Reports until 14:54, Friday 03 October 2014
H1 SUS
jeffrey.bartlett@LIGO.ORG - posted 14:54, Friday 03 October 2014 (14292)
Quad-09 Phase1b TFs
After fixing the not taking Damped TF problem and the channel list mismatch problem, we took a full set of transfer functions for 3IFO Quad-09. The results data are posted below and have been added to the SVN repository. There are a couple of anomalies in the data. 

(1). The last peak of the Damped M0 data in "Y", "R", and "L" are shifted up. 
(2). The R0 "Y" DOF appears to not be damped where as the other 5 DOFs are.  

Note: The staging building test stand hardware and software are somewhat down level to the H1 & L1 test stands.   
Non-image files attached to this report