david.barker@LIGO.ORG - posted 09:10, Tuesday 26 March 2024 - last comment - 09:12, Tuesday 26 March 2024(76707)
h1calcs model change, added CALIB_REPORT slow channels

WP11786

Jeff, Joe, Jonathan, Dave

A new h1calcs model was installed, this adds two slow channels

++: slow channel H1:CAL-CALIB_REPORT_HASH_INT added to the DAQ
++: slow channel H1:CAL-CALIB_REPORT_ID_INT added to the DAQ
 

A DAQ restart was required.

Comments related to this report
jonathan.hanks@LIGO.ORG - 09:12, Tuesday 26 March 2024 (76708)
As per ECR E1700387 these two channels were added to the h1daqgds[01] GDS broadcast streams.  The h1daqgds[01] systems where restarted again as part of this process.  This was around 8:50 am local time.
H1 CDS
david.barker@LIGO.ORG - posted 09:09, Tuesday 26 March 2024 - last comment - 09:15, Tuesday 26 March 2024(76706)
HAM SUS and ISI model restarts

WP11743 SUS DACKILL removal

Jeff, Oli, TJ, Dave:

This morning we installed new HAM SUS and ISI models:

h1susmc[1,2,3], h1suspr[m,2,3], h1sussr[m,2,3], h1susfc[1,2], h1isiham[2,3,4,5]

All required a DAQ restart.

Comments related to this report
david.barker@LIGO.ORG - 09:15, Tuesday 26 March 2024 (76709)

For h1sush2a and h1sush34, because we restarted all the user models, I elected to restart the IOP models as well to run a DAC AUTOCAL on these front ends. For all the other frontends, only the modified user models were restarted.

H1 SUS (ISC, SEI, SUS)
jeffrey.kissel@LIGO.ORG - posted 08:12, Tuesday 26 March 2024 (76703)
HAM SEI and HAM Triple SUS Prepped for Model Restarts
J. Kissel, T. Shaffer
ECR E1700387
IIET 9392
WP 11743

In prep for today's watchdog upgrades (LHO:76696), TJ and I have 
   - Ensured all HAM triple SUS have their alignment offsets accepted / stored in their safe.snap (they're typically unmonitored, so this takes special action)
   - Brought the IMC guardian to OFFLINE, and brought the guardian to "AUTO" such that it's no longer managed by ISC_LOCK
   - Brought the MC2, PRM, PR2, SR2, SRM gguardians to "AUTO" such that they're no longer managed
   - Brought MC1, MC2, MC3, PRM, PR2, PR3, SRM, SR2, SR3, FC1, and FC2 to SAFE
   - Brought SEI MANAGER guardians for HAM2, HAM3, HAM4, HAM5, HAM7, and HAM8 to ISI_DAMPED_HEPI_OFFLINE

We're ready for restarts!
LHO General
thomas.shaffer@LIGO.ORG - posted 08:01, Tuesday 26 March 2024 (76702)
Ops Day Shift Start

TITLE: 03/26 Day Shift: 15:00-23:00 UTC (08:00-16:00 PST), all times posted in UTC
STATE of H1:Maintenance
CURRENT ENVIRONMENT:
    SEI_ENV state: Maintenance
    Wind: 2mph Gusts, 2mph 5min avg
    Primary useism: 0.03 μm/s
    Secondary useism: 0.21 μm/s
QUICK SUMMARY: We lost lock at 14:41UTC, cause still to be looked at. Maintenance activities have started.

H1 General (Lockloss)
anthony.sanchez@LIGO.ORG - posted 00:11, Tuesday 26 March 2024 (76701)
Monday Ops Eve Shift Shift End

TITLE: 03/26 Eve Shift: 23:00-07:00 UTC (16:00-00:00 PST), all times posted in UTC
STATE of H1: Observing at 152Mpc
INCOMING OPERATOR: None
SHIFT SUMMARY:
Since the last mid shift report there was another lockloss at 6:08 UTC .
Once again relocking went just fine without an Initial_Alignment in 56 minutes with out intervention by the opperator.
There was a PI 31 ring up @ 6:51 UTC but while I was trying to find te right buttons to press it was supressed.

LOG:
Camilla's measurements will start Running again at 2am and continue until 6am.

