Displaying reports 19361-19380 of 87654.Go to page Start 965 966 967 968 969 970 971 972 973 End
Reports until 13:59, Monday 12 June 2023
H1 OpsInfo (ISC, Lockloss)
jim.warner@LIGO.ORG - posted 13:59, Monday 12 June 2023 (70375)
Lockloss at 20:32 caused by a misclick on LSC TRPD screen, so I got mad at the hammer

While we were locked observing, I was digging through LSC screens trying to look for PD sum channels to trend for some lock loss investigations. Not knowing these screens well, I accidentally switched the LSC_CUST_TRPD screen from the QPD B SUM pd to the Inair PD. This didn't go well, and I didn't get the PD overview I was hoping for. I modfied the screen a little bit to try to make this a little more clear to neophytes. The only working link to a separate screen is now orange and I added a "PD select:" label to the buttons I clicked.

Images attached to this report
H1 AOS
betsy.weaver@LIGO.ORG - posted 13:34, Monday 12 June 2023 (70374)
New alignment pointing after LVEA temps stabilized

(Although the word "stabilized" is used loosely.)

Now that temperatures have seemed to settle in, attached* is a longer trend of the PR3, BS, and SR3 showing their new positions at these new LVEA temperatures.  Note, this is a follow-on from Kissel's historical alog summary of the HVAC temperature changes 70284.

Recall that there were a few HVAC fan/setting changes with subsequent issues, failures, adjustments, and fire alarm testing interuptions which spanned the last month and rolled past just Tuesday maint periods.  The PR3, BS, and SR3 seem to have slewed to new positions starting at the last LVEA temp change ~May 25th and have now settled in.

* V_INMON is the vertical channel for these suspensions - if the V channel shows change, it likely means that Pitch and or Yaw have also changed (PR3 pitch is shown to demonstarte).  I confirmed this with previous plots, but chose to only plot this version since V tells the main story of epochs.

* Only 1 LVEA temp plot is shown for ease of viewing, but I checked via erlier versions of the plot that this zone temp change of over 1.5deg F is typical for what has been observed in the LVEA on other sensors.

We are still sorting new/old noise sources and any other such fallout from this new IFO alignment position.

Images attached to this report
H1 DetChar (DetChar)
beverly.berger@LIGO.ORG - posted 12:50, Monday 12 June 2023 (70372)
DQ Shift Report at LHO for 5 June 2023 - 11 June 2023

Beverly Berger, Quynh Lan Nguyen, Brina Martinez

The complete report may be found here.
LHO VE
david.barker@LIGO.ORG - posted 10:25, Monday 12 June 2023 (70365)
Mon CP1 Fill

Mon Jun 12 10:10:54 2023 INFO: Fill completed in 10min 53secs

Gerardo confirmed a good fill curbside.

Images attached to this report
H1 ISC
daniel.sigg@LIGO.ORG - posted 09:52, Monday 12 June 2023 (70363)
71MHz RF amplifier in EY

Adjusted the nominal output power of the 71MHz RF amplifier in EY to 19.5. The output power seems to be on a slow downward drift over the past 10 years.

Images attached to this report
H1 PSL
ryan.short@LIGO.ORG - posted 08:15, Monday 12 June 2023 (70361)
PSL Cooling Water pH Test

FAMIS 19962

pH of PSL chiller water was measured to be between 10.0 and 10.5 according to the color of the test strip.

H1 General
anthony.sanchez@LIGO.ORG - posted 08:10, Monday 12 June 2023 (70360)
Monday OPS Day Shift Start

TITLE: 06/12 Day Shift: 15:00-23:00 UTC (08:00-16:00 PST), all times posted in UTC
STATE of H1: Observing at 133Mpc
CURRENT ENVIRONMENT:
    SEI_ENV state: CALM
    Wind: 16mph Gusts, 13mph 5min avg
    Primary useism: 0.03 μm/s
    Secondary useism: 0.12 μm/s
QUICK SUMMARY:
IFO Current Status: Locked in NOMINAL_LOW_NOISE & OBSERVING.

LHO General
ryan.short@LIGO.ORG - posted 08:02, Monday 12 June 2023 (70359)
Ops Owl Shift Summary

TITLE: 06/12 Owl Shift: 07:00-15:00 UTC (00:00-08:00 PST), all times posted in UTC
STATE of H1: Observing at 135Mpc
SHIFT SUMMARY: One lockloss and simple reacquisition. H1 has been locked and observing for just over an hour.

