Displaying reports 19541-19560 of 87662.Go to page Start 974 975 976 977 978 979 980 981 982 End
Reports until 16:16, Tuesday 06 June 2023
H1 SEI
jim.warner@LIGO.ORG - posted 16:16, Tuesday 06 June 2023 (70201)
HAM8 feedthru protection partially done

I had a brief window to start installing feedthru protection on HAM8. Only got 2 of the 5 feedthrus. These are the 12" rings that go on the outside of the adapter plate, because the 12" adapters we got for this chamber don't have enough space around the 4.5" flanges to use the smaller feedthru protection. I didn't any pictures this time.

H1 SUS (AOS, ISC, OpsInfo)
jeffrey.kissel@LIGO.ORG - posted 16:10, Tuesday 06 June 2023 (70197)
Measured Updates to PR3 Sliders, M3 OSEMs, and Optical Lever P and Y Using ~4km Lever Arm to ETMX ACB Baffle PDs
J. Driggers, J. Kissel, J. Oberling, T. Shaffer

Executive Summary: We have used the ~4km arm length as a lever arm across the ~40 cm separation between ETMX ACB Baffle PDs to calibrate pitch and yaw of PR3's optic as reported by the PR3 M1 alignment sliders, M3 OSEMs, and Optical Lever pitch and yaw calibrations. They we *all* inconsistent. M1 Slider calibration changes by a factor of ~2, M3 OSEMs calibration changes by ~4, and optical lever calibration changes by a factor of ~8. We indicate the suggested correction to the calibration in the table below.

We've not installed any changes, yet. We're waiting for folks to absorb and review this content, and to get ready for the change.

Method (detailed blow-by-blow in 2023-06-06_OpticalLeverAlignmentCalibration.txt):
    (1) After the lock loss this morning, we went straight into using the INIT_ALIGN guardian to lock the X arm on read, and run the INPUT_ALIGN state. With PRM misaligned, this ensures that the PSL input beam is well aligned to the X ARM using POP WFS, and steers IM4 and PR2. We also checked and confirmed that the X ARM beam was well-centered the transmon QPDs. For us, the whole purpose of this was to make sure the PSL beam was steering through the center of the hole in the ETMX arm cavity baffle.
    (2) Took the INIT_ALIGN guardian to DOWN, and misaligned ITMX using the SUS-ITMX guardian. This then sets up a straight-shot, with no cavities, from PR3 to ETMX.
    (3) Unsure if we needed it, we also cranked up the PSL input power to 20 W.
    (4) We then slow rastered around the PR3 alignment sliders, looking for light to cross the ETMX Baffle PDs. (We confirmed PD1 and PD4 were alive by trending H1:AOS-ETMX_BAFFLEPD_1_NORMALIZED and H1:AOS-ETMX_BAFFLEPD_4_NORMALIZED, and saw that PD1 is typically saturated during nominal low noise around ~830 [ct], and PD4 is close, but still happily reading out real scattered light at ~550+/-50 [ct]. So, not knowing any better, we left them with a transimpedance of 2000 [ohm], and a whitening gain of +20 dB).
    (5) Finding that PSL light on both PD1 and PD4 by steering the PR3 M1 OPTICALIGN alignment sliders a mere (and symmetric!) +15 ["urad"] in pitch and yaw (PD1 in -PIT,-YAW, and PD4 in +PIT,+YAW), we record the pitch and yaw values of
        (a) the sliders,
        (b) the optical lever
        (c) the M3 OSEMs
    See attached trend of each of these things during those times.
    (6) Using these reported ["urad"] values, and comparing them against the physical [urad] from the center of the baffle's hole as determined by mechanical drawings of the PD separation and computing the distance from PR3 to the ETMX ACB  as 4018.7135 [m] (see details in LHO:70177), we compute a correction to the calibration each of the sensors and actuators in order to reference against this highly precise (and quite accurate) angular reference.

Results:

POSITION:
                 From LHO:70177      Slider     Oplev       M3 OSEM      Time At 
                 [urad]              ["urad"]   ["urad"]    ["urad"]     Location
Centered PIT        0.0              -117.7     +0.450      -482.992     Jun 06 2023 17:05:47 UTC
         YAW        0.0              +153.5     -1.355      +171.577

PD1      PIT      -40.1              -134.0     -4.85       -493.754     Jun 06 2023 17:00:14 UTC
         YAW      -37.2              +137.1     -5.61       +161.257
         
PD4      PIT      +34.2              -102.7     +5.12       -474.888     Jun 06 2023 16:45:00 UTC 
         YAW      +37.2              +168.4     +1.52       +180.750
         
