Displaying reports 15741-15760 of 86534.Go to page Start 784 785 786 787 788 789 790 791 792 End
Reports until 12:20, Sunday 17 September 2023
H1 General
oli.patane@LIGO.ORG - posted 12:20, Sunday 17 September 2023 (72925)
Ops DAY Midshift Update

Observing at 144Mpc and Locked for 6hrs 25mins.

Quiet shift so far, although wind seems to have picked up a bit but not too bad.

LHO VE
david.barker@LIGO.ORG - posted 10:10, Sunday 17 September 2023 (72924)
Sun CP1 Fill

Sun Sep 17 10:08:15 2023 INFO: Fill completed in 8min 11secs

Images attached to this report
H1 CDS
david.barker@LIGO.ORG - posted 10:02, Sunday 17 September 2023 - last comment - 09:09, Monday 18 September 2023(72923)
nuc26 (video camera fom) may need a reboot

The web images from nuc26 have been frozen from 09:56 UTC (02:56 PDT) and I cannot ping this machine. If the local camera images in the control room are not updating this computer will need to be rebooted, otherwise it can wait until tomorrow.

Comments related to this report
oli.patane@LIGO.ORG - 12:33, Sunday 17 September 2023 (72926)

The nuc26 cameras in the control room were also frozen and showing that they had frozen at 09/17 06:12UTC. I also could not get into the computer remotely but I restarted the nuc and the cameras are back up and live.

david.barker@LIGO.ORG - 09:09, Monday 18 September 2023 (72934)

I have opened a FRS ticket FRS29119 and closed it as "resolved by rebooting" in case this happens again.

Aplogies, my times were incorrect. The image froze up late Sat night, 16sep 23:12 PDT (17sep 06:12 UTC).

H1 General
oli.patane@LIGO.ORG - posted 08:08, Sunday 17 September 2023 (72922)
Ops DAY Shift Start

TITLE: 09/17 Day Shift: 15:00-23:00 UTC (08:00-16:00 PST), all times posted in UTC
STATE of H1: Observing at 147Mpc
OUTGOING OPERATOR: Tony
CURRENT ENVIRONMENT:
    SEI_ENV state: CALM
    Wind: 4mph Gusts, 2mph 5min avg
    Primary useism: 0.02 μm/s
    Secondary useism: 0.28 μm/s
QUICK SUMMARY:

We are currently Observing and have been Locked for 2 hours. It looks like there were two earthquakes that were in the yellow earthquake zone during the OWL shift, causing us to lose lock twice EDIT: the two earthquakes are in USGS as just one earthquake, which makes sense since they hit us at the same time, and were only the cause of one of our locklosses. Everything will hopefully be calm now!

Images attached to this report
H1 General
anthony.sanchez@LIGO.ORG - posted 06:44, Sunday 17 September 2023 (72921)
SDF Diffs

SDF diffs Changes were made today. I'm not sure if they were intentional or not.
But since we are in NOMINAL_LOW_NOISE I'm gonna accept them.

 

 

#edit: at 2AM when I first posted this ALOG the picture of the SDF Diffs were wrong.  I have since fixed that.
same issue with ALS-Y_REFL_SERVOIN1GAIN and ALS-Y_REFL_SERVO_COMBOOST, I just accepted the changes.

 

Images attached to this report
LHO General
corey.gray@LIGO.ORG - posted 00:03, Sunday 17 September 2023 (72915)
Sat EVE Ops Summary

TITLE: 09/16 Eve Shift: 23:00-07:00 UTC (16:00-00:00 PST), all times posted in UTC
STATE of H1: Observing at 144Mpc
INCOMING OPERATOR: Tony
LOG:

LHO General
corey.gray@LIGO.ORG - posted 20:04, Saturday 16 September 2023 (72920)
EVE Mid-Shift Status

H1 recently had a lock end after just over 8hrs.  Currently waiting for H1 to get back to NLN.  

Environmentally all is well.

