austin.jennings@LIGO.ORG - posted 20:53, Saturday 10 June 2023 (70333)
Lockloss @ 3:43 UTC

LOCKLOSS @ 3:43, this one might be from the EQ. Interestingly enough, SEI_CONF went to CALM (it went to the EQ state, but there was no indicator on Verbal that it ever transitioned in the first place?), and we lost lock shortly after. Notice right after the lockloss the MC_TRANS camera was moving quite significantly in pitch, more evidence that this was potentially motion related.

However, the peakmon ndscope was showing very little movement (~100 counts at the time of the lockloss - scope attached), also the BLRMS for the EQ band was at or right below 0.1 um/s. This is pretty contradictiory, I'm wondering if this was just a coincidence and not EQ related at all? Tagging SEI

EDIT: The lockloss tool did not tag any ground motion related tags, and the lockloss select tool is not showing any ASC/LSC ringups from my eye, conclusion: inconclusive.

Images attached to this report
H1 General (ISC, Lockloss)
austin.jennings@LIGO.ORG - posted 16:41, Saturday 10 June 2023 (70332)
Lockloss @ 23:35 UTC

LOCKLOSS @ 23:53, looking at the lockloss select, potentially movement in CSOFT P, also noticing some instability in the LSC loops as well - scope attached - Tagging ISC

Images attached to this report
H1 General (SUS)
anthony.sanchez@LIGO.ORG - posted 16:13, Saturday 10 June 2023 (70329)
Saturday OPS Day Shift End

TITLE: 06/10 Day Shift: 15:00-23:00 UTC (08:00-16:00 PST), all times posted in UTC
STATE of H1: Observing at 137Mpc
CURRENT ENVIRONMENT:
    SEI_ENV state: CALM
    Wind: 7mph Gusts, 5mph 5min avg
    Primary useism: 0.02 μm/s
    Secondary useism: 0.09 μm/s
QUICK SUMMARY:

17:21 UTC a tour group came through the control room.
Confirmed a slow Climb in IMY Mode5. Gain H1:SUS-ITMY_L2_DAMP_MODE5_GAIN was set at -0.04 and I changed it to 0.
Looking at alog 70057 https://alog.ligo-wa.caltech.edu/aLOG/index.php?callRep=70057  I will try a gain of +0.01

Lockloss 19:50 UTC of unknown cause.   

Locking Summary:
No Initial alignment was done before trying to lock again.
DRMI 1f didn't lock but i let it go to Aquire PRMI which then locked and we went on up.
NOMINAL_LOW_NOISE Reached at 21:04 UTC
Intention bit set to Observing 21:09 UTC.

Violin Modes:
ITMY mode 8 is increasing again. I will take the gain to 0 then then up to +0.04 as described in the following alog.  
https://alog.ligo-wa.caltech.edu/aLOG/index.php?callRep=70057
That singular change of gain did not make any difference, but taking the gain back to 0 then turning on FM7 which is a -30 deg phase change then bringing the gain back up to 0.04 did start bringing ITMY Mode 5 down. Tagging SUS

IFO Current Status: NOMINAL_LOW_NOISE & Observing

 

LHO General
austin.jennings@LIGO.ORG - posted 16:03, Saturday 10 June 2023 (70328)
Ops Eve Shift Start

TITLE: 06/10 Eve Shift: 23:00-07:00 UTC (16:00-00:00 PST), all times posted in UTC
STATE of H1: Observing at 135Mpc
CURRENT ENVIRONMENT:
    SEI_ENV state: CALM
    Wind: 8mph Gusts, 4mph 5min avg
    Primary useism: 0.03 μm/s
    Secondary useism: 0.08 μm/s 
QUICK SUMMARY:

- SEI/DM/CDS ok

- H1 is locked and in observing as of 21:04 UTC

H1 DetChar (ISC, TCS)
evan.hall@LIGO.ORG - posted 14:10, Saturday 10 June 2023 (70305)
Lock-time distribution of data accumulated during O3

The first attachment shows the distribution of data during O3, ordered by how long into a high-power lock stretch the data were taken. High-power lock segments were identified by either H1:GRD-LASER_PWR_OK:1 or L1:GRD-PSL_OK:1. Solid lines show the data during observing mode only ([HL]1:DMT-ANALYSIS_READY:1); dashed lines show all data accumulated during high-power operation.

Half of observing-mode data were accumulated within the first 9 hours of lock, a third of data were accumulated within the first 6 hours of lock, and a fifth of data were accumulated within the first 3 hours of lock. The distributions are remarkably similar between H1 and L1, and so far, L1's distribution for the first few weeks of O4 seems similar to the distributions for O3.

The second attachment shows the distribution of data during O3, ordered just by total lock length (i.e., without regard to how far into a particular lock stretch the data were taken). Half of observing-mode data were accumulated during locks of more than 20 hours.