-----------------------------------------------------------------------
DISPLACEMENT

(PD1 - Cent) PIT  -40.1              -16.3      -5.3        -10.762
             YAW  -37.2              -16.4      -4.255      -10.320
             
(PD4 - Cent) PIT  +34.2              +15.0      +4.67       +8.10
             YAW  +37.2              +14.9      +2.875      +9.17
             
(PD4 - PD1)  PIT  +74.3              +31.3      +9.97       +18.87
             YAW  +74.4              +31.3      +7.13       +19.493
            
----------------------------------------------------------------------- 
CALIBRATION CORRECTION VALUE
                                   
(PD1 - Cent)
[urad/"urad"] PIT                    2.4601     7.5660      3.7261
              YAW                    2.2683     8.7427      3.6047
 
(PD4 - Cent)                         
[urad/"urad"] PIT                    2.2800     7.3233      4.2222 
              YAW                    2.4966    12.9391      4.0567

(PD4 - PD1)                   
[urad/"urad"] PIT                    2.3738     7.4524      3.9375
              YAW                    2.3770    10.4348      3.8168
             
-----------------------------------------------------------------------             
CORRECTED CALIBRATION VALUE

Suggested Update
to Slider             
Calibration        [(DAC ct)/"urad"]  * ["urad"/urad]  =  ([DAC ct)/urad]
    PIT                2.675          * (1/2.3738)     =    1.1269        H1:SUS-PR3_M1_OPTICALIGN_P_GAIN
    YAW               12.272          * (1/2.3770)     =    5.1628        H1:SUS-PR3_M1_OPTICALIGN_Y_GAIN

Suggested Update
to Optical Lever
Calibration        ["urad"/(ADC ct)]  * [urad/"urad"]  =  [urad/(ADC ct)]
    PIT                26.9           *   7.4524       =    200.47        H1:SUS-PR3_M3_OPLEV_PIT_GAIN
    YAW                29.6           *  10.4348       =    308.87        H1:SUS-PR3_M3_OPLEV_YAW_GAIN



Discussion:
    (I) The slider vs. optical lever calibration correction is consistent with Sheila's suspicion that "the optical lever calibration is off by a factor of 4, based on the sliders" from LHO:70008.

    (II) We think the numbers derived from the the displacement between PD4 and PD1 are the most accurate numbers, so we suggest updating the sensor / actuator calibrations with these numbers (rather than the PD4-center, or PD1-center numbers). We're also confused / suspicious of the optical lever calibration correction values, given that they range from 6 to 12, where all other correction values are relatively consistent to within ~10%. We think this may be that the PR3 optical lever beam spot is close to the edge of the QPD.

    (III) We note that we're very suspicious of the YAW calibration correction factors for the optical levers. We think the PIT optical lever signal is very cross-coupled when driving YAW sliders, as much as ~0.5-1.0 PIT Oplev [urad] / YAW Slider [urad] (already correcting each by their respective calibration correction values list above). YAW optical lever per PIT slider is much less, around 0.04 YAW Oplev [urad] / PIT Slider [urad]. 

Reasons we brainstormed for this kind of cross coupling,
        (i) The QPD itself is clocked with respect to the beam spot's vertical / horizontal motion at the QPD
        (ii) The beam spot on PR3 is not centered
        (iii) The beam spot at the QPD has some astigmatism

As a result of (II) and (III), Jason thinks it's worth it to look at the PR3 optical lever QPD in its housing on top of HAM3 on some future Tuesday.

    (IV) For the M3 OSEMS, there's no convenient place to re-calibrate *just* pitch and yaw, since the calibration of the OSEMs are done in the OSEM basis.
However, there's the as-of-yet-unused "SENSALIGN" matrix in between the output of the OSEM2EUL basis change matrix and the H1:SUS-PR3_M3_WIT_P_DQ and H1:SUS-PR3_M3_WIT_P_DQ read-backs. So, we can replace the P and Y diagonal elements, which are currently and forever-have-been 1.0, with the CALIBRATION CORRECTION VALUES from the above table, 3.9375 for PIT and 3.8168 for YAW, 
    caput H1:SUS-PR3_M3_SENSALIGN_2_2 3.9375
    caput H1:SUS-PR3_M3_SENSALIGN_3_3 3.8168

Images attached to this report
Non-image files attached to this report
H1 General
ryan.crouch@LIGO.ORG - posted 16:01, Tuesday 06 June 2023 (70199)
OPS Tuesday Eve shift start

