oli.patane@LIGO.ORG - posted 00:06, Tuesday 26 December 2023 (75040)
Ops EVE Shift End

TITLE: 12/26 Eve Shift: 00:00-08:00 UTC (16:00-00:00 PST), all times posted in UTC
STATE of H1: Observing at 157Mpc
INCOMING OPERATOR: Ryan S
SHIFT SUMMARY: We are Observing and have now been Locked for 14.5 hours.

Very quiet shift, with the only thing happening was that ITMY Mode 20 (aka narrower ITMY Mode 6) had started ringing back up slowly. It seems like during the first two hours that we had been locked, the ITMY 5 gain setting had helped ITMY20 settle down to around 4.06, and then over the next four hours ITMY20 continued decreasing at a lower rate of change from 4.06 -> 3.99. However, after this, ITMY20 started slowly ringing back up, and 4.5hours later was back to being above 4.06. During all of this, ITMY 5, 6, and 10 were still decreasing. I decided to try turning the ITMY5 gain to 0 to see what that would do, but that caused mode 5 to immediately start rising at a much faster rate than mode 20 had been before, so I turned the gain back on and they've all been decreasing again the past 3.5 hours.

LOG:

00:00 Detector Observing and Locked for 6.5hours

H1 General
oli.patane@LIGO.ORG - posted 20:10, Monday 25 December 2023 (75039)
Ops EVE Midshift Status

Observing at 155Mpc and have been Locked for 10.5 hours. Nothing to report.

H1 General
oli.patane@LIGO.ORG - posted 16:09, Monday 25 December 2023 (75038)
Ops EVE Shift Start

TITLE: 12/26 Eve Shift: 00:00-08:00 UTC (16:00-00:00 PST), all times posted in UTC
STATE of H1: Observing at 154Mpc
OUTGOING OPERATOR: Ryan C
CURRENT ENVIRONMENT:
    SEI_ENV state: CALM
    Wind: 5mph Gusts, 3mph 5min avg
    Primary useism: 0.05 μm/s
    Secondary useism: 0.85 μm/s
QUICK SUMMARY:

We are Observing and detector has been Locked for 6.5 hours.

H1 General
ryan.crouch@LIGO.ORG - posted 16:01, Monday 25 December 2023 (75035)
OPS Monday day shift summary

TITLE: 12/25 Day Shift: 16:00-00:00 UTC (08:00-16:00 PST), all times posted in UTC
STATE of H1: Observing at 150Mpc
INCOMING OPERATOR: Oli
SHIFT SUMMARY: We stayed locked for most of the shift, 1 lockloss. Locked and observing for ~6:30 as of 00:00UTC

16:41UTC Lockloss after only 36 minutes, using 'guardctrl log -a "12/25/2023 16:38 UTC" -b "12/25/2023 16:42 UTC" DIAG_SDF' it seems the SQZer lost lock first. Automated relock

Xarm has been locking at higher power than usual, ~1.2

I also set ITMX mode 12s gain and max gain to 0 in lscparams as its been ringing up the past few locks and reloaded ISC_LOCK and VIOLIN_DAMPING.

I did a quick walkthrough of the OSB, Staging building, LSB, and LExC and saw nothing of note.

LHO VE
david.barker@LIGO.ORG - posted 10:58, Monday 25 December 2023 (75037)
Mon CP1 Fill, manual cancel needed

Mon Dec 25 10:06:01 2023 ALERT: Fill done (errors) in 5min 58sec

TCs started high (31C/34C) so I increased the trip temps before today's fill from -70C to -60C. Despite this, Gerardo had to cancel the fill after it started overflowing, TCmins were -51.5C/-46.5C.

Images attached to this report
H1 General (Lockloss)
ryan.crouch@LIGO.ORG - posted 08:42, Monday 25 December 2023 - last comment - 09:35, Monday 25 December 2023(75034)
Lockloss at 16:41

https://ldas-jobs.ligo-wa.caltech.edu/~lockloss/index.cgi?event=1387557678, only 36 minutes into the lock

Comments related to this report
ryan.crouch@LIGO.ORG - 09:35, Monday 25 December 2023 (75036)

Back into observing at 17:33

H1 General
ryan.crouch@LIGO.ORG - posted 08:02, Monday 25 December 2023 - last comment - 08:10, Monday 25 December 2023(75032)
OPS Monday day shift start

TITLE: 12/25 Day Shift: 16:00-00:00 UTC (08:00-16:00 PST), all times posted in UTC
STATE of H1: Lock Acquisition
OUTGOING OPERATOR: TJ
CURRENT ENVIRONMENT:
    SEI_ENV state: CALM
    Wind: 2mph Gusts, 1mph 5min avg
    Primary useism: 0.07 μm/s
    Secondary useism: 0.86 μm/s
QUICK SUMMARY:

 

Comments related to this report
ryan.crouch@LIGO.ORG - 08:10, Monday 25 December 2023 (75033)

Back into NLN at 16:04 and Observing at 16:10UTC

H1 General
oli.patane@LIGO.ORG - posted 00:14, Monday 25 December 2023 (75030)
Ops Eve Shift End

