Reports until 14:01, Thursday 11 April 2013
H1 SUS
arnaud.pele@LIGO.ORG - posted 14:01, Thursday 11 April 2013 - last comment - 09:12, Friday 19 April 2013(6032)
PR2 TF

Looking at PR2 transfer functions ran yesterday night, an extra resonnance appears at 2.8 Hz for M1 pitch to pitch transfer function when comparing it to the model and phase 3a testing transfer functions ran on december 2012.

Betsy and Travis are investigating to find its source.

Images attached to this report
Comments related to this report
arnaud.pele@LIGO.ORG - 16:18, Thursday 11 April 2013 (6033)

Attached is the pdf  with all DOF and comparisons with LHO measurements ( "allhstss[...]") with the following legend :

  • Phase 2a (july 2012)
  • 2b (august 2012)
  • 3a (december 2012) 
  • 3a (last one april 2013)
  • 3a (last one april 2013 damping on)
  • Model

The second pdf ("2013-04-10[...]") shows -in addition to the comparison between measurement and model for every DOF-  the coupling between DOF and individual OSEMs which might be helpful for understanding what's going on.

Non-image files attached to this comment
arnaud.pele@LIGO.ORG - 09:12, Friday 19 April 2013 (6138)

We decided to approve phase 3a for PR2, and postpone the investigation for next time the chamber we'll be open.