Lock #1:

Lock #2:

The DARM diaggui window on nuc30 has been periodically crashing for the past couple of hours (tagging CDS).

Handing off to Tony for the day.


LOG:

No log for this shift.

H1 General (Lockloss)
ryan.short@LIGO.ORG - posted 05:22, Monday 12 June 2023 (70358)
Lockloss @ 12:12 UTC

Lockloss @ 12:12 UTC

Cause not entirely obvious, all I've noticed so far is potentially a ringup in CSOFT_P prior to the lockloss.

LHO General
ryan.short@LIGO.ORG - posted 04:09, Monday 12 June 2023 (70357)
Ops Owl Mid Shift Update

State of H1: Observing at 136Mpc

H1 has been locked and Observing for close to 4 hours. Slight wind, seismic activity is low.

H1 PSL
ryan.short@LIGO.ORG - posted 02:14, Monday 12 June 2023 (70356)
PSL 10-Day Trends

FAMIS 19980

The break in PMC/FSS/ISS close to zero on the stabilization plots is a result of the PMC being unlocked while diagnosing an issue described in alog 70352

Images attached to this report
LHO General
austin.jennings@LIGO.ORG - posted 22:23, Sunday 11 June 2023 - last comment - 11:06, Monday 12 June 2023(70352)
Mid Shift Eve Report

H1 is down and in corrective maintanence to troubleshoot an issue with the PMC. Currently working with team PSL to diagnose the cause.

Comments related to this report
jason.oberling@LIGO.ORG - 23:37, Sunday 11 June 2023 (70353)PSL

J. Oberling, R. Savage, A. Jennings

Logged in from home, all signals looked OK, we had RF and high voltage to the PZT, signal on the locking PD, and the ramp worked.  Tried locking and got nothing.  There was no obvious reason why it wouldn't lock (same as Ryan and Jenne saw when Austin called them).  Since I couldn't tell what the issue was from home, I drove to the site to take a look; Rick joined in case we needed to swap something out.  Austin took a look at the electronics (PSL rack and CER), and I confirmed, all electronics visibly OK, nothing seemed out of place.  Decided to watch the signal on the locking PD and turned on the PZT ramp.  Flashes could be seen, but nothing down around the trigger threshold level, so I increased it from 0.1 V to 0.2V (where I had seen the threshold drop to a couple times), and the PMC locked right up without issue.  First attachment shows when I changed the locking threshold and the resulting relock.  Not sure why the threshold needed to be changed, but it's locked now.  Unlocked and locked it several times, and it locked every time without issue.  For some reason I currently do not know, the PMC would consistently not lock with a threshold of 0.1V, even if the locking PD voltage dropped below 0.1V; the 2nd attachment shows several instances when the PD voltage dropped below 0.1V, but the PMC did not lock (if the PMC locked then the PD voltage would have dropped to its usual locked value of ~20mV).  This threshold value has been in place since at least the end of the 2021 PSL laser upgrade (likely back during O3 as well), so I'm not sure why the sudden change (and why I didn't think to try this first; lesson learned).  I tried with the locking threshold at 0.15V, and this also locked without issue (3rd attachment), so I left the threshold here.  I accepted the change in SDF; I didn't get a screenshot but did get a picture with my phone, will add that as a comment to this alog.  At the time of this writing Austin has gone through an initial alignment and is now trying to lock the IFO; PMC so far has been stable, will monitor through this locking process.

Images attached to this comment
jason.oberling@LIGO.ORG - 11:06, Monday 12 June 2023 (70368)

FRS ticket 28260 has been created to track this issue.

H1 CDS
david.barker@LIGO.ORG - posted 21:51, Sunday 11 June 2023 - last comment - 09:58, Monday 12 June 2023(70350)
Atomic Clock 1PPS out-of-range on MSR timing comparitor

The timing system has a corner station error: the MSR atomic clock 1PPs difference went from -159nS to 0.11S at 19:31 PDT this evening.

This signal is for verification purposes and does not drive the timing system. We will take a look at what has happened to it in the morning.

Images attached to this report
Comments related to this report
david.barker@LIGO.ORG - 21:57, Sunday 11 June 2023 (70351)
daniel.sigg@LIGO.ORG - 09:58, Monday 12 June 2023 (70364)

The atomic clock was fairly stable over the past 50 days or so, and then jumped. Not sure what could cause this short of a power glitch.

