LVEA was swept. Lights, WAP, paging system all off. Found nothing extra plugged in apart from usual PEM equipment.
There are a few unconnected BNCs connected to the PSL/SQZ racks that aren't being used. Some tools left on HAM5 pier -X+Y pier (didn't remove as in the middle of locking). SQZ bay crane is a few meters off it's parking spot. Farro is now plugged in near SQZ racks. Large clean-room in the +Y bay is plugged in but off (doubt this has changed).Still long extension cord to HAM3 dust monitor.
I am taking another look at what steps in lock acquisition take a very long time. See Georgia's previous alog on this: 76398
I noticed some of the power up steps seem to take longer than they should. I found some timers that are longer than necessary, so I am shortening them.
Just a note about many of the longer waits and tight convergence thresholds: powering up to 75 W was sometimes a very shaky process that required a much tighter convergence in the soft loops, otherwise runaway instabilities would often cause locklosses. We have previously relaxed some of these tight constraints to speed up lock but we didn't catch them all. This should take care of more of them (but maybe not all).
Naoki, Vicky, Camilla
After the vent, we can reach NLN, but we have locklosses from PI24 at 10.431 kHz. The SUS_PI guardian tries to damp, but it does not help. Vicky checked that the frequency of this PI is 10431.03 Hz as shown in the attachment. This is within the input bandpass filter (428.5-433.5 Hz after downconversion by 10kHz).
We tried to excite the PI24 with ETMY. We used awggui and sent a sine wave at 431 Hz to H1:SUS-PI_PROC_COMPUTE_MODE24_BP_EXC. We could excite/damp the PI24 RMSMON by changing the damping phase so PI damping should work. We increased the damping gain for PI24 from 1000 to 10000, which is set by SUS_PI guardian.
Fri Aug 23 08:15:20 2024 INFO: Fill completed in 15min 15secs
TITLE: 08/23 Day Shift: 1430-2330 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Corrective Maintenance
OUTGOING OPERATOR: Tony
CURRENT ENVIRONMENT:
SEI_ENV state: CALM
Wind: 3mph Gusts, 2mph 5min avg
Primary useism: 0.01 μm/s
Secondary useism: 0.10 μm/s
QUICK SUMMARY:
IFO is in DOWN and MAINTENANCE
Continguing our work on tuning the IFO for observing following the recent vent
TITLE: 08/23 Eve Shift: 2300-0800 UTC (1600-0100 PST), all times posted in UTC
STATE of H1: Corrective Maintenance
INCOMING OPERATOR: Tony
SHIFT SUMMARY:
Took over from Tony at 6pm local (1utc) who was covering the first part of my shift.
Elenna was getting H1 to NLN, well to the Inject Squeezing state, so she could hand off to Naoki for Squeezer optimization.
H1 eventually made it to NLN and range was approaching 140Mpc, but then PI Mode 24 rung up againand had a lockloss (even with PI DAMPING for SUSPI).
At any rate, with the lockloss, took the opportunity to run an Intial Alignment to capture the green references that Elenna got earlier today. (I did have touch up SR2+SRM alignment by hand for SRC_ALIGN_OFFLOADED.)
Oh, also made the edit to ISC_LOCK to 'not' skip the SHUTTER ALS step.
The first attachment shows the DARM with/without squeezing today (blue: with squeezing, orange: without squeezing). The range is ~140 Mpc with squeezing and ~124 Mpc without squeezing.
Above 1 kHz, DARM with squeezing is as good as the start of O4b and we have 4.8 dB squeezing at 2 kHz. The DARM below 1 kHz is worse and we will need to optimize FF and fix the calibration. We may also need to optimize PSAMS to improve the bucket sensitivity.
I ran SCAN_ALIGNMENT_FDS three times and accepted SDF as shown in the second attachment.
Both the X and Y arm green references have been set! Please run a full initial alignment at the next lockloss.
The X arm green references have been set several times and have stayed fairly the same; only the Y arm references have been an issue.
Procedural notes:
Green references steps:
SDFs for ALS X and Y are attached. The ALS X values have stayed fairly similar, and the ITMX CAM Yaw value I measured was exactly the same as the previous, so it did not appear as an SDF diff.