TITLE: 06/06 Eve Shift: 23:00-07:00 UTC (16:00-00:00 PST), all times posted in UTC
STATE of H1: Preventive Maintenance
CURRENT ENVIRONMENT:
    SEI_ENV state: CALM
    Wind: 10mph Gusts, 5mph 5min avg
    Primary useism: 0.05 μm/s
    Secondary useism: 0.12 μm/s
QUICK SUMMARY:

Taking over from TJ

LHO General
thomas.shaffer@LIGO.ORG - posted 16:01, Tuesday 06 June 2023 (70176)
Ops Day Shift Summary

TITLE: 06/06 Day Shift: 15:00-23:00 UTC (08:00-16:00 PST), all times posted in UTC
STATE of H1: Preventive Maintenance
SHIFT SUMMARY: Maintenance day. During maintenance there was a temperature excursion in the LVEA and end stations moving temperatures by just over a degree F (alog70194). This was enough for our alignment to be too far off to lock. The main symptoms were ALS COMM beatnotes very low and ALS Y not able to lock or get decent flashes, and the ALS camera images more clipped than usual. Moving PR3 would be temporarily helpful, but as the temperatures were moving back, the alignment would change again. Temps returned a few hours ago, but the suspensions aren't back yet. PR3 Yaw started the day at 153.5, it is now at 154.6 but we have made it past DC readout and are powering up.

At the next lock loss, it would probably be good to see if moving PR3 back in the direction of the 153.5 would be beneficial as the suspensions get back to their previous positions. Go to a green arms locking state and if cameras look clipped, buildups are poor even though alignment seems as best you can get, and beatnotes are bad (assuming you can get the arms locked), then move PR3 and see if these issues improve.
LOG:

Start Time System Name Location Lazer_Haz Task Time End
13:21 CDS Erik Remote n Rebooting work stations 13:21
14:17 COMM Camilla CR n PRCL OLG Measurement 14:27
14:31 PEM PEM_MAG_INJ GRD Auto n Automatic magnetic injections 14:46
14:46 SUS SUS_CHARGE GRD Auto n Automatic in-lock charge measurements 15:01
15:00 FAC Karen EY n Technical Cleaning 16:31
15:02 SUS Kim EX n Technical Cleaning 16:25
15:05 SEI Jim, Randy EY n HEPI skid hole drilling 16:49
15:08 VAC Jordan LVEA n Turbo pump checks 19:08
15:14 OpLev Jeff, Jason CR n PR3, SR3 oplev calibration 18:58
15:16 FAC Cindi FCES n Tech clean 16:23
15:16 VAC Gerardo LVEA n LY rack door install 16:38
15:26 FAC Chris, pest control LVEA, outbuilds n Pest sweeps 17:56
16:09 VAC Janos EX n Dewar jacket pumping ongoing
16:09 VAC Janos LEVA n Check on turbos 18:09
16:10 FAC Tyler, Johnston co OSB n Fire alarm testing 16:27
16:13 - Betsy, guest LVEA n Tour 16:54
16:16 SEI Jim FCES n HAM8 feed through protection 18:10
16:32 FAC Kim, Cindi, Karen LVEA n Tech clean 18:32
16:40 VAC Richard LVEA n Regulator hunt 18:33
16:46 SQZ Vicky LVEA - Ebay LOCAL SQZ table alignment in local hazard 18:38
16:51 FAC Tyler, Fire marshal, Johnston co EY, EX n Fire system testing 18:51
17:02 SEI Jim, Fil, Randy, Patrick EX n HEPI beckhoff 18:44
17:09 CDS Jonathan MSR n Cold spare router addition to rack 19:09
18:11 EPO Cassidy LVEA n Gate valve pictures 18:53
18:21 - Eadie Yarm n Run 18:58
18:34 FAC Ken OSB to LSB n Move lift 18:50
H1 ISC (OpsInfo)
thomas.shaffer@LIGO.ORG - posted 15:02, Tuesday 06 June 2023 (70193)
How to lock an SRX

This should be an incredibly rare configuration that we would need, but worth noting how we did it. Jeff and Jason needed a locked SRX (not our usual SRY). This has the following suspenions aligned:

'SRX':{'ETMY':'MISALIGNED',
                'ITMY':'MISALIGNED',
                'ETMX':'MISALIGNED',
                'ITMX':'ALIGNED',
                'PR2':'ALIGNED',
                'SR2':'ALIGNED',
                'PRM':'MISALIGNED',
                'SRM':'ALIGNED'},

We ended up making 3 edits in the ALIGN_IFO guardian to change SRY locking to SRX (names obviously inconsistent). The changes were made with trial and error and Jenne's intuition. Changes in bold:

H1 CAL (CAL)
richard.savage@LIGO.ORG - posted 14:05, Tuesday 06 June 2023 (70192)
H1 Pcal X/Y calibration comparison

Following the "by hand" calculation method described in this aLog entry, the X/Y Pcal calibration comparison factor from the 9 hour locked stretch starting at 22:00 UTC on June 5, 2023 is 0.99967 using 10 averages (1024 sec with 50% overlap).

