Reports until 14:05, Wednesday 05 December 2012
H1 ISC
corey.gray@LIGO.ORG - posted 14:05, Wednesday 05 December 2012 - last comment - 14:15, Thursday 10 January 2013(4845)
H1 EX TransMon Suspension Green-Light QPD Sled Complete (& In Storage)

(Corey, Keita)

My mode-matching lessons from master Jedi Kawabe continue with the building of the EX Green QPD Sled.  This Sled is one of two on EACH Transmission Monitor Suspension (TMS); the other is an IR QPD Sled (to be assembled next).  We actually built this Sled twice.  After completing it the first time, Keita noticed, "this sled looks like EY.  It's supposed to be a mirror image!"  It was all a learning experience.  So, we ended up re-building the sled (it went much quicker since we, in essence, already had an assembly dry run).

Once the Sled was completed, we draped wipes over all optical components, wrapped the entire assembly in foil, double-bagged it, and placed the entire thing in a large plastic bin for storage under our Optics Table in the Optics Lab (the HAM1WFS Sled is also stored here). 

Keita has plots and data from our mode matching measurements and will post a more thorough document about our EX Green Sled work to the DCC.

Note:  The "J-Clip" Black Glass Beam Dumps on our Steering Mirrors are tough to install.  There's a screw on the mount which interferes with the J-Clip and makes installing/removing these parts tough.

Images attached to this report
Comments related to this report
corey.gray@LIGO.ORG - 12:40, Tuesday 18 December 2012 (4960)

I have uploaded all photos for this EX Green Sled on ResourceSpace, here.

corey.gray@LIGO.ORG - 14:15, Thursday 10 January 2013 (5067)

Forgot to measure distance between optical components on this Sled, so it was opened up and these measurements were made.

For measurements below, the lenses are measured on the "backface" of their Lens Holder.  The Mirrors & Beam Splitters are measured from their glass "front faces".  The QPDs are measured from the QPD Housing plate (D1002110).  Measurements were measured with a scale & all measurements are in mm.

  • L1 to BS1 = 35
  • BS1 to QPD1 = 88
  • BS1 to L2 = 233
  • L2 to SM1 = 68
  • SM1 to SM2 = 59
  • SM2 to L3 = 282
  • L3 to SM3 = 117
  • SM3 to QPD2 = 77