H1 General
oli.patane@LIGO.ORG - posted 16:58, Saturday 16 September 2023 (72918)
Ops DAY Shift End

TITLE: 09/16 Day Shift: 15:00-23:00 UTC (08:00-16:00 PST), all times posted in UTC
STATE of H1: Observing at 147Mpc
INCOMING OPERATOR: Corey
SHIFT SUMMARY: Relocking after the lockloss (72911) was a bit strange but seemed like a one-off. Rest of the day was quiet.

15:00UTC In Observing, have been Locked for 18hours

16:38 Lockloss (72911)

16:51 LOCKLOSS_PRMI during third time going through ACQUIRE_PRMI, took itself to DOWN and restarted
17:02 I took it into INITIAL_ALIGNMENT
17:32 INITIAL_ALIGNMENT completed, heading to NOMINAL_LOW_NOISE

17:42 Lockloss at OFFLOAD_DRMI_ASC

18:24 Reached NOMINAL_LOW_NOISE
18:41 Into Observing

LOG:                                                                                                            

Start Time System Name Location Lazer_Haz Task Time End
20:42   Austin+1 LExC, OSB, Overpass n tour 22:04
H1 PEM (FMP, PEM)
corey.gray@LIGO.ORG - posted 16:21, Saturday 16 September 2023 (72917)
HVAC Fan Vibrometer FAMIS Check

All looks nominal for the site HVAC fans (did catch a transition between fans at MY for this one).  Closing FAMIS 26251.

Images attached to this report
LHO General
corey.gray@LIGO.ORG - posted 16:10, Saturday 16 September 2023 (72914)
Sat EVE Ops Transition

TITLE: 09/16 Eve Shift: 23:00-07:00 UTC (16:00-00:00 PST), all times posted in UTC
STATE of H1: Observing at 147Mpc
OUTGOING OPERATOR: Oli
CURRENT ENVIRONMENT:
    SEI_ENV state: CALM
    Wind: 8mph Gusts, 6mph 5min avg
    Primary useism: 0.02 μm/s
    Secondary useism: 0.24 μm/s
QUICK SUMMARY:

H1's been locked just under 5hrs & all looks nominally from here (slight continued drift up in microseism from yesterday).

LHO VE
david.barker@LIGO.ORG - posted 10:13, Saturday 16 September 2023 (72912)
Sat CP1 Fill

Sat Sep 16 10:10:29 2023 INFO: Fill completed in 10min 25secs

Images attached to this report
H1 General (Lockloss)
oli.patane@LIGO.ORG - posted 09:40, Saturday 16 September 2023 - last comment - 17:01, Saturday 16 September 2023(72911)
Lockloss

Lockloss @ 09/16 16:38UTC. EX saturation right before/as the lockloss occurred.

Comments related to this report
oli.patane@LIGO.ORG - 11:41, Saturday 16 September 2023 (72913)

18:41 Observing

oli.patane@LIGO.ORG - 16:55, Saturday 16 September 2023 (72916)

I was able to confirm that LSC-DARM_IN1 does see the lockloss before ASC-AS_A_DC_NSUM_OUT does (attachment1), which had been brought up by TJ (72890), but I want to clarify that this isn't a recent occurance - these locklosses from July 27th(attachment2) and August 10th(attachment3) also show the lockloss in DARM_IN1 a few milliseconds before the light falls off the AS_A photodiode.

In the case of this lockloss, I could not find an obvious cause, but since there was an EX callout right before the lockloss I looked into the ETMX suspension channels that we had looked into a bit yesterday (72896).

The lockloss was seen in DARM and the DCPDs before being seen in ETMX_L3_MASTER_OUT_{UL,UR,LL,LR}_DQ channels (attachment4), followed by the AS_A channel later. However, SUS-ETMX_L3_MASTER_OUT... goes through a few filters/functions before arriving at this reading and so might have a higher latency than the DARM and DCPD channels.

