ETMX PCAL Baffle install is finished

This morning, CoreyG, Marek, DanB and I went to EX and installed the last 2 baffle panels on the PCALX periscope. Marek & Corey stayed outside the chamber, used the top gun on the panels and installed fasteners in. Dan and I waited inside, and put screw caps on while they were working outside. No real issues. All hardware has been installed, including screw caps and barrel baffle fastener swap (for new coated hardware, this had been done a couple weeks ago). Corey took some photos, hopefully he'll post.

Comments related to this report
corey.gray@LIGO.ORG - 14:42, Tuesday 15 May 2018 (42000)

These parts, of the EX PCal Baffle (D1200174), were installed today:

  • D1700165-V4 Type -03, S/N:  001
  • D1700165-V4 Type -04, S/N:  001

Attached are photos from EX PCal Baffle install:

  1. Marek & type-4 baffle part
  2. Dan & Jim installing baffle part
  3. Marek & type-3 baffle part
  4. Marek getting ready to hand off part to Jim
  5. Needling baffle part under the Arm Cavity Baffle (ACB)
  6. Finished Baffle assembly (w/ flash)
  7. Finished Baffle assembly

To Do:  Would be nice if these parts could be ICS-ed.  Not sure if we have notes for all parts installed previously.

 

Images attached to this comment
stephen.appert@LIGO.ORG - 17:47, Friday 18 May 2018 (42082)

ICS Work nearly complete - see FRS Ticket 10690 for current status.

    https://services.ligo-la.caltech.edu/FRS/show_bug.cgi?id=10690