H1 General (Lockloss)
anthony.sanchez@LIGO.ORG - posted 21:28, Monday 25 March 2024 (76700)
Monday Ops Eve Shift Mid Shift Report

TITLE: 03/26 Eve Shift: 23:00-07:00 UTC (16:00-00:00 PST), all times posted in UTC
STATE of H1: Observing at 152Mpc
CURRENT ENVIRONMENT:
   
SEI_ENV state: CALM
    Wind: 6mph Gusts, 4mph 5min avg
    Primary useism: 0.02 μm/s
    Secondary useism: 0.19 μm/s
QUICK SUMMARY:

Lock lasted 8 hours and 51 min
Lockloss 3:34 UTC still investigating the cause of this lockloss.
Camilla had some measurements running while we were in Observing see Alog 76695 and was concerned that perhaps her measurements had made the arm powers drop significantly. So I pulled up some ndscopes of H1:GRD-ISC_LOCK_STATE_N and the Circulating Arm powers  H1:ASC-X_PWR_CIRC_OUT16 & H1:ASC-Y_PWR_CIRC_OUT16.
I did see that the arm power did dip before H1:GRD-ISC_LOCK_STATE_N changed to a down state.

But!!! I also did the same for the Lockloss that happened this morning with out her measurement running and saw the same behavior of the Arm power dipping before the Down state was declared by ISC_LOCK. I then decided (arbitrarily) that it was reasonable to think that the time between the ISC_LOCK state change and an observed loss of 10% of the Power in the arms would be a good metric to determine if the lockloss was "Caused" by this measurement.
I have effectively convinced myself that Camilla's A2L measurements have not caused this lockloss.... but I'm open to evidence that I have overlooked.

Relocking:
I have not taken ISC_LOCK through Initial_Alignment before relocking. H1 Is alrerady back to NOMINAL_LOW_NOISE  44 Minutes from NLN to NLN with out intervention from the Operator.  49Min 9 Sec from OBSERVING to OBSERVING.


 

Images attached to this report
H1 ISC
jennifer.wright@LIGO.ORG - posted 17:45, Monday 25 March 2024 - last comment - 15:59, Monday 01 April 2024(76694)
Changing Modulation Depth

Sheila, Jennie W

At around 21:49 UTC we used the step_45MHz.py in userapps/isc/h1/scripts to step the modulation depth in steps of 1dB down from 21dBm to 18dBm. This script adjusts the loop gains to compensate for a drop in power on the RF45 PDs.

Its also important to open the POP beam diverter to monitor what is happening to the RF 45 PD signals.

This is to check that the noise does not decrease with decreasing modulation depth which would imply that the modulator was imposing noise on the carrier through the ISS loop.

At around 22:18 UTC we put the modulation depth down by 3 dB we saw a 4% increase in the DARM broadband noise (measured the level at 2kHz with cursors) which is the green trace in the second image. The level of KAPPA C (shown in first image on bottom plot) only decreased by around 1% over this time, so we suspect some other cause other than a change in optical gain being responsible for this.

When we stepped the modulation depth up by 3dB (third image) we saw no change in the noise from the nominal state (purple trace on second image). Kappa C (bottom plot) looks almost the same as the nominal also.

In the fourth image it can be seen that f_C does not change much either.

Images attached to this report
Comments related to this report
jennifer.wright@LIGO.ORG - 15:59, Monday 01 April 2024 (76854)

After we did this test Daniel commented that we should check what the PCAL lines did as we stepped down and up the 45 MHz modulation depth.

To do this I used the spectra we took and measured the height of the 410.3 Hz line (PCAL Y) in DARM in m.

Our nominal level was 1.35370 e-19 m

The line height decreased by 1.1% when we decreased the modulation depth by 3dB. I think this is consistent with our optical gain decreasing by 1%. I am therefore not sure why lowering the mod depth causes a 4% increase in DARM.

The line height increased by 0.04 % when we increased the mnodulation depth by 3dB. I think this is consistent with us not seeing much decrease in the DARM noise when we increase the modulation depth.

Images attached to this comment
H1 CAL
francisco.llamas@LIGO.ORG - posted 17:06, Monday 25 March 2024 - last comment - 17:32, Thursday 17 October 2024(76699)
Changed SDF values for Pcal Yend

DriptaB, LouisD, TonyS, FranciscoL

We noticed a 0.4% change from the value at the end of O4a for the X/Y ratio. We found alog 76562 where the Pcal EY EPICS values were changed. We have now changed them back to O4a values. See screenshot of SDF screen to find values. We will follow up with an updated value of X/Y to see if anything went wrong.