With the same settings and start time, but 60 everages, the calculated X/Y comparison factor is 0.99972

Ideally, it would be unity.  This result indicates that it is within 0.03 % of the expected value.

H1 General
jason.oberling@LIGO.ORG - posted 14:02, Tuesday 06 June 2023 - last comment - 14:31, Tuesday 06 June 2023(70194)
L/VEA Temperature Excursion

Logging a temperature excursion in the LVEA and the EX/EY VEAs during maintenance today, see attached plots.  This was caused by fire alarm testing shutting off the input air to the HVACs (as designed).  For some reason, the input air did not come back on upon cessation of fire alarm testing (maybe it needs to be done manually? Question for FAC).  Things are back on and temps are returning to normal.

Images attached to this report
Comments related to this report
thomas.shaffer@LIGO.ORG - 14:31, Tuesday 06 June 2023 (70196)

I've had to move PR3 in Y to get any sensible COMM beatnote and okay ALSY power. After I ran initial alignment I wasn't able to get ALS Y to lock at all and flashes wouldn't get above 0.8. Looking at the T1,2,3 M1 OSEMs, the PR3 oplev, and PY inmon channels we can see that it's definitely moved with the temperature. The T1,2,3 osem channel show the sag of this suspension from the hotter LVEA temp, and the delay that this has. Even though the LVEA temps have turned around, the suspension didn't stop sagging for just under two hours after that change. Assuming the zone 5 temperature levels off in the same place as it was (67.0F), we should be back to a similar place around 4pm local time. At this point we might want to try to bring PR3 Y back to 153.5 as I found it today.

Images attached to this comment
H1 SQZ
victoriaa.xu@LIGO.ORG - posted 13:57, Tuesday 06 June 2023 - last comment - 10:39, Thursday 15 June 2023(70190)
Likely resolved pump ISS issues with on-table alignments; pump AOM was significantly clipped

I think the recent issues with squeezer pump ISS railing are likely resolved after today's on-table realignments. The green pump AOM was significantly clipping the beam (SQZT0 layout here, "GAOM1"), both reducing the total power after the AOM, and degrading the fiber coupling efficiency due to the clipped+bad mode shape. See GAOM1 sweeps from this morning (before aligning, left) and now (after, right). Along the pump path, we now have better GAOM1 throughput (~90%), comparable diffraction efficiency (~60%), and improved fiber coupling. For 60uW opo trans we've been using, we previously launched 22mW with no buffer (hence iss railed); now we only have to launch 15mW for the same opo transmitted power, with lots of buffers.

GAOM1 typically has ~90% throughput, e.g. previously this was 14.4mW out from 16mW incident. Today I first measured 25mW out for 44mW incident (~57%): this means >30% of power from SHG was clipping on the AOM apeture. After re-aligning GAOM1 using the mount screws, we're back up to 40mW out for 45mW incident, so almost 90% throughput again. I think this could be better, but good enough for now.

Relieving the clipping also significantly improved fiber coupling efficiency, presumably b/c it improves the mode shape, as we are using the 0-th order AOM mode for pump light, and not the nice diffracted order that gets cleaned up in the diffraction. So aom clipping shows up on the beam we are trying to fiber couple.
-- Before, for 20mW into the pump fiber, we had 1.8mW on OPO_REFL_DC_POWER on the other end, with GAOM1 driven at 2-3V (almost no room), and all power on that path going into the fiber (SHG_REJECTED = 0mW).
-- After, for 20mW into the pump fiber, we have 2.9mW on OPO_REFL_DC_POWER (60% higher power), with GAOM1 driven at 4.5V (mid-range), and a healthy buffer of rejected power on the fiber path (SHG_REJECTED = 8mW).

Images attached to this report
Comments related to this report
victoriaa.xu@LIGO.ORG - 14:11, Tuesday 06 June 2023 (70195)

I've upped the generated sqz levels, back to more "normal", hopefully nominal, values. In $(userapps)/sqz/h1/guardian/sqzparams.py, Line 12, I've set opo_grTrans_setpoint_uW = 85, and re-tuned the OPO co-resonance temperature at this pump power (temp decreased from 31.7C to 31.68C, expected as the higher power heats the opo crystal more).

