Starting around 11am PDT the picket fence trend plot on nuc5 started restarting itself. This was because the pnsndata service (providing stations OTR on the Washinton penninsular and LAIR at Eugene Oregon) became intermittent. To test this I took these stations out and re-ran picket fence with no issues. Later it looked like pnsndata was more stable, so I added it back in. This did not last and at 12:40 I removed it again from our client.
Note that with the west coast stations removed, the map has centered itself on Idaho.
I'll continue to monitor psnsdata and add it back when it becomes stable.
We checked with Renate Hartog (the PNSN network manager) through a series of calls and emails. She's gotten everything going now, thanks Renate!
Turns out that they had a system re-boot at about that time and people forgot to restart a (virtual) network interface. As of 17:13 pacific, the issue has been resolved and we can now connect to the PNSN.
Hopefully things will be stable and running again soon. Thanks for the notification about this Dave.
Edgard
Followed the usual instructions in the wiki, ran a broadband first, then a simulines.
Start:
PDT: 2023-10-18 12:07:24.634154 PDT
UTC: 2023-10-18 19:07:24.634154 UTC
GPS: 1381691262.634154
End:
PDT: 2023-10-18 12:30:22.282758 PDT
UTC: 2023-10-18 19:30:22.282758 UTC
GPS: 1381692640.282758
Files:
2023-10-18 19:30:21,981 | INFO | File written out to: /ligo/groups/cal/H1/measurements/DARMOLG_SS/DARMOLG_SS_20231
018T190729Z.hdf5
2023-10-18 19:30:22,019 | INFO | File written out to: /ligo/groups/cal/H1/measurements/PCALY2DARM_SS/PCALY2DARM_SS
_20231018T190729Z.hdf5
2023-10-18 19:30:22,043 | INFO | File written out to: /ligo/groups/cal/H1/measurements/SUSETMX_L1_SS/SUSETMX_L1_SS
_20231018T190729Z.hdf5
2023-10-18 19:30:22,068 | INFO | File written out to: /ligo/groups/cal/H1/measurements/SUSETMX_L2_SS/SUSETMX_L2_SS
_20231018T190729Z.hdf5
2023-10-18 19:30:22,094 | INFO | File written out to: /ligo/groups/cal/H1/measurements/SUSETMX_L3_SS/SUSETMX_L3_SS
_20231018T190729Z.hdf5
Current plans include:
Wed Oct 18 10:10:29 2023 INFO: Fill completed in 10min 25secs
Gerardo confirmed a good fill curbside.
TJ popped us out of observing so Vicky and I could touch up the OPO temperature 0.017degC (step3 of 70050) and adjust the SQZ angle 2degrees. The temperature change made the biggest difference in SQZ BLRMs, plot.
Knew this needed to happen as our range trended downwards with the SQZ BLRMS (sitemap> SQZ>Overview> SQZ Scopes> SQZ BLRMS), plot of 14 hour lock attached.
Camilla noticed an awful looking glitch in DARM today and it seems to line up with extra 3-10 Hz noise seem in our seismometer BLRMS. The magnitude of this noise today is about that of Tuesday maintenance levels, execpt that there isn't any trucks or other large equipment going on site that we are aware of. It seems to be strongest near the corner station. We will continue looking around for a possible source.
Using two periods of quiet time during the last couple of days (1381575618 + 3600s, 1381550418 + 3600s) I computed the usual coherences:
https://ldas-jobs.ligo-wa.caltech.edu/~gabriele.vajente/bruco_STRAIN_1381550418/
https://ldas-jobs.ligo-wa.caltech.edu/~gabriele.vajente/bruco_STRAIN_1381575618/
The most interesting observation is that, for the first time as far as I can remember, there is no coherence above threshold with any channels for wide bands in the low frequency range, notably between 20 and 30 Hz, and also for many bands above 50 Hz. I'll assume for now that most of the noise above ~50 Hz is explained by thermal noise and quantum noise, and focus on the low frequency range (<50 Hz).
Looking at the PSDs for the two hour-long times, the noise belowe 50 Hz seems to be quite repeatable, and follows closely a 1/f^4 slope. Looking at a spectrogram (especially when whitened with the median), one can see that there is still some non-stationary noise, although not very large. So it seems to me that the noise below ~50 Hz is made up o some stationary 1/f^4 unknown noise (not coherent with any of the 4000+ auxiliary channels we record) and some non-stationary noise. This is not hard evidence, but an interesting observation.
