Reports until 22:27, Saturday 22 June 2019
H1 GRD (GRD)
travis.sadecki@LIGO.ORG - posted 22:27, Saturday 22 June 2019 - last comment - 13:50, Tuesday 25 June 2019(50130)
INIT_ALIGN error

See screenshot for error midway up the log.  All I did was reload INIT_ALIGN guardian and it seemed to move on fine.  Maybe needs more investigation.

Images attached to this report
Comments related to this report
thomas.shaffer@LIGO.ORG - 13:00, Tuesday 25 June 2019 (50175)

This is a case of too many managers trying to both use ALIGN_IFO. I have commented out the unstall_nodes decorator in ISC_LOCK's inital_alignment state. The INIT_ALIGN node is already unstalling what it needs to, and INIT_ALIGN shouldn't need to be unstalled.

sheila.dwyer@LIGO.ORG - 13:35, Tuesday 25 June 2019 (50176)

Sorry about that.  I added that unstall nodes because we had seen the IMC guardian become stalled during Init align.  Does Align IFO manage the IMC and unstall it when it looses lock?

thomas.shaffer@LIGO.ORG - 13:50, Tuesday 25 June 2019 (50177)

Ah, no it doesn't. I'll change ISC_LOCK to check on that, and I'll triple check the other nodes.