Non-image files attached to this report
H1 General
anthony.sanchez@LIGO.ORG - posted 14:01, Saturday 10 June 2023 - last comment - 16:17, Saturday 10 June 2023(70327)
Lockloss June 10th 19:50

Lockloss occured at 19:50 UTC:
Lockloss select URL : https://ldas-jobs.ligo-wa.caltech.edu/~lockloss/index.cgi?event=1370461864
 

Cause currently unknown, awaiting analysis.

CURRENT ENVIRONMENT:
    SEI_ENV state: CALM
    Wind: 4mph Gusts, 2mph 5min avg
    Primary useism: 0.01 μm/s
    Secondary useism: 0.08 μm/s

Images attached to this report
Comments related to this report
austin.jennings@LIGO.ORG - 16:17, Saturday 10 June 2023 (70330)

After running lockloss select, it looks like INP1 and CSOFT were potentially ringing up at 0.1 Hz.

Images attached to this comment
LHO VE
david.barker@LIGO.ORG - posted 10:15, Saturday 10 June 2023 (70326)
Sat CP1 Fill

Sat Jun 10 10:11:44 2023 INFO: Fill completed in 11min 43secs

 

Images attached to this report
H1 General
anthony.sanchez@LIGO.ORG - posted 08:01, Saturday 10 June 2023 (70325)
Satuday OPS Day Shift Start

TITLE: 06/10 Day Shift: 15:00-23:00 UTC (08:00-16:00 PST), all times posted in UTC
STATE of H1: Observing at 138Mpc
CURRENT ENVIRONMENT:
    SEI_ENV state: CALM
    Wind: 5mph Gusts, 4mph 5min avg
    Primary useism: 0.01 μm/s
    Secondary useism: 0.10 μm/s
QUICK SUMMARY:
Current IFO Status: NOMINIAL_LOW_NOISE and OBSERVING for 6+ hours.


 

LHO General
ryan.short@LIGO.ORG - posted 08:00, Saturday 10 June 2023 (70324)
Ops Owl Shift Summary

TITLE: 06/10 Owl Shift: 07:00-15:00 UTC (00:00-08:00 PST), all times posted in UTC
STATE of H1: Observing at 140Mpc
SHIFT SUMMARY: Mostly quiet shift after relocking and riding out earthquakes.

Handing off to Tony for the day.


LOG:

No log for this shift.

H1 General (CAL)
ryan.short@LIGO.ORG - posted 01:44, Saturday 10 June 2023 (70323)
H1 Resumes Observing

H1 has relocked and is Observing as of 08:37 UTC. There was one SDF diff on the CALEX model when we reached NLN regarding a PCal X OSC time ramp that appears to have been changed at the time of last lockloss. Since this is just a time ramp, it seemed harmless enough to revert it, which I did (tagging CAL, screenshot attached).

Images attached to this report
LHO General
austin.jennings@LIGO.ORG - posted 00:05, Saturday 10 June 2023 (70315)
Friday Eve Shift Summary

TITLE: 06/09 Eve Shift: 23:00-07:00 UTC (16:00-00:00 PST), all times posted in UTC
STATE of H1: Observing at 136Mpc
SHIFT SUMMARY:

- IFO was stable and locked up until the end of my shift, passing H1 to Ryan with the IFO relocking

- Lock #1:

LOG:

No log for this shift.

LHO General
ryan.short@LIGO.ORG - posted 00:04, Saturday 10 June 2023 (70320)
Ops Owl Shift Start

TITLE: 06/10 Owl Shift: 07:00-15:00 UTC (00:00-08:00 PST), all times posted in UTC
STATE of H1: Lock Acquisition
CURRENT ENVIRONMENT:
    SEI_ENV state: CALM
    Wind: 10mph Gusts, 8mph 5min avg
    Primary useism: 0.01 μm/s
    Secondary useism: 0.10 μm/s
QUICK SUMMARY: Taking over from Austin. H1 lost lock @ 06:53 just before handoff; looks like an ASC ringup at 0.45Hz. Currently relocking ALS.

H1 General (ISC, Lockloss)
austin.jennings@LIGO.ORG - posted 00:02, Saturday 10 June 2023 (70321)
Lockloss @ 6:53 UTC

LOCKLOSS @ 6:53, looking at the lockloss select, potentially movement in CSOFT P, potentially INP1 P/Y and DHARD Y - scope attached - Tagging ISC

Images attached to this report
LHO General
austin.jennings@LIGO.ORG - posted 20:02, Friday 09 June 2023 (70319)
Mid Shift Eve Report

H1 has been locked for just over 5 hours. There has been a couple of DCPD and EX saturations alongside what looks to be CHARD P ringups, but the IFO looks to have stabilized.