This OPO green trans setpoint of 85 uW corresponds to a generated SQZ level of about 15 dB, or non-linear gain of 12.3. By comparison, 60uW ~ Gen SQZ = 12dB ~ NLG 6.4. So, this is nearly doubling the squeezer gain, aka increasing the generated squeeze level by about 3dB.

victoriaa.xu@LIGO.ORG - 15:39, Tuesday 06 June 2023 (70198)

To check whether pump ISS failures are from aom clipping in the future, we can try the following. SQZT0 medm stuff should look like this screenshot, with teal circle highlighting the path we're talking about, and red arrows showing some knobs to turn.
1) Bring SQZ_OPO_LR guardian "DOWN". Now PUMP_ISS is disabled, so GAOM1 box is yellow.
3) Turn off pump fiber flipper.
2) Set H1:SQZ-OPO_ISS_DRIVEPOINT = 0. This turns off GAOM1 diffraction, and sends all power to the fiber (pump light uses 0-order).
3) See the total pump power after GAOM1 (sum of H1:SQZ-SHG_REJECTED_DC_POWERMON + H1:SQZ-SHG_LAUNCH_DC_POWERMON). 
4) If GAOM1 is well-aligned and not clipping badly, I'd expect total power after GAOM1 to be about 70% of the SHG output green power, H1:SQZ-SHG_GR_DC_POWERMON.

Broken down, this ratio is from SHG's green output light (H1:SQZ-SHG_GR_DC_POWERMON) being split ~25% to FC green locking, and the remaining ~75% to the pump path GAOM1 which lets through ~90%.

I'm a bit suspious how this happened in this first place: I wonder if the beam is slightly large for the AOM aperture (but aom's throughput is not terrible), whether SHG or lab temperature drifts are changing the output alignment or mode-shape slightly, or whether we've bumped the SHG output path doing other on-table work. If ISS railing becomes a problem again at this SHG power, we can look into it more. For reference, we last increased SHG power by ~15% on May 16th (69671) in an attempt to resolve exactly this issue; we don't need all this shg power anymore.

Images attached to this comment
victoriaa.xu@LIGO.ORG - 23:32, Wednesday 07 June 2023 (70266)

Attaching quick SHG, OPO, CLF transfer functions taken after table alignments, with pd powers on medm.

Images attached to this comment
victoriaa.xu@LIGO.ORG - 10:39, Thursday 15 June 2023 (70483)

Just following up on trends since this on-table AOM alignment -- this on-table fix seems to have mostly resolved the previous squeezer pump ISS issues.

Images attached to this comment
H1 SEI
jim.warner@LIGO.ORG - posted 13:42, Tuesday 06 June 2023 (70191)
End station HEPI work today

Both end hepi pump stations were taken down today. At EY, this was done so Randy could drill and mount unistrut brackets for the future install of a Beckhoff rack. At EX, Randy also drilled and tapped, but mostly we wanted to rig up and test adding the reservoir float switch to the Beckhoff, which kind of worked, but it doesn't tell us anything more than the already available channels. The relay reads 24V while the pump station is running, but that 24v comes from the VFD power supply and gets switched off when the VFD trips, regardless of the cause. We would have to re-engineer the float switch configuration in order to get a signal that would indicate the pump station tripped on the float switch, so I don't think we will pursue that readback for now.

H1 General
thomas.shaffer@LIGO.ORG - posted 12:37, Tuesday 06 June 2023 (70188)
LVEA Swept

Vicky swept the LVEA today following the usual list. No unsual items were noted. I've turned off the WAPs at all buildings.

H1 PEM (OpsInfo)
thomas.shaffer@LIGO.ORG - posted 11:49, Tuesday 06 June 2023 (70186)
EX dust monitor vacuum pump found inoperable

Jim and Randy found the EX dust monitor vacuum pump inoperable. We will replace this with the spare in the near future.

LHO VE
david.barker@LIGO.ORG - posted 10:10, Tuesday 06 June 2023 (70183)
Tue CP1 Fill

Tue Jun 06 10:06:34 2023 INFO: Fill completed in 6min 34secs

Gerardo confirmed a good fill curbside.

Images attached to this report
H1 General
ezekiel.dohmen@LIGO.ORG - posted 09:11, Tuesday 06 June 2023 - last comment - 08:53, Friday 09 June 2023(70179)
Filter Stage Enable Mismatch
There are a number of models with filters in modules that have been engaged but no filter has been defined for that stage. This causes some confusion when scanning for unresponsive filter stages, as these will clutter the results. 
Attached is an example of what this looks like on the medm screen. FM2 is enabled, but nothing is loaded in that stage so the 2nd box never turns green. 