The EX glitch occurred ~700ms before DARM saw the lockloss, and similarly, it was seen in DARM and the DCPDs before the ETMX L3 channels (attachment5). Not sure if this glitch could cause a lockloss (at least not on its own), since we have had glitches this big (and much bigger) in ETMX that were also seen in DARM but did not cause a lockloss, see attachment6 for an example from almost a day earlier.

Thinking about what Camilla said in (72896) "ETMX moving would cause a DARM glitch (so the DARM BLRMs to increase) or vice versa, DARM changing would cause ETMX to try to follow", in this case depending on the latency either could still be true but I don't see why we would lose lock from a (relatively) mid-size saturation but hold on during a larger one unless there was some other factor (which I guess there probably usually is).

Images attached to this comment
oli.patane@LIGO.ORG - 17:01, Saturday 16 September 2023 (72919)

Relocking after this lockloss:

Lost lock after going through ACQUIRE_PRMI three times, so I decided to run an initial alignment. Initial alignment completed fine and we started locking and moving through states quickly, but then we lost lock at OFFLOAD_DRMI_ASC. I let it try locking again and everything was fine, so seems like that OFFLOAD_DRMI_ASC lockloss was just a one-off strange lockloss.

H1 PSL
oli.patane@LIGO.ORG - posted 08:26, Saturday 16 September 2023 (72910)
PSL Weekly FAMIS

Closes FAMIS#26209, last completed Sept 8th


Laser Status:
    NPRO output power is 1.833W (nominal ~2W)
    AMP1 output power is 67.19W (nominal ~70W)
    AMP2 output power is 134.8W (nominal 135-140W)
    NPRO watchdog is GREEN
    AMP1 watchdog is GREEN
    AMP2 watchdog is GREEN

PMC:
    It has been locked 41 days, 0 hr 12 minutes
    Reflected power = 16.6W
    Transmitted power = 109.0W
    PowerSum = 125.6W

FSS:
    It has been locked for 0 days 19 hr and 29 min
    TPD[V] = 0.8165V

ISS:
    The diffracted power is around 2.4%
    Last saturation event was 0 days 19 hours and 29 minutes ago


Possible Issues: None

H1 General
oli.patane@LIGO.ORG - posted 08:04, Saturday 16 September 2023 (72909)
Ops DAY Shift Start

TITLE: 09/16 Day Shift: 15:00-23:00 UTC (08:00-16:00 PST), all times posted in UTC
STATE of H1: Observing at 148Mpc
OUTGOING OPERATOR: Tony
CURRENT ENVIRONMENT:
    SEI_ENV state: CALM
    Wind: 4mph Gusts, 3mph 5min avg
    Primary useism: 0.03 μm/s
    Secondary useism: 0.24 μm/s
QUICK SUMMARY:

Everything is looking good this morning. We're Observing and have been Locked for 18hrs.

Earthquake mode was activated between 13:04-13:14UTC.

LHO General
corey.gray@LIGO.ORG - posted 23:59, Friday 15 September 2023 (72907)
Fri Eve Ops Summary

TITLE: 09/15 Eve Shift: 23:00-07:00 UTC (16:00-00:00 PST), all times posted in UTC
STATE of H1: Observing at 148Mpc
INCOMING OPERATOR: Tony
SHIFT SUMMARY:  Uneventful shift (mostly) with H1 approaching 10hrs of lock.
LOG:

H1 TCS (OpsInfo, TCS)
corey.gray@LIGO.ORG - posted 20:20, Friday 15 September 2023 (72908)
TCSx Laser Bumps H1 Out Of Observing

Bumped out of Observing due to TCSx CO2 Laser unlocking.

( 2023-09-16_03:01:35.894099Z TCS_ITMX_CO2 [LASER_UP.run] laser unlocked. jumping to find new locking point )

TCS_ITMX_CO2 guardian node was able to restore the laser back up within 70 sec...then I took H1 back to OBSERVING.

Displaying reports 15741-15760 of 86534.Go to page Start 784 785 786 787 788 789 790 791 792 End