Images attached to this comment
H1 General (SEI)
ryan.short@LIGO.ORG - posted 07:20, Sunday 11 June 2023 - last comment - 14:26, Monday 12 June 2023(70339)
Lockloss @ 14:14 UTC

Lockloss @ 14:14 UTC from a magnitude 5.8 earthquake from New Zealand. This lockloss happened at the same time as seismic configuration moved to EARTHQUAKE.

Holding in DOWN for ground motion to settle, then will start relocking.

Images attached to this report
Comments related to this report
elenna.capote@LIGO.ORG - 14:26, Monday 12 June 2023 (70376)

Just a note that the lockloss tool did not log this as an earthquake lockloss. The buildups are very clearly oscillating at low frequency in the last few minutes leading up to the lockloss, and the seismic FOM shows increased ground motion. I am not sure what triggers an earthquake tag in the lockloss tool but I figured it would be useful to know that the tool did not properly classify this one.

H1 SEI (CSWG, ISC, SUS)
jeffrey.kissel@LIGO.ORG - posted 15:19, Friday 09 June 2023 - last comment - 13:58, Monday 12 June 2023(70306)
Comparing Differential HAM2-HAM3 Motion vs. Local Motion
J. Kissel, S. Koehlenbeck, B. Lantz

Sina and I are putting together material to help motivate an SPI installation some time in the future (see most recent material in G2300655 and G2300846), and one of the open questions is whether we can demonstrate (via model, or extrapolated measurement) that the P & Y input to, say, PR3 would be better after linking the platforms together in PITCH & YAW than the local table PITCH (RY) & YAW (RZ).

This aLOG shows the first attempt at demonstrating this with data, sticking with PR3, and thus the HAM2 - HAM3 ISI system. 

Executive Summary: This initial look shows great promise for an SPI's ability to improve HAM2 and HAM3 platform motion across the 0.01 to 10 Hz frequency band -- differential X (longitudinal), as well as differential Y and Z converted to pitch and yaw motion, is factors of 2 to 200 better than local X (longitudinal), RY (pitch), and RZ (yaw).


The key concepts here are
    - As it's *always* worth repeating, the input to the suspension point is different from table motion, and the optic motion is different that optic motion, *especially* when it comes to cross-coupling between degrees of freedom, like suspension point Longitudinal and optic Pitch, or platform X / RZ vs. optic Yaw. Even within the ISI, there's a good amount of cross coupling between RX/RY tilt DOFs and Y/X translation degrees of freedom, so using the SPI to improve ISI RY could improve ISI Y, which benefits PR3 suspoint L, with benefits PR3 optic P. So the motivation for an SPI, via looking at only one diagonal DOF at once will never make a clear argument for "we need an SPI!" So, we're doing an incomplete job if we look at only one DOF at once and say "improvements in this one DOF will clearing improve that one DOF." We'll only really know the true quantified benefit once we install one and see. But it's still interesting to look at the data in this way to get a feel for if it makes sense to even try.

    - The SPI may be used for different frequency regions for different purposes. PR3, for example, may not be limited by residual seismic motion at some frequencies for some degrees of freedom. We just need to be conscious of this when make sweeping statements like "PR3 is completely dominated by OSEM noise, you won't see any improvement unless we improve the local sensors on the top mass of PR3 -- so why should we spend energy on an SPI?" because that sweeping statement is true at 10 Hz, but not true below ~3 Hz, and an improvement below 3 Hz might be benefit to the IFO in subtle ways like "we can reduce the bandwidth of the ASC loops, which means the ASC sensor noise doesn't couple into DARM at 10-15 Hz." 

    - In modern parlance, when we say an "SPI" we really mean a 3 DOF collection of sensors rather than "just" a 1 DOF seismic platform interferometer: 
        :: SPI L :: a longitudinal sensor -- the interferometer part, which uses an asymmetric michelson IFO (short arm stays local to the launching platform, and the long arm spans the 16 m distance between the two platforms) to determine the relative distance between the platforms. 
        :: SPI P :: an "optical lever" like pitch sensor measuring differential pitch of the platform (expected to be dominated by the difference between local Zs rather than local pitch RYs) 
        :: SPI Y :: an "optical lever" like yaw sensor, measuring differential yaw of the platform (expected to me dominated by the difference between local Ys, rather than differential yaw RZs)

    - Fundamentally, why an SPI wins in P and Y is the lever arm of sensing. The local sensing of pitch (RX / RY) or yaw (RZ) is the difference or sum of inertial sensors across the width of the table, a lever arm of ~1 [m]. One the other hand, if we can tie pitch/RY or yaw/RZ one platform (say HAM2) to the other (HAM3), but using the lever arm *between* the platforms -- L = ~16 [m] -- and this is *better* than the local interial sensing, we improve both local platform's motion by something like sqrt(2) / L. The details of of the improvement depend on a lot of things, and we'll get there, but at least conceptually, this is the promised improvement.