For future reference: steps to update SDF

  1. 'caput' the channels to be changed
  2. sitemap --> CAL EX(Y) --> GDS --> SDF TABLE --> ACCEPT (under select all, only afer triple checking numbers) --> CONFIRM.
  3. SDF RESTORE SCREEN --> ! SELECT REQUEST FILE --> open "safe.snap" --> LOAD TABLE. Look for differences and confirm changes if needed (was not needed for EY).
  4. Load OBSERVE.snap by following step (3).
  5. Open FORCE COEFF CALCULATION and check that changes were applied.
Images attached to this report
Comments related to this report
anthony.sanchez@LIGO.ORG - 17:32, Thursday 17 October 2024 (80736)

UPDATED Instructions!!!
For future reference: steps to update SDF

  1. 'caput' the channels to be changed
     
  2. Open OBSERVE.snap by following these steps:
    sitemap --> CAL EX(Y) --> GDS --> SDF TABLE 
     
  3. Save the new EPICS value to OBSERVE.snap:
    Find the channel that you have changed the EPICS variable for and click the ACCEPT button on the far right.  (under select all, only afer triple checking numbers).  then Please make sure you click the big green CONFIRM button.
    Open FORCE COEFF CALCULATION and check that changes were applied.
    Congratulations you just saved EPICS values to OBSERVE.snap!
     
  4. Load safe.snap by following these steps:
    SDF RESTORE SCREEN --> ! SELECT REQUEST FILE --> open "safe.snap" --> LOAD TABLE. Look for differences and confirm changes if needed.
     
  5. Save the new Epics values into the Safe.snap by following step 3 again from here.
     
  6. To confirm that your values were correctly saved into the safe.snap file please use the following terminal commands:
    Check Xarm values:
    cat /opt/rtcds/lho/h1/target/h1calex/h1calexepics/burt/safe.snap | grep FORCE_COEFF && cat /opt/rtcds/lho/h1/target/h1calex/h1calexepics/burt/safe.snap | grep XY_COMPARE_CORR_FACT

    Check Yarm Values:
    cat /opt/rtcds/lho/h1/target/h1caley/h1caleyepics/burt/safe.snap | grep FORCE_COEFF && cat /opt/rtcds/lho/h1/target/h1caley/h1caleyepics/burt/safe.snap | grep XY_COMPARE_CORR_FACT

    If that didn't work..... please request expert assistance for more guidance.
H1 SQZ
naoki.aritomi@LIGO.ORG - posted 16:24, Monday 25 March 2024 (76698)
SQZ BLRMS 6

Sheila, Naoki

We plan to scan the ZM alignment and need the fast SQZ BLRMS for that. We copied the BP filter for BLRMS 5 at 1.7kHz to BLRMS 6 and replaced the 0.1 Hz LP to 1 Hz LP for BLRMS 6.  So the BLRMS 6 is same as BLRMS 5 now, but has 1 Hz LP instead of 0.1 Hz LP. The SDF is attached.

Images attached to this report
H1 General
anthony.sanchez@LIGO.ORG - posted 16:09, Monday 25 March 2024 (76697)
Monday Ops Eve Shift Start

TITLE: 03/25 Eve Shift: 23:00-07:00 UTC (16:00-00:00 PST), all times posted in UTC
STATE of H1: Commissioning
OUTGOING OPERATOR: Ryan S
CURRENT ENVIRONMENT:
    SEI_ENV state: CALM
    Wind: 4mph Gusts, 2mph 5min avg
    Primary useism: 0.03 μm/s
    Secondary useism: 0.25 μm/s
QUICK SUMMARY:
H1 has been locked for 4 hours and 22 minutes, We are currently in commissioning while Robert does injections.
The current plan is to stay in comissioning until 6PM then go into Observing.

LHO General
ryan.short@LIGO.ORG - posted 16:01, Monday 25 March 2024 (76680)
Ops Day Shift Summary

TITLE: 03/25 Day Shift: 15:00-23:00 UTC (08:00-16:00 PST), all times posted in UTC
STATE of H1: Commissioning
INCOMING OPERATOR: Tony
SHIFT SUMMARY: Locked most of the day; several commissioning activities ongoing with observing periods in between.

