Reports until 16:23, Sunday 17 September 2023
H1 DetChar (DetChar)
zsuzsanna.marka@LIGO.ORG - posted 16:23, Sunday 17 September 2023 (72931)
Data Quality shift report 2023-09-04 to 2023-09-10

Below is the summary of the LHO DQ shift for the week of 2023-09-04 to 2023-09-10

The full DQ shift report with day by day details is available at https://wiki.ligo.org/DetChar/DataQuality/DQShiftLHO20230904

LHO General
corey.gray@LIGO.ORG - posted 16:12, Sunday 17 September 2023 (72929)
Sun EVE Ops Transition

TITLE: 09/17 Eve Shift: 23:00-07:00 UTC (16:00-00:00 PST), all times posted in UTC
STATE of H1: Observing at 146Mpc
OUTGOING OPERATOR: Oli
CURRENT ENVIRONMENT:
    SEI_ENV state: CALM
    Wind: 15mph Gusts, 9mph 5min avg
    Primary useism: 0.04 μm/s
    Secondary useism: 0.38 μm/s
QUICK SUMMARY:

Handed a 10+hr locked H1 from Oli (noticing L1 lost lock 45min ago, but they are almost back up).  Winds are slightly touching 20mph recently.

H1 General
oli.patane@LIGO.ORG - posted 16:01, Sunday 17 September 2023 (72928)
Ops DAY Shift End

TITLE: 09/17 Day Shift: 15:00-23:00 UTC (08:00-16:00 PST), all times posted in UTC
STATE of H1: Observing at 145Mpc
INCOMING OPERATOR: Corey
SHIFT SUMMARY: Still Observing and have now been Locked for 10hours. Very uneventful day.

15:00UTC In Observing, have been Locked for 2hours


LOG:

no log

H1 General (Lockloss, SEI, SUS)
oli.patane@LIGO.ORG - posted 12:52, Sunday 17 September 2023 - last comment - 10:19, Monday 18 September 2023(72927)
09/17 Lockloss Investigations

There were two locklosses during the 09/17 OWL shift, 07:45UTC and 11:30UTC.

09/17 07:45UTC Lockloss
PI24 started ringing up and wasn't able to be damped, and we lost lock 15 minutes after the ringup started(attachment1). Different from the last time we lost lock due to to the PIs (72636), as that time the phase was cycling through too fast to see if anything was helping, and was updated to wait longer before changing phase. This time the phase stopped cycling through - it just stopped trying after a few tries(SUS_PI_logtxt). It actually looks like if it had stayed at the first phase it tried, 340degrees, it might have been able to successfully damp it instead of ringing it up more(attachment2). Does this mean that checker time should be extended again? Or alternatively could we make it so if the slope of the mode increases when the phase is changed, it changes the phase in the opposite direction?
Mode24 started ringing up almost immediately after the 'super_checker' timer was completed (which turns off damping every 1/2 hour), and surpassed a value of 3 15s later, triggering the damping to turn back on.
It seems like it's a relatively common occurrance that the ESDs need to turn back on at max damping within a minute of turning off to damp mode24 or mode31.
Timeline
07:30:00 PI24 starts trending up
07:30:01 'super_checker' timer times out, turns off damping
07:30:17 PI24 exceeds 3
    - ETMY PI ESD turns on & reaches its max output in ~30s and continues at max until lockloss
    - Phase stops changing once ESD driver is at max output
07:35 PI31 also starts ringing up
07:42 DCPD saturates
07:44 PI24 reached a max of 2212
07:45 Lockloss


09/17 11:30UTC Lockloss
Caused by a 5.6 magnitude earthquake off the coast of western Canada only ~900km away from us. Seismon labeled it as two separate earthquakes from Canada that arrived at the same time, but it was only one.
Since this earthquake was so close and big, the detector wasn't given any warning, and we lost lock 4seconds after earthquake mode was activated. We actually received the "Nearby earthquake from Canada" two minutes after having lost lock!
Timeline
11:30:23 Earthquake mode activated
11:30:27 Lockloss

Images attached to this report
Non-image files attached to this report
Comments related to this report
camilla.compton@LIGO.ORG - 09:36, Monday 18 September 2023 (72935)

Looked into the SUS_PI issue and couldn't see why the phase stopped stepping.

During this time, SUS-PI_PROC_COMPUTE_MODE24_RMSMON was > 3 and the new rms from cdu.avg would have been ~11 which is larger than the old saved value of 7.94 . This should have caused SUS_PI to move forward with 'scanning mode 24 phase to damp', but it didn't. There could have been an issue with cdu.avg()? There was no reported errors with the guardian code.

    new_24_rms = cdu.avg(-5,'SUS-PI_PROC_COMPUTE_MODE24_RMSMON')
    if new_24_rms > self.old_mode24_rmsmon:
         if true then would have gone ahead with stepping phase

Images attached to this comment
camilla.compton@LIGO.ORG - 10:03, Monday 18 September 2023 (72937)OpsInfo

Vicky, Oli, Camilla. Commented out the super_timeout code from SUS_PI. PI damping will now remain on.

