Reports until 13:41, Friday 14 April 2017
H1 SUS (CAL, CDS, DetChar, ISC, OpsInfo, SYS, VE)
jeffrey.kissel@LIGO.ORG - posted 13:41, Friday 14 April 2017 (35553)
Charge Measurement Update;
J. Kissel

I'd collected charge measurement data this past Tuesday (4/11); here's the processed data.

Conclusions:
- ETMX continues to hover around an un-impactful 10-20 [V], because we have a relative high observing duty cycle. (see attachments 1 & 2)
We shut off the ETMX ESD's bias voltage during observation, which means stray charge in the vacuum system is only attracted by the ~10-20 [V] instead of the ~400 [V] in place when we're down or acquiring lock. As long as we continue doing so, we should be fine for the foreseeable future.

- ETMY continues to accumulate charge. (see attachments 1, 2, & 3)
While we flip the sign of ~400 [V] bias of the ETMY ESD while down and during acquisition, the high observation duty-cycle means it's essentially always one sign. That means we're accumulating charge at a relatively fast rate of 5 [V/month] -- as reported by the *angular* effective bias voltage (see 3rd and 4th attachment). What *really* matters is the relative longitudinal actuation strength -- relative to when we last reset the clock (in this case January) -- and with this we're still in the greener side of the yellow zone (see 5th attachment).

As such, my recommendations from last week (LHO aLOG 35366) are now solidified: 
Just before we vent on May 8th, during last minute preparations as we bring the IFO down, let's 
    - Turn OFF the ETMX ESD bias completely, and leave it OFF 
    - Leave the ETMY bias ON at 400 [V], with the opposite sign as in observation (Negative in NLN, switch to Positive for vent)
for the duration of the vent (i.e. until we open back up to the arms)
Images attached to this report