The MC3 camera image has been down since 12:10 Fri 08dec2023 PST. There was nothing wrong with the camera, it just needed a restart of the h1cam12 server process on h1digivideo1. I killed the process and let monit restart a new one.
TITLE: 12/11 Day Shift: 16:00-00:00 UTC (08:00-16:00 PST), all times posted in UTC
STATE of H1: Observing at 156Mpc
OUTGOING OPERATOR: Austin
CURRENT ENVIRONMENT:
SEI_ENV state: CALM
Wind: 11mph Gusts, 9mph 5min avg
Primary useism: 0.04 μm/s
Secondary useism: 0.22 μm/s
QUICK SUMMARY:
TITLE: 12/11 Eve Shift: 00:00-08:00 UTC (16:00-00:00 PST), all times posted in UTC
STATE of H1: Lock Acquisition
INCOMING OPERATOR: Austin
SHIFT SUMMARY: Just got back into Observing at 07:59UTC after relocking. Two locklosses during my shift, but both were quick to recover from. SEI_CONF is back to WINDY since USEISM is down.
LOG:
00:00UTC Detector Observing and Locked for 17.5 hours
00:47 Lockloss (74725)
-- Relocking --
00:58 Manually aligned green arms, and then started an Initial Alignment
01:21 Initial Alignment completed, relocking
- Watched ISC_LOCK log, ADS, and saturation overview screen closely between LOWNOISE_COIL_DRIVERS and LOWNOISE_LENGTH_CONTROL in case we lost lock during TRANSITION_FROM_ETMX, but we were fine
02:00 NOMINAL_LOW_NOISE
-- Relocking End --
02:06 Observing
04:10 Changed SEI_CONF to WINDY due to lowering useism
- Went into the SEI_ENV code beforehand and swapped the SEI_CONF nominal states back to WINDY and EARTH_QUAKE from USEISM and USEISM_EARTHQUAKE(see 74727).
00:47 Lockloss (74728)
-- Relocking --
07:18 Earthquake mode activated due to incoming earthquake from Tonga
07:28 Back to CALM
07:55 NOMINAL_LOW_NOISE
-- Relocking End --
07:59 Observing
Start Time | System | Name | Location | Lazer_Haz | Task | Time End |
---|---|---|---|---|---|---|
01:00 | PEM | Robert | LVEA | Y | Turn off laser vibrometer | 01:18 |
Lockloss 12/11 @ 06:46UTC due to sudden nearby ground motion
Observing at 160Mpc and have been Locked for 2 hours. Relocking after the lockloss (74725) went quickly, and ITMY5/6 are still damping well with Ryan C's new gain settings(74721)!
04:10UTC Secondary microseism is now consistantly below 0.8 um/s(ndscope), so I just went into the SEI_ENV code and swapped the SEI_CONF nominal states back to WINDY and EARTH_QUAKE from USEISM and USEISM_EARTHQUAKE(screenshot of change). I then changed SEI_CONF to WINDY.
Lockloss 12/11 00:47UTC for unknown reasons. EX saturation right before lockloss, and the light on the MC_REFL camera got much brighter than I had ever noticed before.
02:06UTC Observing
TITLE: 12/11 Eve Shift: 00:00-08:00 UTC (16:00-00:00 PST), all times posted in UTC
STATE of H1: Observing at 159Mpc
OUTGOING OPERATOR: Ryan C
CURRENT ENVIRONMENT:
SEI_ENV state: CALM
Wind: 5mph Gusts, 4mph 5min avg
Primary useism: 0.03 μm/s
Secondary useism: 0.29 μm/s
QUICK SUMMARY:
Detector Locked for 17.5hours and Observing. I'll keep an eye on the new violin settings.
TITLE: 12/10 Day Shift: 16:00-00:00 UTC (08:00-16:00 PST), all times posted in UTC
STATE of H1: Observing at 158Mpc
INCOMING OPERATOR: Oli
SHIFT SUMMARY: Quiet day, locked for 17:30 as of 0:00UTC.
