J. Kissel More details to come later, but I've measured this week's sensing and actuation function after the 20200103 calibration model install today in to CALCS (see LHO aLOG 54473). The IFO is running in it's nominal configuration (much like the 2019-12-26 reference data set): 38W input, 50 ct SRCL offset, and "a few" dB of squeezing. /ligo/svncommon/CalSVN/aligocalibration/trunk/Runs/O3/H1/Measurements/FullIFOSensingTFs 2020-01-13_H1_DARM_OLGTF_LF_SS_5to1100Hz_15min.xml 2020-01-13_H1_PCALY2DARMTF_LF_SS_5t1100Hz_10min.xml 2020-01-13_H1_PCALY2DARMTF_BB_3min.xml /ligo/svncommon/CalSVN/aligocalibration/trunk/Runs/O3/H1/Measurements/FullIFOActuationTFs/ 2020-01-13_H1SUSETMX_L1_iEXC2DARM_8min.xml 2020-01-13_H1SUSETMX_L1_PCAL2DARM_5min.xml 2020-01-13_H1SUSETMX_L2_iEXC2DARM_12min.xml 2020-01-13_H1SUSETMX_L2_PCAL2DARM_6min.xml 2020-01-13_H1SUSETMX_L3_iEXC2DARM_12min.xml 2020-01-13_H1SUSETMX_L3_PCAL2DARM_6min.xml