Naoki, Camilla
We reverted PSAMS from 7.5/0.55 to 8.8/-0.67, which was done last Friday in 77133. Before and after PSAMS change, we ran SCAN_ALIGNMENT and took 5+5 min asqz/sqz data. The attached figure shows that 8.8/-0.67 is better than 7.5/0.55. In parallel, A2L tuning was ongoing so the noise below 100 Hz in SQZ should be due to A2L.
asqz 120/137 (strain voltage 7.5/0.55) (5 min)
PDT: 2024-04-18 10:59:48 PDT
UTC: 2024-04-18 17:59:48 UTC
GPS: 1397498406
sqz 120/137 (strain voltage 7.5/0.55) (5 min)
PDT: 2024-04-18 11:06:29 PDT
UTC: 2024-04-18 18:06:29 UTC
GPS: 1397498807
asqz 170/95 (strain voltage 8.8/-0.67) (5 min)
PDT: 2024-04-18 12:01:57 PDT
UTC: 2024-04-18 19:01:57 UTC
GPS: 1397502135
sqz 170/95 (strain voltage 8.8/-0.67) (5 min)
PDT: 2024-04-18 13:35:01 PDT
UTC: 2024-04-18 20:35:01 UTC
GPS: 1397507719