Displaying reports 14721-14740 of 89077.Go to page Start 733 734 735 736 737 738 739 740 741 End
Reports until 09:06, Thursday 21 March 2024
H1 ISC
gabriele.vajente@LIGO.ORG - posted 09:06, Thursday 21 March 2024 - last comment - 12:19, Thursday 21 March 2024(76582)
OMC locking RMS and offset tests

[Jennie, Louis, Gabriele]

This morning we carried out some tests to understand if the excess DARM noise could be OMC length noise. We increased the OMC  in-lock residual length RMS (by changing the loop gain and by injecting a 4 Hz line), and changed the OMC lock offset. We expect the coupling from OMC length to DARM to scale linearly with both the RMS and the offset.

More details will follow in comments, but we increased the OMC length RMS by about a factor 10 and saw no visible change in the DARM noise in the bucket. We also added several lock offsets and saw no change in DARM noise in the bucket.

So the DARM excess noise is not OMC length noise.

During the test we injected a 135 Hz OMC length line, and checked that the coupling scales as expecetd with the RMS and the offset.

We lost lock at the end of the ramp when we were changing the OMC length dither frequency from 4100 Hz to 4101 Hz with a 30 second ramp. We saw that the 4 Hz bump in the error signal was moving toward 5 Hz during the ramp: this confirms that the origin of the 4 Hz bump is due to some "beat" between 4100 Hz and 4096 = 16348/4 Hz

Images attached to this report
Comments related to this report
gabriele.vajente@LIGO.ORG - 09:15, Thursday 21 March 2024 (76584)

We measured the DARM / OMC_PZT transfer function at 135 Hz during the offset tests, and found a very linear trend without any significant offset, as expected

Images attached to this comment
gabriele.vajente@LIGO.ORG - 09:25, Thursday 21 March 2024 (76585)

Test times

Reference quiet time 1395060517 1395061305

Gain change test
gain 24 1395062380 1395062849
gain 12 1395063409 1395064053
gain 48 1395064462 1395064825

4 Hz injection
gain 0.0015 1395065763 1395066089
gain 0.0030 1395066112 1395066455
gain 0.0060 1395066476 1395066784
gain 0.0120 1395066802 1395067093

Offset test
 100e-6 1395068536 1395068841
 200e-6 1395068876 1395069277
 300e-6 1395069301 1395069708
 0      1395069732 1395070085
-100e-6 1395070107 1395070514
-200e-6 1395070532 1395070878
-300e-6 1395070904 1395071331

jennifer.wright@LIGO.ORG - 12:19, Thursday 21 March 2024 (76599)

The graphs where we increased the gain of the OMC length loop are shown in the first image.

The graphs where we we dithered athe OMC PZT2 at 4Hz with increasing amplitude (while keeping loop gain constant at 24) are shown in the second image

The graphs where we offset the OMC loop error point - ie. changed the error point on the fringe we lock to is shown in the third image, while keeping the loop gain constant.

The top trace is DARM-DELTAL_EXTERNAL_DQ calibrated into m/root Hz using the calibration on the 15th March.

The bottom is the error point of the OMC length loop taken at OMC-LSC_I_OUT_DQ.

Fourth graph is because I had to remeasure the 100e-6 offset again starting at 1395068244 GPS  as there was a glitch somewhere in the 1395068536 GPS measurement.

All measurements used 289 averages, BW 0.5 Hz, 50 % overlap and so each measurement used 290s in total.

Images attached to this comment
H1 General
oli.patane@LIGO.ORG - posted 08:00, Thursday 21 March 2024 (76580)
Ops Day Shift Start

TITLE: 03/21 Day Shift: 15:00-23:00 UTC (08:00-16:00 PST), all times posted in UTC
STATE of H1: Commissioning
OUTGOING OPERATOR: None
CURRENT ENVIRONMENT:
    SEI_ENV state: CALM
    Wind: 11mph Gusts, 8mph 5min avg
    Primary useism: 0.02 μm/s
    Secondary useism: 0.21 μm/s
QUICK SUMMARY:

We've been locked for 9.5 hours! More commissioning!