Concerning the non-stationary noise, I think there is evidence that it's correlated with the DARM low frequency RMS. I computed the GDS-CALIB RMS between 20 and 50 Hz (whitened to the median to weight equally the frequency bins even though the PSD has a steep slope), and the LSC_DARM_IN1 RMS between 2.5 and 3.5 Hz (I tried a few different bands and this is the best). There is a clear correlation between the two RMS, as shown in a scatter plot, where every dot is the RMS computed over 5 seconds of data, using a spectrogram.
DARM low frequency (< 4 Hz) is highly coherent with ETMX M0 and R0 L damping signals. This might just be recoil from the LSC drive, but it might be worth trying to reduce the L damping gain and see if DARM RMS improves
Bicoherence is also showing that the noise between 15 and 30 Hz is modulated according to the main peaks visible in DARM at low frequency.
We might be circling back to the point where we need to reconsider/remeasure our DAC noise. Linking two different (and disagreeing) projections from the last time we thought about this, it has the correct slope. However, Craig's projection and the noisemon measurement did not agree, something we never resolved.
Projection from Craig: https://alog.ligo-wa.caltech.edu/aLOG/index.php?callRep=68489
Measurement from noisemons: https://alog.ligo-wa.caltech.edu/aLOG/uploads/68382_20230403203223_lho_pum_dac_noisebudget.pdf
I updated the noisemon projections for PUM DAC noise, and fixed an error in their calibration for the noise budget. They now agree reasonably well with the estimates Craig made by switching coil driver states. From this we can conclude that PUM DAC noise is not close to being a limiting noise in DARM at present.
To Chris' point above -- we note that the PUMs are using 20-bit DACs, and we are NOT using and "DAC Dither" (see aLOGs motivating why we do *not* use them in LHO:68428, and LHO:65807, namely that [in the little testing that we've done] we've seen no improvement, so we decided they weren't worth the extra complexity and maintenance.)
If at some point there’s a need to test DAC dithers again, please look at either (1) noisemon coherence with the DAC request signal, or (2) noisemon spectra with a bandstop in the DAC request to reveal the DAC noise floor. Without one of those measures, the noisemons are usually not informative, because the DAC noise is buried under the DAC request.
Attached is a revised PUM DAC noisemon projection, with one more calibration fix that increases the noise estimate below 20 Hz (although it remains below DARM).
TITLE: 10/18 Day Shift: 15:00-23:00 UTC (08:00-16:00 PST), all times posted in UTC
STATE of H1: Observing at 160Mpc
OUTGOING OPERATOR: Tony
CURRENT ENVIRONMENT:
SEI_ENV state: CALM
Wind: 4mph Gusts, 2mph 5min avg
Primary useism: 0.11 μm/s
Secondary useism: 0.39 μm/s
QUICK SUMMARY: Locked for almost 12 hours. There is an acknowledged Vacuum X BT manifold AI pump alarm with a sticky note saying that it will be fixed next Tuesday.
Today at 4:45 UTC the annulus ion pump for GV8 went down to zero-ish, not a common failure, perhaps the ion pump controller failed, we (vacuum group) will take a look at the system as soon as permissible.
Late entry.
On Wednesday I had the opportunity to investigate the failure of the annulus ion pump, IFO was out of lock. The controller for the annulus ion pump did not show signs of power, the front display lights were off, see photo. Replaced the controller, and the system started working again. However, the signal for the current was a bit unusual, on a plot of the past 10 years the signal never reached such a low level, see attached plots.
And today the AIP railed high. Pump to be changed next Tuesday.
TITLE: 10/18 Eve Shift: 23:00-07:00 UTC (16:00-00:00 PST), all times posted in UTC
STATE of H1: Observing at 160Mpc
INCOMING OPERATOR: Tony
SHIFT SUMMARY: We've now been Locked for almost 4 hours and everything is looking good. When we lost lock at 10/18 01:53UTC, I had some trouble getting ALSX to lock, but no other issues besides that. The SQZ-OPO_ISS_CONTROLMON value is currently around 7.72 and has been trending slightly upward for the past hour and before that was moving downward with a shallow slope, so I don't think we will have any issues with it for the next several hours.