My guess is that these stages used to have a filter defined for them, but were removed. The solution is to finish the removal of these stages, buy disabling the stage and saving the new state with SDF. 

Full listing of filters/stages that are enabled but don't have the enabled stage defined in the filter file. 

h1susetmy : [('SUS-ETMY_L2_DAMP_MODE19', 'FM1'), ('SUS-ETMY_L2_DAMP_MODE9', 'FM4')],

h1sussqzin : [('SUS-ZM1_M1_WD_OSEMAC_RMSLP_LL', 'FM6'), ('SUS-ZM2_M1_LOCK_L', 'FM6')]

h1hpietmx : [('HPI-ETMX_3DL4CINF_C_Z', 'FM1'), ('HPI-ETMX_3DL4CINF_C_Y', 'FM1'), ('HPI-ETMX_3DL4CINF_C_X', 'FM1'), ('HPI-ETMX_3DL4CINF_B_Z', 'FM1'), ('HPI-ETMX_3DL4CINF_B_Y', 'FM1'), ('HPI-ETMX_3DL4CINF_B_X', 'FM1'), ('HPI-ETMX_3DL4CINF_A_Z', 'FM1'), ('HPI-ETMX_3DL4CINF_A_Y', 'FM1'), ('HPI-ETMX_3DL4CINF_A_X', 'FM1')]

h1lsc : [('LSC-EXTRA_AI_2', 'FM2')]

h1lscaux : [('LSC-LOCKIN_1_DEMOD_9_I', 'FM1'), ('LSC-LOCKIN_1_DEMOD_9_Q', 'FM1')]

h1oaf : [('OAF-CAL_SUM_DARM_L1', 'FM3'), ('OAF-CAL_SUM_DARM_L1', 'FM6'), ('OAF-CAL_SUM_DARM_L3', 'FM3')]

h1calcs : [('CAL-CS_DARM_ANALOG_ETMY_L1', 'FM4')]

h1susproc : [('SUS-ETMY_L2_DAMP_MODE19_BL', 'FM1'), ('SUS-ITMY_L2_DAMP_MODE18_BL', 'FM1'), ('SUS-ITMY_L2_DAMP_MODE19_BL', 'FM1')]

Edited to remove any filter stages under local control. 
Images attached to this report
Comments related to this report
daniel.sigg@LIGO.ORG - 10:16, Tuesday 06 June 2023 (70184)

Some filters have front-end control over which filters stages are on. Typically, more than one filter stage is used for, say a automatic boost, but only a subset is actually loaded. So, a filter may be on, but empty. This is the expected behaviour. Changing which filter stages are participating would be a front-end model change.

A better solution may be to turn the 2nd box on for empty filters, when they are on.

jeffrey.kissel@LIGO.ORG - 12:16, Wednesday 07 June 2023 (70239)OpsInfo, SUS
After reviewing all the "SUS" filter banks mentioned above, these empty filter banks are either on because they were turned on by mistake (the ZM1 and ZM2 filters) and blindly accepted into SDF, or the bank had never been active use for control or monitoring (the violin MODE control and monitoring filters), so someone was probably playing around with a filter design and cleared it out but forgot to turn off the filter. 

In all SUS cases, the filter module should be turned off and accepted as such in SDF.

We'll make a point to clean this up and clear out the confusion next Tuesday, or during a next convenient lock loss.
jeffrey.kissel@LIGO.ORG - 15:14, Wednesday 07 June 2023 (70247)CDS, SQZ
h1sussqzin ZM1 and ZM2 filters in question have been turned off -- see LHO:70245.
jeffrey.kissel@LIGO.ORG - 15:48, Wednesday 07 June 2023 (70252)CDS, SEI
h1hpietmx filters in question have been turned off -- see LHO:70251.
jeffrey.kissel@LIGO.ORG - 16:04, Wednesday 07 June 2023 (70256)CAL, CDS
The h1oaf and h1calcs filters in question have been turned OFF -- see LHO:70255.
jeffrey.kissel@LIGO.ORG - 08:26, Friday 09 June 2023 (70299)CDS, SUS
The h1susetmy and h1susproc filter modules in question have been addressed -- see LHO:70264.
brian.lantz@LIGO.ORG - 08:53, Friday 09 June 2023 (70300)

To Daniel's point - Another choice is to populate the filter with a gain=1 stage. Then it turns on, but doesn't do anything. SEI does this with some of the calibrations. e.g.  FM1 is the the manufacture's calibration, and FM2 is to tweak the calibration based on measurements. If the sensor is very close to spec, FM2 can just be a gain=1. Then all the automation works more smoothly.