TITLE: 12/25 Eve Shift: 00:00-08:00 UTC (16:00-00:00 PST), all times posted in UTC
STATE of H1: Observing at 146Mpc
INCOMING OPERATOR: TJ
SHIFT SUMMARY: We are Observing and have been Locked for 10 minutes. The lockloss recovery required an Initial Alignment, and while trying to acquire MICH, it was having trouble registering that it was over the threshold because one of the beams was slightly higher than the other, so I needed to adjust the beamsplitter. After that the rest of initial alignment and locking went smoothly.
LOG:

00:00 Detector Observing and Locked for 3.25 hours

05:30 Lockloss (75026)
-- Relocking --
06:03 I took the detector to DOWN because we kept running through CHECK_MICH_FRINGES and needed to run an Initial Alignment
06:08 Started Initial Alignment
    - Detector was having trouble with aligning MICH due to the beams being slightly offset in pitch and thus being too low for the trigger - I had to adjust the BS in pitch quite a bit for it to finally catch
07:06 Initial Alignment complete

07:49 Reached NOMINAL_LOW_NOISE
--Relocking End --

07:52 Into Observing

H1 DetChar (DetChar)
miftahul.maarif@LIGO.ORG - posted 23:09, Sunday 24 December 2023 (75027)
Data Quality Shift Report 2023-12-18 to 2023-12-24

Full DQ shift report is here.

H1 General (Lockloss)
oli.patane@LIGO.ORG - posted 21:33, Sunday 24 December 2023 - last comment - 00:18, Monday 25 December 2023(75026)
Lockloss

Lockloss @ 12/25 05:30UTC

Comments related to this report
oli.patane@LIGO.ORG - 00:00, Monday 25 December 2023 (75028)

07:52UTC Back Observing

oli.patane@LIGO.ORG - 00:18, Monday 25 December 2023 (75031)

This lockloss, the 12/24 08:34UTC lockloss, and the 12/22 10:59UTC lockloss all have (below threshold) glitches in ETMX right before the locklosses.

H1 General
oli.patane@LIGO.ORG - posted 19:52, Sunday 24 December 2023 (75025)
Ops EVE Midshift Status

Detector is Observing at 155Mpc and has been Locked for 7 hours now. Nothing to report.

H1 General
oli.patane@LIGO.ORG - posted 16:04, Sunday 24 December 2023 (75024)
Ops EVE Shift Start

TITLE: 12/25 Eve Shift: 00:00-08:00 UTC (16:00-00:00 PST), all times posted in UTC
STATE of H1: Observing at 153Mpc
OUTGOING OPERATOR: Ryan C
CURRENT ENVIRONMENT:
    SEI_ENV state: CALM
    Wind: 6mph Gusts, 3mph 5min avg
    Primary useism: 0.08 μm/s
    Secondary useism: 0.61 μm/s
QUICK SUMMARY:

Detector Observing and Locked for 3 hours. Microseism is high but everything is looking good currently.

H1 General (TCS)
ryan.crouch@LIGO.ORG - posted 15:54, Sunday 24 December 2023 (75016)
OPS Sunday day shift summary

The IFO was relocking from a recent LL when I arrived (15:15UTC) which looked to have been caused by some sudden local ground motion. Anthropogentic tag with over the threshold z-direction ground motion.

At 17:43 I went out to the VPW to power cycle thermostats again

While relocking I had lots of higher state locklosses, Lockloss at LOWNOISE_COIL_DRIVERS, TRANSITION_FROM_ETMX, MAX_POWER. After the MAX_POWER lockloss the violins looked very rung up on DARM. HWS codes stopped for ITMY reports DIAG_MAIN tagging TCS

20:47 back into Observing after slowly stepping through the higher states starting with MAX_POWER, out of Observing at 22:24 for Naoki to adjust the SQZer, back into Observing at 22:36UTC

ITMX mode12 was ringing up under nominal settings again so I used FM1+FM6+FM10 G=+1 to damp it

H1 SQZ
naoki.aritomi@LIGO.ORG - posted 14:55, Sunday 24 December 2023 (75023)
ADF demod phase change

In the observing starting from Dec 24 20:47:52 UTC, the ADF servo seems to bring the squeezing to the wrong place, which caused huge BNS range drop. I asked the operator to go to commissioning and turned off ADF servo. I found that when squeezing angle is optimal, the error signal of ADF servo is not around 0 so I changed the ADF demod phase from 91 to 97 to make the error signal close to 0. Then I turned on ADF servo, accepted one SDF as shown in the attachment, and asked the operator to go to observing.

Images attached to this report
H1 General (CDS, TCS)
ryan.crouch@LIGO.ORG - posted 11:50, Sunday 24 December 2023 - last comment - 12:48, Sunday 24 December 2023(75020)
OPS Sunday day shift update

Relocking has been a struggle, high state locklosses, LOW_NOISE_COIL_DRIVERS, TRANSITION_FROM_ETMX, MAX_POWER.... Currently at 25W

DIAG_MAIN reports that the HWS ITMY code has stopped, violin modes were rung up during a MAX_POWER lockloss and have been giving me trouble since. I've also been getting lots of IY saturations during higher states (MOVE_SPOTS, DARM_TO_DC_READOUT, ...)

Comments related to this report
ryan.crouch@LIGO.ORG - 12:15, Sunday 24 December 2023 (75021)

I made it to OMC_WHITENING, just waiting on the vioins to damp before returning to Observing

ryan.crouch@LIGO.ORG - 12:48, Sunday 24 December 2023 (75022)

20:47 back into Observing