After talking with Oli and Vicky, it seems like the super_timeout timer isn't working as as soon as damping is turned off mode 24 rings up and damping is turned back on. This gives more opportunities for the PI damping guardian to fail as it did for this lockloss.

The super_timeout was added to turn off damping after 30 minutes as LLO saw noise from PI damping LLO67285, but we don't see noise 71737.

SUS_PI should be reloaded when we are next out of observing. Tagging OpsInfo
thomas.shaffer@LIGO.ORG - 10:19, Monday 18 September 2023 (72939)CDS

I common failure mode when using cdsutils.avg is when it can't get data from NDS for whatever reason, it returns None. In python you can still do comparison operators with Nonetypes (ie. None > 7 evaluates to False). I'd guess that's what happened here, since it wouldn't get into the code under the conditional you posted.

A solution to this is to always check that there actually is data returned, and if not try again. I'd also recommend using the timeout_utils.py call_with_timeout function to avoid times the data call gets hung.

H1 General
oli.patane@LIGO.ORG - posted 12:20, Sunday 17 September 2023 (72925)
Ops DAY Midshift Update

Observing at 144Mpc and Locked for 6hrs 25mins.

Quiet shift so far, although wind seems to have picked up a bit but not too bad.

LHO VE
david.barker@LIGO.ORG - posted 10:10, Sunday 17 September 2023 (72924)
Sun CP1 Fill

Sun Sep 17 10:08:15 2023 INFO: Fill completed in 8min 11secs

Images attached to this report
H1 CDS
david.barker@LIGO.ORG - posted 10:02, Sunday 17 September 2023 - last comment - 09:09, Monday 18 September 2023(72923)
nuc26 (video camera fom) may need a reboot

The web images from nuc26 have been frozen from 09:56 UTC (02:56 PDT) and I cannot ping this machine. If the local camera images in the control room are not updating this computer will need to be rebooted, otherwise it can wait until tomorrow.

Comments related to this report
oli.patane@LIGO.ORG - 12:33, Sunday 17 September 2023 (72926)

The nuc26 cameras in the control room were also frozen and showing that they had frozen at 09/17 06:12UTC. I also could not get into the computer remotely but I restarted the nuc and the cameras are back up and live.

david.barker@LIGO.ORG - 09:09, Monday 18 September 2023 (72934)

I have opened a FRS ticket FRS29119 and closed it as "resolved by rebooting" in case this happens again.

Aplogies, my times were incorrect. The image froze up late Sat night, 16sep 23:12 PDT (17sep 06:12 UTC).

H1 General
oli.patane@LIGO.ORG - posted 08:08, Sunday 17 September 2023 (72922)
Ops DAY Shift Start

TITLE: 09/17 Day Shift: 15:00-23:00 UTC (08:00-16:00 PST), all times posted in UTC
STATE of H1: Observing at 147Mpc
OUTGOING OPERATOR: Tony
CURRENT ENVIRONMENT:
    SEI_ENV state: CALM
    Wind: 4mph Gusts, 2mph 5min avg
    Primary useism: 0.02 μm/s
    Secondary useism: 0.28 μm/s
QUICK SUMMARY:

We are currently Observing and have been Locked for 2 hours. It looks like there were two earthquakes that were in the yellow earthquake zone during the OWL shift, causing us to lose lock twice EDIT: the two earthquakes are in USGS as just one earthquake, which makes sense since they hit us at the same time, and were only the cause of one of our locklosses. Everything will hopefully be calm now!

Images attached to this report
H1 General
anthony.sanchez@LIGO.ORG - posted 06:44, Sunday 17 September 2023 (72921)
SDF Diffs

SDF diffs Changes were made today. I'm not sure if they were intentional or not.
But since we are in NOMINAL_LOW_NOISE I'm gonna accept them.

 

 

#edit: at 2AM when I first posted this ALOG the picture of the SDF Diffs were wrong.  I have since fixed that.
same issue with ALS-Y_REFL_SERVOIN1GAIN and ALS-Y_REFL_SERVO_COMBOOST, I just accepted the changes.

 

Images attached to this report
LHO General
corey.gray@LIGO.ORG - posted 00:03, Sunday 17 September 2023 (72915)
Sat EVE Ops Summary

TITLE: 09/16 Eve Shift: 23:00-07:00 UTC (16:00-00:00 PST), all times posted in UTC
STATE of H1: Observing at 144Mpc
INCOMING OPERATOR: Tony
LOG:

LHO General
corey.gray@LIGO.ORG - posted 20:04, Saturday 16 September 2023 (72920)
EVE Mid-Shift Status

H1 recently had a lock end after just over 8hrs.  Currently waiting for H1 to get back to NLN.  

Environmentally all is well.