LOG:
23:00UTC Detector Observing and has been Locked for 1.5hours
01:53 Lockloss (73539)
03:09 NOMINAL_LOW_NOISE
03:25 Observing
04:45 X Beamtube Manifold AI Pump Major Alarm - Contacted Janos, will be fixed next Tuesday
The link to the full report: DQ_shift_report
Lockloss @ 10/18 01:53UTC
DARM_IN1(attachment1) saw some sort of glitch(left data tip) ~170ms before DARM registered the lockloss starting(right data tip).
ETMX L2 and L3 also saw this glitch(attachment2). Seems like the glitch hit DARM_IN1, then ETMX L3, then ETMX L2?
I noticed something similar with the 10/15 08:53UTC LL(attachment3), but in that case it looked like the movement was first seen in ETMX L3, then DARM_IN1 and ETMX L2. In that instance the glitch also happened a full 0.5s before the lockloss.
03:25 Back Observing
Very interesting find Oli! I've attached some more plots to hopefully help us narrow down where this is coming from. The L2 ETMX fastimon and noisemon channels see this same glitch, but the L2 OSEM sensor inputs on all of the quads don't. This makes me think that it could possible be coming from the OMC DCPD signals, the error signals forLSC-DARM. Tough to say based on data rates, but the second attachement also maybe shows the DCPD signal moving first, but take that with a grain of salt.
Naoki, Vicky, Sheila, Camilla. WP 11470.
OPO Crystal Move
Following last time we moved the OPO crystal 65684, we used the wincam dell laptop and gray E-870 PI shift driver box (stored in LVEA SQZ cabinet) and the OPO crystal cable Daniel attached the the +X HAM7 flange. Adjusted OPO temperature from 31.684 degC to 31.804 degC for co-resonance while scanning rather than stationary.
To scan the OPO PZT fast enough, we used external function generator and Thorlabs driver at the racks for the OPO PZT to scan over more than 1 FSR (around 1-9V scan).
We were able to move the OPO crytal over its full range and found 6 spots with red/green co-resonance, attached pdf shows the places we moved. LLO found 10-13 potions which is surprisingly more than us, 73502.
Through O4 we've been using the 2nd posltion from the right, but left the crystal on the 2nd spot from the Left.
Photos attached of the PZT scan (yellow trace), OPO IR trans light measured on HD PDA (pink trace), Green trans from CLF path (green trace). The green alignment looked bad at all spots. This could be from misalignment of OPO path or HOMs present in fiber. When we next go into HAM7 we can look at this.
NLG Measurement
Turn down green pump power with SQZT0 wave plate to 4mW in to stop the OPO lazing. We measured NLG of 14 (OPO_IR_PD_LF_OUTPUT amplified / unamplifed = 0.0136/0.00092). This reduced to NLG of 12 over a few minutes.
Homodyne Measurement
We balanced the HD by reducing the seed power and realigned to maximize visibility. At start of measurement visibly was 14 and at the end it NLG was 12. Vicky, Sheila Naoki took Homodyne measurements which were hard with NLG drifting. Measured 4.5dB whihc is less than the 6dB measured last week 73376. But we think we could have offloaded the ASC alignments incorrectly to not see good SQZ on the HD.
SQZ in IFO
Ended with NLG of 13.5 into IFO. Amplified power of 0.0196, unamplified seed of 0.00149. Though this may be changing quickly.
Took some no sqz data while TJ tested updates to the Observing with No SQZ wiki. Accepted sdfs to go back into observing. Vicky adjusted OPO tempurature and had to adjust the SQZ angle from 142 to 163, squeezing looks better 4dB+ but we expect the angle and OPO tempurature may need to be adjusted over the next hours...
On the bad alignment of the green to the OPO shown in Camilla's photos of the scope:
We normally apply an offset to PZT1, which we were not doing this morning. This offset impacts the cavity alignment, as you can see in Vicky's screenshots from April 2022. 62856
Here are some past alogs showing an OPO cavity scan with the green transmission.
Dec 2022: 66527 (we should do a repeat of a scan like this now, with lowered green power and a slow scan, to see if things have really degraded).