Final notes:
Today's activities: - HAM7 turbo was valved out, and switched off. This pump needs ~3 hrs to spin down - Immediately after this, FCV-2 was opened, so HAM7 was connected with the main volume via BSC3 - Then, RV1 (relay-tube remaining valve), FCV-4 and FCV-3 (valves towards HAM8 along the FCT) have been also opened - Later, after the HAM7 turbo spun down, the backing supersucker cart was disconnected from it - During the day, HAM6 RGA bakeout was ramped down. This RGA tree was also valved together with a small Ion-pump, which always keeps it under UHV. - This RGA's filaments were also fired up. RGA scans of its small volume will be done in the upcoming days, then it will be valved together with the main volume (HAM6), and RGA scans will be done of HAM6, and these scans will be compared with the Corner RGA scan results So, the interferometer is now fully open. The exact pumpdown time (from the start of the roughing to the opening of large GVs) was 14 days 17.25 hours. This is by far the shortest pumpdown so far. In dcc T2400085 the pumpdown will be more thoroughly analyzed, and will be compared with past pumpdowns, especially with the last one during February of 2024. The pressures: Corner (PT-120 and PT131): 6.3E-8 Torr HAM6: 2.4E-7 Torr HAM7: 1.25E-7 Torr CP1: ~2.5E-8 Torr CP2: ~5E-8 Torr
I reverted the Changes to ALS_ARM.py that were put in today because the DOF2 WFS were not working.
TITLE: 08/23 Eve Shift: 2300-0800 UTC (1600-0100 PST), all times posted in UTC
STATE of H1: Corrective Maintenance
OUTGOING OPERATOR: Ryan S
CURRENT ENVIRONMENT:
SEI_ENV state: CALM
Wind: 16mph Gusts, 11mph 5min avg
Primary useism: 0.04 μm/s
Secondary useism: 0.08 μm/s
QUICK SUMMARY:
Slowly going Locking states so commisioners can fine tune full IFO Y Arm alignment , by stepping through PREP_ASC_FORFULL_IFO[429] manually. This is to set the Y arm Green reference & document settings.
Naoki, Vicky, Camilla, Sheila. Copied instructions from 78115.
Today we couldn't find the SQZ beam while the IFO was locked using SQZ-OMC_TRANS_RF3_DEMOD_RFMON as we'd been ale to do in 78088. When the IFO unlocked we used the SQZ SEED beam in a SQZ single bounce (much higher power so easier to see) to improve the SQZ alignment. Expect when we're locked will still need to touch alignment, may get away with a few rounds of SQZ_MANAGER's SCAN_ALIGNMENT_FDS state (wiki notes). Notes below.
TITLE: 08/22 Day Shift: 1430-2330 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Corrective Maintenance
INCOMING OPERATOR: Corey
SHIFT SUMMARY: Another busy day of IFO recovery. See Elenna's alog for a summary of the morning's activities.
Since then, H1 lost lock from a ringup of PI mode 24. Naoki, Camilla, and the SUS_PI Guardian all tried to damp it down to no avail; why do we now have a PI that we cannot damp?
After the lockloss, we started back with troubleshooting ALS issues while team SQZ worked on recovering their alignment. TJ and I tried to find an arm alignment that both had the arm power and NSUM counts on ALSY WFS_B high, but we weren't successful. Eventually, Keita was able to help us recenter on both WFS A and B by adjusting the biases for both PZTs on the ISCEY table (found on the secret ALS-Y_WFS Auto Centering medm screen) after we locked the arm in green. These new bias settings ahve been accepted in the ALSEY SAFE.snap SDF table (screenshot attached). It turns out that with the centering being so off on the ALSY WFS, the auto-centering servo was railing, which didn't allow the ALS WFS to engage without us forcing them to. After centering on the WFS, we took the ALS_YARM Guardian to LOCKED_SLOW_WFS_ETM_TMS and the ALSY WFS engaged properly.
The next steps will be to lock the full IFO keeping ALSY locked to set the green camera references.
LOG:
| Start Time | System | Name | Location | Lazer_Haz | Task | Time End |
|---|---|---|---|---|---|---|
| 23:58 | sys | h1 | lho | YES | LVEA is laser HAZARD | Ongoing |
| 15:11 | FAC | Kim | Labs | n | Technical cleaning | 15:45 |
| 15:35 | PEM | Sam | FCES | n | Checking PEM equipment | 15:56 |
| 16:19 | PEM | Robert, Sam | FCES | n | Check PEM equipment | 18:15 |
| 16:41 | VAC | Janos, Travis | LVEA | - | Opening HAM7 GVs | 16:58 |
| 16:50 | FAC | Tyler +3 | Y-arm | n | Beamtube sealing | 18:50 |
| 17:06 | VAC | Jordan | LVEA | - | Rampdown HAM6 RGA | 17:22 |
| 18:30 | CAL | Tony, Robert | PCal Lab | Local | Tour | 19:25 |
| 18:43 | ISC | Keita | LVEA | - | Reconnecting AS_C fast channel | 19:25 |
| 21:52 | VAC | Janos, Gerardo, Jordan | LVEA | - | Turning off RGA on HAM6 | 22:28 |
| 21:59 | AOS | Betsy | LVEA | - | Looking for equipment | 22:39 |
| 22:15 | VAC | Travis | LVEA | - | Ladder to HAM6 | 22:39 |
The transition from the piston driven (non-dried) instrument air compressor to the new (inline dried) scroll style compressor was finalized last week. The compressor is presently left at its factory set pressure of 120psi. TJ raised the high limit threshold for alarms to coincide with this change in pressure. The new system has been delivering the facility with air without issue since last week. Amidst this transition, I elected to pressurize the compressed air line between the chiller yard and mechanical room and remove any feed/demands from it as noted in my previous alog. There were no significant pressure losses over an 8-hour period and as such I have no reason to believe that the line feeding the mechanical room is in any way compromised. Not shown in the pictures: Insulation and heat trace on lines that require it and weatherproof outlet box E. Otterman C. Soike T. Guidry
Just a quick report now that we are back to NLN!
