Reports until 17:57, Monday 27 October 2014
H1 SUS
stuart.aston@LIGO.ORG - posted 17:57, Monday 27 October 2014 (14653)
ITMX & ITMY (QUAD) M0-M0 Phase 3b TFs - show rung up P & R modes
Initial attempts to take Phase 3b M0-M0 undamped TF acceptance measurements for both ITM (QUADs) this morning showed rung up P & R modes cross-coupling into other DOFs. Both ISI's were damped and FULLY_ISOLATED via Guardian. Measurements were as follows:-

- M0-M0 undamped results (2014-10-27_0800_H1SUSITMX_M0_ALL_TFs.pdf)
- M0-M0 undamped results (2014-10-27_0800_H1SUSITMY_M0_ALL_TFs.pdf)

Measurements from above have been compared with each other and the model (allquads_2014-10-27_H1SUSITMs_Doff_Phase3b_ALLM0_ZOOMED_TFs.pdf).

All data, scripts and plots have been committed to the sus svn as of this entry.

TFs will need to be repeated at the next opportunity.
Non-image files attached to this report