    - Another point to emphasize is that *we don't yet know the optimal controls topology and/or frequency region that these 3 DOFs will be used.* Depending on the results, it may be interesting to compare the local inertial sensors to the SPI sensors, or the local CPS to the SPI sensors. What frequency region we blend in the SPI vs. the local platform's inertial and displacement sensor array is still unclear. So the plots below compare both against the SPI. You'll see that the differential signals are better in some frequency regions and worse in others. This is all still to be understood and schemed upon, so my commentary below should be treated as "first impressions."

    - Remember that depending on the frequency band, the CPS or GS13s are "in loop," forming the error signal for the feedback loops, which have UGFs of around 30 Hz. I indicate a "CPS Rolloff Frequency" with vertical lines on all the plots -- where the vertical line is set at the frequency above which the CPS contribution to the super sensor is less than 1.0. (Note, this is different from what has traditionally been referred to as "the blend frequency," which is instead a center point of equal contributions of GS13 and CPS. Because 
        - gain peaking is involved at that "blend frequency" cross-over point, 
        - that gain peaking can be large and/or span across a lot of frequency space, 
        - GS13 blend filters are not easy to plot because of the embedded inertial sensor calibration and
        - AFAIK, no one's plotted them in their easy-to-digest complementary form recently, 
    I chose the more straight-forward, easily findable, "when does the CPS contribution to the feedback loop start to roll off" frequency. These frequencies are close, of course, but not the same.)

    - I'm concocting "differential motion" between the HAM3 and HAM2 platforms by coherently subtracting one platform's DOF from the other platform's corresponding DOF. Since the data is recorded and synchronized by the CDS system, one simply needs to download the two platform's data over the same time period and subtract one time series from the other and it's a "differential motion coherent subtraction."  

    - Of course, sensor noise is always of concern when doing differential measurements. As best I can, I use the estimates of the GS13 and CPS sensor noise from our old friend SEI_sensor_noise.m (T0900450), and I 
        (a) Assume every colocated sensor of a given type has identical noise
        (b) Scale them to the appropriate cartesian degree of freedom, assuming all sensors are incoherent, by taking the quadrature sum of the given sensor type's input matrix from 
            /ligo/svncommon/SeiSVN/seismic/HAM-ISI/Common/Basis_Change_Matrices/aLIGO_HAM_ISI_2_3.mat
        (c) Look at the results, find where the *Z* DOF is limited by sensor noise the real data, and scale every type's sensor noise in (a) by a single scalar fudge factor to match the real data
        (d) For differential sensor noise between the 2 platforms, I then multiply that DOF's sensor noise by a factor of sqrt(2).



What motivating data I'll show and why
    (I) SPI Longitudinal (the "interferometer" part of the SPI) would measure the differential distance between the HAM2 and HAM3 in X. So, to motivate the benefit of SPI L we'll compare an individual platform's X motion against the differential X, (HAM3 X - HAM2 X).

    (II) SPI Pitch (one "optical lever" part of the SPI) would primarily measure the differential Z (vertical) motion between HAM2 and HAM3 in Z. So, to motivate the benefit of SPI P we'll compare an individual platform's RY motion against the differential X, (HAM3 Z - HAM2 Z) *divided by the lever arm between the platforms, L.*

    (III) SPI Yaw (the other "optical lever" part of the SPI) would primarily measure the differntial Y (transverse) motion between HAM2 and HAM3. So, to motivate the benefit of the SPI Y, we'll compare an individual platform's RZ motion against the differential Y (HAM3 Y - HAM2 Y) *divided by the lever arm between platforms, L.*



OK, Now to the data.
For starter's I grabbed *one* 3 hours of data starting at -- last night, 2023-06-09 at 09:30 UTC (02:30a PDT, GPS 1370338218). The wind is low (< 10 mph), the microseism is around 0.1 [um/s], no earthquakes, and the IFO is locked, observing, in nominal low noise busy detecting gravitational waves. Note, that the RZ loops include Jim's new-and-improve blend filters that improve the local RZ performance by factors of 5 to 10 between 2 - 20 HZ.

