (hopefully soon!)

Camera Set Points:

  • PIT1:  DONE!!!
  • Sheila said to skip these, and focus on getting the calibration measurements above.
H1 General (OpsInfo)
oli.patane@LIGO.ORG - posted 22:32, Friday 23 August 2024 (79678)
Ops Eve Shift End

TITLE: 08/24 Eve Shift: 2300-0800 UTC (1600-0100 PST), all times posted in UTC
STATE of H1: Corrective Maintenance
INCOMING OPERATOR: None
SHIFT SUMMARY: Currently relocking and at MOVE_SPOTS. Max power is currently 61W(in actuality we are getting 60.8W out) in lsc_params in the hopes of avoiding the new PI. High winds today made locking hard, but we finally were able to get into NLN for an hour, and we were able to take (unthermalized) calibration measurements(79676), as well as figure out where the new PI is from and started trying to update the camera offsets. While trying to run the script that checks for the best camera offset locations, we lost lock, and I have been trying to get us relocked since then. We kept having locklosses in the middle states (~200-420s), and this last time Sheila recommeded fixing alignment by sitting in OFFLOAD_DRMI_ASC and adjusting SRM and PRM to raise POP18 and lower POP90 (altough I mostly focused on raising POP18), and adjusting it seems to have helped us get part this trouble area. Also, OMC_LOCK has been having a little trouble locking the cavity, but it will eventually catch on its own. For tonight, I am setting H1_MANAGER to LOW_NOISE, but leaving IFO_NOTIFY off.
LOG:

23:30 Just lost lock from LOWNOISE_ASC
00:59 NOMINAL_LOW_NOISE
01:06 Went to NLN_CAL_MEAS to run calibration
01:35 Calibration measurements finished, went back to NLN_CAL_MEAS
02:00 Lockloss
    02:13 Lockloss from ACQUIRE_DRMI_1F
    02:24 Lockloss from CHECK_MICH_FRINGES
    02:26 Started an initial alignment
    03:05 Initial alignment done, relocking
    03:20 Lockloss from RESONANCE
    03:50 Lockloss from CARM_150_PICOMETERS
    04:01 Lockloss from RESONANCE
    04:13 Lockloss from CARM_TO_REFL
    04:22 Lockloss from ENGAGE_DRMI_ASC    
        - Starting an initial alignment
    04:41 Initial alignment done, relocking
    04:53-04:58 Sat in OFFLOAD_DRMI_ASC and adjusted SRM and PRM to raise POP18

H1 CAL
oli.patane@LIGO.ORG - posted 18:41, Friday 23 August 2024 (79676)
Unthermalized Calibration Measurements Aug 24, 2024

** These calibration measurements were started a few minutes after reaching NLN. The IFO was NOT thermalized!!

Calibration monitor screenshot

Broadband (2024-08/24 01:06 - 01:11 UTC)

File:

/ligo/groups/cal/H1/measurements/PCALY2DARM_BB/PCALY2DARM_BB_20240824T010639Z.xml
 

Simulines (2024/08/24 01:13 - 01:35 UTC)

Screenshot of simulines error from the end of the measurement

Files:

/ligo/groups/cal/H1/measurements/DARMOLG_SS/DARMOLG_SS_20240824T011302Z.hdf5
/ligo/groups/cal/H1/measurements/PCALY2DARM_SS/PCALY2DARM_SS_20240824T011302Z.hdf5
/ligo/groups/cal/H1/measurements/SUSETMX_L1_SS/SUSETMX_L1_SS_20240824T011302Z.hdf5
/ligo/groups/cal/H1/measurements/SUSETMX_L2_SS/SUSETMX_L2_SS_20240824T011302Z.hdf5
/ligo/groups/cal/H1/measurements/SUSETMX_L3_SS/SUSETMX_L3_SS_20240824T011302Z.hdf5

Images attached to this report