LHO VE (CDS, SEI, VE)
janos.csizmazia@LIGO.ORG - posted 08:38, Tuesday 06 June 2023 - last comment - 11:47, Wednesday 07 June 2023(70178)
CP8 (EX) dewar jacket pumping
I have started pumping exactly at 8:31:00.
Comments related to this report
janos.csizmazia@LIGO.ORG - 09:06, Tuesday 06 June 2023 (70180)
Here is the stackup. The pressure was 27 microns at the start of the pumping.
Images attached to this comment
janos.csizmazia@LIGO.ORG - 13:00, Tuesday 06 June 2023 (70189)
As we've spoken with Robert, I have generated some noise at EX, then switched the pump on/off a few times. The specifics:
Stomping (I used a steel bar, you should see a ~2 Hz noise):
- Start: 12:44:00
- Stop: 12:44:10
- Start: 12:44:40
- Stop: 12:44:50

Pump on/off sequences:
- Off: 12:46:00
- On: 12:47:00
- Off: 12:48:00
- On: 12:49:00
- Off: 12:50:00
- On: 12:51:00

The pump is now running, the pressure was 14 micron (which means, that if we could run it until Thursday, that would be sufficient - if there'll be a lock-loss, I will switch the pump off).
janos.csizmazia@LIGO.ORG - 16:33, Tuesday 06 June 2023 (70204)
The pumping was finished at 16:23, as the data analysis haven't been finished yet.
robert.schofield@LIGO.ORG - 09:48, Wednesday 07 June 2023 (70225)

I had a look at EX accelerometers and, while I see the pounding noise, I do not see the pump turn on and off. The accelerometers are more sensitive than DARM to vibration, so I think that it is fine to pump with this pump isolation setup while we are in observing mode.

jeffrey.kissel@LIGO.ORG - 11:47, Wednesday 07 June 2023 (70237)DetChar, ISC, OpsInfo, PEM, SYS
Tagging a few systems level groups who should me made aware Robert's conclusion that it's OK to run these pumps.
(Not resisting, indeed supporting Robert's conclusion by making sure other people see it and have a reference to point to when it's brought up by the vacuum team.)
H1 AOS
jason.oberling@LIGO.ORG - posted 08:37, Tuesday 06 June 2023 - last comment - 12:18, Tuesday 06 June 2023(70177)
Expected PR3/SR3 Pitch/Yaw to End-Station ACB PDs 1 & 4

I’ve done a rough calculation of the expected pitch/yaw from PR3/SR3 to ETMx/ETMy ACB PDs 1 and 4.  Results come out the same, only differing in direction depending on which PD we’re shooting for.  One big assumption I made: aligned PR3/SR3 points to center of ACB (not sure if this is true in practice).  This is to aid in our attempt at refining PR3/SR3 OpLev pitch/yaw calibrations after Sheila noticed discrepancies here.

Comments related to this report
jeffrey.kissel@LIGO.ORG - 12:18, Tuesday 06 June 2023 (70187)
Here's some of the details of the calculation that results in the urad of PR3 / SR3 displacement needed to move from "centered within the baffle's hole" to each baffle PD position he quotes above.

Also, just to translate "up/down" and "CW/CCW" at the ACB into PR3 Euler Drive Basis at PR3 (using the right hand rule): 
    Up = - PIT
    Down = + PIT
    CW = Clockwise = -YAW
    CCW = Counter Clockwise = +YAW 
Non-image files attached to this comment
H1 ISC
camilla.compton@LIGO.ORG - posted 04:21, Tuesday 06 June 2023 - last comment - 10:01, Tuesday 06 June 2023(70169)
OPS Owl Mid Shift Update

STATE of H1: Lock Acquisition

Lost lock at 09:37UTC, cause was 11Hz PRCL instability, see attached and Brina's 70153. this is with Jenne's updated PRCL2 gain of 1.7 70160. Note there is an issue with the lockloss tool but you can use the command line tool with 'lockloss show 1370079438' to get the ndscope plots.

Successfully did an initial alignment after couldn't lock PRMI (with moving PRM) and we lost lock at CHECK_MICH_FRINGES. Since then locking has been fine, currently at MAX_POWER.

Images attached to this report
Comments related to this report
jenne.driggers@LIGO.ORG - 10:01, Tuesday 06 June 2023 (70182)

I'm hopeful (although have not yet looked closely at the lockloss) that this was more due to the earthquake than the PRCL gain.  I note that the amplitude of the 11 Hz in this plot is ~10x lower than those in Brina's alog.  For now I've set the guardian to put the PRCL2 gain to 1.7, and we'll see if we get another nice long lock like this one was.