LOCALX_vs_DIFFX shows the performance metric comparisons for SPI L.
    - The differential GS13 signal is about the same as the HAM3 local sensor for most of the frequency band. There's *some* areas below 0.5 Hz where the differential X GS13 would be better, but out of the nominal frequency region where the GS13 is used in loop.
    - Below 7 Hz, the differential CPS is better than the local CPS by factor ranging from 2 to 20. 
    - Below the "CPS rolloff frequency" for this DOF, 0.34 Hz, and SPI measuring this same differential motion (without being limited by its own sensor noise) would improve things over each local CPS by a factors of 2 to 5. 
    
Promising!

LOCALRY_vs_DIFFZoverL shows the performance metric comparisons for SPI P.
    - Here, we see a HUGE difference in performance between the local sensors and platform-to-platform differential sensors.
    - Assuming that the SPI optical lever has sensor noise below this level of rotation, would should be able to get a huge amount of improvement, and we'd have our pick of which sensor to use where, since both local CPS RY and GS13 RY sensors are MUCH worse than differential Z.
    - The only place where the differential motion is comparable (note -- comparable, not worse!) is in the ~10 Hz region where differential HEPI pier motion between the two platforms is, well, different.

*Very* promising!

LOCALRZ_vs_DIFFYoverL
    - Similar to the SPI P plots there's lots of frequency regions where SPI Y, informed by differential HAM3 - HAM2 Y would be better than local RZ. However, this DOF is probably the most confusing, because we know that each local table Y is limited in the 0.07 to 5 Hz region by local RX tilt (from local RX sensor noise across the ~1 [m] lever arm). So differential Y is limited by RX tilt, where differential Z is not in anyway limited by tilt. So we don't expect to get *as much* benefit out of an SPI Y, but we'd definitely still get some if the chambers are left as is. However, we also know that the ISI local RX sensor noise can be improved by installing better CPS sensors, like we've done for the HAM7 HAM8 systems. So, the story is a little longer here, but still...

*Very* promising!

Next on the to-do list:
    (1) Gather HAM3-HAM2 data at different environmental times, to see whether any of the above conclusions from this one data set change.
    (2) Compare this differential GS13 and CPS data against Sina's projections for sensor noise
    (3) Use this (and other data we gather) data to try to concoct a control strategy 
    (4) Use that control strategy to estimate the improved platform and suspension performance in various scenarios including
        (i) If we also improve the HAM-ISIs to use fine vertical CPS sensors 
        (i) If we also improve PR3's top mass sensing noise 
    (5) Present this kind of progress to the systems group
Non-image files attached to this report
Comments related to this report
jeffrey.kissel@LIGO.ORG - 15:38, Friday 09 June 2023 (70311)CSWG
A few more plots that show the sanity checks I made that went into the plots presented above:
    - HAM23_SPIMotivation_Z_CPS_ts.pdf Demonstrating that differential HAM3 Z - HAM2 Z is just the two time series subtracted, and there's no funny business going on in the time series data I used during this 3 hour time stretch.

    - HAM23_SPIMotivation_Z_GS13CPS_noise_and_cal_check.pdf Demonstrating that the calibration of the data all makes sense, as well as the projections and fudge factors of ~0.5 and 1.2 on the sensor noise are legit.

    - HAM23_SPIMotivation_Z_vs_DIFFZ_GS13.pdf showing GS13 inertial motion alone for both HAM2 and HAM3 compared to sensor noises.

    - HAM23_SPIMotivation_Z_vs_DIFFZ_CPS.pdf showing CPS ground-to-platform relative motion alone for both HAM2 and HAM3 compared to sensor noises.
Non-image files attached to this comment
jeffrey.kissel@LIGO.ORG - 15:41, Friday 09 June 2023 (70312)
The raw data for this aLOG has been downloaded and saved to 
    /ligo/svncommon/SeiSVN/seismic/Common/Data/
        2023-06-09_0930UTC_HAM23_timeseries.mat

The script to make the plots from that data lives in 
    /ligo/svncommon/SeiSVN/seismic/Common/SPI/Scripts/
        plot_spi_motivation_20230609.m
jeffrey.kissel@LIGO.ORG - 15:49, Friday 09 June 2023 (70313)
A quick screenshot to show where I got the "CPS Rolloff Frequency" for each of the blend filters

For the X, Y, and Z blend filter, which are all the "comp_250" filter, the CPS rolloff frequency is 0.34 Hz.
For the RX and RY blend filters, which are the "many_notches" filter, the CPS rolloff frequency is 0.60 Hz.
For the new RZ blend filter, called the "fc_yaw_filt_lp", the CPS rolloff frequency is at 0.34 Hz.

