Reports until 21:37, Monday 04 August 2014
H1 SUS
arnaud.pele@LIGO.ORG - posted 21:37, Monday 04 August 2014 (13189)
BSC3 (ITMX) tfs are clear

After BS and ITMY results, attached are itmx tfs ran over the week end, after doors closeout. During the measurement ISI was damped. Results look good. Lower stages show factor of two-ish discrepancy with model as Jeff pointed out.

1. Undamped H1 ITMX M0-M0 tfs compared with fiber model
2. Undamped H1 ITMX R0-R0 tfs compared with thincp model
3. M0 undamp R0 damp H1 ITMX L1-L1 tfs compared with fiber model
4. M0 undamp R0 damp H1 ITMX L2-L2 tfs compared with fiber model
4. H1 ITMX M0-M0 tfs compared with other ITMs
5. H1 ITMX L1-L1 tfs compared with Livingston's ITMX
6. H1 ITMX L2-L2 tfs compared with Livingston's ITMX

Data and scripts were commited to the svn

Non-image files attached to this report