LOG:

Start Time System Name Location Lazer_Haz Task Time End
15:17 FAC Karen Opt/Vac Lab - Technical cleaning 15:51
16:06 FAC Chris FCES - Safety checks 16:42
16:10 PEM Robert LVEA - Set up for PEM injections 16:31
16:17 FAC Karen MY - Technical cleaning 17:30
16:24 FAC Kim MX - Technical cleaning 17:46
21:07 TCS TJ Opt Lab - Looking for parts 21:56
21:26 PEM Robert LVEA - Set up for PEM injections 22:22
H1 SUS (CDS, ISC)
jeffrey.kissel@LIGO.ORG - posted 15:59, Monday 25 March 2024 - last comment - 14:08, Tuesday 26 March 2024(76696)
Model Prep for HAM Small and Large Triples Watchdog Upgrade Complete
J. Kissel
ECR E1700387
IIET 9392
WP 11743

Tomorrow, we continue on the adventure towards upgrading the suspension watchdog systems that Oli, Dave and I have been chugging along on for the previous two weeks (see, eg, LHO aLOGs 76305, 76269 and 76545).
This week, we're tackling a big chunk -- all of the HAM triple suspensions, both large and smal, i.e. the 7 HSTS and 2 HLTS. 

Note :: these are the final suspensions that are hooked up to their respective ISIs, so this should be the last major upgrade.

As such I've:
    In the SUS model library parts,
    - Converted the BLRMS trigger generating systems to include a trust-worthy RMS calculation, coupled with a down-stream low-pass filter,
    - Removed all evidence of the USER DACKILL watchdog aggregator system
    - While I was there, I removed remaining evidence of the long-defunct / depricated "online detector characterization" ODC system, long since replaced by guardian state information
    On the top level SUS models,
    - Removed all evidence of the USER DACKILL watchdog aggregator system
    - Removed the IPC sender of the USER DACKILL to the respective ISI
    - Verified that the removal of library block output ports didn't botch any of the top level connections, reconnecting and re-organizing as needed
    On the top level of the ISI models,
    - Replaced the IPC receiver of the USER DACKILL watchdog from all respective SUS

which impacts all of the following models:

    Top Level ISI               Top Level Optic     Governing Library Part
    h1isiham2.mdl               h1susmc1.mdl        HSTS_MASTER.mdl
                                h1susmc3.mdl        HSTS_MASTER.mdl
                                h1suspr3.mdl        HLTS_MASTER.mdl
                                h1susprm.mdl        RC_MASTER.mdl

    h1isiham3.mdl               h1susmc2.mdl        MC_MASTER.mdl
                                h1suspr2.mdl        RC_MASTER.mdl

    h1isiham4.mdl               h1sussr2.mdl        RC_MASTER.mdl

    h1isiham5.mdl               h1sussr3.mdl        HLTS_MASTER.mdl
                                h1sussrm.mdl        RC_MASTER.mdl

    (no change to isiham7)      h1susfc1.mdl        HSTS_MASTER.mdl

    (no change to isiham8)      h1susfc2.mdl        HSTS_MASTER.mdl

In addition, some of the lower level SUS library parts were also impacted,
    SIXOSEM_T_STAGE_MASTER.mdl
    FOUROSEM_STAGE_MASTER.mdl
    FOUROSEM_STAGE_MASTER_OPLEV.mdl

All of the above model changes have been committed to the userapps SVN repo in revs 27310, 27311, 27312, and 27313.
    
Comments related to this report
jeffrey.kissel@LIGO.ORG - 14:00, Tuesday 26 March 2024 (76719)
This set of screenshots shows the typical edits to the top level HAM models, before vs. after.

Note, because the "payload" is more that one suspension on the HAMs, I got lazy and started connecting two constants to four places, rather than putting in eight constants. In doing so, I harnessed the trickery of the bus creator / bus selector, and re-arranged the order hidden within. The screenshot highlights this debauchery in purple.
Images attached to this comment
jeffrey.kissel@LIGO.ORG - 14:08, Tuesday 26 March 2024 (76720)
Here are some before vs. after, example top level model changes for the various types of HSTS and HLTS:
PRM (an RC_MASTER) before vs. after

MC2 (an MC_MASTER) before vs. after

PR3 (an HLTS_MASTER) before vs. after

Images attached to this comment
H1 ISC (OpsInfo)
camilla.compton@LIGO.ORG - posted 15:54, Monday 25 March 2024 - last comment - 13:17, Tuesday 26 March 2024(76695)
Beam spot stepper scripts to run tonight in Observing using Camera Servo Offsets

We aimed to do A2L steps over the weekend, 15 minutes/step  76630, 76683, but as Elenna points out with the camera servos running the beam spot stayed static on the mirror while the mirror actuation point changed.