As a bonus, included in the screenshot is a reminder of what the CPS2CART and GS132CART matrices look like for sensor noise projection.
Images attached to this comment
brian.lantz@LIGO.ORG - 10:41, Monday 12 June 2023 (70367)

Quick comment on the Noise projection plot

SEI_sensor_noise includes the local to cartesian-basis noise correction factors (added in 2021)

see SEI log 1786, or the help the SEI_sensor_noise

For Example.
>> freq = logspace(-1,2, 1000);
>> cps_noise_1mm = SEI_sensor_noise('ADE_1mm', freq);
>> proj = SEI_sensor_noise('projections');
>> stg1_cps_x_noise = proj.bsc.stg1.cps.x * cps_noise_1mm;

jeffrey.kissel@LIGO.ORG - 13:58, Monday 12 June 2023 (70370)
Regarding the influence of CPS DIFF on these results
J. Kissel, A. Pele, J. Warner

Arnaud reminded that CPS DIFF exists -- and asks the legit question "is CPS DIFF on, confusing your results and conclusions?"
In short: Yes, (HAM3-HAM2) CPS diff is ON, and influencing platform motion between 1.5 mHz and 0.48 Hz.

I then got a kitchen download from Jim, which I now convey here backed up with plots and MEDM screen screenshots. In general, CPS DIFF is really tough to find. You can find the "overview" that starts with
    sitemap > ISI SENSCOR CONFIG > (upper right corner) Yellow Button "ISI DIFF" > CPS DIFF MTRX

This brings up the "start" of CPS DIFF -- the 2023-06-12_ISICPSDIFF.png screen, which ingests calibrated local CPS signals (prior to their corner-station sensor correction from the ITMY T240 in the biergarten), and "simply" subtracts them. One can see that for the corner station HAMs, there are only the two pairs subtracted and only in the IFO's longitudinal direction: (HAM3 - HAM2) X and (HAM4 - HAM5) Y.
In these cases, HAM3 is the "leader" and HAM2 is the "follower," and similarly, HAM4 is the leader, and HAM5 is follower.

Following the HAM3-HAM2 signal, that differential CPS signal is then fed into a single filter bank, H1:ISI-DIFF_HAM3_CPSX (see screenshot).
That filter module in use in that HAM3 bank is "better60mHz," which is a band-pass
    - "active" (magnitude greater than 10%) between 0.0015 - 0.48 Hz,  
    - "focused" (magnitude greater than 90%) 0.022 - 0.088 Hz.
    - "centered" (phase is 0 deg) on 0.034 Hz
See the response of this filter in 2023-06-12_ISICPSDIFF_HAM3-HAM2_better60mHz_Filter.png.

The output of that filter bank output is feed into a "soft limiter" that limits the signal to less than 10000 [nm] = 10 [um]. (see 2023-06-12_ISICPSDIFF_SmoothLimiter.png)
The typical counts coming out of our band-limiter is low 10s [nm] oscillating around 0 [nm], which maximum minute of the trends being at most 100-150 [nm], so *plenty* of head room. So, in short, the soft limiter it's doing anything.

The output of the soft limiter goes into the "leader" ISI's SUSINF "suspension input filter" H1:ISI-HAM3_SUSINF_X bank (see 2023-06-12_ISIHAM3_SUSINF.png), which again is the longitudinal direction of the IFO across HAM3-HAM2.

Finally, this output is summed into the *output* of the blend filters, i.e. the super sensor error signal for the X DOF's isolation filters.

2023-06-12_0930UTC_ISICPSDIFF_HAM3-HAM2_ControlSignal_3hrMinuteTrend.png shows the minute trend of the HAM3-HAM2 CPS DIFF band-limited control signal for the 3 hour stretch on 2023-06-09 09:30 UTC that I took the data in the main aLOG. 2023-06-12_0930UTC_ISICPSDIFF_HAM3-HAM2_ControlSignal_ASD.png shows the amplitude spectral density compared against CPS X DIFF = sqrt(2) * HAM "1 mm" ADE CPS X sensor noise (using the handy feature of SEI_sensor_noise Brian reminds me of above -- thanks Brian!).

