Reports until 19:59, Monday 30 March 2015
H1 PEM
robert.schofield@LIGO.ORG - posted 19:59, Monday 30 March 2015 - last comment - 15:02, Wednesday 08 April 2015(17574)
EY tilts twice as much as EX along the beam line, according to 4 months of seismometer data in the 0.03-0.08 Hz band

The optimal location for  a single version of Krishna’s BRS (intermediate frequency tilt sensor), or, if it would be better to have two of them, depends on the tilt spectrum in the beam direction. We suspected that wind-induced tilt is worse at EY than EX, where the BRS is currently located, because, for typical wind storm directions, the building is being pushed roughly along the beam axis at Y-End and roughly perpendicular at X-End (the tumble weeds usually roll down the Y-Arm). But we aren’t sure whether a single sensor at EY would make sense (e.g. if EY is 10x worse than EX) or if two BRSs would be better.  Since we have only the one BRS, we used the 0.03-0.08 Hz band of STS seismometers to compare the two stations. This frequency band was selected as a proxy for tilt because this band is below the microseismic peak frequency and, in windy conditions, ground motion in this band is usually dominated by tilt. Figure 1 shows the strong correlation between the 0.03-0.08 Hz seismometer band and the tilt measured by the BRS at EX for one wind storm. Each of the small points in the plots in this log represent a 60s average of the wind speed and a 60s fft of the ground motion.

Figure 2 shows 4 months (Aug 15, 2014 - Dec 15, 2014) of the 0.03 to 0.08 Hz beamline seismic band at EY and EX plotted against wind speed measured at EX.  The large red and blue dots show the median of minute points in 2 MPH bins. Dipongkar has plotted the median because large earthquakes, which also appear in this band, would bias the mean. Roughly speaking, for a particular wind speed, the signal at EY is twice the signal at EX when averaged over many storms in 4 months. This data suggests to me that we may want a second BRS at EY rather than moving the sensor from EX to EY, because the difference is, on average, only a factor of 2.

The differences between the stations can change for different wind storms, possibly because of different wind directions. Figure 3 shows the effects of individual storms (each storm is a different color, the same color on both plots) at the two stations. One of the storms produced about 5 times more beam-line tilt at EY than at EX.

Caveat: Getting this data is very time-consuming, so we are putting in this log even though we have obtained only 4 months of data. Dipongkar will continue to increase coverage to include the spring windy period and we will update if necessary.

Robert Schofield, Dipongkar Talukder

Non-image files attached to this report
Comments related to this report
robert.schofield@LIGO.ORG - 16:07, Tuesday 31 March 2015 (17588)

We were going to wait until we had a year of data before putting in corner station plots and the plots for tilt perpendicular to the beamline,  but since Krishna asked, here are the CS plots for the same storms as Fig. 3.

Non-image files attached to this comment
krishna.venkateswara@LIGO.ORG - 21:01, Monday 30 March 2015 (17575)

Thanks for the study! I know it is very time consuiming but I thought I'd say that it would also be very interesting to compare the tilt of the corner-station against the end-station during these wind-storms. If I remember right, the corner station slab moves roughly factor of 2-3 less than EX. If so, then once tilt at the end-station is corrected for (by factors of 5-10), the corner-station tilt would limit the low-frequency ISI motion.

dipongkar.talukder@LIGO.ORG - 14:41, Wednesday 08 April 2015 (17751)
Added Figure5 showing 4 months CS-X and CS-Y tilt plotted against wind speed measured at EX.
Non-image files attached to this comment
dipongkar.talukder@LIGO.ORG - 15:02, Wednesday 08 April 2015 (17752)
Added four new figures which are Figures 2,3,4 and 5 above recast with their y-axis converted from 0.03-0.08 Hz band velocity in [nm/s] into tilt [nrad] using the model from Figure1 (replotted and attached in this comment). Note that x and y in the fit equation and model of Figure1 are in the units of nm/s and nrad, respectively.
Non-image files attached to this comment