Looking at data from A2L tuning in April 2023 68384 attached plot, A2L steps are ~0.4 for a change of around 2 in the camera offset  (TRAMP 120s). We'll keep around the steps same as the weekend: +/- 1.0 per 15 minutes to up to +/-2.0 in the H1:ASC-CAM_{PIT,YAW}{1,2,3}_OFFSET channels during observing with nominal TRAMPs extended from 10s to 120s. These offsets are already unmonitered in sdf as reset each lock, I unmonitered the TRAMPs.

These offfsets vary up to 3 counts lock to lock, see attached plot. Set based on ADS converging.

Script saved in /ligo/gitcommon/labutils/beam_spot_raster/camera_servo_offset_stepper.py  Scheduled to run if we're in NLN via tmux session on cdsws26 at:

Tony will be here during the first set so can cancel the others if there is any issues.

Images attached to this report
Comments related to this report
jennifer.wright@LIGO.ORG - 13:17, Tuesday 26 March 2024 (76711)

Jennie, Camilla

 

I looked at the CAM3 test from 08:58:40 UTC to 12:46:33 UTC and can see that a high offset (ASC-CAM_{PIT3, YAW3}_OFFSET) in both pitch and yaw corresponds to high power build-ups in the PRC and arms. Yaw seems to have more of an effect than pitch. The range dips when the offset is away from its nominal state. See first image. The offsets don't seem to have much effect on KAPPA C.

 

During the CAM2 test the IFO unlocked and so only the P2L steps seem to have run, its hard to see a trend in the build-ups for this as the IFO was still thermalising - maybe this hsould be run again. See second image.

For the CAM1 test the yaw steps were interrupted by lockloss so we will have to redo these.

The pitch steps for CAM 1 show optimum build-ups/power recycling at Pitch offset = -231.6 counts and worst at -229.6 counts. The range is worst when the build-ups are best and vice versa.

I am not sure why lower circulating power makes the range drop for all these measurements.

Images attached to this comment
H1 SQZ
naoki.aritomi@LIGO.ORG - posted 15:51, Monday 25 March 2024 (76693)
FC detuning improvement

We scanned the FC detuning as shown in the first attachment. The nominal FC detuning is -28. The FC detuning below -31 seems better around 30 Hz. The second attachment shows that the BNS range at -34 FC detuning seems a few Mpc better than nominal so we set the FC detuning at -34 as shown in the third attachment.

Images attached to this report
H1 SQZ (SQZ)
julian.gurs@LIGO.ORG - posted 15:29, Monday 25 March 2024 (76691)
Spare SHG single pass temperature scan

A sinc function / temperature measurement from the single pass (spare) SHG is shown. The basic idea of the experiment was to see if the crystal is intact (it is). For this purpose, the crystal was pumped with 1064 nm and after one pass (single pass) it was checked how much green light was generated. The temperature was adjusted to find the best possible phase matching temperature.

No similarity to Mount Saint Helens, as described in 76239, was observed. Conclusion, the crystal is intact. (What seems strange is the asymmetry in the side maxima.)

Setup:

Images attached to this report
Non-image files attached to this report
H1 CAL
francisco.llamas@LIGO.ORG - posted 15:01, Monday 25 March 2024 (76689)
Progress on pcal migration to python - Multiple KDVM measurements

RickS, DaveB, TonyS, FranciscoL

On Friday, March 22, we measured an SRS SR340 function generator (FG) using three Keithley digital multimeters (KVM) to calculate the latency between each KVM. The FG was configured to make a ramp/sawtooth wave set to 20 Vpp at 0.1 Hz. The KVMs were configured to read 200 samples without delay. Figure "...200samples.pdf" shows the raw data from the KVM. Figure "...samples_zoom.pdf" is zoomed in the first section with a line fitted to the data. The line has a slope of m = 2 V/s.