This amplitude spectral density is consistent with the shape and amplitude of the (HAM3-HAM2) offline concocted ASD differential signal above 2023-04-13_0000UTC_HAM23_SPIMotivation_spiprcl_LOCALX_vs_DIFFX.pdf.
I attribute the difference in shape due to different averaging, windowing, and % overlap, and FFT parameters, so don't look too closely. This needs to be done more carefully offline, and I will eventually.

So, 
 - (HAM3-HAM2) CPS DIFF is *already* doing the same job that I describe that a future SPI L "the ifo part" connecting HAM3-HAM2 would do. 
 - Deciding which would do it *better* and/or which we should use in which frequency region is a question of which will have better sensor noise. 
 - Both should be a part of the discussion.
 - CPS DIFF does *not* play a role in any of the material / data / plots discussing SPI P and SPI Y, since HAM3-HAM2 Z (for P) and HAM3-HAM2 Y (for Y) do not have any CPS DIFF.
Note, the plan to improve the "the HAM2 HAM3 CPS" won't impact this assessment; at the moment, we're only considering upgrading the *vertical* CPS sensors on the HAMs.
Images attached to this comment
H1 SEI
jim.warner@LIGO.ORG - posted 20:48, Thursday 08 June 2023 - last comment - 16:12, Monday 12 June 2023(70293)
IFO is less robust against earthquakes now than before power up

This has been kind of hard to pick out, but it definitely seems like the IFO is less robust now against earthquakes that it was before increasing power over 60W in the IMC. Basically since then, we haven't been able to stay in NLN for any earthquakes over ~.5um/s, as measured by the peakmon eq witness channel.

Attached plot shows peakmon vs lock state trends since Feb 10 this year. The blue trace is the peakmon ground velocity minute trend, each green point indicates where the IFO was still locked 2 minutes after a local maximum ground velocity (found using the matlab peakfinder routine with some prominence and time separation requirements). The two marked points indicate where IMC power was increased above 60W (X=79730 minutes after Feb 10th) and the start of the run (X=148255 minutes after Feb10). Before power up we had multiple locks survive multipe 500nm/s eqs, a few around 1micron/s and one at almost 3micron/s. After the power up, the IFO doesn't ride out any eqs over 500nm/s and we basically not survived any notable eqs since the start of the run.

This is further reinforced by TJs alog from earlier today, when SEI_CS transitioning knocked us out of OBSERVE. Unless SEI_CS got dropped off the exclude recently, I suspect we never noticed because we were losing lock before the seismic system switched.

There have been no changes to the SEI eq controls. I looked at the small eq Camilla noted this morning and didn't see anything suspicious in the seismic systems, but I'll keep digging.

Images attached to this report
Comments related to this report
jim.warner@LIGO.ORG - 09:46, Friday 09 June 2023 (70301)

I will also add that this ~.5micron/s eq-band velocities are a level that the primary microseism can hit for a week or two at a time during the winter. Conditions that were already challenging for us in prior runs.

evan.hall@LIGO.ORG - 12:34, Monday 12 June 2023 (70369)ISC

Another possible culprit from around the time of April 7: removing 12 dB of low-frequency (< 1 Hz) gain from the Michelson loop to try to reduce the amount of sensor noise reinjection in the GW band (LHO:68432).

It would be a relatively simple test to (1) increase the EPICS gain of the loop by 3 dB to place the UGF back around 10 Hz, and then (2) re-engage the 4:1 Hz boost (LSC-MICH2 FM3). If the noise increase in DARM is acceptably low, perhaps you could run like this for a week to see if the duty cycle improves.

brian.lantz@LIGO.ORG - 13:28, Monday 12 June 2023 (70373)ISC

If this extra gain helps during EQs, it could also be made part of the EQ guardian response.

brina.martinez@LIGO.ORG - 16:12, Monday 12 June 2023 (70383)

Brina, Sheila,

We ran some excitations while locked, need to review plots (will come back to alog to update info)

Images attached to this comment
H1 ISC
elenna.capote@LIGO.ORG - posted 17:05, Wednesday 31 May 2023 - last comment - 14:34, Monday 12 June 2023(70055)
Power Trends 60W and 76W

I took some recent times at 60W and 76W and made some power trend plots of the first three hours of the lock. The 60W time is from a long lock around March 29th, and the 76W time is from a long lock around April 29th. Unfortunately the time for the April 29th lock we had the POP beam diverter closed, so we are missing the sideband trend during thermalization.