LHO General
corey.gray@LIGO.ORG - posted 00:40, Thursday 21 March 2024 (76560)
Wed EVE Ops Summary

TITLE: 03/20 Eve Shift: 23:00-07:00 UTC (16:00-00:00 PST), all times posted in UTC

STATE of H1: Commissioning
INCOMING OPERATOR: None
SHIFT SUMMARY:

A return to Observing for H1 (first time since mid-Jan, and a return to Triple Coincidence with Virgo + both LIGO detectors for the first time since O3!)---this occured after about 90min of Commissioning work.  It was a little bit of a rocky start with a wind storm with sustained winds in the 20mph range for almost half the shift (and gusts above 40mph).  This made for several hours of down time (forgot to mark as "WIND" with OBSERVATORY MODE unfortunately).  Eventually able to get back to Observing toward the end of the shift.
LOG:

Images attached to this report
H1 SUS
corey.gray@LIGO.ORG - posted 23:01, Wednesday 20 March 2024 (76579)
SUSPRM SDFs ACCEPTED

After our windstorm, finally ready to get back to OBSERVING, but we had SDFs for PR3 (I could have sworn we had SDFs for PR3 at the beginning of the shift when we were racing to address the piles of SDF Diffs we had so we could get to Observing.).  At any rate, the (3) channels are for Enabling the Input for (3) PR3 channels (see that attached photo of the SUSPR3 Diffs which were ACCEPTED).

Images attached to this report
LHO General
corey.gray@LIGO.ORG - posted 19:58, Wednesday 20 March 2024 (76578)
Mid-shift Status

Winds really picked up a bit shortly after we went to Observing.  Have run an alignment, but the last 90mins have seen little action beyond DRMI....made it to OFFLOAD DRMI once.  Will hold for an hour at LOCKING ARMS GREEN for an hour (and while I make lunch).

Images attached to this report
H1 ISC
gabriele.vajente@LIGO.ORG - posted 19:41, Wednesday 20 March 2024 (76551)
OMC length noise guesstimation

Let's assume the additional flat noise in the ~100 Hz region that might be limiting now (w.r.t. to O4a) is due to OMC length noise. Either the OMC lenght noise is larger than before, and coupling through the residual OMC length RMS noise, or the OMC lock has an offset.

Let's assume that the OMC was locked at the top of the resonance (no offset, to be confirmed with the new demodulation phase).

According to 76137, the two PZT responses are PZT1 = 11.3 nm/V, and PZT2 = 12.7 nm/V.

Following Sheila's note in 30510, the normalized OMC transmission (RIN) is given by [after correcting for a mistake in the coefficient multipling F]

RIN = 1 / (1 + (2 F (x0 + dx)/ lambda)^2 )

where F = 400 is the OMC finesse (76386), x0 is a static lock offset (or equivalent RMS fluctuation) and dx is OMC lenght noise (form example due to dither).

The amplitude of the dither line is 0.23 V peak, corresponding to a dither amplitude (peak) of A = 2.6e-9 m, using the PZT1 calibration above.

The locking error signal is obtained using a length modulation dx = A sin(wt) that gives a RIN = (2F/lambda)^2 A sin(wt) x0, where x0 is the offsetf from resonance of the OMC length. Once demodulated, this gives

OMC-LSC_I = (2F/lambda)^2 A/2 x0 = 7.3e8 error_signal_demodulated_RIN / m (note that 30510 seems to be wrong and missing some factors, thank you Elenna for checking)

This allows me to calibrate the OMC-LSC input signal. The RMS with the OMC locked is 4.7e-5 RIN, corresponding to 6.4e-14 m RMS of residual OMC fluctuation around the lock point.