H1 SEI (CDS, SEI)
erik.vonreis@LIGO.ORG - posted 16:49, Friday 09 June 2023 (70318)
Picket Fence updated

Picket Fence was updated to replace the seismometer used on the channel 1 stream, which had not been working for some time.

H1 CDS
david.barker@LIGO.ORG - posted 16:36, Friday 09 June 2023 - last comment - 13:01, Tuesday 13 June 2023(70317)
unresponsive filters not under local model control

Following up on EJ's alog, I have extended the code to check if the unresponsive filter is under local control by the model. I ran it this afternoon while H1 was in observe, running in 'nice' mode so as to not hammer the frontends with CA requests (delays between requests).

If we disregard locally controlled filters, the number of unresponsive filters is reduced to 3 (see attached). The top one runs on h1lsc, the other two on h1lscaux.

Here is the full list, with locally controlled filters marked with *

Total numer of filtermodules = 13367
num unresponsive 14

h1lsc {'LSC-EXTRA_AI_2': 'FM2  '}

h1lscaux {'LSC-LOCKIN_1_DEMOD_9_I': 'FM1  ',
          'LSC-LOCKIN_1_DEMOD_9_Q': 'FM1  '}

h1sqz {'SQZ-RLF_VCXO_SERVO': 'FM2* '}

h1alsex {'LSC-X_ARM_DRIVE': 'FM3* FM5* '}

h1alsey {'LSC-Y_ARM_DRIVE': 'FM3* FM5* '}

h1sussqzin {'SUS-ZM1_M2_COILOUTF_LL': 'FM1* FM6* ',
            'SUS-ZM1_M2_COILOUTF_LR': 'FM1* FM6* ',
            'SUS-ZM1_M2_COILOUTF_UL': 'FM1* FM6* ',
            'SUS-ZM1_M2_COILOUTF_UR': 'FM1* FM6* ',
            'SUS-ZM3_M2_COILOUTF_LL': 'FM1* FM6* ',
            'SUS-ZM3_M2_COILOUTF_LR': 'FM1* FM6* ',
            'SUS-ZM3_M2_COILOUTF_UL': 'FM1* FM6* ',
            'SUS-ZM3_M2_COILOUTF_UR': 'FM1* FM6* '}
 

 

 

 

 

Images attached to this report
Comments related to this report
daniel.sigg@LIGO.ORG - 14:38, Monday 12 June 2023 (70378)

Turned thses filters off:

h1lsc {'LSC-EXTRA_AI_2': 'FM2  '}
h1lscaux {'LSC-LOCKIN_1_DEMOD_9_I': 'FM1  ',
          'LSC-LOCKIN_1_DEMOD_9_Q': 'FM1  '}

Added gain of 1 filters to:

h1sqz {'SQZ-RLF_VCXO_SERVO': 'FM2* '}
h1sussqzin {'SUS-ZM1_M2_COILOUTF_LL': 'FM1* FM6* ',
            'SUS-ZM1_M2_COILOUTF_LR': 'FM1* FM6* ',
            'SUS-ZM1_M2_COILOUTF_UL': 'FM1* FM6* ',
            'SUS-ZM1_M2_COILOUTF_UR': 'FM1* FM6* ',
            'SUS-ZM3_M2_COILOUTF_LL': 'FM1* FM6* ',
            'SUS-ZM3_M2_COILOUTF_LR': 'FM1* FM6* ',
            'SUS-ZM3_M2_COILOUTF_UL': 'FM1* FM6* ',
            'SUS-ZM3_M2_COILOUTF_UR': 'FM1* FM6* '}

 

This should have no effect on anything.

daniel.sigg@LIGO.ORG - 13:01, Tuesday 13 June 2023 (70417)

Remove the controls from these filter modules:

h1alsex {'LSC-X_ARM_DRIVE': 'FM3* FM5* '}
h1alsey {'LSC-Y_ARM_DRIVE': 'FM3* FM5* '}

Turned these filters off after a model restart.

H1 General
anthony.sanchez@LIGO.ORG - posted 16:11, Friday 09 June 2023 (70316)
Friday OPS Day Shift End

TITLE: 06/09 Day Shift: 15:00-23:00 UTC (08:00-16:00 PST), all times posted in UTC
STATE of H1: Observing at 137Mpc
CURRENT ENVIRONMENT:
    SEI_ENV state: CALM
    Wind: 7mph Gusts, 5mph 5min avg
    Primary useism: 0.04 μm/s
    Secondary useism: 0.10 μm/s
QUICK SUMMARY:

At 20:10 UTC the SQZ_MANAGER went from FREQ_DEP_SQZ to SQZ_READY_IFO for some reason

20:15 UTC lockloss.
 