April 2022: 62691
Sept 22 we swapped the CLF collimator.
With this new crystal position, we have more squeezing in DARM, at first briefly measuring ~4.8 dB SQZ at 2kHz! It has since settled to ~4.2dB in Observe. As Camilla said, this is with the 2nd spot from the left edge (5th from the right). The optimal OPO temperature will be changing as it settles into this new spot, so there we may need to tune co-resonance temperature over the next few days to re-optimize.
Just before injecting SQZ to the interferometer, with OPO trans = 80uW, NLG was measured as 13.15. We took some sqz/asqz/meansqz loss measurements, and will do subtraction using the following times. Measurements using dtt cursors:
Loss analysis and subtraction to follow.
NLG variation over an early ~6min of operating at this new spot is interesting. I think we see the crystal's green losses increasing rapidly. In the screenshot, the OPO was locked in green (~80uW green transmitted power, but no intensity stabilization so green power varied).
edited to include: NLG measured ~7 hours later in the lockloss. After ~4 hours with stabilized green trans = 80uW, the opo co-resonance changed from 31.638 degC to 31.617 degC, and we recovered the same NLG after tuning the temperature, so the interaction strength (probably also the red losses) did not degrade much in this time.
edited to include darm sqz 15 min after relocking: SQZ reached 4.8dB again after relocking; the darker bottom SQZ trace is taken ~15 minutes into this next lock. This is operating at the new spot for ~8 hours.
For these squeezed darms at the new crystal spot, here's adding in subtracted sqz data for these times of anti-squeezing, squeezing, and mean-squeezing (i.e. LO loop unlocked, sqz phase is unlocked from the IFO beam and spinning through all sqz angles).
To see if the range changes seen when we turned up the ETM RH from 1.0W/segment to 1.2W/segment in 73445 were real, this afternoon we are reversing this change.
At 20:40UTC, Ryan took us out of Observing to reduce both H1:TCS-ETM{X,Y}_RH_SET{UPPER,LOWER}POWER to 1.1W, we'll plan to reduce all the way to 1.0W in 2 hours.
I made the second step down from 1.1 to 1.0 at 22:41UTC for H1:TCS-ETM{X,Y}_RH_SET{UPPER,LOWER}POWER.
Unsure if this made any difference to the range. Range looks improved after the step down but the wind also dropped during this change, ndscopes attached. No large change seen in DARM.
To see if the OM2/beckhoff coupling is a direct electronics coupling or not, we've done A-B-A test while the fast shutter was closed (no meaningful light on the DCPD).
State A (should be quiet): 2023 Oct/10 15:18:30 UTC - 16:48:00 UTC. The same as the last observing mode. No electrical connection from any pin of the Beckhoff cable to the OM2 heater driver chassis. Heater drive voltage is supplied by the portable voltage reference.
State B (might be noisy): 16:50:00 UTC - 18:21:00 UTC. The cable is directly connected to the OM2 heater driver chassis.
State A (should be quiet): 18:23:00- 19:19:30 UTC or so.
DetChar, please directly look at H1:OMC-DCPD_SUM_OUT_DQ to find combs.
It seems that even if the shutter is closed, once in a while very small amount of light reaches DCPDs (green and red arrows in the first attachment). One of them (red arrow) lasted long and we don't know what was going on there. One of the short glitches was caused by BS momentarilly kicked (cyan arrow) and scattered light in HAM6 somehow reached DCPDs, but I couldn't find other glitches that exactly coincided with optics motion or IMC locked/unlocked.
To give you a sense of how bad (or not) these glitches are, 2nd attachment shows the DCPD spectrum of a quiet time in the first State A period (green), strange glitchy period indicated by the red arrow in the first attachment (blue), a quiet time in State B (red) and during the observing time (black, not corrected for the loop).
FYI, right now we're back to State A (should be quiet). Next Tuesday I'll inject something to thermistors in chamber. BTW 785 was moved in front of the HAM6 rack though it's powered off and not connected to anything.
I checked H1:OMC-DCPD_SUM_OUT_DQ and don't see the comb in any of the three listed intervals (neither state A nor B). Tested with a couple of SFT lengths (900s and 1800s) in each case.