Images attached to this report
Comments related to this report
elenna.capote@LIGO.ORG - 17:46, Wednesday 31 May 2023 (70059)

I found a shorter lock at 76W on April 20th where the POP beam diverter was open. Trends attached.

Images attached to this comment
elenna.capote@LIGO.ORG - 14:34, Monday 12 June 2023 (70377)

I have attached another set up plots, this time adding in a 60W lock trend from early January.

One major effect we have considered when looking at these plots is the trend of the 9 MHz sideband as the IFO thermalizes. If you look at the first plot in both the main alog and the two comments, the bottom right corner has two plots showing the POPAIR RF18 and RF90 trends, effectively the 9 and 45 MHz buildups. When we lose our 9 MHz sideband, PRCL becomes unstable. Currently, the thermalization guardian works to correct exactly this, by increasing the PRCL digital gain to maintain a ~30 Hz UGF. We have mainly seen this as an issue with operating at 75 W. However, these power trends are showing us that the 9 MHz loss is present at 60W too, and Evan and Dan held the IFO at 25W a few months ago and demonstrated that this loss occurs even at low power.

The new plot I have added is an interesting comparison. On the POPAIR RF18 plot, you see that the blue trace- 76W lock from April 20, shows that we power up and then lose significant 9 MHz power. The red trace shows something similar from Jan 6 in a 60W lock. We also see this loss in a March 60W lock. I included the red trace to compare with the green trace because in the green trace we stopped at 25W for long enough to lose some 9 MHz, and then continued up in power. The green trace is also after we have improved the mode matching with new ring heater settings. It appears that build-up wise, our current situation is very similar to where we were in January.

However, this is further proof that we see 9 MHz loss no matter which operating power. I will look for more locks to compare and see if the difference between the red and green traces at 60W is a result of the TCS change. One thing to note in particular is that the ring heater changes reduces the build ups, so from January in red to March in green, we reduced the power recycling gain at 60W.

Images attached to this comment
H1 PEM (DetChar)
robert.schofield@LIGO.ORG - posted 20:53, Friday 19 May 2023 - last comment - 10:34, Monday 12 June 2023(69766)
Aborted HVAC experiments, site-wide HVAC shutdown increases range by 10 Mpc

I didn’t get very far in the HVAC experiments because the EY chiller water pumps did not recover from the site-wide shutdown until I went to the chiller pad and reset them. The time lag and hot day meant that I had to wait a few hours for recovery (fortunately I reset it quickly enough that we didnt loose lock). While I was waiting for EY temperature recovery, SF-6 (lab area cold-deck) went off on its own and Richard brought Ken in to work on it - he says one of the wires connected to the breaker was burned through. Ken just got it fixed and we are both headed out.

I did learn a couple of things in the abbreviated experiments:

1) both the chilled water turbulence and the turbine plenum turbulence are contributing to the vibration background at 4 Hz at EX

2) side-wide shutdown of turbines, associated chillers, and water pumps increased the range from about 128 to about 138 Mpc

Since I couldn't complete the experiments, I tried just turning the turbine flows down to pre-pandemic levels. I was unable to do this for the CS and EX HVACs - to me it seemed like vane actuator slippage, like we have seen in the past. EY AHU-1 worked fine for me and I turned the flow down from 12k to 9k CFM as agreed with Bubba. Otherwise I have left everything the same. I did not get a chance to toggle the lead chiller at EX.

EX HVAC experiments all times May 19 UTC:

16:21:51 EX chiller un-enabled, AHU manually disabled

16:32:58 CHWP-2 disable

16:39:38 All systems back on

17:08:36 Manual chiller 2 enabled uncheck, AHU-2 Manual Disable checked  

17:11:56 Chiller still on start so uinchecked chiller system enable

17:21:22 checked manual pump disable

17:35:30 system restored: AHU-2 disable unchecked, Chiller system ehable checked

 

18:43 AHU manual disable checked, Chiller system enable unchecked

~18:55 system restored

 

Site-wide HVAC off:

20:16:05 start of site off

20:23:32 back on

Comments related to this report
elenna.capote@LIGO.ORG - 10:34, Monday 12 June 2023 (70366)ISC

This plot is a bit out of date, but here is a DARM comparison for the time when the site HVAC was off. The range improvement from this HVAC shutoff that gained us about 10 Mpc appears to be a reduction in noise from 100-200 Hz in DARM. I think that region is mostly limited by jitter noise.

Images attached to this comment
Displaying reports 19361-19380 of 87654.Go to page Start 965 966 967 968 969 970 971 972 973 End