TITLE: 10/15 Eve Shift: 23:00-07:00 UTC (16:00-00:00 PST), all times posted in UTC
STATE of H1: Earthquake
INCOMING OPERATOR: Corey
SHIFT SUMMARY: Second half of my shift had a lot of ground motion and a lockloss. We are now in NOMINAL_LOW_NOISE and just waiting for the camera servos before getting into Observing.
LOG:
23:00UTC Detector Observing and has been Locked for 35.5hours
03:54 Earthquake mode activated due to local ground motion
04:14 Back to CALM
04:14 Earthquake mode activated due to incoming earthquake from Afghanistan
04:25 DIAG_MAIN message: SERVO_BOARDS: IMC-REFL_SERVO_SPLITMON > 8V
04:30-04:38 SERVO_BOARDS: IMC-REFL_SERVO_SPLITMON > 8V message occurring more frequently
04:37-04:38 SRM saturations every few seconds
04:38 Lockloss after 41hours (73466)
04:58 Starting INITIAL_ALIGNMENT
05:36 Back to CALM
05:46 Earthquake mode activated due to local earthquake
05:56 Back to CALM
06:01 Lost lock at CHECK_AS_SHUTTERS
06:53 Reached NOMINAL_LOW_NOISE
Lockloss @ 10/15 04:38UTC
We were staying locked through an earthquake but got the DIAG_MAIN message: SERVO_BOARDS: IMC-REFL_SERVO_SPLITMON > 8V at 04:25 and then multiple times and more often in the last few minutes. SRM was constantly saturated in the last minute of the lock. T1 is where DARM_IN1 gave out.
Because ground motion is still very high and we will need to do an initial alignment, I'll be holding us in DOWN for at least ~10mins
04:58 Attempting an Initial Alignment
06:01UTC Lost lock at CHECK_AS_SHUTTERS
06:53 Reached NOMINAL_LOW_NOISE
We've been Locked for 40 hours now and are Observing at 155Mpc
Quiet night so far. useism is trending up but isn't too bad. Wind has gone up to ~15mph in the last half hour.
TITLE: 10/14 Eve Shift: 23:00-07:00 UTC (16:00-00:00 PST), all times posted in UTC
STATE of H1: Observing at 161Mpc
OUTGOING OPERATOR: Ryan C
CURRENT ENVIRONMENT:
SEI_ENV state: CALM
Wind: 5mph Gusts, 4mph 5min avg
Primary useism: 0.05 μm/s
Secondary useism: 0.29 μm/s
QUICK SUMMARY:
In Observing and Locked for 35.5 hours! Everything looking good!
TITLE: 10/14 Day Shift: 15:00-23:00 UTC (08:00-16:00 PST), all times posted in UTC
STATE of H1: Observing at 161Mpc
INCOMING OPERATOR: Oli
SHIFT SUMMARY: The microseism is still rising, winds been very low today, we've been locked for 35:27 as of 23:00UTC.
We dropped observing briefly from me miss clicking something from 18:56:29 - 18:56:47 UTC.
LOG:
No log
We dropped observing briefly from me miss clicking something from 18:56:29 - 18:56:47 UTC.
We've been locked for 31:40, everything looks stable, saturday tours ongoing.
Sat Oct 14 10:05:05 2023 INFO: Fill completed in 5min 1secs
A quick fill, LLCV had just ramped to 100% open.
TITLE: 10/14 Day Shift: 15:00-23:00 UTC (08:00-16:00 PST), all times posted in UTC
STATE of H1: Observing at 163Mpc
OUTGOING OPERATOR: Corey
CURRENT ENVIRONMENT:
SEI_ENV state: CALM
Wind: 4mph Gusts, 3mph 5min avg
Primary useism: 0.05 μm/s
Secondary useism: 0.26 μm/s
QUICK SUMMARY:
TITLE: 10/14 Eve Shift: 23:00-07:00 UTC (16:00-00:00 PST), all times posted in UTC
STATE of H1: Observing at 163Mpc
INCOMING OPERATOR: Corey
SHIFT SUMMARY: We have now been Locked for 19.5hours. PSL ISS % diff is low, around 1.9%. Uneventful evening overall, but there is an earthquake from New Zealand heading in soon. The ring heater changes that Camilla made (73445) are still okay and we will hopefully continue to not have any issues with them. I didn't notice any issues with the ETMY coildriver(73442) pop up either.
LOG:
23:00UTC Detector Observing and has been Locked for 11.5 hours
02:28 Earthquake mode activated without warning due to sudden spike in ground motion
02:38 Back to CALM
Observing at 158Mpc
Calm evening and have now been locked for 15hrs 40mins. We entered Earthquake mode from 10/14 02:28-02:38 UTC due to a small local earthquake, but managed to stay locked.
Closes FAMIS#26257, last checked 73321
Corner Station Fans (attachment1)
All fans are looking normal and within range.
Outbuilding Fans (attachment2)
All fans are looking normal and within range.
[Vicky, Regina, Dorotea, Sheila]
The attached plot shows the ratio of green light transmitted vs reflected through the OPO over the past year to see how green OPO cavity losses have changed.