H1 ISC
jenne.driggers@LIGO.ORG - posted 19:13, Monday 05 June 2023 - last comment - 17:59, Tuesday 06 June 2023(70160)
Increased PRCL2 gain further

Since Brina found in alog 70153 that we have still been having locklosses due to too-low PRCL gain, I asked RyanS to take us out of Observing for a few minutes (ended up being ~10 mins) so that I could measure the PRCL open loop gain.  It looked like the PRCL gain was a bit low, compared to the latest reference from May 31st.  I increased the PRCL2 gain from 1.5 to 1.7, and saved that value in the Observe SDF. 

In the first screenshot, I show the SDF.

In the second attached screenshot, you can see the reference from May 31st ("Prev reference"), the somewhat low-ish PRCL gain "As found, 4 hrs locked", and the higher PRCL OLG after I increased the PRCL2 gain "current measurement". 

I'm hopeful that this helps us stay locked a little longer.  We may need some more spot measurements of the PRCL gain.  I have not yet made any changes to guardian, and I don't think I can switch us to the safe.snap SDF file, so I suspect that next lock, this value will come back as 1.5.  We should probably measure the PRCL OLG early in a lock, but then modify this gain wherever it was set to 1.5, to now be 1.7.  And we should figure out why it needed to be increased!

Images attached to this report
Comments related to this report
camilla.compton@LIGO.ORG - 07:37, Tuesday 06 June 2023 (70173)

Ran the template in lsc/h1/templates/PRCL/PRCL/PRCL_OLG_NOISE_FULL_LOCK_NLN.xml and saved results in camilla.compton/Documents (see attached).

This was with H1:LSC-PRCL2_GAIN at 1.7 and after 23 minutes at NLN. Cursor is on 41.5Hz, gain 1, phase 21deg. Unsure on what the references are.

Images attached to this comment
jenne.driggers@LIGO.ORG - 07:54, Tuesday 06 June 2023 (70174)

Thanks!  I think this means that we can (just barely) put into guardian to use 1.7 in the PRCL2 gain, rather than the 1.5 we'd been using.  I'll do that when I get out of my morning set of meetings.

jenne.driggers@LIGO.ORG - 09:52, Tuesday 06 June 2023 (70181)

I've just done this in the ISC_LOCK guardian, so next lock it'll automatically be set to a gain of 1.7.  I'll watch this as we come up from maintenance in a few hours.

jenne.driggers@LIGO.ORG - 17:05, Tuesday 06 June 2023 (70209)

Since we had not quite gone into Observe yet, I took a quick PRCL OLG measurement, 15 mins after we got to NomLowNoise.  The PRCL UGF is quite high at 50 Hz, shown in red in the attachment (pink is the same old reference as the red trace in Camilla's plot above).  I could see some gain peaking in the DRMI DTT on the wall, but that relaxed quite quickly, which is consistent with Camilla's plot 23 mins into a lock looking like a much more sensible loop with less gain peaking.  Since the goal UGF is around 30 Hz, a better thing to do will be to modify the thermalization guardian to increase the PRCL gain a little bit when we're first locked, but then much more than it currently is later in the lock, and put PRCL2 gain back to its nominal value of 1. 

Images attached to this comment
jenne.driggers@LIGO.ORG - 17:59, Tuesday 06 June 2023 (70211)

I think I have a candidate new 'equation' for the PRCL gain thermalization.  In the attached plot, the overall digital PRCL gain (so, PRCL1 gain times PRCL 2 gain) is plotted versus minutes, for the first 6 hours of lock that the thermalization guardian is changing things.  After the first 6 hours, it just holds whatever gain was in there.

Blue is what the thermalization guardian was set up to do, with a variable in the thermalization called GAIN_SCALE set to 3.0, and PRCL2 gain set to 1.

Orange is what we've been running with for the last several weeks, with PRCL2 gain set to 1.5. 

Green is what we've been running the last few locks, with PRCL2 gain set to 1.7.

The three circle markers are estimates of what the gain ought to be to keep the UGF at 30 Hz, from measurements that Camilla and I have taken.

The pink trace is a candidate thermalization gain equation that would replace the blue one, and we'd use with PRCL2 gain set back to 1.  For this, the only change to the thermalization guardian is that the GAIN_SCALE would be set to 5.55 (rather than the current value of 3.0), and the PRCL2 gain would be set back to 1.

I'll make this change next time the IFO is unlocked and I'm around.

Images attached to this comment
Displaying reports 19541-19560 of 87662.Go to page Start 974 975 976 977 978 979 980 981 982 End