The flat noise in DARM is about 7e-21 m/rHz. Using the optical gain from the calibration measurement (3.4e6 LSC-DARM_IN cts/m) and the ratio LSC-DARM_IN / OMC_DCPD_NORM = 1.6e-5, I find an optical gain of 2.1e11 RIN/m for OMC-DCPD_NORM

Therefore the noise in DARM corresponds to a OMC-DCPD RIN of 1.5e-9 RIN/rHz

Noise coupling due to the residual OMC length RMS goes like (2F/lambda)^2 x_RMS dx_noise, where x_RMS is now the residual RMS motion computed above. Using this conversion, I found that the excess noise in DARM would correspond to a OMC length noise of 4e-14 m/rHz at 100 Hz. This still seems higher than the expected noise that should be in the 3e-16 m/rHz range (see for example section 8 of T1000276)

Tests to do:

  1. check if the new demodulation phase improves anything in DARM
  2. scan the OMC lock offset around 0, looking at DARM noise and at the optical gain (for example amplitude of the 410.3 Hz calibration line)
  3. change the locking gain to reduce / increase RMS and check DARM
Non-image files attached to this report
H1 PEM
evan.hall@LIGO.ORG - posted 19:05, Wednesday 20 March 2024 - last comment - 17:11, Thursday 28 March 2024(76575)
End station vibration over past 150 days -- EY BSC10 moves more than before

In addition to the BSC10 accelerometer, the amount of floor motion also increases over the past 6 weeks, though not in a sudden fashion.

This does not correspond to the time of the most recent fan swap, judging by fan accelerometers.

Images attached to this report
Comments related to this report
marc.pirello@LIGO.ORG - 09:36, Thursday 21 March 2024 (76586)

New EX and EY Accelerometer Power Conditioners were installed 30 January 2024.  This is roughly the same time as some of these jumps in the trend.  The EY BSC 10 accelerometer cable had a questionable connector but still functioned so I believe we left it, it may need to be replaced.

https://alog.ligo-wa.caltech.edu/aLOG/index.php?callRep=75592

marc.pirello@LIGO.ORG - 13:23, Thursday 21 March 2024 (76602)

We replaced the loose connector but did not see any effect on the signal.  While down there we looked at the output and found that channel 5 output was very noisy, and looking back at the notes in my prior ALOG, channel 5 = PEM EY BSC ACC X and back then it did not register as an accelerometer.  I assume this accelerometer is not functional or the cabling is not correct.  We plan to go back on Tuesday and track down the issue with this accelerometer and possibly repair the channel in the power conditioner chassis.

Other notes

The INPUT to CH3 on the power conditioner is "TBL-Y" accelerometer cable.  When unplugged this affected "BSC-Y" signal plot.
The INPUT to CH4 on the power conditioner is "BSC-Z" accelerometer cable.  When unplugged this affected "BSC-Z" signal plot. (this one was correct)

Looking back at my analysis of the drawings in the linked ALOG, the above note matches the drawings in the DCC D1300773.  I propose we assume the cables are swapped incorrectly but labeled correctly, and we rearrange the cables to match the drawing.

Marc, Fil, Gerardo, Janos

 

evan.hall@LIGO.ORG - 17:11, Thursday 28 March 2024 (76782)

Refer to LHO:76728.

H1 SQZ (SQZ)
nutsinee.kijbunchoo@LIGO.ORG - posted 18:12, Wednesday 20 March 2024 - last comment - 11:35, Thursday 28 March 2024(76574)
High CLF in the IFO

Naoki, Daniel, Nutsinee

Today we increased RF6  from -22dBm to -13 dBm and 8 dBm. We saw excess noise at 8 dBm above 300Hz but no excess noise at -13dBm. REF 12 is the squeezing at -22dB before we started the test. Using the time from alog76553. REF9 and REF10 both show squeezing at -13dBm RF6 at different squeeze angle where one has a better sensitivity at low frequency bucket. REF13 shows squeezing at 8dBm RF6. The excess noise above 300Hz cannot be improved with squeeze angle. Investigation is required.

We turned off ADF sqz angle servo during the test. We readjusted the ADF squeeze angle demod phase and accepted the new value in the SDF.

We are parking RF6 at -12dBm. Since Daniel didn't like the unlucky number 13.