We last moved the OPO crystal in Nov. 2022 (see relevant alog). Shortly after moving the crystal, the ratio was around 5% and degraded to around 4% within the first week; it has since settled between 2-3% for most of the past year.
We think the discontinuity around 23/04/16 was due to rejecting power away from the refl PD, which was done around that time because the PD was being saturated. If we look at the refl power alone we can see clear saturation occurring on the PD in the time before the power was lowered. We think the loss curve would be fairly continuous if not for the saturation, but can't exactly compensate since we don't know how much power is being lost. The plot shows only times from when the detector was "stable", but stability was calculated fairly naively, leading to some outlier points remaining from when the detector wasn't actually locked; however, the general trend seems pretty consistent.
History of crystal movements before O4, after HAM7 installation. Compared to ~1000+ steps between crystal co-resonances, the opo crystal has not really moved to a different co-resonance position since installation.
Estimating spots between crystal co-resonances: From e.g. Maggie's MIT/Lasti ilog and LLO crystal scans (e.g. LLO:49568 one side to other side of crystal was from (+3,180 and -11,820) counts, for either LLO:53429 10 co-resonance spots, or LLO:60710 13 co-resonance spots), it seems to average about (15000/13) ~ 1150 steps between fixed-temperature crystal co-resonances, save for the fine-tuning needed at each position. Compared to this ~1150 steps between crystal spots, our previous moves have basically been circling one spot.
TITLE: 10/13 Day Shift: 15:00-23:00 UTC (08:00-16:00 PST), all times posted in UTC
STATE of H1: Observing at 160Mpc
INCOMING OPERATOR: Oli
SHIFT SUMMARY: We've been locked all shift, 11:30 as of 23:00
Diag_main has been flashing with "ISS diffracted power is low" message every 10-15 minutes.
LOG:
| Start Time | System | Name | Location | Lazer_Haz | Task | Time End |
|---|---|---|---|---|---|---|
| 16:06 | PEM | Robert | LVEA, CER, CR | N | PEM tests/injections | 17:56 |
| 18:26 | VAC | Gerardo | FCES | N | Bring some equipment down, He sprayer | 19:04 |
| 19:10 | FAC | Tyler | EndY | N | Check chillers are working | 21:28 |
| 19:15 | Camilla, Jeff | MidX | N | Running down the arm | 19:46 | |
| 19:53 | VAC | Travis | Mids | N | Check out pumps, part compatibility? | 20:08 |
| 20:29 | FAC | Randy | EndX->MidX | N | Move boxes | 21:12 |
TITLE: 10/13 Eve Shift: 23:00-07:00 UTC (16:00-00:00 PST), all times posted in UTC
STATE of H1: Observing at 162Mpc
OUTGOING OPERATOR: Ryan C
CURRENT ENVIRONMENT:
SEI_ENV state: CALM
Wind: 8mph Gusts, 6mph 5min avg
Primary useism: 0.03 μm/s
Secondary useism: 0.18 μm/s
QUICK SUMMARY:
Detector is Observing and has been Locked for 11.5 hours. Dust monitors are all good and wind and useism are low.
In order to more easily track and notify on rising violin modes, I've started making a DARM BLRMS monitor around 490-520Hz. This is currently in position #8 in place of Camilla 6600-6800Hz that didn't give expected results (alog73272). It looks like its working, but not the best it could be. Jenne gave me some pointers that I'll try at another time to get this to better show us the violin mode total magnitude. Once it's looking acceptable I'll make others for the harmonics as well.
Added some more notches for the other harmonics and upped the attenuation on the bandpass. I also took over slot #9 for the 1k violin modes. I think they are working somewhat well, but I'd really like to watch this next time we have a violin mode ring up to see if it's accurate.
Both ETM RH turned up from 1.0W to 1.1W/segment at 19:03UTC, plan to increase another 0.1W later this afternoon. Follow on from 73437. Will stay in observing during this test.
Made another step up of +0.1W to 1.2W/Segment on ETMX and ETMY at 21:07UTC.
Plots attached of HOM, DARM and ndscopes. Jenne pointed out we should use GDS-CALIB for DARM as it isn't effected bt the calibration changing with the RH changes. On ndscopes, not that at -4hours theres a step in SQZ that effects the range 73446.
High frequency noise reduce, DARM maybe better in in the bucket but circulating power down 7kW and Kappa_C down 0.8%.
This doesn't seem to be doing anything bad to the range so we can leave the ETM Ring Heaters in this 1.2W setting for the weekend. If Operators have any troubles, they can reduce H1:TCS-{ETMY,ETMY}_RH_SET{UPPER,LOWER}POWER from 1.2W to 1.0W.
Adding plots of 11:00UTC,13h30 after ETM RH change. DARM ~1000Hz looks like it thermalized worse than 2 hours after the RH change. 6kHz DARM continued to reduce, but it started that lock particularly high. Circulating power settled at 367kW, 7kW less than nominal. KAPPA_C dropped nearly 1%.
These RH changes were reverted 16 October 2023 73503.