Relocking Notes: I had to Touch up X-ARM ALS Flashes.

Doors to Air handlers 1 & 2  were open from 1:35-138 local so if there is som etrending of the Air handlers during that time the plots may look diiffent than expected during those time.

Took ISC_LOCK to Initial Alignment 20:46 UTC
Started the Next Locking attempt 21:07
21:55 UTC Nominal Low Noise was reached.

Saved some SDF Changes to H1:ASC-ADS_PIT3_DEMOD_I_TRAMP  for PIT 3-5 and Yaw 3-5 after speaking to Naoki about some changes.

Current IFO Status: Nominal Low Noise And Observing for 1 Hour.

                                                                                                           

Start Time System Name Location Lazer_Haz Task Time End
20:34 FMCS Tyler & Bubba AirHandlr2 N checking out the HVAC system 21:56
LHO General
austin.jennings@LIGO.ORG - posted 16:01, Friday 09 June 2023 (70314)
Ops Eve Shift Start

TITLE: 06/09 Eve Shift: 23:00-07:00 UTC (16:00-00:00 PST), all times posted in UTC
STATE of H1: Observing at 137Mpc
CURRENT ENVIRONMENT:
    SEI_ENV state: CALM
    Wind: 5mph Gusts, 2mph 5min avg
    Primary useism: 0.05 μm/s
    Secondary useism: 0.09 μm/s
QUICK SUMMARY:

- IFO locked and in observing for ~1 hr

- CDS/DMs ok

- Seismic motion a bit elevated from recent EQ, will monitor

H1 General (CDS, PEM, SUS)
camilla.compton@LIGO.ORG - posted 08:05, Tuesday 06 June 2023 - last comment - 01:27, Saturday 10 June 2023(70170)
OPS Owl Shift Summary

TITLE: 06/06 Owl Shift: 07:00-15:00 UTC (00:00-08:00 PST), all times posted in UTC
STATE of H1: Observing at 133Mpc
SHIFT SUMMARY: About to start maintenance day.
LOG:

H1 glitches nuc27 FOM isn't updating for Omicrom. I posted this in the LHO DetChar chat.ligo group.

I've had to restart the DARM FOM on nuc30 3 times and Ryan noted he did ~4 times during the evening. Tagging CDS.

I expected PEM magnetic injections to start at 7:25am, it was 14:30UTC to 14:48UTC. SUS_CHARGE started at 14:45UTC with lines at 11-14Hz when PEM_MAG_INJ was stilll at EY_EBAY_HIGH_INJ. So they overlapped by 2-3 minutes.  Tagging PEM and Tagging SUS  In-lock charge measurements caused a lockloss again at 15:00UTC 70062.

Start Time System Name Location Lazer_Haz Task Time End
13:21 CDS Erik Remote N Rebooting work stations 13:21
14:17 COMM Camilla CR N PRCL OLG Measurement 14:27
14:30 PEM PEM_MAG_INJ GRD Auto N Automatic magnetic injections 14:48
14:45 SUS SUS_CHARGE GRD Auto N Automatic in-lock charge measurements 15:01
 
 
Lock #1 Locked for 12h.
Lost lock at 09:37UTC, cause was 11Hz PRCL instability, plot in 70169. Aso a small EQ coming through in the ~minute after. This is with Jenne's updated PRCL2 gain of 1.7 70160.
 
Relocking:
Successfully did an initial alignment after couldn't lock PRMI (with moving PRM) and we lost lock at CHECK_MICH_FRINGES. Since then locking has been fine, currently at MAX_POWER.
SQZ_OPO_LR guardian had error message "Disabled pump iss after 20 locklosses, reset counter to clear message"  so I followed instructions in 68695, taking SQZ_OPO_LR guardian to LOCKED_CLF_DUAL_NO_ISS and then back to the nominal LOCKED_CLF_DUAL.
 
Lock #2 NLN @ 11:22, Observing @ 11:34UTC. Locked for 1h26.
Reverted sdf so that we have the updated PRCL2_GAIN of 1.7 in this lock 70160. There was a 3 sec ramp time.
Lost lock at 12:48UTC 1370090939. Don't know why. Not PI, not PRCL 11Hz.
 
Relocking
100% automated!
 
Lock #3  NLN @ 13:55, Observing @ 14:05UTC.
Again reverted sdf so that we have the updated PRCL2_GAIN of 1.7 70160.
Had both PI24 and PI31 ring up and damp 1 hours inot the lock, with in-lock charge measurements going, see attached.
Images attached to this report
Comments related to this report
ryan.short@LIGO.ORG - 01:27, Saturday 10 June 2023 (70322)PEM

To fix the overlap between the magnetic injections and in-lock charge measurements, I've moved the start time of the magnetic injections up to 7:20am from 7:25am (tagging PEM).