 

Loop Was (-22dBm RF6) Now (-12 dBm RF6)
CLF gain 10 0
LO gain -7 -12
FC LSC gain -2.6 -0.86
FC ASC gain 0.1 0.03
Images attached to this report
Comments related to this report
naoki.aritomi@LIGO.ORG - 18:32, Wednesday 20 March 2024 (76576)

The -22dBm, -12dBm, 8dBm RF6 correspond to 9 uW, 28 uW, 420 uW CLF REFL power.

camilla.compton@LIGO.ORG - 11:26, Thursday 21 March 2024 (76595)

We rechecked the FDS -22dBm time as the time in the above plot wasn't sqz opitmized to the bucket. Can see in attached plot, CLF at -22dBm and -13dBm have the same SQZ in the bucket, as expected.

Images attached to this comment
nutsinee.kijbunchoo@LIGO.ORG - 12:27, Monday 25 March 2024 (76686)

Looking back at the past data it seems we may not have adjusted the CLF ISS gain properly during the test causing our sqz level to be stuck at 3dB at kHz region. CLF_REFL_DC was oscillating when RF6 was at -13 dBm and at 8 dBm. This looks like an easy fix and we should try again at some point.

Images attached to this comment
nutsinee.kijbunchoo@LIGO.ORG - 10:11, Wednesday 27 March 2024 (76743)

Daniel Nutsinee

Reducing the gain didn't seem to fix the oscillation. We cranked up the CLF power so the RF6 read 6dBm and went out to look at the signal on the scope. We saw 60kHz beat note on the OPO refl and a crooked 105kHz sinewave on the CLF refl. We don't know where the 60kHz beat on the OPO refl came from. We couldn't make any improvement by changing the CLF ISS gain.

After some investigation we realized the oscillation disappeared when we unplugged the RLF. The oscillation came back when the RLF was plugged back in. The oscillation associated with the RLF seemed obvious only when we operated at high power. Next time we try high CLF power again we should attenuate the RLF RF output to the AOM.

 

The funny thing was PMC refl saw this oscillation as well. We hope this was just an electronics cross talk.

Images attached to this comment
daniel.sigg@LIGO.ORG - 11:35, Thursday 28 March 2024 (76771)

For even higher CLF power with +6dBm at the RF6 demod, we set the CLF servo IN2 gain to-18dB (from 0dB), the CLF ISS gain to 0dB (from 17dB), and the ISS input set point to 2.037 (from 0.347).

H1 ISC
jenne.driggers@LIGO.ORG - posted 17:13, Wednesday 20 March 2024 (76572)
SDFs for green initial alignment setpoints

SDFs from green initial alignment setpoints

Images attached to this report
H1 General (CAL, ISC, SUS)
corey.gray@LIGO.ORG - posted 17:12, Wednesday 20 March 2024 (76562)
SDF ACCEPT/REVERT Notes

Jenne was pecking away at SDFs (separate alogs), Jennie/Evan did OMC (I took screenshot below), Louis helped with PCal.....Squeezer work is currently active, so will wait for that team to ACCEPT Squeezer!

Pecking away at some SDFs in preparation for OBSERVING tonight:

Easy Ones To ACCEPT

More Involved to ACCEPT:

Images attached to this report
H1 SQZ
daniel.sigg@LIGO.ORG - posted 17:05, Wednesday 20 March 2024 - last comment - 16:55, Tuesday 26 March 2024(76568)
ASC SQZ FC SDF

These changes were accpted, but need to be set again after aligning the FC IR transmission.

Images attached to this report
Comments related to this report
nutsinee.kijbunchoo@LIGO.ORG - 16:55, Tuesday 26 March 2024 (76730)

Naoki Nutsinee

We realigned IR trans diode. Accepted a new trigger values in the SDF.

Images attached to this comment
H1 ISC
jenne.driggers@LIGO.ORG - posted 16:47, Wednesday 20 March 2024 - last comment - 17:11, Wednesday 20 March 2024(76563)
OBSERVE.snap SDFs for Dark Offsets

I've accepted dark offsets for the LSC and ASC PDs in SDF for the Observe.snap files. 

Images attached to this report
Comments related to this report
jenne.driggers@LIGO.ORG - 17:07, Wednesday 20 March 2024 (76569)

Dark offsets for ISCEX and ISCEY

Images attached to this comment
jenne.driggers@LIGO.ORG - 17:11, Wednesday 20 March 2024 (76571)

ALS X and ALS Y dark offset SDFs.