H1 General
oli.patane@LIGO.ORG - posted 16:58, Saturday 16 September 2023 (72918)
Ops DAY Shift End

TITLE: 09/16 Day Shift: 15:00-23:00 UTC (08:00-16:00 PST), all times posted in UTC
STATE of H1: Observing at 147Mpc
INCOMING OPERATOR: Corey
SHIFT SUMMARY: Relocking after the lockloss (72911) was a bit strange but seemed like a one-off. Rest of the day was quiet.

15:00UTC In Observing, have been Locked for 18hours

16:38 Lockloss (72911)

16:51 LOCKLOSS_PRMI during third time going through ACQUIRE_PRMI, took itself to DOWN and restarted
17:02 I took it into INITIAL_ALIGNMENT
17:32 INITIAL_ALIGNMENT completed, heading to NOMINAL_LOW_NOISE

17:42 Lockloss at OFFLOAD_DRMI_ASC

18:24 Reached NOMINAL_LOW_NOISE
18:41 Into Observing

LOG:                                                                                                            

Start Time System Name Location Lazer_Haz Task Time End
20:42   Austin+1 LExC, OSB, Overpass n tour 22:04
H1 PEM (FMP, PEM)
corey.gray@LIGO.ORG - posted 16:21, Saturday 16 September 2023 (72917)
HVAC Fan Vibrometer FAMIS Check

All looks nominal for the site HVAC fans (did catch a transition between fans at MY for this one).  Closing FAMIS 26251.

Images attached to this report
LHO General
corey.gray@LIGO.ORG - posted 16:10, Saturday 16 September 2023 (72914)
Sat EVE Ops Transition

TITLE: 09/16 Eve Shift: 23:00-07:00 UTC (16:00-00:00 PST), all times posted in UTC
STATE of H1: Observing at 147Mpc
OUTGOING OPERATOR: Oli
CURRENT ENVIRONMENT:
    SEI_ENV state: CALM
    Wind: 8mph Gusts, 6mph 5min avg
    Primary useism: 0.02 μm/s
    Secondary useism: 0.24 μm/s
QUICK SUMMARY:

H1's been locked just under 5hrs & all looks nominally from here (slight continued drift up in microseism from yesterday).

LHO VE
david.barker@LIGO.ORG - posted 10:13, Saturday 16 September 2023 (72912)
Sat CP1 Fill

Sat Sep 16 10:10:29 2023 INFO: Fill completed in 10min 25secs

Images attached to this report
H1 General (Lockloss)
oli.patane@LIGO.ORG - posted 09:40, Saturday 16 September 2023 - last comment - 17:01, Saturday 16 September 2023(72911)
Lockloss

Lockloss @ 09/16 16:38UTC. EX saturation right before/as the lockloss occurred.

Comments related to this report
oli.patane@LIGO.ORG - 11:41, Saturday 16 September 2023 (72913)

18:41 Observing

oli.patane@LIGO.ORG - 16:55, Saturday 16 September 2023 (72916)

I was able to confirm that LSC-DARM_IN1 does see the lockloss before ASC-AS_A_DC_NSUM_OUT does (attachment1), which had been brought up by TJ (72890), but I want to clarify that this isn't a recent occurance - these locklosses from July 27th(attachment2) and August 10th(attachment3) also show the lockloss in DARM_IN1 a few milliseconds before the light falls off the AS_A photodiode.

In the case of this lockloss, I could not find an obvious cause, but since there was an EX callout right before the lockloss I looked into the ETMX suspension channels that we had looked into a bit yesterday (72896).

The lockloss was seen in DARM and the DCPDs before being seen in ETMX_L3_MASTER_OUT_{UL,UR,LL,LR}_DQ channels (attachment4), followed by the AS_A channel later. However, SUS-ETMX_L3_MASTER_OUT... goes through a few filters/functions before arriving at this reading and so might have a higher latency than the DARM and DCPD channels.

The EX glitch occurred ~700ms before DARM saw the lockloss, and similarly, it was seen in DARM and the DCPDs before the ETMX L3 channels (attachment5). Not sure if this glitch could cause a lockloss (at least not on its own), since we have had glitches this big (and much bigger) in ETMX that were also seen in DARM but did not cause a lockloss, see attachment6 for an example from almost a day earlier.

Thinking about what Camilla said in (72896) "ETMX moving would cause a DARM glitch (so the DARM BLRMs to increase) or vice versa, DARM changing would cause ETMX to try to follow", in this case depending on the latency either could still be true but I don't see why we would lose lock from a (relatively) mid-size saturation but hold on during a larger one unless there was some other factor (which I guess there probably usually is).

Images attached to this comment
oli.patane@LIGO.ORG - 17:01, Saturday 16 September 2023 (72919)

Relocking after this lockloss:

Lost lock after going through ACQUIRE_PRMI three times, so I decided to run an initial alignment. Initial alignment completed fine and we started locking and moving through states quickly, but then we lost lock at OFFLOAD_DRMI_ASC. I let it try locking again and everything was fine, so seems like that OFFLOAD_DRMI_ASC lockloss was just a one-off strange lockloss.

Displaying reports 17821-17840 of 88618.Go to page Start 888 889 890 891 892 893 894 895 896 End