I've finally found some settings that seem to work nicely for ITMY modes5/6, FM6+FM7+FM10 G= +0.02. They're trending down on broad, and narrow monitor filters, and on DTT. Tagging SUS
21:29UTC GRB-Short E458001
LOG:
Start Time | System | Name | Location | Lazer_Haz | Task | Time End |
---|---|---|---|---|---|---|
16:31 | FAC | Richard | CP1 | N | Grab the van | 16:36 |
21:00 | FAC | Richard | CP1 | N | Plug in van | 21:10 |
STATE of H1: Observing at 159Mpc
Sun Dec 10 10:04:21 2023 INFO: Fill completed in 4min 18secs
TITLE: 12/10 Day Shift: 16:00-00:00 UTC (08:00-16:00 PST), all times posted in UTC
STATE of H1: Observing at 159Mpc
OUTGOING OPERATOR: Austin
CURRENT ENVIRONMENT:
SEI_ENV state: CALM
Wind: 3mph Gusts, 2mph 5min avg
Primary useism: 0.04 μm/s
Secondary useism: 0.45 μm/s
QUICK SUMMARY:
TITLE: 12/10 Eve Shift: 00:00-08:00 UTC (16:00-00:00 PST), all times posted in UTC
STATE of H1: Observing at 158Mpc
INCOMING OPERATOR: Austin
SHIFT SUMMARY: Currently Observing and have been Locked for 1.5hours. One lockloss during shift while I was running a Simulines measurement, so not sure if that could have/did cause it?
I have just left the ITMY Mode5 gain as 0 since it seemed like whenever I tried to change it, it would cause mode 5 to jump up and would take hours to get back to where it was before I turned on the gain. Mode 5 slope after changing gain from 0 -> -0.01 seemed to stay the same as well, and it seems like it takes a few hours after relocking for mode5 to start coming down.
LOG:
-- Relocking --
00:00UTC Detector relocking at ACQUIRE_DRMI_1F
- I manually took us state-by-state between LOWNOISE_ASC and TURN_ON_CALIBRATION_LINES due to TRANSITION_FROM_ETMX causing multiple locklosses for Ryan C earlier in the day (74704, 74703).
00:42 Reached NOMINAL_LOW_NOISE
-- Relocking End --
00:46 Observing
03:50 GRB-Short E457962 - Marked as NOT_GRB
04:22 I took us out of Observing and to NLN_CAL_MEAS for Calibration Measurements
04:22 Started Calibration measurements
04:45 Lockloss during calibration measurements (74716)
-- Relocking --
04:58 Low temperature alarm at MX (Went to/below 60F)
05:07 Lockloss from PRMI_ASC
- Had been struggling in DRMI and PRMI for a bit beforehand
05:11 I started an Initial Alignment
05:45 Initial Alignment complete, starting relocking
- Manually took us state-by-state between LOWNOISE_ASC and TURN_ON_CALIBRATION_LINES again
06:28 Reached NOMINAL_LOW_NOISE
-- Relocking End --
06:33 Observing
**Running measurements Saturday evening due to not being unable at our earlier scheduled time due to multiple earthquake locklosses.
*** Lockloss occured while running Simulines
Calibration Monitor screenshot
Broadband Measurements (20231210T042257Z)
2023/12/10 04:22:57 (1386217395) Broadband measurement started
2023/12/10 04:28:13 (1386217711) Broadband measurement finished
Output file: /ligo/groups/cal/H1/measurements/PCALY2DARM_BB/PCALY2DARM_BB_20231210T042257Z.xml
Simulines Measurements
2023/12/10 04:29:33 (1386217791) Simulines started
2023/12/10 04:45:56 (1386218774) Lockloss and inpromptu Simulines finish so no output files :(
Lockloss 12/10 @ 04:45UTC while running Simulines calibration measurement
06:33UTC Observing
Locked for 3.5hours and Observing at 156Mpc. Relocking at the start of my shift went fine, and the ITMY5/6 violins are starting to all slowly decrease. Since Ryan didn't get to run a calibration measurement earlier today and LLO is down, I will now be starting the measurements since we've been up for 3.5 hours.
TITLE: 12/10 Eve Shift: 00:00-08:00 UTC (16:00-00:00 PST), all times posted in UTC
STATE of H1: Lock Acquisition
OUTGOING OPERATOR: Ryan C
CURRENT ENVIRONMENT:
SEI_ENV state: CALM
Wind: 6mph Gusts, 3mph 5min avg
Primary useism: 0.05 μm/s
Secondary useism: 0.69 μm/s
QUICK SUMMARY:
Detector is currently relocking and at ACQUIRE_DRMI_1F. Hopefully the Iceland earthquakes are done for today!
00:46UTC Back Observing
I used most of todays commissioning time for shaking and laser vibrometry to inform plans for the break. I replaced the MC3 camera over the viewport I had been using but couldnt get it to work. We will have to revisit it on a Tuesday.
The MC3 camera was brought back by Dave restarting the camera's server. alog74734
Also Verbals just announced an incoming 6.1 earthquake from Tonga, so I will attempt to get us back up but we might lose lock on the way up due to the earthquake.