Images attached to this comment
H1 SQZ
camilla.compton@LIGO.ORG - posted 15:53, Wednesday 20 March 2024 - last comment - 08:23, Thursday 21 March 2024(76556)
SQZ_ANG_ADJUST servo turned back on

Naoki, Nutsinee, Camilla

We turned the SQZ_ANG_ADJUST servo back to it's O3a nominal ADJUST_SQZ_ANG_ADF.  Changed sqzparams.use_sqz_angle_adjust to True and reloaded SQZ_MANAGER and SQZ_ANG_ADJUST.

Set H1:SQZ-ADF_OMC_TRANS_PHASE as 133deg, new scan (as in 76434) running now to check what angle is best for total squeezing.

Comments related to this report
camilla.compton@LIGO.ORG - 16:16, Wednesday 20 March 2024 (76561)

Accepted at H1:SQZ-ADF_OMC_TRANS_PHASE = 120. This seems to give us the best range but not high frequency SQZ. Plot attached.

Images attached to this comment
nutsinee.kijbunchoo@LIGO.ORG - 17:46, Wednesday 20 March 2024 (76573)

We optimized the sqz angle after high CLF test and readjusted the AADF demod phase.

Images attached to this comment
camilla.compton@LIGO.ORG - 08:23, Thursday 21 March 2024 (76581)

We should check the ADF offset with a more themalized IFO as the SQZ angle servo seems to have pulled even the yellow BLRM to a worse location, see attached.

Images attached to this comment
H1 SEI (ISC)
jim.warner@LIGO.ORG - posted 11:16, Wednesday 20 March 2024 - last comment - 09:06, Thursday 21 March 2024(76544)
NLN locklosses sending big kicks to ETMX HEPI

The commissioners are aware of this now and some people are looking into it, but it seems that the new DARM offloading scheme has been sending big kicks (a few 10s to 200 microns) to the ETMX HEPI at almost every lockloss from NLN. This doesn't seem to be happening with ETMY. On attached trends, top blue trace is the ISC tidal signal sent to ETMX HEPI, yellow is the ISI watchdog state, bottom is the ISC LOCK state number. The ISI doesn't trip every time, but it's happend 5 times just over the last week. This isn't normal behavior, but it seems like we've just been ignoring this for a while. I recall having this happen a bit before the end of O4a, and we added a filter to the input to the HEPI model, but that just seems to slow the kick a bit. 

Images attached to this report
Comments related to this report
evan.hall@LIGO.ORG - 12:35, Wednesday 20 March 2024 (76546)ISC

Louis and I modified the aL1L3 filter (FM6) in ETMX_L1_LOCK_L by replacing the single pole at 50 Hz with a complex pair at 30 Hz, so that this offloading filter rolls off like 1/f above 30 Hz. Since the output of L1_LOCK_L is offloaded to HEPI, we suspect that this is what was causing the kick at EX. No DARM control is directly applied to EY, so that would explain why EY does not trip. The most recent lockloss did not trip anything.

Images attached to this comment
jim.warner@LIGO.ORG - 13:04, Wednesday 20 March 2024 (76549)

It didn't trip the ISI, but we still are spiked up to about a third of the actuators drive range on the last lockloss. I'm less worried about tripping the ISI than I am about damaging something on the suspension or HEPI. attached trend shows the ISC signal to ETMX HEPI and the drives on the horizontal actuators at the last lockloss. 

Images attached to this comment
camilla.compton@LIGO.ORG - 14:04, Wednesday 20 March 2024 (76552)

Evan added a 0.1Hz low pass filter into FM3 of H1:LSC-X_ERR_TIDAL_ERR, and for symmetry into H1:LSC-Y_ERR_TIDAL_ERR. Turned on filters and sdfs.  We expect this to stop the kicks and not effect the slower tidal offloading: titdal to UIM is ~0.03Hz, to HEPI would be even slower  68749.

camilla.compton@LIGO.ORG - 09:06, Thursday 21 March 2024 (76583)

Since the 0.1Hz LP has been added, the two locklosses have not kicked the HEPI. See attached zoomed out and zoomed in plots. 

Images attached to this comment