The differences from the first KVM (id: 8019157) to the second KVM (id: 8018958) is plotted in blue on figure "...samples_diff.pdf" and yields a mean of 40.4 mV with a standard dev. of 0.21 mV. The differences from the first KVM to the third KVM (id: 1148559) is plotted in red on figure "...samples_diff.pdf" and yields a mean of 0.0808 V with a standard dev. of 0.44 mV. Figure "...samples_diffsub.pdf" plots each voltage difference individually. These values yield a latency between KVMs of 20.2 ms and 40.4 ms, respectively. To calculate the overall timing of the loop that stores the data, we measured the difference between a KVM 8019157 with itself (current - previous) and got a mean value of 0.1212 V, as indicated by figure "samples_diff2.pdf". The total latency of three keithleys for this measurement is of 60.6 ms.

The data shows that there is a latency of 20.2 ms between each KVM. It is safe to assume that, to sample 4 keithleys simultaneously, there will be an overall latency of 81 ms (~ 12 Hz). This latency is well within our design limits of measuring at a sample rate of 5 times per second.

Non-image files attached to this report
H1 ISC
sheila.dwyer@LIGO.ORG - posted 14:35, Monday 25 March 2024 (76692)
DARM offset test no impact on sensitiivty above 80 Hz

Jennie W, Sheila

Jennie moved the DARM offset (H1:OMC-READOUT_X0_OFFSET  from 10.9 to 7.74 in slow steps) which changed the DCPD sum from 40mA on the DCPDs to 20mA.  This makes the SRCL feedforward adding noise below 70 Hz, but had no impact on the sensitivity above 80 Hz, as shown in the first attachment. 

The second attachment shows a DARM OLG measurement before and after the change, the gain at 60 Hz was the same within 1%.

Images attached to this report
H1 General
ryan.short@LIGO.ORG - posted 14:27, Monday 25 March 2024 (76690)
OMC and CALEY No Longer Excluded from DIAG_EXC

R. Short, T.J. Shaffer

We discovered this afternoon that starting an injection on the OMC model did NOT cause H1 to drop observing. After looking into the DIAG_EXC Guardian node, which checks for errant excitations and prevents going into observing accordingly, we discovered two models had been added to the exclude_list: omc and caley. These appear to have been added in May of 2023 (pre-O4a) and never committed to svn. TJ and I both recalled these models having ongoing excitations in the leadup to O4a, but neither of us could remember why. Clearly they are not needed anymore, so they have been removed, and the exclude_list is again empty (the one exception remains for the CAL-INJ_CW_EXC excitation).

Errant injections into the omc and caley models will now properly prevent H1 from observing.

H1 CAL (CDS, FRS)
jeffrey.kissel@LIGO.ORG - posted 11:18, Monday 25 March 2024 - last comment - 08:19, Tuesday 26 March 2024(76682)
A few EPICs channels added to top-level CAL-CS Front-end model
J. Kissel, L. Dartez
ECR E2400103
IIET 30760
WP 11786

To better coordinate and confirm the front end portion of the calibration pipeline and the GDS portion running on the DMT machines remain in sync in terms of calibration model installed, which is necessary for good calibration, we are adding two slow 16 Hz EPICS channels to the h1/l1calcs models (so both LLO and LHO) that will be added to the GDS broadcaster list so the GDS calibration pipeline can read them. These are H1/L1:CAL-CALIB_REPORT_ID_INT and H1/L1:CAL-CALIB_REPORT_HASH_INT.

Louis and I created the top-level EPICs records today; see attached screenshot.

The change has been committed to the userapps SVN under:
    /opt/rtcds/userapps/release/cal/h1/models/
        h1calcs.mdl          committed at rev 27307.


It's in no way a complicated add to the model, but I've ran a test compile of the h1calcs.mdl on the build machine anyways just to check. The test compiled succeeded without issue.
Images attached to this report
Comments related to this report
jeffrey.kissel@LIGO.ORG - 08:19, Tuesday 26 March 2024 (76704)CAL, CDS
J. Kissel

This model changes have been installed this morning. As such, I've updated the safe.snap SDF system to initialize the H1:CAL-CALIB_REPORT_ID_INT and H1:CAL-CALIB_REPORT_HASH_INT channels. I've also chosen to monitor them, since we don't expect them to change during observation, and/or regulary, and this information will become critical for calibration librarianship.
Images attached to this comment
Displaying reports 14601-14620 of 89077.Go to page Start 727 728 729 730 731 732 733 734 735 End