h1cam26 (BS) stopped updating around 22:22 PDT Wed 21aug2024.
I power cycled the camera via sw-lvea-aux POE and restarted the process on h1digivideo2.
h1cam26 is on switch port 0/35
The offload of the past 6 month's of raw minute trend files from h1daqtw1's SSD-RAID to permanent archival on spinning media is complete. TW1's SSD-RAID disk usage has been reduced from 92% to 2%.
First NDS1 restart: 09:56 Tue 20aug2024
Start file copy: 10:53 Tue 20aug2024
File copy completed: 12:07 Wed 21aug2024 (25hrs 14mins)
Second NDS1 restart: 15:47 Wed 21aug2024
Start file deletion on TW1: 09:32 Thu 22aug2024
File deletion complete: 11:40 Thu 22aug2024 (2hrs 8mins)
I wanted to check the last lock loss concerning the power upstream/downstream of the fast shutter, but quickly remembered that the upstream signal, i.e. the non-whitened analog version of the ASC-ASC_SUM, was disconnected from the fast PEM ADC (H1:PEM-CS_ADC_5_19_2K_OUT_DQ) before the last vent to fix OFI, and it was not reconnected since.
I went to the floor and restored the connection.
After HAM7/FC GVs were open this morning, I aligned FC1/2 and FC GR is locked. FC GR trans is ~110, which is reasonable.
I measured NLG following 76542. The measured NLG is 16 (0.247/0.0154=16), which is a bit lower than the last measurement in 78000. The OPO temperature is very different from before as shown in the attached SDF.
TITLE: 08/21 Eve Shift: 2300-0800 UTC (1600-0100 PST), all times posted in UTC
STATE of H1: Corrective Maintenance
INCOMING OPERATOR: Ryan C
SHIFT SUMMARY:
H1 made it to NLN just a few minutes after Elenna left this evening. The range is not great (~55Mpc), but H1 is at NLN (there are still noise sources on the floor due to VAC work which needs to be done. HAM7 and the rest of the Filter Cavity downstream is still valved out from the main volume (so there is also backscatter noise from the relay tube blocking light and gas from entering the Filter Cavity).
Other notes:
WFS for the Y-Arm has not worked all day. The ALSy Auto Centering AUTO state did not seem to work (it's a red box onthe ALS overview). Clicking the Force button would turn on the WFS, but they would drive off the alignment.
For locking, Because of the above, we were not able to run an Initial Alignment (but a Manual Alignment worked for all the other states...except for green arms).
Work still remains to be done for the ASC SRC loops. Elenna was able to get through this and work on it by changing SRC offsets.
Violin modes were rung up, so while Elenna was working on H1 I worked on violin mode damping. Managed to get all the violin modes into the GREEN (except for ITMy's pesky M5/6 which are currently down to YELLOW from ORANGE).
For overnight, will select H1 to stay DOWN when it loses lock.....and it appears it's going to drop out soon. H1's PI Mode 24 is currently ringing up. (SUS_PI was in the IFO_DOWN state, so the PI Modes rung up. I've taken it to PI Damping, but it's looking like it's too rung up to be damped.
LOG:
Left headlights on with my Jeep, so had to jumpstart it. Before leaving the site, I see that PI24 is slowly coming down now. (so yeah, H1's still locked!) :)
SUS_PI gets requested from 'DOWN' to 'PI_DAMPING' in ISC_LOCK state INJECT_SQUEEZING, which was skipped over last night, hence Corey needing to turn it on!
I shortened lownoise ASC further. All the ASC loop changes happen in one step. The damping loops happen in two separate steps-- the combination of the damping loops the last time we made changes to this state caused problems so those still need to be separate.This changed caused a lockloss. I have reverted the guardian code to break up these steps.