Since it seems that the coupling is NOT a direct electronics coupling from Beckhoff -> OM2 -> DCPD, we fully connected the Beckhoff cable to the OM2 heater driver chassis and locked the OMC to the shoulder with an X single bounce beam (~20mA DCPD_SUM, not 40mA like in the usual nominal low noise state). That way, if the Beckhoff is somehow coupling to OMC PZT that might cause visible combs in the DCPD.
We didn't see the comb in this configuration. See the 1st attachment, red is the shoulder lock and green is when 1.66Hz comb was visible with the full IFO (the same time reported by Ansel in alog 73000), showing just two largest peaks of 1.66Hz harmonics visible in the green trace. (It seems that the 277.41Hz and 279.07 Hz peak are 167th and 168th harmonics of 1.66Hz.) Anyway, because of the higher noise floor, even if the combs are there we couldn't have seen these peaks. We've had a different comb spacing since then (alog 73028) but anyway I don't see anything at around 280Hz. FYI I used 2048 FFTs for both, red is a single FFT and the green is an average of 6. This is w/o any normalization (like RIN).
In the top panel of 2nd attachment, red is the RIN of OMC-DCPD_SUM_OUT_DQ of the shoulder lock, blue and dark green are RIN of 2nd loop in- and out-of-loop sensor array. Magenta, cyan and blue green are the same set of signals when H1 was in observing last night. Bottom panel shows coherence between DCPD_SUM during the shoulder lock and ISS sensors as well as IMC_F, which just means that there's no coherence except for high kHz.
If you look at Georgia's length noise spectrum from 2019 (alog 47286), you'll see that it's not totally dissimilar to our 2nd plot top panel even though Georgia's measurement used dither lock data. Daniel points out that a low-Q peak at around 1000Hz is a mechanical resonance of OMC structure causing the real length noise.
Configurations: H1:IMC-PWR_IN~25.2W. ISS 2nd loop is on. Single bounce X beam. DCPD_SUM peaked at about 38mW when the length offset was scanned, and the lock point was set to the middle (i.e. 19mA). DC pointing loops using AS WFS DC (DC3 and DC4) were on. OMC QPD loops were not ON (it was enabled at first but was disabled by the guardian at some point before we started the measurement). We were in this state from Oct/17/2023 18:12:00 - 19:17:20 UTC.
BTW Beckhoff cable is still fully connected to the OM2 heater driver chassis. This is the first observation data with such configuration after Fil worked on the grounding of Beckhoff chassis (alog 73233).
Detchar, please find the comb in the obs mode data starting Oct/17/2023 22:33:40 UTC.
The comb indeed re-appeared after 22:33 UTC on 10/17. I've attached one of the Fscan daily spectrograms (1st figure); you can see it appear in the upper right corner, around 280 Hz as usual at the start of the lock stretch.
Two other notes:
Just to see if anything changes, I used the switchable breakout board at the back of the OM2 heater driver chassis to break the thermistor connections but kept the heater driver input coming from the Beckhoff. The only two pins that are conducting are pins 6 and 19.
That happened at around Oct/18/2023 20:18:00 to 20:19-something UTC when others were doing the commissioning measurements.
Detchar, please look at the data once the commissioning activities are over for today.
Because there was an elevated noise floor in the data from Oct/17/2023 18:12:00 mentioned in Keita's previous comment, there was some doubt as to whether the comb would have been visible even if it were present. To check this, we did a direct comparison with a slightly later time when the comb was definitely present & visible. The first figure shows an hour of OMC-DCPD_SUM_OUT_DQ data starting at UTC 00:00 on 10/18 (comparison time with visible comb). Blue and yellow points indicate the comb and its +/-1.235 Hz sidebands. The second figure shows the time period of interest starting 18:12 on 10/17, with identical averaging/plotting parameters (1800s SFTs with 50% overlap, no normalization applied so that amplitudes can be compared) and identical frequencies marked. If it were present with equivalent strength, it looks like the comb ought to have been visible in the time period of interest despite the elevated noise floor. So this supports the conclusion that the comb *not* present in the 10/17 18:12 data.
Following up, here's about 4 hours of DELTAL_EXTERNAL after Oct 18 22:00. So this is after Keita left only the heater driver input connected to the Beckhoff on Oct/18/2023 20:18:00. The comb is gone in this configuration.